LTC1290 Single Chip 12-Bit Data Acquisition System U FEATURES DESCRIPTIO ■ The LTC®1290 is a data acquisition component which contains a serial I/O successive approximation A/D converter. It uses LTCMOSTM switched capacitor technology to perform either 12-bit unipolar or 11-bit plus sign bipolar A/D conversions. The 8-channel input multiplexer can be configured for either single-ended or differential inputs (or combinations thereof). An on-chip sample-and-hold is included for all single-ended input channels. When the LTC1290 is idle it can be powered down with a serial word in applications where low power consumption is desired. ■ ■ ■ ■ ■ Software Programmable Features – Unipolar/Bipolar Conversion – Four Differential/Eight Single-Ended Inputs – MSB- or LSB-First Data Sequence – Variable Data Word Length – Power Shutdown Built-In Sample-and-Hold Single Supply 5V or ±5V Operation Direct Four-Wire Interface to Most MPU Serial Ports and All MPU Parallel Ports 50kHz Maximum Throughput Rate Available in 20-Lead PDIP and SO Wide Packages U KEY SPECIFICATIO S ■ ■ ■ Resolution: 12 Bits Fast Conversion Time: 13µs Max Over Temp Low Supply Current: 6.0mA The serial I/O is designed to be compatible with industry standard full duplex serial interfaces. It allows either MSBor LSB-first data and automatically provides 2's complement output coding in the bipolar mode. The output data word can be programmed for a length of 8, 12 or 16 bits. This allows easy interface to shift registers and a variety of processors. , LTC and LT are registered trademarks of Linear Technology Corporation. LTCMOS is a trademark of Linear Technology Corporation. All other trademarks are the property of their respective owners. Protected by U.S. Patents, including 5287525. U TYPICAL APPLICATIO 12-Bit 8-Channel Sampling Data Acquisition System SINGLE-ENDED INPUT 0V TO 5V OR ±5V ±15V OVERVOLTAGE RANGE* 1k • • • VCC CH0 CH1 ACLK CH2 SCLK CH3 DIN DIFFERENTIAL INPUT (+) CH4 DOUT ±5V COMMON MODE RANGE (–) CH5 CS CH6 REF + CH7 REF – COM V– • • • LTC1290 DGND + 5V 22µF TANTALUM 1N5817 TO AND FROM MICROPROCESSOR 1N4148 4.7µF TANTALUM + LT ®1027 8V TO 40V 1µF –5V AGND 1N5817 0.1µF 1290 • TA01 * FOR OVERVOLTAGE PROTECTION ON ONLY ONE CHANNEL LIMIT THE INPUT CURRENT TO 15mA. FOR OVERVOLTAGE PROTECTION ON MORE THAN ONE CHANNEL LIMIT THE INPUT CURRENT TO 7mA PER CHANNEL AND 28mA FOR ALL CHANNELS. (SEE SECTION ON OVERVOLTAGE PROTECTION IN THE APPLICATIONS INFORMATION SECTION.) CONVERSION RESULTS ARE NOT VALID WHEN THE SELECTED OR ANY OTHER CHANNEL IS OVERVOLTAGED (VIN < V – OR VIN > VCC). 1290fe 1 LTC1290 W W W AXI U U ABSOLUTE RATI GS (Notes 1, 2) – Supply Voltage (VCC) to GND or V ........................ 12V Operating Temperature Range – Negative Supply Voltage (V ) .................... – 6V to GND LTC1290BC, LTC1290CC, LTC1290DC .... Voltage Analog/Reference Inputs ......... (V –) – 0.3V to VCC + 0.3V Digital Inputs ........................................ – 0.3V to 12V Digital Outputs ........................... – 0.3V to VCC + 0.3V Power Dissipation ............................................. 500mW 0°C to 70°C LTC1290BI, LTC1290CI, LTC1290DI .... – 40°C to 85°C LTC1290BM, LTC1290CM, LTC1290DM (OBSOLETE) ............ – 55°C to 125°C Storage Temperature Range ................ – 65°C to 150°C Lead Temperature (Soldering, 10 sec.)................ 300°C U W U PACKAGE/ORDER I FOR ATIO TOP VIEW TOP VIEW CH0 1 20 VCC CH0 1 20 VCC CH1 2 19 ACLK CH1 2 19 ACLK CH2 3 18 SCLK CH2 3 18 SCLK CH3 4 17 DIN CH3 4 17 DIN CH4 5 16 DOUT CH4 5 16 DOUT CH5 6 15 CS CH5 6 15 CS CH6 7 14 REF + CH6 7 14 REF + CH7 8 13 REF – COM 9 CH7 8 13 REF – V– COM 9 12 V – 11 AGND DGND 10 12 DGND 10 N PACKAGE 20-LEAD PDIP TJMAX = 110°C, θJA = 100°C/W (N) ORDER PART NUMBER N PART MARKING LTC1290BIN LTC1290CIN LTC1290DIN LTC1290BCN LTC1290CCN LTC1290DCN 11 AGND SW PACKAGE 20-LEAD PLASTIC SO WIDE TJMAX = 110°C, θJA = 130°C/W (SW) ORDER PART NUMBER SW PART MARKING LTC1290BCSW LTC1290CCSW LTC1290DCSW LTC1290BISW LTC1290CISW LTC1290DISW J PACKAGE 20-LEAD CERAMIC DIP TJMAX = 150°C, qJA = 80°C/W (J) LTC1290BMJ LTC1290CMJ LTC1290DMJ LTC1290BIJ LTC1290CIJ LTC1290DIJ OBSOLETE PACKAGE Consider N Package for Alternate Source Order Options Tape and Reel: Add #TR Lead Free: Add #PBF Lead Free Tape and Reel: Add #TRPBF Lead Free Part Marking: http://www.linear.com/leadfree/ *The temperature grade is identified by a label on the shipping container. Consult LTC Marketing for parts specified with wider operating temperature ranges. 1290fe 2 LTC1290 U U W CO VERTER A D ULTIPLEXER CHARACTERISTICS The ● denotes the specifications which apply over the full operating temperature range, otherwise specifications are at TA = 25°C. (Note 3) LTC1290D TYP MAX UNITS ±1.5 ±1.5 LSB ±0.5 ±0.5 ±0.75 LSB ● ±0.5 ±1.0 ±4.0 LSB ● 12 12 12 Bits CONDITIONS Offset Error (Note 4) ● ±1.5 Linearity Error (INL) (Notes 4, 5) ● Gain Error (Note 4) Minimum Resolution for Which No Missing Codes are Guaranteed MIN LTC1290B TYP MAX PARAMETER MIN LTC1290C TYP MAX MIN (V – ) – 0.05V to VCC + 0.05V (V – ) – 0.05V to VCC + 0.05V (V – ) – 0.05V to VCC + 0.05V Analog and REF Input Range (Note 7) On Channel Leakage Current (Note 8) On Channel = 5V Off Channel = 0V ● ±1 ±1 ±1 µA On Channel = 0V Off Channel = 5V ● ±1 ±1 ±1 µA On Channel = 5V Off Channel = 0V ● ±1 ±1 ±1 µA On Channel = 0V Off Channel = 5V ● ±1 ±1 ±1 µA Off Channel Leakage Current (Note 8) V 1290fe 3 LTC1290 AC CHARACTERISTICS The ● denotes the specifications which apply over the full operating temperature range, otherwise specifications are at TA = 25°C. (Note 3) LTC1290B/LTC1290C/LTC1290D MIN TYP MAX SYMBOL PARAMETER CONDITIONS fSCLK Shift Clock Frequency VCC = 5V (Note 6) 0 fACLK A/D Clock Frequency VCC = 5V (Note 6) (Note 10) tACC Delay Time from CS↓ to DOUT Data Valid (Note 9) 2 ACLK Cycles tSMPL Analog Input Sample Time See Operating Sequence 7 SCLK Cycles tCONV Conversion Time See Operating Sequence 52 ACLK Cycles tCYC Total Cycle Time See Operating Sequence (Note 6) tdDO Delay Time, SCLK↓ to DOUT