Film capacitors – Power electronic capacitors MKP PEC DC Series/Type: Ordering code: B2562* Date: Version: June 2010 3.2 Content of header bars 1 and 2 of data sheet will be automatically entered in headers and footers! Please fill in the table and then change the color to "white". This ensures that the table disappears (invisible) for the customer PDF. Don't change formatting when entering or pasting text in the table and don't add any cell or line in and to it! Identification/Classification 1 (header 1 + top left bar): Film capacitors – Power electronic capacitors Identification/Classification 2 (header 2 + bottom left header bar): MKP PEC DC Ordering code: (top right header bar) Series/Type: (bottom right header bar) B2562* Preliminary data (optional): (if necessary) Preliminary data Department: FK PEC Date: June 2010 Version: 3.2 EPCOS AG 2010. Reproduction, publication and dissemination of this publication, enclosures hereto and the information contained therein without EPCOS' prior express consent is prohibited. Film capacitors – Power electronic capacitors MKP PEC DC B2562* Preliminary data Metallized polypropylene film capacitors - aluminum case for general purpose applications B2562* Female terminals (M6, M8 or M10) B2562* Male terminals (M6, M8 or M10) M12 stud on bottom of the aluminum case, nut and washer for fixing are standard for all types. Others available distance between terminals: 35 and 50 mm. Observation: distance between terminals of 50 mm is available only for capacitors with diameter 116 mm. FK PEC June 2010 . Page 2 of 10 Film capacitors – Power electronic capacitors MKP PEC DC B2562* Preliminary data General Technical Information The following definitions apply to power capacitors according to IEC 61071. Rated capacitance CR Nominal value of the capacitance at 20 °C and measuring frequency range of 50 to 120 Hz. Rated DC voltage VR Maximum operating peak voltage of either polarity but of a non-reversing type wave form, for which the capacitor has been designed, for continuous operation. Ripple voltage Vr Peak-to-peak alternating component of the unidirectional voltage. Maximum surge voltage Vs Peak voltage induced by a switching or any other disturbance of the system which is allowed for a limited number of times and duration. - Maximum duration: 50 ms / pulse - Maximum number of occurrences: 1000 (during load) Insulation voltage Vi Rms rated value of the insulation voltage of capacitive elements and terminals to case or earth. When it is not specified in the product data sheet, the insulation voltage is at least: Vi = VR 2 Maximum rate of voltage rise (dV/dt)max Maximum permissible repetitive rate of voltage rise of the operational voltage. Maximum current Imax Maximum rms current for continuous operation. Maximum peak current Î Maximum permissible repetitive current amplitude during continuous operation. Maximum peak current (Î) and maximum rate of voltage rise (dV/dt)max on a capacitor are related as follows: Î = C (dV/dt)max Maximum surge current Î s Admissible peak current induced by a switching or any other disturbance of the system which is allowed for a limited number of times (1000 times) and duration (50 ms / pulse). Îs = C (dV/dt)s Ambient temperature ΘA Temperature of the surrounding air, measured at 10 cm distance and 2/3 of the case height of the capacitor. FK PEC June 2010 . Page 3 of 10 Film capacitors – Power electronic capacitors MKP PEC DC B2562* Preliminary data Lowest operating temperature Θmin Lowest permitted ambient temperature at which a capacitor may be energized. Maximum operating temperature Θmax Highest permitted capacitor temperature during operation, i.e. temperature at the hottest point of the case. Hot-spot temperature Θhs Temperature zone inside of the capacitor at hottest spot. Tangent of the loss angle of a capacitor tan δ Ratio between the equivalent series resistance and the capacitive reactance of a capacitor at a specified sinusoidal alternating voltage, frequency and temperature. Series resistance Rs The sum of all Ohmic resistances occurring inside the capacitor. Thermal resistance Rth The thermal resistance indicates by how many degrees the capacitor temperature at the hot spot rises in relation to the dissipation losses. Maximum power loss Pmax Maximum permissible power dissipation for the capacitor’s operation. Pmax = Θhs − Θ A R th Self inductance Lself The sum of all inductive elements which are contained in a capacitor. Resonance frequency fr The lowest frequency at which the impedance of the capacitor becomes minimum. fr = 1 2π ⋅ L self ⋅ CR Specifications and characteristics Application: The MKP DC series is designed for DC-link applications. Some typical examples of DC-Link applications are as follows: converters, frequency drives, power conversion, uninterruptible power supplies, transportation, wind