Crydom MS11-CMX 3 -10 amp 0-200 vdc dc output Datasheet

Series MS11-CMX
3 -10 Amp • 0-200 Vdc • DC Output
DC output SPST-NO solid state relays
use MOSFET output for high switching
capabilities in a DIN Rail (TS-35) mount
air-cooled package.
• DIN Rail Mount (TS 35)
• MOSFET Output
• Extra Low On State
Resistance
• Input Status LED
MODEL NO.
MS11-CMX60D5
MS11-CMX60D10
MS11-CMX100D6
MS11-CMX200D3
INPUT SPECIFICATIONS 1
Control Voltage Range
5-10 Vdc
5-10 Vdc
5-10 Vdc
6-10 Vdc
Nominal Input Impedance
300 Ohm
300 Ohm
300 Ohm
300 Ohm
Typical Input Current @ 5 Vdc
12 mA
12 mA
12 mA
12 mA
Must Turn On Voltage
5 Vdc
5 Vdc
5 Vdc
6 Vdc
Must Turn Off Voltage
1.0 Vdc
1.0 Vdc
1.0 Vdc
1.0 Vdc
Operating Voltage Range
0-60 Vdc
0-60 Vdc
0-100 Vdc
0-200 Vdc
Load Current Range
0-5 Adc
0-10 Adc
0-6 Adc
0-3 Adc
Max. Surge Current, (10 msec)
60 Apk
100 Apk
100 Apk
30 Apk
Max.Off-State Leakage
@ Rated Voltage
100 µAdc
100 µAdc 4
100 µAdc
100 µAdc
Max. On-State Resistance
@ Rated Current (R DS-ON)
.10 Ohm
.018 Ohm
.040 Ohm
.20 Ohm
0.5V
0.18V
0.24V
0.6V
Max.Turn-On Time @ 10Vdc Control
1.0 msec
1.0 msec
1.0 msec
1.0 msec
Max. Turn-Off TIme @ 10Vdc Control
300 µsec
300 µsec
300 µsec
300 µsec
OUTPUT SPECIFICATIONS 1 3
Max. On-State Voltage Drop
@ Rated Current
© 2007 CRYDOM Inc., Specifications subject to change without notice.
GENERAL NOTES
1 All parameters at 25ºC unless otherwise specified.
2 Dielectric and insulation resistance are
measured between input and output.
3 Inductive loads should be diode suppressed.
4 At 55 Vdc.
SERIES MS11-CMX.
Rev. 110707
PAGE 1 OF 3
For recommended applications and more information contact:
USA: Sales Support (877) 502-5500 Tech Support (877) 702-7700 FAX (619) 710-8540
Crydom Inc., 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154
Email: [email protected] WEB SITE: http://www.crydom.com
UK: +44 (0)1202 606030 • FAX +44 (0)1202 606035 Crydom SSR Ltd., Arena Business Centre,
Holyrood Close, Poole, Dorset BH17 7FJ, Email: [email protected].
GERMANY: +49 (0)180 3000 506
Series MS11-CMX
3 -10 Amp • 0-200 Vdc • DC Output
GENERAL SPECIFICATIONS
Dielectric Strength 2
2500 Vrms
10 9 Ohm
Insulation Resistance (Min.) @ 500 Vdc 2
Max. Capacitance (Input/Output)
15 pF
Ambient Operating Temperature Range
-30 to 80°C
Ambient Storage Temperature Range
-30 to 125°C
MECHANICAL SPECIFICATIONS
Weight: (typical)
30 g
Encapsulation(SSR):
Thermally Conductive Epoxy
CURRENT DERATING CURVES
7.0
LOAD CURRENT [AMPS]
6.0
CMX100D6
5.0
4.0
CRYDOM
CMX60D5
Solid State Relay
3.0
2.0
Input
0
40
60
80
Output
54.0
1.0
20
-A2 +A1
CMX Series
CMX200D3
29.0
AMBIENT TEMPERATURE [ °C ]
LOAD CURRENT [AMPS]
12.0
DIN Rail TS35
10.0
8.0
85.0
CMX60D10
12.5
6.0
4.0
All dimensions are in millimeters (not to scale)
Colour of carrier including terminations - orange
2.0
0
20
40
60
80
AMBIENT TEMPERATURE [ °C ]
Max. Load Current vs. Temp.
© 2007 CRYDOM Inc., Specifications subject to change without notice.