Data Valid See Test Circuits LTC1290BC, LTC1290CC ● LTC1290DC, LTC1290BI LTC1290CI, LTC1290DI 130 220 ns LTC1290BM, LTC1290CM ● LTC1290DM (OBSOLETE) 180 270 ns 70 100 ns 130 200 ns 2.0 4.0 12 SCLK + 56 ACLK tdis Delay Time, CS↑ to DOUT Hi-Z See Test Circuits ● ten Delay Time, 2nd ACLK↓ to DOUT Enabled See Test Circuits ● thCS Hold Time, CS After Last SCLK↓ VCC = 5V (Note 6) 0 thDI Hold Time, DIN After SCLK↑ VCC = 5V (Note 6) 50 thDO Time Output Data Remains Valid After SCLK↓ tf DOUT Fall Time tr tsuDI ● DOUT Rise Time See Test Circuits ● Setup Time, DIN Stable Before SCLK↑ VCC = 5V (Note 6) tsuCS Setup Time, CS↓ Before Clocking in First Address Bit (Notes 6, 9) tWHCS CS High Time During Conversion VCC = 5V (Note 6) CIN Input Capacitance Analog Inputs On Channel Analog Inputs Off Channel Digital Inputs MHz MHz Cycles ns ns 50 See Test Circuits UNITS ns 65 130 25 50 50 ns ns ns 2 ACLK Cycles + 100ns 52 ACLK Cycles 100 5 pF pF 5 pF 1290fe 4 LTC1290 U DIGITAL A D DC ELECTRICAL CHARACTERISTICS The ● denotes the specifications which apply over the full operating temperature range, otherwise specifications are at TA = 25°C. (Note 3) LTC1290B/LTC1290C/LTC1290D MIN TYP MAX SYMBOL PARAMETER CONDITIONS VIH High Level Input Voltage VCC = 5.25V ● VIL Low Level Input Voltage VCC = 4.75V ● IIH High Level Input Current VIN = VCC IIL Low Level Input Current VIN = 0V VOH High Level Output Voltage VCC = 4.75V 2.0 UNITS V 0.8 V ● 2.5 µA ● – 2.5 µA IO = 10µA IO = 360µA ● IO = 1.6mA ● 0.4 V ● ● 3 –3 µA µA 2.4 4.7 4.0 V V VOL Low Level Output Voltage VCC = 4.75V IOZ High-Z Output Leakage VOUT = VCC, CS High VOUT = 0V, CS High ISOURCE Output Source Current VOUT = 0V –20 mA ISINK Output Sink Current VOUT = VCC 20 mA ICC Positive Supply Current CS High ● 6 12 mA CS High LTC1290BC, LTC1290CC Power Shutdown LTC1290DC, LTC1290BI ACLK Off LTC1290CI, LTC1290DI ● 5 10 µA LTC1290BM, LTC1290CM ● LTC1290DM (OBSOLETE) 5 15 µA IREF Reference Current VREF = 5V ● 10 50 µA I– Negative Supply Current CS High ● 1 50 µA Note 1: Absolute Maximum Ratings are those values beyond which the life of a device may be impaired. Note 2: All voltage values are with respect to ground with DGND, AGND and REF – wired together (unless otherwise noted). Note 3: VCC = 5V, VREF + = 5V, VREF – = 0V, V – = 0V for unipolar mode and – 5V for bipolar mode, ACLK = 4.0MHz unless otherwise specified. Note 4: These specs apply for both unipolar and bipolar modes. In bipolar mode, one LSB is equal to the bipolar input span (2VREF) divided by 4096. For example, when VREF = 5V, 1LSB (bipolar) = 2(5V)/4096 = 2.44mV. Note 5: Integral nonlinearity is defined as the deviation of a code from a straight line passing through the actual endpoints of the transfer curve. The deviation is measured from the center of the quantization band. Note 6: Recommended operating conditions. Note 7: Two on-chip diodes are tied to each reference and analog input which will conduct for reference or analog input voltages one diode drop below V – or one diode