Alternating Input Module MI-AIM™ Actual size: 2.28 x 2.4 x 0.5in 57,9 x 61,0 x 12,7mm AC Input Front End Module Features & Benefits Packaging Options • Inputs: 115VAC 60/400Hz Standard: Slotted baseplate • Output power: 250W SlimMod: • MIL-STD-704A input transient protection Flangeless baseplate, option suffix: - S Example: MI - AIM - M1 - S FinMod: Finned heat sink, option suffix: - F1, - F2, -F3 or -F4 • MIL-STD-461D/E EMI compliant* • MIL-STD-810, MIL-STD-202 environments • Compatible with MI-x7x family modules • Efficiency: 95% Examples: MI - AIM - M1 -F1, 0.25” fins, longitudinal MI - AIM - M1 -F2, 0.50” fins, longitudinal MI - AIM - M1 -F3, 0.25” fins, transverse MI - AIM - M1 -F4, 0.50” fins, transverse Input Characteristics • Operating temperature to 100˚C Parameter • Size: 2.28” x 2.4” x 0.5” (57,9 x 61,0 x 12,7mm) AC line input Min Typ Max Unit 85 115 140 VAC 47 60/400 440 Hz 40 A, peak Inrush current Product Highlights The AC input module interfaces directly with AC mains to provide line rectification, EMI filtering, transient protection, and inrush limiting. These front-end modules accept 115VAC and provide 250W of output power for any of Vicor’s MI-x7x family of standard and junior size modules. Notes Operates over entire range 125VAC Conducted EMI*CE102 per MIL-STD-461 D/E 100 – 125VAC; 60Hz Performance Criteria: Nominal output voltage may deviate but self recovers TABLE SAC109-II normal Input transient voltage transients MIL-STD-704A/ MIL-HDBK-704-1-8 TABLE SAC302-II abnormal voltage transients Performance Criteria: Nominal output voltage may deviate but self recovers *EMI performance is subject to a wide variety of external influences such as PCB construction, circuit layout etc. As such, external components in addition to those listed herein may be required in specific instances to gain full compliance to the standards specified. The MI-AIM meets CE102 conducted emissions requirements of MIL-STD-461D/E* and the transient and spike requirements of MIL-STD-704A. Fully encapsulated in Vicor’s industry standard package, the MI-AIM meets MIL-STD-810 Environmental testing requirements for humidity, fungus, salt-fog, explosive atmosphere, acceleration, vibration and shock. Output Characteristics Parameter Min Output power Typ Max 250 Unit Notes W 100 °C Hold-up time Application specific A function of external capacitance and power Efficiency95% 115VAC; 60/400Hz Model Selection Chart Model Number Compatible MI-Series MI-AIM-M1 MI-AIM-I1 MI-AIM™ Page 1 of 5 Rev 1.6 06/2017 MI-27x /MI-J7x MI-27x /MI-J7x Converter Operating Temp (°C) Storage Temp (°C) M–grade I–grade –55 to +85 /+100 –40 to +85 /+100 –65 to +100 /+125 –55 to +100/+125 vicorpower.com 800 927.9474 MI-AIM™ Specifications (typical at TBP = 25°C, nominal line and 75% load, unless otherwise specified) SAFETY SPECIFICATIONS Parameter Min Dielectric withstand Input to output Input/output to baseplate Typ Max Unit None 1,500 Notes Provided by DC-DC converter VRMS ENVIRONMENTAL — MIL-STD-810D Parameter Min Typ Max Unit Notes Procedure II Altitude - Method 500.2 70,000 feet Humidity - Method 507.2 88/ 240 %/ hours Procedure I, cycle 1 Acceleration - Method 513.3 9.0 g Procedure II Vibration - Method 514.3 20 g Procedure I, category 6 Shock - Method 516.3 40 g Procedure I RELIABILITY — MIL-HDBK-217F (MI-AIM-M1) Parameter Min Typ Max Unit 25°C Ground Benign: G.B. 5,545 1,000 hrs 50°C Naval Sheltered: N.S. 998 1,000 hrs 65°C