APPROVALS (SSR ONLY)
UL E116950 (3A, 6A & 10A Models)
SERIES MS11-CMX.
Rev. 110707
PAGE 2 OF 3
For recommended applications and more information contact:
USA: Sales Support (877) 502-5500 Tech Support (877) 702-7700 FAX (619) 710-8540
Crydom Inc., 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154
Email: [email protected] WEB SITE: http://www.crydom.com
UK: +44 (0)1202 606030 • FAX +44 (0)1202 606035 Crydom SSR Ltd., Arena Business Centre,
Holyrood Close, Poole, Dorset BH17 7FJ, Email: [email protected].
GERMANY: +49 (0)180 3000 506
Series MS11-CX
5 Amp• 240 Vac• AC Output
Crydom's family of SPST-NO relays
achieves the highest power switching
capability in a DIN mounted air-cooled
package. Advanced features include
exceptional steady state current, plus
ultra-high surge ratings. Models are
available to switch up to 280 Vrms with
AC or DC control, and either zero-cross
or random turn-on ("R") switching versions.
• DIN Rail Mount (TS-35)
• SCR Output Rating
• Ultra High Surge
• Crydom’s Patented Design
• Input Status LED
MODEL NUMBERS
AC CONTROL (120Vac)
(24Vac)
MS11-CX2405A
MS11-CXE240A5
DC CONTROL
MS11-CX240D5
MS11-CXE240D5
OUTPUT SPECIFICATIONS 1
(5Vdc)
(24Vdc)
Operating Voltage (47-63 Hz) [Vrms]
12-280
Load Current Range [Arms]
.06-5
Transient Overvoltage [Vpk]
600
Max. Surge Current, (16.6ms) [Apk]
250
Max. On-State Voltage Drop @ Rated Current [Vpk]
1.4
Maximum I 2 t for Fusing, (8.3 msec.) [A 2 sec]
260
Max. Off-State Leakage Current @ Rated Voltage [mArms]
0.1
Min. Off-State dv/dt @ Max. Rated Voltage [V/µsec] 2
500
Max. Turn-On Time 3
1/2 Cycle (DC Control), 10.0 msec (AC Control)
Max. Turn-Off Time
1/2 Cycle (DC Control), 40.0 msec (AC Control)
0.5
Power Factor (Min.) with Max. Load
INPUT SPECIFICATIONS 1
DC CONTROL
24Vdc
5Vdc
Nominal Voltage
MODEL NUMBERS
MS11-CX240D5
MS11-CXE240D5
AC CONTROL 4
24Vac
120Vac
MS11-CX240A5
MS11-CXE240A5
Control Voltage Range
4-5 Vdc
15-32 Vdc
90-140 Vrms
18-36 Vrms
Max. Turn-On Voltage
3.0 Vdc
15.0 Vdc
90.0 Vrms
18.0 Vrms
Min. Turn-Off Voltage
1.0 Vdc
1.0 Vdc
10.0 Vrms
2.0 Vrms
Nominal Input Impedance
300 Ohm
1.0k Ohm
14.1k Ohm
4.2k Ohm
12 mA
8 mA
10 mArms
5 mArms
Typical Input Current @ Nominal Voltage
GENERAL NOTES
© 2005 CRYDOM CORP, Specifications subject to change without notice.
1 All parameters at 25ºC unless otherwise specified.
2 Off-State dv/dt test method per EIA/NARM standard RS-443, paragraph 13.11.1
3 Turn-On Time for Random Turn-On versions 0.1msec (DC Control Models).
4 No input status LED on AC control modules.
SERIES MS11-CX.
Rev. 012505
PAGE 1 OF 2
For recommended applications and more information contact:
USA: Sales Support (877) 502-5500 •Tech Support (877) 702-7700 • FAX (619) 710-8540
Crydom Corp, 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154
Email: [email protected] • WEB SITE: http://www.crydom.com
UK: +44 (0)1202 365070 • FAX: +44 (0)1202 365090 Crydom International Ltd., 7 Cobham
Road, Ferndown Industrial Estate, Ferndown, Dorset BH21 7PE, Email: [email protected].