drop above VCC. Be careful during testing at low VCC levels (4.5V), as high level reference or analog inputs (5V) can cause this input diode to conduct, especially at elevated temperatures and cause errors for inputs near full scale. This spec allows 50mV forward bias of either diode. This means that as long as the reference or analog input does not exceed the supply voltage by more than 50mV, the output code will be correct. To achieve an absolute 0V to 5V input voltage range will therefore require a minimum supply voltage of 4.950V over initial tolerance, temperature variations and loading. Note 8: Channel leakage current is measured after the channel selection. Note 9: To minimize errors caused by noise at the chip select input, the internal circuitry waits for two ACLK falling edge after a chip select falling edge is detected before responding to control input signals. Therefore, no attempt should be made to clock an address in or data out until the minimum chip select setup time has elapsed. Note 10: Increased leakage currents at elevated temperatures cause the S/H to droop, therefore it's recommended that fACLK ≥ 125kHz at 85°C and fACLK ≥ 15kHz at 25°C. 1290fe 5 LTC1290 U W TYPICAL PERFOR A CE CHARACTERISTICS 18 14 10 6 8 7 6 5 4 6 8 SUPPLY VOLTAGE, VCC (V) 10 CHANGE IN GAIN ERROR (LSB = 1 • VREF) 4096 1.25 VCC = 5V LINEARITY ERROR (LSB = 1 • VREF) 4096 0.5 1.00 0.75 0.50 0.25 0.3 5 –0.2 –0.3 –0.4 VCC = 5V 1 3 2 4 REFERENCE VOLTAGE, VREF (V) 5 0.4 0.2 0.1 0 –50 –30 –10 10 30 50 70 90 110 130 AMBIENT TEMPERATURE, TA (°C) 1290 • TPC07 MAGNITUDE OF GAIN CHANGE ⏐∆GAIN⏐ (LSB) 0.3 ACLK = 4MHz VCC = 5V VREF = 5V 0.3 0.2 0.1 0 –50 –30 –10 10 30 50 70 90 110 130 AMBIENT TEMPERATURE, TA (°C) 1290 • TPC06 Change in Gain Error vs Temperature Maximum ACLK Frequency vs Source Resistance 5 0.5 0.4 5 0.5 1290 • TPC05 Change in Linearity Error vs Temperature 0.4 3 2 4 REFERENCE VOLTAGE, VREF (V) Change in Offset vs Temperature –0.1 1290 • TPC04 ACLK = 4MHz VCC = 5V VREF = 5V VOS = 0.125mV 0.2 1290 • TPC03 0 –0.5 0 0.6 VOS = 0.25mV 0.4 Change in Gain vs Reference Voltage Change in Linearity vs Reference Voltage 1 3 4 2 REFERENCE VOLTAGE, VREF (V) 0.6 LT1290 • TPC02 1290 • TPC01 0 0.7 1 ACLK = 4MHz VCC = 5V VREF = 5V MAXIMUM ACLK FREQUENCY* (MHz) 4 0.8 0.1 3 –50 –30 –10 10 30 50 70 90 110 130 AMBIENT TEMPERATURE, TA (°C) 2 MAGNITUDE OF LINEARITY CHANGE ⏐∆LINEARITY⏐ (LSB) VCC = 5V MAGNITUDE OF OFFSET CHANGE ⏐∆OFFSET⏐ (LSB) 22 9 ACLK = 4MHz VCC = 5V OFFSET ERROR (LSB = 1 • VREF) 4096 ACLK = 4MHz TA = 25°C SUPPLY CURRENT, ICC (mA) SUPPLY CURRENT, ICC (mA) 0.9 10 26 0.5 Unadjusted Offset Voltage vs Reference Voltage Supply Current vs Temperature Supply Current vs Supply Voltage 0.3 0.2 0.1 0 –50 –30 –10 10 30 50 70 90 110 130 AMBIENT TEMPERATURE, TA (°C) 1290 • TPC08 VCC = 5V VREF = 5V TA = 25°C 4 3 VIN RSOURCE – + INPUT – INPUT 2 1 0 100 1k 10 k RSOURCE (Ω) 100k 1290 • TPC09 * MAXIMUM ACLK FREQUENCY REPRESENTS THE ACLK FREQUENCY AT WHICH A 0.1LSB SHIFT IN THE ERROR AT ANY CODE TRANSITION FROM ITS 4MHz VALUE IS FIRST DETECTED. 