Dallas DS1260-50 Smart battery Datasheet

DS1260
Smart Battery
www.dalsemi.com
FEATURES
Encapsulated lithium energy cell with shelf
life beyond 10 years
Available with energy capacities of 250, 500,
and 1,000 mAH @ 3 volts
Plugs into a standard 16-pin DIP socket
Lithium cell electrically disconnects from
exposed pins upon command
Battery isolation ensures full capacity after
shipping and handling
Lithium cell automatically reconnects when
VCC is applied
Recessed pins prevent bending
VCC fail signal interrupts processor or writeprotects memory
Exhausted energy cell warning signal
Low profile permits mounting on 0.5-inch
printed circuit board centers
Mates directly with DS1212 Nonvolatile
Controller to back up 16 SRAMs
Uninterruptible supply for CMOS and
portable devices
PIN ASSIGNMENT
16
15
14
13
12
11
10
9
1
2
3
4
5
6
7
8
See Mech. Drawings Section
PIN DESCRIPTION
Pins 1, 2, 4, 7, 9, 10 and 14 are No-Connects
Pin 3 is Battery Fail ( BF )
Pin 5 is Battery Out (BAT)
Pin 6 is RESET (RST) Input
Pin 8 is Ground
Pin 11 is Power Fail ( PF )
Pins 12 and 13 are RAM Supply (VCCO)
Pins 15 and 16 are +5V Supply (VCCI)
DESCRIPTION
The DS1260 SmartBattery is a low-cost, backup energy supply for portable and nonvolatile electronic
equipment. A lithium energy source of up to 1 amp hour can supply power to CMOS electronic circuits
when primary power is lost through an intelligent and efficient switch. When power is supplied from the
lithium power source, the power fail signal is held low to warn electronic (RESET) circuits of the power
status. Energy loss during shipping and handling is avoided by pulsing RESET, thereby causing the
backup energy source to be isolated from the exposed pins. The DS1260 can be plugged into a standard
16-pin, low-cost DIP socket, allowing for proven interconnect and simple replacement if the energy has
been exhausted.
1 of 8
111999
DS1260
OPERATION
During normal operation VCCI (pins 15 and 16) is the primary energy source and power is supplied to
VCCO (pins 12 and 13) through an internal switch at a voltage level of VCCI-0.2 volts @ 250 mA. During
this time the power-fail signal ( PF ) is held high, indicating valid primary voltage (see Figure 1).
However, if the VCCI falls below the level of 4.25 volts, the power-fail signal is driven low. As VCCI falls
below the level of the lithium supply (VBAT = 3 volts), power is switched and the lithium energy source
supplies power to the uninterruptible output (VCCO) at VBAT-0.2 volts @ 5 mA.
On power-up, as the VCCI supply rises above 3 volts, the primary energy source, VCCI, becomes the
supply. As the VCCI input rises above 4.25 volts, the power-fail signal is driven back to the high level.
During normal operation, BAT (Pin 5) stays at the battery level of 3 volts, regardless of the level of VCCI.
BATTERY FAIL
When power is being supplied from the primary energy source, BF (Pin 3) is held at a high level (VOH),
provided that the lithium energy source is greater than 2 volts. If the lithium energy source should
decrease to below 2 volts, the BF signal is driven low (VOL), indicating an exhausted lithium battery. The
BF signal is always low when power is being supplied by the lithium energy source.
RESET
The reset input can be used to prevent the lithium energy source from supplying power to VCCO and BAT
even if VCCI falls below 3 volts. This feature is activated by applying a pulsed input on RST to a high
level (VIH) for 50ns minimum while primary power is valid (see Figure 2). When primary power is
removed after pulsing RST, the VCCO output and BAT will go to high impedance. The next time primary
power is applied such that VCCI is greater than VBAT, normal operation resumes and VCCO will be supplied
by the lithium energy source when VCCI again falls below 3 volts. BAT will also return to the level VBAT.
Figure 3 shows how the SmartBattery is used in a system application.