GERMANY: +49 (0)180 3000 506
Series MS11-CX
5Amp • 240 Vac • AC Output
GENERAL SPECIFICATIONS
Dielectric Strength 50/60Hz Input/Output/Base
2500 Vrms
10 9 Ohm
Insulation Resistance (Min.) @ 500 Vdc
Max. Capacitance Input/Output
10 pF
Ambient Operating Temperature Range
-30 to 80ºC
Ambient Storage Temperature Range
-30 to 80ºC
MECHANICAL SPECIFICATION
Weight: (typical)
30 grms
Encapsulation (SSR):
Thermally Conductive Epoxy
CURRENT DERATING CURVE
CRYDOM
Solid State Relay
5.0
-A2 +A1
CX Series
4.0
Input
3.0
Output
54.0
2.0
29.0
LOAD CURRENT [AMPS]
6.0
1.0
0
20
40
60
80
DIN Rail TS35
AMBIENT TEMPERATURE [ C]
Max. Load Current vs. Temp.
85.0
12.5
All dimensions are in millimeters (not to scale)
Colour of carrier and termination housing - orange
Input status LED is on DC control module only
© 2005 CRYDOM CORP, Specifications subject to change without notice.
AVAILABLE OPTIONS
R
Random Turn-On Switching
Example: MS11-CX240D5R, MS11-CX240A5R
APPROVALS
( SSR ONLY )
UL
E 116949
CSA LR 81689
VDE 70938
UG (240V, DC Control Only)
SERIES MS11-CX
Rev. 012405
PAGE 2 OF 2
For recommended applications and more information contact:
USA: Sales Support (877) 502-5500 •Tech Support (877) 702-7700 • FAX (619) 710-8540
Crydom Corp, 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154
Email: [email protected] • WEB SITE: http://www.crydom.com
UK: +44 (0)1202 365070 • FAX: +44 (0)1202 365090 Crydom International Ltd., 7 Cobham
Road, Ferndown Industrial Estate, Ferndown, Dorset BH21 7PE, Email: [email protected].
GERMANY: +49 (0)180 3000 506
DANGER / PELIGRO / DANGER /GEFAHR / PERICOLO / PERIGO
HAZARD OF
ELECTRIC
SHOCK,
EXPLOSION,
OR ARC FLASH.
• Disconnect all
power before
installing or
working with
this equipment.
• Verify all
connections
and replace all
covers before
turning on
power.
Failure to follow
these
instructions will
result in death
or serious injury.
RIESGO DE
DESCARGA
ELECTRICA O
EXPLOSION.
• Desconectar
todos los
suministros de
energia a este
equipo antes
de trabajar
con este equipo.
• Verificar todas
las conexiones
y colocar todas
las tapas antes
de energizer
el equipo.
El
incumplimiento
de estas
instrucciones
puede provocar
la muerte o
lesiones serias.
RISQUE DE
DESCHARGE
ELECTRIQUE
OU EXPLOSION
• Eteindre
toutes les
sources
d'énergie de
cet appareil
avant de
travailler
dessus de cet
appareil
• Vérifier tous
connections, et
remettre tous
couverts en
olace avant de
mettre sous
De non-suivi de
ces instructions
provoquera la
mort ou des
lésions sérieuses
sérieuses.
GEFAHR EINES
ELEKTRISCHE
N SCHLAGES
ODER EINER
EXPLOSION.
• Stellen Sie
jeglichen
Strom ab, der
dieses Gerät
versorgt, bevor
Sie an dem
Gerät Arbeiten
durchführen
• Vor dem
Drehen auf
Energie alle
Anschlüsse
überprüfen
und alle
Abdeckungen
ersetzen.
RISCHIO DI
SCOSSA
ELETTRICA O
DELL’ESPLOSI
ONE.
• Spenga tutta
l'alimentazion
e che fornisce
questa
apparecchiatu
ra prima del
lavorare a questa
apparecchiatu ra
• Verificare tutti
i collegamenti
e sostituire
tutte le coperture
prima della
rotazione
sull'alimentazi one
Unterlassung
dieser
Anweisungen
können zum
Tode oder zu
schweren
Verletzungen
führen.
L'omissione di
seguire queste
istruz ioni
provocherà la
morte o di
lesioni serie
RISCO DE
DESCARGA
ELÉTTRICA OU
EXPLOSÃO
• Desconectar
o equipamento
de toda á
energia antes
de instalar ou
trabalhar com
este equipamen
to
• Verificar todas
as conexões e
recolocar todas
as tampas
antes de religar
o equipamento
O não cumprimento
destas instruções
pode levar á morte
ou lesões sérias.
