Arch AUC-5S Switching power module for pcb mountable Datasheet

VER : A_5
update : 2016.04.19
AC-DC Power Module
AUC SERIES
7
Watts
KEY FEATURES
 Switching Power Module for PCB Mountable
 Fully Encapsulated Plastic Case
 Universal Input Range 90-264VAC, 50 / 60 Hz
 No-Load Watts < 0.1W
 Ultra Compact Size: 1.08” x 1.08” x 0.736” Inches
 Isolation Class II
 CE, CB, UL Approval
 3-Year Product Warranty
ELECTRICAL SPECIFICATIONS
All specifications valid at normal input voltage, full load and +25°C after warm-up time unless otherwise stated.
Model No.
( Single Output )
Max Output Wattage (W)
Voltage
Protection
Isolation
Environment
Physical
7W
AUC-24S
180 mA max. (115 VAC) / 110 mA max. (230 VAC)
(Note 4.)
Leakage Current
Output
6.3W
AUC-15S
50 / 60 Hz
Current (Full load)
Inrush Current
AUC-12S
90-264 VAC or 120-370 VDC, “ N ” to DC “ + “ ; “L ” to DC “ - “
Frequency (Hz)
Input
AUC-5S
20 A max. (115 VAC) / 40 A max. (230 VAC)
0.25 mA max. (at <240 VAC).
External Fuse (mandatory)
2 A slow blow type
Voltage (V.DC.)
5V
Voltage Accuracy
±2%
Current (mA) max
1260
Line Regulation (LL-HL) (typ.)
±0.5%
Load Regulation (10-100%) (typ.)
±1%.
Minimum Load
0%
Maximum Capacitive Load
3300uF
Ripple
<100mV (Vp-p)
<200mV (Vp-p)
Noise
<150mV (Vp-p)
<200mV (Vp-p)
Efficiency (at 230 VAC)
77%
Hold-up Time (at 230 VAC)
30 ms min.
Over Power Protection
Hiccup technique, auto-recovery
12V
15V
24V
583
466
292
1000uF
470uF
68uF
80%
80%
Short Circuit Protection
Hiccup mode, indefinite (automatic recovery)
Input-Output (V.AC)
3000V
Operating Temperature
-40°C…+70°C ( with derating )
Storage Temperature
-40°C…+85°C
Temperature Coefficient
±0.02%/°C
Humidity
95% RH
MTBF
>500,000 h @ 25°C (MIL-HDBK-217F)
Dimension (L x W x H)
1.08 x 1.08 x 0.736 Inches
Case Material
Plastic resin (flammability to UL 94V-0)
Weight
26 g
Cooling Method
Free air convection
Safety
Agency Approvals
CE, UL, cUL
EMC
EMI
(Conducted & Radiated Emission)
EMS (Noise Immunity)
http://www.archcorp.com.tw
TEL: +886-2-26989508 FAX: +886-2-26981319
80%
( 27.4 x 27.4 x 18.7 mm ) Tolerance 0.5 mm
EN 55022 class B
EN 55024
-1-
VER : A_5
update : 2016.04.19
AC-DC Power Module
AUC SERIES
7
Watts
NOTE
1. All specifications valid at normal input voltage, full load and +25°C after warm-up time unless otherwise stated.
2. Ripple & Noise are measured at 20MHz of bandwidth with 0.1uF & 47uF parallel capacitor.
3. It's necessary Varistor 14S471K at L / N input side in parallel.
4. It's necessary 10R / 15φ thermistor at L input side in series connection.
5. Please refer to our PDF file "AC-DC Application" on our website: www.archcorp.com.tw
OUTPUT NOISE
The output noise is measured with 47F tantalum capacitor and 0.1F ceramic capacitor across output.
BLOCK DIAGRAM
MECHANICAL DIMENSION
DERATING
( Top View )
PIN#
Single
1
AC IN (N)
2
AC IN (L)
3
+DC OUT
4
-DC OUT
Customer is recommended to reserve pad points of 1.0mm in diameter for
AC IN (L) and AC IN (N)
http://www.archcorp.com.tw
TEL: +886-2-26989508 FAX: +886-2-26981319
-2-
Similar pages