Emerson Network Power NXI100 Non-isolated dc-dc converter Datasheet

Embedded Power for
Business-Critical Continuity
Rev.03.23.07
nxi100
1 of 4
NXI100 Series
Single output
Input Voltage: 12VDC
# of Outputs: Single
Special Features
• Designed for VRM9.0 and
VRM9.1 specification
• Low profile: 1.15 inches
including mating connector
• Microprocessor voltage
identification input
• 5 Bit VID input
• 1.10 Vdc to 1.85 Vdc in
25 mV steps
• Up to 50 A/μs load transient
no load to full load, recovery
within 50 μs
• Democratic current sharing,
no need for master/slave
configuration
• High efficiency: 87% typical @
Vin = 12 V, Vout = 1.5 V,
Iout = 60 A
• Available RoHS compliant
• 2 year warranty
The NXI100 non-isolated dc-dc converter simplifies the application
of Intel Xeon(TM) or Pentium®4 processors by providing a
purpose-designed, point-of-load, power management solution for
low-profile applications. Capable of delivering 81 A, and meeting
the exceptional transient response requirements of these loads,
the converter comes in a versatile, PCB-pluggable form.
Artesyn utilizes advanced circuit techniques, component selection
and state-of-the-art thermal packaging, to deliver reliable high
power density. Multi-phase power conversion provides
industry-leading conversion efficiency without adding
unneccesary complexity, and NXI100 meets the precise regulation
specifications of VRM9.0/9.1 without expensive external
components. An active circuit guarantees the current sharing
specification is met during static or dynamic loading conditions.
Embedded Power for
Business-Critical Continuity
Rev.03.23.07
nxi100
2 of 4
Specifications
All specifications are typical at nominal input, full load at 25°C unless otherwise stated.
OUTPUT SPECIFICATIONS
GENERAL CHARACTERISTICS
Voltage adjustability
See table
Output setpoint accuracy Vout
Ripple and noise
(See Note 1)
20 MHz bandwidth
Transient response
peak dev. settling time
(See Note 2)
Efficiency
1.5 V output @ 60 A
1.7 V output @ 60 A
Switching frequency
Fixed (See Note 3)
±0.8%
15 mV pk-pk
Standards
Short circuit protection
50 mV
25 μs
Continuous current
automatic recovery
990 kHz
94V-0 flammability rating
Weight
MTBF
87%
87%
40 g (1.41 oz)
Telcordia SR-332
Mating connector
850,000 hours
(See Note 4)
INPUT SPECIFICATIONS
Input voltage range
12 Vin nominal
11-12.6 Vdc
Input current
Operating
No load
OUTEN low
13.6 A
300 mA
40 mA max.
UVLO turn ON voltage
UVLO turn OFF Voltage
Start-up time
OUTEN
Logic compatibility
ON
OFF
9.9 V typ.
8.5 V typ.
Nominal line
Open circuit voltage
ENVIRONMENTAL SPECIFICATIONS
Maximum temperature
shock
Operating
Temperature shock
Operating
Non-operating
Humidity
Operating
Storage
85% RH
95% RH
Altitude
Operating
Storage
10,000 feet max.
50,000 feet max.
Shock
Operational
10 ms
Ref. to -input
5 Vdc
0.8 Vdc max.
Non-operational
Vibration
(See Note 5)
Operational and
non-operational
Electrostatic discharge
(See Note 6)
Operating
Non-operating
Thermal performance
(See Note 7)
Operating ambient
temperature
Non-operating
5 °C/10 min.
10 °C/hour
20 °C/hour
30 G 11 ms,
half sine wave
50 G 11 ms,
half sine wave
0.02 G2/Hz max.
ESD 15 kV
ESD 25 kV
0 °C to +60 °C
-40 °C to +100 °C
Embedded Power for
Business-Critical Continuity
Rev.03.23.07
nxi100
3 of 4
Specifications Contd.
INPUT
VOLTAGE
OUTPUT
VOLTAGE
OVP
12 Vdc
1.1-1.85 Vdc
120% of
VID setting
OUTPUT
CURRENT
(MIN)
OUTPUT
CURRENT
(MAX.)
EFFICIENCY
(TYP.)