1290fe 6 LTC1290 U W TYPICAL PERFOR A CE CHARACTERISTICS Maximum Filter Resistor vs Cycle Time Sample-and-Hold Acquisition Time vs Source Resistance 100 1k 100 RFILTER + VIN CFILTER ≥ 1µF 10 – 1.0 10 1000 100 VIN 10 RSOURCE+ + 1k 140 120 100 80 60 40 20 0 3.00 1.00 2.00 ACLK FREQUENCY (MHz) 4.00 4 3 2 1290 • TPC12 Noise Error vs Reference Voltage 2.25 900 GUARANTEED 800 700 600 500 400 300 200 100 ON CHANNEL OFF CHANNEL 0 –50 –30 –10 10 30 50 70 90 110 130 AMBIENT TEMPERATURE, TA (°C) 1290 • TPC13 1290 • TPC14 PEAK-TO-PEAK NOISE ERROR (LSBs) 160 5 Input Channel Leakage Current vs Temperature INPUT CHANNEL LEAKAGE CURRENT (nA) VCC = 5V CMOS LEVELS 6 LTC1290 • TPC11 1000 180 7 0 –50 –30 –10 10 30 50 70 90 110 130 AMBIENT TEMPERATURE, TA (°C) 10k RSOURCE+ (Ω) Supply Current (Power Shutdown) vs ACLK 200 8 1 1 100 10000 ACLK OFF DURING POWER SHUTDOWN 9 – CYCLE TIME, tCYC (µs) 1290 • TPC10 ** MAXIMUM RFILTER REPRESENTS THE FILTER RESISTOR VALUE AT WHICH A 0.1LSB CHANGE IN FULL-SCALE ERROR FROM ITS VALUE AT RFILTER = 0 IS FIRST DETECTED. SUPPLY CURRENT, ICC (µA) 10 VREF = 5V VCC = 5V TA = 25°C 0V TO 5V INPUT STEP SUPPLY CURRENT, ICC (µA) S & H AQUISITION TIME TO 0.02% (µs) MAXIMUM RFILTER** (Ω) 10k Supply Current (Power Shutdown) vs Temperature LTC1290 NOISE 200µVP-P 2.00 1.75 1.50 1.25 1.00 0.75 0.50 0.25 0 0 4 1 3 2 REFERENCE VOLTAGE, VREF (V) 5 1290 • TPC15 U U U PI FU CTIO S CH0 to CH7 (Pin 1 to Pin 8): Analog Inputs. The analog inputs must be free of noise with respect to AGND. COM (Pin 9): Common. The common pin defines the zero reference point for all single-ended inputs. It must be free of noise and is usually tied to the analog ground plane. DGND (Pin 10): Digital Ground. This is the ground for the internal logic. Tie to the ground plane. AGND (Pin 11): Analog Ground. AGND should be tied directly to the analog ground plane. V – (Pin 12): Negative Supply. Tie V – to most negative potential in the circuit. (Ground in single supply applications.) REF –, REF + (Pins 13, 14): Reference Inputs. The reference inputs must be kept free of noise with respect to AGND. CS (Pin 15): Chip Select Input. A logic low on this input enables data transfer. DOUT (Pin 16): Digital Data Output. The A/D conversion result is shifted out of this output. 1290fe 7 LTC1290 U U U PI FU CTIO S DIN (Pin 17): Digital Data Input. The A/D configuration word is shifted into this input after CS is recognized. ACLK (Pin 19): A/D Conversion Clock. This clock controls the A/D conversion process. SCLK (Pin 18): Shift Clock. This clock synchronizes the serial data transfer. VCC (Pin 20): Positive Supply. This supply must be kept free of noise and ripple by bypassing directly to the analog ground plane. BLOCK DIAGRAM VCC DIN 18 20 INPUT SHIFT REGISTER 17 CH0 CH1 CH2 CH3 CH4 CH5 CH6 CH7 COM OUTPUT SHIFT REGISTER 16 SCLK DOUT 1 SAMPLEANDHOLD 2 3 COMP 4 5 ANALOG INPUT MUX 12-BIT SAR 6 12-BIT CAPACITIVE DAC 7 8 9 19 10 11 DGND AGND 12 V– 13 REF – CONTROL AND