The MBC120 Series of open frame medical power supplies feature a wide universal AC input range of 85 V – 264 VAC, offering 120 W of output power in a compact footprint, with a variety of isolated single output voltages. 3 x 2 Footprint 120 Watts with Forced Air Cooling Approval to EN60601 3rd Edition Efficiencies up to 93% -40 To 70 Degree Operating Temperature Dual Fusing Thermal Shut-Down Feature >3.00 Million Hours, Telcordia -SR332-Issue 3 Standby Power < 0.3W Class II Option Available RoHS Compliant CE Marked The MBC series was designed to 3rd edition medical approvals and provides 2x MOPP (Means of Patient Protection) isolation for Class I and Class II installations. These power supplies are ideal for medical, telecom, Datacom, industrial equipment and other applications. Diagnostic Drug Pump Dialysis Home Health Care Monitoring Portable Equipment North America +1-866.513.2839 Asia-Pacific +86.755.29885888 Europe, Middle East +353 61 225 977 [email protected] © 2015 Bel Power Solutions, Inc. BCD.00667_001 MBC120 Series MODEL NUMBER2 MBC120-1T12L MBC120-1012L MBC120-1T15L MBC120-1015L MBC120-1T24L MBC120-1024L MBC120-1T30L MBC120-1030L MBC120-1T48L MBC120-1048L MBC120-1T58L MBC120-1058L COVER-120-XBC 1 2 DESCRIPTION Screw Terminal Molex Header Screw Terminal Molex Header Screw Terminal Molex Header Screw Terminal Molex Header Screw Terminal Molex Header Screw Terminal Molex Header metal cover kit accessory VOLTAGE MAX. LOAD (CONVECTION) MAX. LOAD (200 LFM) MIN. LOAD RIPPLE & NOISE 1 12 V 8.33 A 10.0 A 0.0 A 1% 15 V 6.66 A 8.0 A 0.0 A 1% 24 V 4.16 A 5.0 A 0.0 A 1% 30 V 3.33 A 4.0 A 0.0 A 1% 48 V 2.08 A 2.5 A 0.0 A 1% 58 V 1.72 A 2.07 A 0.0 A 1% Ripple is peak to peak with 20 MHz bandwidth and 10 μF (Tantalum capacitor) in parallel with a 0.1 μF capacitor at rated line voltage and load ranges. For Class II Option (without input Earth pin) add suffix: -2 (e.g.: MBC120-1012L-2). 866.513.2839 [email protected] © 2015 Bel Power Solutions, Inc. BCD.00667_001 MBC120 Series Specifications are for nominal input voltage, 25°C unless otherwise stated. PARAMETER DESCRIPTION / CONDITION SPECIFICATION Input Voltage Universal (see derating under output power) 85-264 VAC / 390 VDC3 Power Factor 115 VAC: 230 VAC: Typical 115 VAC: 230 VAC: 264 VAC: Typical (N.A. For Class II Option) Touch current @ Full Load 47-63 Hz 1.2 A max. 0.65 A max. < 0.3 W 25 A 45 A 75 A 300 uA <100 uA > 0.95 Switching Frequency Typical 60 KHz DESCRIPTION / CONDITION With 200 LFM: Convection: 48 V, 58 V: 24 V, 30 V: 12 V, 15 V: Typical SPECIFICATION 120 W Up to 100 W 93% 91% 90% >10 ms Input Frequency Input Current No Load Power Inrush Current Leakage Current 3 Functional, not approved. PARAMETER Output Power Efficiency Hold-up Time Line Regulation +/-0.5% Load Regulation Transient Response +/-1% 25% step load change, at 0.1A/uS slew rate, 50% duty cycle, 50 Hz = 4% Voltage Adjustment Rise Time Typical recovery time < 5 ms +/-3% 55 ms Set Point Tolerance +/-1% Over Current Protection > 110% Over Voltage Protection Latch type (AC recycling required) Short Circuit Protection Hiccup mode PARAMETER DESCRIPTION / CONDITION Operating Temperature 110 to 140% Startup guaranteed, derate linearly above 50°C to 70°C as per Fig 1. Storage Temperature Cooling Relative Humidity Altitude Reliability Forced: with 300 LFM (Refer to Mech. Drawing) Convection: for input 100-264 VAC (derate linearly to 80W @ 85VAC) Noncondensing Operating: Nonoperating: MTBF according to Telcordia -SR332-Issue 3 SPECIFICATION -40 to +70°C -40 to 0°C -40 to +85°C 120 W 100 W 5% to 95% 16,000 ft 40,000 ft. 3.00 million hours 866.513.2839 [email protected] © 2015 Bel Power Solutions, Inc. BCD.00667_001 MBC120 Series PARAMETER DESCRIPTION / CONDITION Conducted Emissions EN55022-B, CISPR22-B, FCC PART15 - B Static Discharge EN61000-4-2: Level-3 RF Field Susceptibility EN61000-4-3: Level-3 Fast Transients/Bursts Level-3 Level A Level B Surge Susceptibility EN61000-4-4: Radiated: Radiated with external core: (King core K5B RC 25x12x15-M in input cable with 5 Turns) EN61000-4-5: Harmonic Current EN61000-3-2: Class D PARAMETER SPECIFICATION 4000 VAC 1500 VAC 1500 VAC 500 VAC Agency Approvals DESCRIPTION / CONDITION Input to Output: (For medical applications) Input to GND: (Not Applicable For Class II Option) Output to GND: for type BF for type B (N/A For Class II Option) Approved to the latest edition of the following standards: CSA/UL60601-1, EN60601-1 and IEC60601-1. Nemko, UL, C-UL CE mark Complies with LVD Directive Radiated Emissions Isolation Voltage Safety Standard(s) SPECIFICATION Level-3 Figure 1 – Derating Curve CONNECTOR AC Input Connector DC Output Connector PIN J1 J2 DESCRIPTION / CONDITION Pin 1 Pin 2 Pin 3 AC Line Not Fitted AC Neutral Pin 1, 2 Pin 3, 4 V1 +VE V1 - VE Screw Terminal (Option 1) Molex Header (Option 2) Screw Terminal (Option 1) Molex Header (Option 2) MANUFACTURER / PN Molex: 39357-0003 Tyco-2-1776112-3 Molex: 1722861103 (Mating conn: Molex 1722561003) Molex: 39357-0004 Tyco-2-1776112-4 Molex: 1722861104 (Mating conn: Molex 1722561004) 866.513.2839 [email protected] © 2015 Bel Power Solutions, Inc. BCD.00667_001 MBC120 Series PARAMETER DESCRIPTION / CONDITION Weight 150 g Dimensions 76.2 x 50.8 x 30.1 mm (3 x 2 x 1.18 inch) Figure 2 - Mechanical Drawing - Screw Terminal (Option 1) 866.513.2839 [email protected] © 2015 Bel Power Solutions, Inc. BCD.00667_001 MBC120 Series Figure 3 - Mechanical Drawing - Molex Header (Option 2) NUCLEAR AND MEDICAL APPLICATIONS - Products are not designed or intended for use as critical components in life support systems, equipment used in hazardous environments, or nuclear control systems. TECHNICAL REVISIONS - The appearance of products, including safety agency certifications pictured on labels, may change depending on the date manufactured. Specifications are subject to change without notice. 866.513.2839 [email protected] © 2015 Bel Power Solutions, Inc. BCD.00667_001