BLOCK DIAGRAM Figure 1
2 of 8
DS1260
BATTERY PERFORMANCE DS1260-25
3 of 8
DS1260
BATTERY PERFORMANCE DS1260-50
4 of 8
DS1260
BATTERY PERFORMANCE DS1260-100
5 of 8
DS1260
Table 1
PART NO.
DS1260-25
DS1260-50
DS1260-100
CAPACITY
250 mAH
480 mAH
960 mAH
NOMINAL VOLTAGE
3 volts
3 volts
3 volts
RESET TIMING Figure 2
INTEGRATED BATTERY BACKUP – APPLICATIONS Figure 3
6 of 8
DS1260
ABSOLUTE MAXIMUM RATINGS*
Voltage on Any Pin Relative to Ground
Operating Temperature
Storage Temperature
Soldering Temperature
*
-0.3V to +7.0V
0°C to 70°C
-40°C to +70°C
260°C for 10 seconds
This is a stress rating only and functional operation of the device at these or any other conditions
above those indicated in the operation sections of this specification is not implied. Exposure to
absolute maximum rating conditions for extended periods of time may affect reliability.
RECOMMENDED DC OPERATING CONDITIONS
PARAMETER
Primary Power Supply
Input High Voltage
Input Low Voltage
SYMBOL
VCC
VIH
VIL
MIN
4.5
2.0
-0.3
DC ELECTRICAL CHARACTERISTICS
PARAMETER
Leakage Current
Output Current @ 2.4V
Output Current @ 0.4V
Input Supply Current
Pins 12, 13 VCCO=VCCI-0.2
Pin 11 PF Detect
Pin 3 BF Detect
SYMBOL
ILO
IOH
IOL
ICCI
ICCO
VTP
VBATF
MIN
-1.0
-1.0
(0°C to 70°C)
TYP
5.0
MAX
5.5
VCCI+0.3
+0.8
UNITS
V
V
V
NOTES
1
1
1
(0°C to 70°C; VCCI = 4.0 to 5.5V)
TYP
4.25
2.0
MAX
+1.0
+4.0
5
250
4.5
UNITS
µA
mA
mA
mA
mA
V
V
NOTES
1, 2
1, 2
3
4
7
(0°C to 70°C; VCCI < VBAT)
Pin 5 Battery Voltage
Pins 12, 13 VCCO=VBAT-0.2
Battery Leakage
Pin 5 Battery Output Current
VBAT
ICCO2
IBAT
3
IBATOUT
15
100
100
V
mA
nA
µA
MAX
10
10
UNITS
pF
pF
CAPACITANCE
PARAMETER
Output Capacitance
Input Capacitance
(tA = 25°C)
SYMBOL
CO
CI
MIN
AC ELECTRICAL CHARACTERISTICS
PARAMETER
VCCI Slew Rate
VCCI Slew Rate
Power-Down to PF Low
PF High after Power-Up
6
5
8, 9
SYMBOL
tF
tR
tPF
tREC
MIN
300
1
0
TYP
5
5
(0°C to 70°C; VCCI = 4.0 to 5.5V)
TYP
MAX
100
7 of 8
NOTES
UNITS
µs
µs
µs
µs
NOTES
DS1260
POWER-DOWN/POWER-UP CONDITION
WARNING:
Under no circumstances are negative undershoots, of any amplitude, allowed when device is in battery
backup mode.
Water washing for flux removal may discharge internal lithium source as exposed voltage pins are
present.
NOTES:
1. Voltages are referenced to ground.
2. Load capacity is 50 pF.
3. Measured with Pins 11, 12, 13, and 3 open.
4. VTP is the point that PF is driven low.
5. Sustained ICCO2 currents above 1 mA cause a significant drop in battery voltage.
6. VBAT is the internal lithium energy source voltage.
7. VBATF is the point that BF is driven low.
8. Battery leakage is the internal energy consumed by the DS1260.
9. Storage loss is less than 1% per year at 25°C.
10. VCCI = +5 volts; tA = 25°C.
8 of 8