Embedded Power for Business-Critical Continuity Rev. 03.24.08 LPS120 Series 1 of 3 LPS120 Series 120 Watts Total Power: Input Voltage: # of Outputs: RoHS 80 - 130 Watts 85 - 264 VAC Single Electrical Specifications Special Features • • • • • • • • • • • • • Active power factor correction 3" x 5" footprint Less than 1U high EN61000-3-2 compliant Remote sense Power fail and remote inhibit Single wire current sharing Adjustable main output Built-in Class B EMI filter Overvoltage protection Overload protection Thermal overload protection 5 V Standby output and 12V Fan output Input Input range: Frequency: Inrush current: Efficiency: EMI/RFI: Power factor: Safety ground leakage current: Output Maximum power: Adjustment range: Fan output: Standby outputs: Hold-up time: Overload protection: 80W for convection ; 130W with 30CFM forced air ±5% minimum on the main outputs 12V @ 500mA - 5%, +7% 5V @ 500mA ±5% 20ms @ 125W load, 120VAC input Short circuit protection on all outputs. Case overload protected @ 120-135% above rating Overvoltage protection: 20-35% above nominal output Remote sense: Compensates for 0.5 V lead drop max. Will operate without remote sense connected. Reverse connection protected. Logical Control Power failure: Safety TUV: UL: CSA NEMKO: AUSTEL: CB: CE: Remote inhibit: 60950 60950 60950 60950 60950 Certificate and report Mark (LVD) 85 - 264 VAC ; 127 - 300VDC 47-440 Hz 40A max., cold start @ 25°C 80% typical at full load FCC Class B conducted; CISPR22 Class B conducted; EN55022 Class B conducted; VDE0878PT3 Class B conducted 0.99 typical 0.5mA @ 50/60 Hz, 264 VAC input Remote sense: TTL logic signal goes high 100-500 msec after main output; it goes low at least 4 msec before loss of regulation Requires a contact closure to disable the outputs, except 5V standby. Compensates for 0.5 V lead drop min. Will operate without remote sense connected. Reverse connection protected. Embedded Power for Business-Critical Continuity Rev. 03.24.08 LPS120 Series 2 of 3 Environmental Specifications Operating temperature: SK1 0.15" DIA. 4 places (4.0) LIVE MTBF demonstrated -40°C to +85°C designed to meetEN61000-4; -2, -3, -4, -5, -6, -8, -11 Level 3 NEUTRAL Vibration: 2.55 (64.8) EARTH Humidity: 3.00 (76.2) 0° to 50°C ambient derate each output as 2.5% per degree from 50° to 70°C. -20°C start up P1 Storage temperature: Electromagnetic susceptibility: Mechanical Drawing Operating; non-condensing 10% to 95% RH IEC68-2-6 to the levels of IEC721-3-2 >550,000 hours at full load and 25°C ambient conditions 5.00 (127.0) 4.55 (115.6) 1 2 SK3 M3.5 (2 places) SK2 V Adjust POT 1.29 (32.8) 5 1 6 10 SK3 0.20" (5) Embedded Power for Business-Critical Continuity Americas Ordering Information Output Voltage Minimum Load Maximum Load with Convection Cooling 3.3V 0A 21A LPS122 5V 0A 16A LPS123 12V 0A 6.7A LPS124 15V 0A 5.3A LPS125 24V 0A LPS128 48V 0A Model Number LPS121 Maximum Load Peak Load Regulation2 with 30CFM Forced Air 36A Ripple P/P (PARD)3 29A ±2% 50mV 26A 29A ±2% 50mV 10.8A 12.8A ±2% 120mV 8.7A 10.0A ±2% 150mV 3.4A 5.4A 6.3A ±2% 240mV 1.7A 2.7A 3.2A ±2% 480mV 1. Peak current lasting <30 seconds with a maximum 10% duty cycle. 2. At 25°C including initial tolerance, line voltage, load currents and output voltages adjusted to factory settings. 3. Peak-to-peak with 20 MHz bandwidth and 10 μF (tantalum capacitor) in parallel with a 0.1 μF capacitor at rated line voltage and load ranges. 4. When in parallel a 10% load is required for each power supply. Pin Assignments Connector LPS120 SK1 Pin1 Pin3 Neutral Line SK2 TB-1 TB-2 COMMON Main output SK3 Pin1 Pin2 Pin3 Pin4 Pin5 Pin6 Pin7 Pin8 Pin9 Pin10 +V1 Remote sense -V1 Remote sense +Remote inhibit -Remote inhibit +Power fail Common SWP +12V 12V common +5V standby 5810 Van Allen Way Carlsbad, CA 92008 USA Telephone: +1 (760) 930 4600 Facsimile: +1 (760) 930 0698 Rev. 03.24.08 LPS120 Series 3 of 3 Europe (UK) Waterfront Business Park Merry Hill, Dudley West Midlands, DY5 1LX United Kingdom Telephone: +44 (0) 1384 842 211 Facsimile: +44 (0) 1384 843 355 Asia (HK) 14/F, Lu Plaza 2 Wing Yip Street Kwun Tong, Kowloon Hong Kong Telephone: +852 2176 3333 Facsimile: +852 2176 3888 For global contact, visit: www.powerconversion.com techsupport.embeddedpower @emerson.com While every precaution has been taken to ensure accuracy and completeness in this literature, Emerson Network Power assumes no responsibility, and disclaims all liability for damages resulting from use of this information or for any errors or omissions. Emerson Network Power. The global leader in enabling business-critical continuity. AC Power Mating Connectors (SK1)AC Input: Molex 09-50-8031 (connector) 08-52-0113 (pins) Connectivity (SK2)DC Output: Molex series 19141-0058/0063 Spade lug DC Power (SK3) Control Signals: Molex 90142-0010 (USA) PINS: 90119-2110 or Amp: 87977-3 PINS: 87309-8 Embedded Computing Embedded Power Monitoring Astec Connector Kit # 70-841-020, includes all of the above. Outside Plant Notes: 1. Specifications subject to change without notice. 2. All dimensions in inches (mm), tolerance is ±.02”. 3. mounting holes MH1, MH2, MH3 should be grounded for EMI purpose 4. Mounting MH1 is safety ground connection 5. Specifications are for convection rating at factory settings at 115 VAC input 25 C deg unless otherwise stated. 6. This power supply requires mounting on metal standoffs 0.20” (5m) in height. 7. Warranty: 2 year 8. Weight: 0.71 lb. / 0.32 kg Power Switching & Controls Precision Cooling Racks & Integrated Cabinets Services Surge Protection EmersonNetworkPower. com Emerson Network Power and the Emerson Network Power logo are trademarks and service marks of Emerson Electric Co. ©2008 Emerson Electric Co.