Airborne Inhabited Cargo: A.I.C. 782 1,000 hrs Notes GENERAL SPECIFICATIONS Parameter Min Size Typ Max 2.28 x 2.4 x 0.5 (57,9 x 61,0 x 12,7) Unit Notes in (mm) 3.0 Ounces Weight (85) (Grams) MI-AIM™ Page 2 of 5 Rev 1.6 06/2017 vicorpower.com 800 927.9474 MI-AIM™ Specifications (Cont.) PRODUCT GRADE SPECIFICATIONS Parameter I-Grade M-Grade Storage temperature -55°C to +125°C -65°C to +125°C Operating temperature (baseplate) -40°C to +100°C -55°C to +100°C 12 hours, 29 cycles 96 hours, 213 cycles 12 cycles -65°C to +100°C 12 cycles -65°C to +100°C -40°C, +80°C -55°C, +80°C 2 years 2 years MIL-STD-810 MIL-STD-810 NAVMAT P-4855-1A NAVMAT P-4855-1A Power cycling burn-in Temperature cycled with power off 17°C per minute rate of change Test data supplied at these temperatures [a] Warranty Environmental compliance Derating [a] Test data available for review or download from vicorpower.com ENVIRONMENTAL QUALIFICATIONS Parameter Altitude Explosive Atmosphere Qualification MIL-STD-810D, Method 500.2, Procedure III, explosive decompression (40K ft.). MIL-STD-810D, Method 500.2, Procedure II, 40,000ft., 1000 – 1500ft./ min. to 70,000ft., unit functioning MIL-STD-810C, Method 511.1, Procedure I MIL-STD-810D, Method 514.3, Procedure I, category 6, helicopter, 20g Vibration MIL-STD-810D, Method 514.3 random: 10 – 300Hz @ 0.02g 2 /Hz, 2000Hz @ 0.002g 2 / Hz, 3.9 total Grms 3hrs/axis. Sine: 30Hz @ 20g, 60Hz @ 10g, 90Hz @ 6.6g, 120Hz @ 5.0g, 16.0 total Grms, 3 axes MIL-STD-810E, Method 514.4, Table 514.4-VII, ±6db/octave, 7.7Grms, 1hr/axis MIL-STD-810D, Method 516.3, Procedure I, functional shock, 40g Shock MIL-STD-202F, Method 213B, 18 pulses, 60g, 9msec MIL-STD-202F, Method 213B, 75g, 11ms saw tooth shock MIL-STD-202F, Method 207A, 3 impacts / axis, 1, 3, 5 feet Acceleration MIL-STD-810D, Method 513.3, Procedure II Operational test, 9g for 1 minute along 3 mutually perpendicular axes Humidity MIL-STD-810D, Method 507.2, Procedure I, cycle I, 240hrs, 88% relative humidity Solder Test MIL-STD-202, Method 208, 8hr. aging Fungus MIL-STD-810C, Method 508.1 Salt-Fog MIL-STD-810C, Method 509.1 Storage Vicor products, when not installed in customer units, should be stored in ESD safe packaging in accordance with ANSI/ESD S20.20, “Protection of Electrical and Electronic Parts, Assemblies and Equipment” and should be maintained in a temperature controlled factory/ warehouse environment not exposed to outside elements controlled between the temperature ranges of 15°C and 38°C. Humidity shall not be condensing, no minimum humidity when stored in an ESD compliant package. MI-AIM™ Page 3 of 5 Rev 1.6 06/2017 vicorpower.com 800 927.9474 MI-AIM™ Mechanical Drawings, Connection Diagram 0.01µF (Two 4700pF) Y-Rated Capacitors F1 L1 AC IN N/C 0.47µF F2 +OUT GATE IN GATE IN C1[b] PAR N/C GATE OUT L2/N +OUT +IN GATE OUT +S MI-27x/J7x Driver TRIM –OUT MI-AIM [b] 0.01µF (Two 4700pF) Y-Rated Capacitors 1,200µF max. Fuse 1: 7A F03A type recommended Fuse 2: MI-x7x-xx – Buss PC – TRON 2 – 5A (450V) VI-AIM Mechanical Figure 1 — MI-AIM Connection diagram, typical application in (mm) .30.015 (7,6)(0,38) .49 (12,4) 2.28 (57,9) 1.30 (33,0) .65 (16,5) .080 Dia (2) places Solder plate over copper alloy 4 2.10 (53,4) 3 2 9 8 VI-AIM MI-AIM 1.40 1.00 (35,6) .70 (25,4) .40 (17,8) (10,2) 7 6 1 .15 (3,8) Pin # 1 2 3 4 5 6 7 8 9 5 .35 .015 (8,9)(0,38) FULL R .15 (3,8) 1.90 (48,3) Function L1 NC NC L2/N +OUT Gate In Parallel Gate Out –OUT .040 (1,0) Dia (7) places Solder plate over copper alloy Product ID this surface 2.40 (61,0) .22 (5,6) Min. .50 (12,7) .12 (3,0) 1.75 Max. (44,4) .30 Min. (7,6) +.030 (0,76) -.000 (0) .01 Aluminum Base Figure 2 — Mechanical diagram Note: For alternate packaging options refer to the mechanical drawing page at vicorpower.com MI-AIM™ Page 4 of 5 Rev 1.6 06/2017 vicorpower.com 800 927.9474 Load –S –IN –OUT 0.01µF Ceramic 0.01µF Ceramic MI-AIM™ Vicor’s comprehensive line of power solutions includes high density AC-DC and DC-DC modules and accessory components, fully configurable AC-DC and DC-DC power supplies, and complete custom power systems. Information furnished by Vicor is believed to be accurate and reliable. However, no responsibility is assumed by Vicor for its use. Vicor makes no representations or warranties with respect to the accuracy or completeness of the contents of this publication. Vicor reserves the right to make changes to any products, specifications, and product descriptions at any time without notice. Information published by Vicor has been checked and is believed to be accurate at the time it was printed; however, Vicor assumes no responsibility for inaccuracies. Testing and other quality controls are used to the extent Vicor deems necessary to support Vicor’s product warranty. Except where mandated by government requirements, testing of all parameters of each product is not necessarily performed. Specifications are subject to change without notice. Visit http://www.vicorpower.com/mil-cots_ac-dc/mil-cots_mi-aim_ac_input_module for the latest product information. Vicor’s Standard Terms and Conditions and Product Warranty All sales are subject to Vicor’s Standard Terms and Conditions of Sale, and Product Warranty which are available on Vicor’s webpage (http://www.vicorpower.com/termsconditionswarranty) or upon request. Life Support Policy VICOR’S PRODUCTS ARE NOT AUTHORIZED FOR USE AS CRITICAL COMPONENTS IN LIFE SUPPORT DEVICES OR SYSTEMS WITHOUT THE EXPRESS PRIOR WRITTEN APPROVAL OF THE CHIEF EXECUTIVE OFFICER AND GENERAL COUNSEL OF VICOR CORPORATION. As used herein, life support devices or systems are devices which (a) are intended for surgical implant into the body, or (b) support or sustain life and whose failure to perform when properly used in accordance with instructions for use provided in the labeling can be reasonably expected to result in a significant injury to the user. A critical component is any component in a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system or to affect its safety or effectiveness. Per Vicor Terms and Conditions of Sale, the user of Vicor products and components in life support applications assumes all risks of such use and indemnifies Vicor against all liability and damages. Intellectual Property Notice Vicor and its subsidiaries own Intellectual Property (including issued U.S. and Foreign Patents and pending patent applications) relating to the products described in this data sheet. No license, whether express, implied, or arising by estoppel or otherwise, to any intellectual property rights is granted by this document. Interested parties should contact Vicor’s Intellectual Property Department. Vicor Corporation 25 Frontage Road Andover, MA, USA 01810 Tel: 800-735-6200 Fax: 978-475-6715 email Customer Service: [email protected] Technical Support: [email protected] MI-AIM™ Page 5 of 5 Rev 1.6 06/2017 vicorpower.com 800 927.9474