WARNING / AVERTISSEMENT / WARNUNG /ADVERTENCIA / AVVERTENZA / AVISO
RISK OF MATERIAL DAMAGE AND HOT
ENCLOSURE
RISQUE DE DOMMAGE MATERIEL ET DE
SURCHAUFFE DU BOITIER
GEFAHR VON MATERIALSCHÄDEN UND
GEHÄUSEERHITZUNG
• The product's side panels may be hot, allow
time for product to cool before touching.
• Follow proper mounting instructions including
torque values.
• Do not allow liquids or foreign objects to enter
this product.
• Les panneaux latéraux du produit peuvent être
chauds. Laisser le produit refroidir avant de le
toucher.
• Respecter les consignes de montage, et
notamment les couples de serrage.
• Ne pas laisser pénétrer de liquide ni de corps
étrangers à l'intérieur du produit.
• Die Seitenwände können heiß sein. Lassen Sie
das Produkt abkühlen, bevor Sie es berühren.
• Beachten Sie die Montageanweisungen,
• Führen Sie keine Flüssigkeiten oder
Fremdkörper in das Produkt ein.
Failure to follow this instruction can result in
serious injury, or equipment damage.
Le non-respect de cette directive peut entraîner,
des lésions corporelles graves ou des
dommages matériels.
Die Nichtbeachtung dieser Anweisung kann
Körperverletzung oder Materialschäden
zur Folge haben.
RISCHIO DI DANNI MATERIALI E D'INVOLUCRO
CALDO
RISCO DE DANO MATERIAL E DE AQUECIMENTO
RIESGO DE DAÑOS MATERIALES Y DE
SOBRECALENTAMIENTO DE LA UNIDAD
• Los paneles laterales del producto pueden
estar calientes. Esperar que el producto se
enfríe antes de tocarlo.
• Respetar las instrucciones de montaje, y en
particular los pares de apretado.
• No dejar que penetren líquidos o cuerpos
extraños en el producto.
• I pannelli laterali dell'apparecchio possono
scottare; lasciar quindi raffreddare il prodotto
prima di toccarlo.
• Seguire le istruzioni di montaggio corrette.
• Non far entrare liquidi o oggetti estranei in questo
apparecchio.
Si no se respetan estas precauciones pueden
producirse graves lesiones, daños materiales.
La mancata osservanza di questa precauzione può
causare gravi rischi per l'incolumità personale o
danni alle apparecchiature.
SERIES MS11-CMX.
Rev. 110707
PAGE 3 OF 3
• Os painéis laterais do produto podem estar
quentes; dê tempo ao produto para arrefecer
antes de lhe tocar.
• Siga devidamente as instruções de montagem.
• Não permita a entrada de líquidos e de objectos
estranhos no produto.
A não observância destas precauções pode
provocar a morte, ferimentos graves ou
danos materiais.
ANNEX – ENVIRONMENTAL INFORMATION:
The environmental information disclosed in this annex including the EIP
Pollution logo are in compliance with People’s Republic of China Electronic
Industry Standard SJ/T11364 – 2006, Marking for Control of Pollution
Caused by Electronic Information Products.
Part
Toxic or hazardous Substance and Elements
Name
Lead Mercury Cadmium Hexavalent Polybrominated Polybrominated
(Pb) (Hg)
(Cd)
Chromium
biphenyls
diphenyl ethers
(Cr (VI))
(PBB)
(PBDE)
Semiconductor
X
O
O
O
O
O
die
Solder
X
O
O
O
O
O
䰘ӊ - ⦃ֱֵᙃ:
䚼ӊ
ৡ⿄
ञᇐԧ㢃⠛
⛞᥹⚍
ℸ䰘ӊ᠔ᷛ⼎ⱘࣙᣀ⬉ᄤֵᙃѻક∵ᶧ೒ᷛⱘ⦃ֱֵᙃ
ヺড়ЁढҎ⇥݅੠೑⬉ᄤ㸠Ϯᷛ‫ ޚ‬SJ/T11364 - 2006, ⬉ᄤֵᙃѻક∵ᶧ᥻ࠊᷛ䆚㽕∖
᳝↦᳝ᆇ⠽䋼៪‫ܗ‬㋴
䪙
∲
䬝
݁Ӌ䫀
໮⒈㘨㣃
໮⒈Ѡ㣃䝮
(Pb) (Hg) (Cd) (Cr (VI))
(PBB)
(PBDE)
X
O
O
O
X
O
O
O
O
O
O
O
© 2007 CRYDOM Inc., Specifications subject to change without notice.
Similar pages