power, solar power, power distribution, etc. FK PEC June 2010 . Page 4 of 10 Film capacitors – Power electronic capacitors MKP PEC DC B2562* Preliminary data Test data Voltage between terminals VTT: Voltage between terminals and case VTC: Dissipation factor tan δ at 100 Hz: Life test: Life expectancy tLD: 1.5 • VRDC, 10 s 2 • Vi + 1000 V, 10 s 1.0 • 10-3 IEC 61071 100 000 hours Climatic category Θstg: Θmin: Θmax: Θhs: Max. permissible humidity: 55/60/56 –55 °C ... +85 °C –55 °C +60 °C +75 °C 95% (ttest = 56 days) Construction and general data Resin filling: Non PCB, hard polyurethane (Dry type). Mounting and grounding: M12 Stud on bottom of the aluminum case. Cooling: Naturally air-cooled (or forced air cooling) Max. Permissible altitude: 2000 m above sea level Degree of protection: Indoor mounting Reference standards: IEC 61071 RoHS Compliance Mechanical characteristics Max. torque (case) M12 stud: Max. torque (terminal): 12 Nm 8 Nm FK PEC June 2010 . Page 5 of 10 Film capacitors – Power electronic capacitors MKP PEC DC B2562* Preliminary data Structure of Part number Special versions not necessarily are following the part number structure. FK PEC June 2010 . Page 6 of 10 Film capacitors – Power electronic capacitors MKP PEC DC B2562* Preliminary data Technical data and ordering codes Capacitance tolerance tan o tan (100 Hz) Θstg tLD VR V DC 880 1100 CR ±10% -4 2 • 10 -3 1 • 10 –55 ... +85 °C 100 000 h Ordering code F Imax Rs A m Lself Θmax D H nH °C mm mm 160 B25620B0167K881 40 2.2 80 50 75 70 220 B25620B0227K881 50 1.9 60 50 85 70 260 B25620B0267K881 45 2.8 80 50 75 95 260 B25620S0267K881 45 2.8 80 50 85 95 350 B25620B0357K881 50 2.4 60 50 85 95 400 B25620B0407K881 45 3.8 80 50 75 132 440 B25620B0447K882 65 1.5 60 50 116 70 480 B25620B0487K881 55 2.8 60 50 85 120 550 B25620B0557K881 50 3.0 60 50 85 132 700 B25620B0707K882 70 1.7 60 50 116 95 750 B25620B0757K881 55 3.7 60 50 85 173 970 B25620B0977K882 75 1.9 60 50 116 120 1100 B25620B0118K882 75 2.0 60 50 116 132 1500 B25620B0158K882 80 2.4 60 50 116 173 100 140 170 230 260 280 310 350 400 420 450 480 610 700 940 1100 1100 B25620B1107K101 B25620B1147K101 B25620B1177K101 B25620B1237K101 B25620B1267K101 B25620B1287K102 B25620B1317K101 B25620B1357K101 B25620B1407K101 B25620S1427A101 B25620B1457K102 B25620B1487K101 B25620B1617K102 B25620B1707K102 B25620B1947K102 B25620B1118K103 B25620S1118K103 35 45 40 40 40 60 50 40 55 55 65 50 70 70 70 80 80 2.5 2.1 3.2 4.1 4.4 1.6 3.2 5.6 2.4 2.2 1.9 4.3 2.2 2.3 1.6 1.5 1.5 80 60 80 80 80 60 60 80 60 60 60 60 60 60 60 100 100 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 75 85 75 75 75 116 85 75 85 85 116 85 116 116 116 116 116 70 70 95 120 132 70 120 173 132 138 95 173 120 132 173 223 230 FK PEC June 2010 . Page 7 of 10 Film capacitors – Power electronic capacitors MKP PEC DC B2562* Preliminary data VR V DC 1320 1980 CR Ordering code F Imax Rs A m Lself Θmax D H nH °C mm mm 70 70 B25620B1706K321 35 2.8 80 50 75 110 B25620B1117K321 35 3.8 80 50 75 95 160 B25620B1167K321 40 4.6 80 50 75 120 180 B25620B1187K321 40 5.1 80 50 75 132 220 B25620B1227K321 45 3.6 60 50 85 120 260 B25620B1267K321 45 3.9 60 50 85 132 310 B25620B1317K322 65 2.0 60 50 116 95 340 B25620B1347K321 50 4.9 60 50 85 173 420 B25620B1427K322 65 2.4 60 50 116 120 480 B25620B1487K322 70 2.6 60 50 116 132 660 B25620B1667K322 70 3.1 60 50 116 173 30 B25620B1306K981 25 3.8 80 50 75 70 40 B25620B1406K981 30 3.1 60 50 85 70 50 B25620B1506K981 30 5.1 80 50 75 95 70 B25620B1706K981 35 3.9 60 50 85 95 80 B25620B1806K981 30 7.1 80 50 75 132 110 B25620B1117K981 30 9.1 80 50 75 173 145 B25620B1147K981 40 7.1 60 50 85 173 190 B25620B1197K982 60 3.0 60 50 116 120 215 B25620B1217K982 60 3.3 60 50 116 132 295 B25620B1297K982 60 4.0 60 50 116 173 Other capacitances or voltage values are available upon request. FK PEC June 2010 . Page 8 of 10 Film capacitors – Power electronic capacitors MKP PEC DC B2562* Preliminary data Cautions and warnings In case of dents of more than 1 mm depth or any other mechanical damage, capacitors must not be used at all. Check tightness of the connections/terminals periodically. The energy stored in capacitors may be lethal. To prevent any chance of shock, discharge and short-circuit the capacitor before handling. Failure to follow cautions may result, worst case, in premature failures, bursting and fire. EPCOS AG is not responsible for any kind of possible damages to persons or things due to improper installation and application of capacitors for power electronics. Safety Electrical or mechanical misapplication of capacitors may be hazardous. Personal injury or property damage may result from bursting of the capacitor or from expulsion of oil or melted material due to mechanical disruption of the capacitor. Ensure good, effective grounding for capacitor enclosures. Observe appropriate safety precautions