TIMING 14 REF+ 15 ACLK CS LTC1290 • BD TEST CIRCUITS On and Off Channel Leakage Current Load Circuit for tdis and ten 5V ION TEST POINT ON CHANNEL A IOFF 3k 5V WAVEFORM 2 DOUT A • • • • OFF CHANNELS 100pF WAVEFORM 1 LTC1290 • TC02 POLARITY LTC1290 • TC01 1290fe 8 LTC1290 TEST CIRCUITS Voltage Waveforms for DOUT Delay Time, tdDO SCLK 0.8V tdDO 2.4V DOUT 0.4V LTC1290 • TC03 Voltage Waveform for DOUT Rise and Fall Times, tr, tf 2.4V DOUT 0.4V tr tf LTC1290 • TC04 Load Circuit for tdDO, tr and tf 1.4V 3k DOUT TEST POINT 100pF 1290 • TC05 Voltage Waveforms for ten and tdis 1 2 ACLK 2.0V CS DOUT WAVEFORM 1 (SEE NOTE 1) 2.4V ten DOUT WAVEFORM 2 (SEE NOTE 2) 90% tdis 0.8V 10% LTC1290 • TC06 NOTE 1: WAVEFORM 1 IS FOR AN OUTPUT WITH INTERNAL CONDITIONS SUCH THAT THE OUTPUT IS HIGH UNLESS DISABLED BY THE OUTPUT CONTROL. NOTE 2: WAVEFORM 2 IS FOR AN OUTPUT WITH INTERNAL CONDITIONS SUCH THAT THE OUTPUT IS LOW UNLESS DISABLED BY THE OUTPUT CONTROL. 1290fe 9 LTC1290 W U U UO APPLICATI S I FOR ATIO The LTC1290 is a data acquisition component which contains the following functional blocks: previous conversion is output on the DOUT line. At the end of the data exchange the requested conversion begins and CS should be brought high. After tCONV, the conversion is complete and the results will be available on the next data transfer cycle. As shown below, the result of a conversion is delayed by one CS cycle from the input word requesting it. 1. 12-bit successive approximation capacitive A/D converter 2. Analog multiplexer (MUX) 3. Sample-and-hold (S/H) 4. Synchronous, full duplex serial interface 5. Control and timing logic DIN DIN WORD 1 DOUT DOUT WORD 0 DIGITAL CONSIDERATIONS DATA TRANSFER Serial Interface DIN WORD 2 DIN WORD 3 DOUT WORD 1 tCONV A/D CONVERSION DOUT WORD 2 tCONV A/D CONVERSION DATA TRANSFER LTC1290 • AI01 The LTC1290 communicates with microprocessors and other external circuitry via a synchronous, full duplex, four-wire serial interface (see Operating Sequence). The shift clock (SCLK) synchronizes the data transfer with each bit being transmitted on the falling SCLK edge and captured on the rising SCLK edge in both transmitting and receiving systems. The data is transmitted and received simultaneously (full duplex). Input Data Word The LTC1290 8-bit data word is clocked into the DIN input on the first eight rising SCLK edges after chip select is recognized. Further inputs on the DIN pin are then ignored until the next CS cycle. The eight bits of the input word are defined as follows: UNIPOLAR/ BIPOLAR Data transfer is initiated by a falling chip select (CS) signal. After the falling CS is recognized, an 8-bit input word is shifted into the DIN input which configures the LTC1290 for the next conversion. Simultaneously, the result of the SGL/ DIFF ODD/ SIGN SELECT 1 SELECT 0 UNI WORD LENGTH MSBF WL1 MSB-FIRST/ LSB-FIRST MUX ADDRESS WL0 LTC1290 • AI02 Operating Sequence (Example: Differential Inputs (CH3-CH2), Bipolar, MSB-First and 12-Bit Word Length) tCYC 1 2 3 4 5 6 