Issue: 01 Specification AXE10P(E) Oscillator type : PXO (Clock) with PECL Output Parameter min. Frequency range Standard frequencies Frequency stability Initial tolerance vs. temperature in operating temperature range (steady state) vs. supply voltage variation vs. load change long term (aging) per year 19.440 212.5 MHz 125.000 / 155.520 MHz -25 25 ppm ppm ppm Frequency adjustment range Electronic Frequency Control (EFC) range RF output Signal waveform Load Rise & decay time Symmetry (duty cycle) Start-up time Jitter Supply voltage VS Current consumption (steady state @ +25°C) Enable/disable function Operating temperature range Operable temperature range Storage temperature range Enclosure (see drawing) (LxWxH) typ. max. Unit ±3 ±1 ±3 PECL 50 Date: 2005-06-08 Condition (see Note 1) Included in “frequency stability” ppm ppm ppm VS ±5% Load ±5% per year @ +25°C ppm N.A. Ω 1 ns 40 60 % 10 ms 1 ps 3.13 3.3 3.47 V 4.75 5.0 5.75 V 120 mA 80 mA Not applicable Pin2 = “LOW”: Enable Pin2 = “HIGH”: Disable 0 +70 °C -40 +85 °C -45 +90 °C -55 +105 °C 14.8x9.8x5.5 max mm To VEE 20%~80% of waveform @ 50% of waveform r.m.s. 10 kHz ~ 20 MHz Option I = “33” Option I = “50” Option I = “33” Option I = “50” AXE10P AXE10PE Option II = “070” Option II = “485” IEC 61837 CO 26(AXE10P) CO 27 (AXE10 PE) 3 gram Weight Tape & reel IEC 60286-3 Packing 1500 V HBM as in IEC 61000-4-2 ESD Sensitivity Notes: 1. Frequency stability = initial tolerance + temp.stability 2. Absolute Pull Range (APR) = EFC range - temperature stability - supply & load change – aging 3. Terminology and test conditions are according to IEC standard IEC60679-1, unless otherwise stated Ordering Code: Model (Specification) AXE10P AXE10PE GmbH & Co. KG Wasemweg 5 D-74821 Mosbach Germany Option I Option II Frequency [MHz] 50 070 155.520 AXE10P page 1(2) www.axtal.com fon: +49 (6261) 939834 fax: +49 (6261) 939836 E-mail: [email protected] Enclosure drawing Pin connections AXE10P: Pin # Symbol Function 1 RF OUT2 Complementary RF Out 2* N.C. No Connection 3 GND Ground 4 RF OUT1 RF Output 5* N.C. No Connection 6 Vs Supply Voltage * Note: Pins 2 and 5 may not be present AXE10PE: Pin # Symbol 1 RF OUT2 2 E/D 3 GND 4 RF OUT1 5 N.C. 6 Vs Function Complementary RF Out Enable/Disable Ground RF Output No Connection Supply Voltage Environmental conditions Test IEC 60068 Part ... Visual inspection, dimensions Sealing tests (if applicable) Solderability Resistance to soldering heat Shock* IEC 60679-1 clause ... 4.3 2-17 4.6.2 2-20 2-58 4.6.3 2-27 4.6.8 Bump* 2-29 4.6.6 Free fall* 2-32 4.6.9 Test conditions Enclosure styles as in IEC 60679-3 or 61837, if applicable Gross leak: Test Qc, Fine leak: Test Qk Test Ta (235 ± 5)°C Method 1 Test Tb Method 1A, 5s Vibration, sinusoidal* 2-6 4.6.7 Rapid change of temperature Dry heat 2-14 4.6.5 2-2 4.6.14 Damp heat, cyclic* 2-30 4.6.15 Cold 2-1 4.6.16 Climatic sequence* 1-7 4.6.17 Damp heat, steady state* Endurance tests - ageing - extended aging 2-3 4.6.18 Test Ea, 3 x per axes 100g, 6 ms half-sine pulse Test Eb, 4000 bumps per Axes, 40g, 6 ms Test Ed procedure 1, 2 drops from 1m height Test Fc, 30 min per axes, 10 Hz - 55 Hz 0,75mm; 55 Hz - 2 kHz, 10g Test Na, 10 cycles at extremes of operating temperature range Test Ba, 16 h at upper temperature indicated by climatic category Test Db variant 1 severity b), 55°C/95% r.H., 6 cycles Test Aa, 2 h at lower temperature indicated by climatic category Sequence of 4.6.14, 4.6.15 (1st cycle), 4.6.16, 4.6.15 (5 cycles) Test Ca, 56 days 4.7.1 4.7.2 30 days @ 85°C, OCXO @25°C 1000h, 2000h, 8000h @85°C GmbH & Co. KG Wasemweg 5 D-74821 Mosbach Germany AXE10P page 2(2) www.axtal.com fon: +49 (6261) 939834 fax: +49 (6261) 939836 E-mail: [email protected]