during operation (self-recharging phenomena and the high energy contained in capacitors). Handle capacitors carefully, because they may still be charged even after disconnection. The terminals of capacitors, connected bus bars and cables as well as other devices may also be energized. Follow good engineering practice. Thermal load After installation of the capacitor it is necessary to verify that maximum hot-spot temperature is not exceeded at extreme service conditions. Mechanical protection The capacitor has to be installed in a way that mechanical damages and dents in the aluminum can are avoided. Storage and operating conditions Do not use or store capacitors in corrosive atmosphere, especially where chloride gas, sulfide gas, acid, alkali, salt or the like are present. In dusty environments regular maintenance and cleaning especially of the terminals is required to avoid conductive path between phases and/or phases and ground. The maximum storage temperature is 85 °C. Service life expectancy Electrical components do not have an unlimited service life expectancy; this applies to self-healing capacitors, too. The maximum service life expectancy may vary depending on the application the capacitor is used in. FK PEC June 2010 . Page 9 of 10 Important notes The following applies to all products named in this publication: 1. Some parts of this publication contain statements about the suitability of our products for certain areas of application. These statements are based on our knowledge of typical requirements that are often placed on our products in the areas of application concerned. We nevertheless expressly point out that such statements cannot be regarded as binding statements about the suitability of our products for a particular customer application. As a rule, EPCOS is either unfamiliar with individual customer applications or less familiar with them than the customers themselves. For these reasons, it is always ultimately incumbent on the customer to check and decide whether an EPCOS product with the properties described in the product specification is suitable for use in a particular customer application. 2. We also point out that in individual cases, a malfunction of electronic components or failure before the end of their usual service life cannot be completely ruled out in the current state of the art, even if they are operated as specified. In customer applications requiring a very high level of operational safety and especially in customer applications in which the malfunction or failure of an electronic component could endanger human life or health (e.g. in accident prevention or life-saving systems), it must therefore be ensured by means of suitable design of the customer application or other action taken by the customer (e.g. installation of protective circuitry or redundancy) that no injury or damage is sustained by third parties in the event of malfunction or failure of an electronic component. 3. The warnings, cautions and product-specific notes must be observed. 4. In order to satisfy certain technical requirements, some of the products described in this publication may contain substances subject to restrictions in certain jurisdictions (e.g. because they are classed as hazardous). Useful information on this will be found in our Material Data Sheets on the Internet (www.epcos.com/material). Should you have any more detailed questions, please contact our sales offices. 5. We constantly strive to improve our products. Consequently, the products described in this publication may change from time to time. The same is true of the corresponding product specifications. Please check therefore to what extent product descriptions and specifications contained in this publication are still applicable before or when you place an order. We also reserve the right to discontinue production and delivery of products. Consequently, we cannot guarantee that all products named in this publication will always be available. The aforementioned does not apply in the case of individual agreements deviating from the foregoing for customer-specific products. 6. Unless otherwise agreed in individual contracts, all orders are subject to the current version of the “General Terms of Delivery for Products and Services in the Electrical Industry” published by the German Electrical and Electronics Industry Association (ZVEI). 7. The trade names EPCOS, BAOKE, Alu-X, CeraDiode, CSMP, CSSP, CTVS, DeltaCap, DigiSiMic, DSSP, FormFit, MiniBlue, MiniCell, MKD, MKK, MLSC, MotorCap, PCC, PhaseCap, PhaseCube, PhaseMod, PhiCap, SIFERRIT, SIFI, SIKOREL, SilverCap, SIMDAD, SiMic, SIMID, SineFormer, SIOV, SIP5D, SIP5K, ThermoFuse, WindCap are trademarks registered or pending in Europe and in other countries. Further information will be found on the Internet at www.epcos.com/trademarks. Page 10 of 10