REGULATION
LOAD
MODEL
NUMBER (9,10)
0A
81 A
87%
0.95 mV/A
NXI100-12P1V8CY
TABLE 1: PIN CONNECTIONS
PIN NO. FUNCTION
TABLE 2: VOLTAGE IDENTIFICATION (VID) CODES
VID4
VID3
VID2
VID1
VID0
VDAC
1
Vin+
PIN NO. FUNCTION
62
Vin-
1
1
1
1
1
Output off
2
Vin+
61
Vin-
1
1
1
1
0
1.100
3
Vin+
60
Vin-
1
1
1
0
1
1.125
4
Vin+
59
Vin-
1
1
1
0
0
1.150
5
Reserved
58
VRM-pres
1
1
0
1
1
1.175
6
Key
57
VID4
1
1
0
1
0
1.200
7
VID3
56
VID2
1
1
0
0
1
1.225
8
VID1
55
VID0
1
1
0
0
0
1.250
9
Reserved
54
Ishare
1
0
1
1
1
1.275
10
PWRGD
53
OUTEN
1
0
1
1
0
1.300
11
Vo sen-
52
Vo sen+
1
0
1
0
1
1.325
12
Reserved
51
Reserved
1
0
1
0
0
1.350
13
Vo-
50
Vo+
1
0
0
1
1
1.375
14
Vo+
49
Vo+
1
0
0
1
0
1.400
15
Vo-
48
Vo-
1
0
0
0
1
1.425
16
Vo+
47
Vo+
1
0
0
0
0
1.450
17
Vo-
46
Vo-
0
1
1
1
1
1.475
18
Vo+
45
Vo+
0
1
1
1
0
1.500
19
Vo-
44
Vo-
0
1
1
0
1
1.525
20
Vo+
43
Vo+
0
1
1
0
0
1.550
21
Vo-
42
Vo-
0
1
0
1
1
1.575
22
Vo+
41
Vo+
0
1
0
1
0
1.600
23
Vo-
40
Vo-
0
1
0
0
1
1.625
24
Vo+
39
Vo+
0
1
0
0
0
1.650
25
Vo-
38
Vo-
0
0
1
1
1
1.675
26
Vo+
37
Vo+
0
0
1
1
0
1.700
27
Vo-
36
Vo-
0
0
1
0
1
1.725
28
Vo+
35
Vo+
0
0
1
0
0
1.750
29
Vo-
34
Vo-
0
0
0
1
1
1.775
30
Vo+
33
Vo+
0
0
0
1
0
1.800
31
Vo-
32
Vo-
0
0
0
0
1
1.825
0
0
0
0
0
1.850
Embedded Power for
Business-Critical Continuity
Rev.03.23.07
nxi100
4 of 4
Americas
0.160 (4.06) REF
2.320 (58.93) REF
1
31
62
32
0.062 ±0.007 THICK
FR-4 2-Sided CKT BD
W/Gold Plated 30μ"
Connector Fingers
0.250 (6.35) REF
3.200 (81.28) REF
0.500 max.
(12.70)
3.800 (96.52)
3.186 ±0.002
(80.92 ±0.05)
0.307 (7.80)
5810 Van Allen Way
Carlsbad, CA 92008
USA
Telephone: +1 760 930 4600
Facsimile: +1 760 930 0698
Europe (UK)
Waterfront Business Park
Merry Hill, Dudley
West Midlands, DY5 1LX
United Kingdom
Telephone: +44 (0) 1384 842 211
Facsimile: +44 (0) 1384 843 355
Asia (HK)
0.855 (21.72)
0.305 (7.75)
62
1.143 (29.03)
0.042 (1.07) Typ.
Key slot
CL CL
0.265 (6.73) REF 0.820 max.
32
(20.83)
8.050
(1.27) REF
0.100 (2.54)
16th - 17th Floors, Lu Plaza
2 Wing Yip Street, Kwun Tong
Kowloon, Hong Kong
Telephone: +852 2176 3333
Facsimile: +852 2176 3888
For global contact, visit:
0.093 (2.36)
30 EQ Spaces @ 0.100 (2.54)
each Equals 3.000 (76.20)
TOL Non-Accum
www.powerconversion.com
Dimensions in Inches (mm)
Tolerances (unless otherwise specified)
2 Place ±0.02
Figure 1: Mechanical Drawing
[email protected]
While every precaution has been taken to ensure
accuracy and completeness in this literature, Emerson
Network Power assumes no responsibility, and disclaims
all liability for damages resulting from use of this
information or for any errors or omissions.
Notes
1
15 mV pk-pk ripple 8 x 560 μF/4 V OSCON and 10 x 4.7 μF/6.3 V MLCC’st on the output. Vin = 12 V, Vout = 1.5 V, Iout =
60 A.
2 125 mV peak deviation when slewing load from no load to full load at 50 A/μs. Oscon type low impedance caps required
across output.
3 Each phase operates at a fixed 330 kHz. Effective fundamental output
frequency is 990 kHz / 3 phases each at 330 kHz interleaved.
4 Recommended mating connector is AMP 1364125-1 or equivalent.
5 From 5 Hz to 20 Hz, maintaining 0.02 G2/Hz from 20 Hz to 500 Hz, all axes.
6 Test performed in end use equipment.
7 Refer to thermal de-rating curves found in the long form datasheet.
8 VID code lower than 1.25 V, use 5 A as minimum load.
9 The ‘Y’ suffix indicates that these parts are TSE RoHS 5/6 (non Pb-free) compliant.
10 NOTICE: Some models do not support all options. Please contact your local Artesyn representative or use the on-line
model number search tool at http://www.artesyn.com/powergroup/products.htm to find a suitable alternative.
Emerson Network Power.
The global leader in enabling
business-critical continuity.
AC Power
Connectivity
DC Power
Embedded Power
Inbound Power
Integrated Cabinet Solutions
Outside Plant
Precision Cooling
Site Monitoring and Services
EmersonNetworkPower. com
Emerson Network Power and the Emerson
Network Power logo are trademarks and
service marks of Emerson Electric Co.
©2007 Emerson Electric Co.