7 8 9 SCLK 10 11 12 DON’T CARE tSMPL tCONV CS DIN DON’T CARE B11 B10 B9 DOUT SHIFT CONFIGURATION WORD IN (SB) B8 B7 B6 B5 B4 B3 B2 B1 B0 SHIFT A/D RESULT OUT AND NEW CONFIGURATION WORD IN LTC1290 • AI03 1290fe 10 LTC1290 W U U UO APPLICATI S I FOR ATIO MUX Address The first four bits of the input word assign the MUX configuration for the requested conversion. For a given channel selection, the converter will measure the voltage between the two channels indicated by the + and – signs in the selected row of Table 1. Note that in differential mode (SGL/DIFF = 0) measurements are limited to four adjacent input pairs with either polarity. In single-ended mode, all input channels are measured with respect to COM. Table 1. Multiplexer Channel Selection MUX ADDRESS SGL/ ODD SELECT DIFF SIGN 1 0 0 0 0 0 0 0 0 1 0 0 1 0 0 0 1 1 0 1 0 0 0 1 0 1 0 1 1 0 0 1 1 1 DIFFERENTIAL CHANNEL SELECTION 0 1 + – 2 3 + – 5 4 + 0,1 { 2,3 { 4,5 { 6,7 { 7 – + – – + – + – + – 4 Differential CHANNEL 6 + 8 Single-Ended CHANNEL 0 1 2 3 4 5 6 7 + ( –) – ( +) + ( –) – ( +) + ( –) – ( +) + ( –) – ( +) SINGLE-ENDED CHANNEL SELECTION MUX ADDRESS SGL/ ODD SELECT DIFF SIGN 1 0 1 0 0 0 1 0 0 1 1 0 1 0 1 0 1 1 1 1 0 0 1 1 0 1 1 1 1 0 1 1 1 1 0 1 2 3 4 5 6 7 + + + + + + + + COM – – – – – – – – Combinations of Differential and Single-Ended CHANNEL + + + + + + + + 0,1 { + – 2,3 { – + + + + + 4 5 6 7 COM (–) COM (–) Changing the MUX Assignment “On the Fly” 4,5 { 6,7 { + – + – COM (UNUSED) 1ST CONVERSION 5,4 { – + 6 7 { + + COM (–) 2ND CONVERSION LTC1290 • F01 Figure 1. Examples of Multiplexer Options on the LTC1290 1290fe 11 LTC1290 W U U UO APPLICATI S I FOR ATIO Unipolar/Bipolar (UNI) The fifth input bit (UNI) determines whether the conversion will be unipolar or bipolar. When UNI is a logical one, a unipolar conversion will be performed on the selected input voltage. When UNI is a logical zero, a bipolar conversion will result. The input span and code assignment for each conversion type are shown in the figures below. Unipolar Transfer Curve (UNI = 1) Unipolar Output Code (UNI = 1) OUTPUT CODE INPUT VOLTAGE INPUT VOLTAGE (VREF = 5V) 111111111111 111111111110 • • • 000000000001 000000000000 VREF – 1LSB VREF – 2LSB • • • 1LSB 0V 4.9988V 4.9976V • • • 0.0012V 0V 111111111111 111111111110 • • • 000000000001 000000000000 LTC1290 • AI04a VIN VREF VREF – 1LSB VREF – 2LSB 1LSB 0V LTC1290 AI04b Bipolar Output Code (UNI = 0) OUTPUT CODE INPUT VOLTAGE INPUT VOLTAGE (VREF = 5V) OUTPUT CODE INPUT VOLTAGE INPUT VOLTAGE (VREF = 5V) 011111111111 011111111110 • • • 000000000001 000000000000 VREF – 1LSB VREF – 2LSB • • • 1LSB 0V 4.9976V 4.9851V • • • 0.0024V 0V 111111111111 111111111110 • • • 100000000001 100000000000 –1LSB –2LSB • • • –(VREF) + 1LSB – (VREF) –0.0024V –0.0048V • • • –4.9976V –5.0000V LTC1290 AI05a Bipolar Transfer Curve (UNI = 0) 011111111111 011111111110 1LSB –VREF + 1LSB –VREF • • • 000000000001 000000000000 VIN 100000000001 VREF –1LSB –2LSB • • • VREF – 1LSB 111111111110 VREF – 2LSB 111111111111 LTC1290 AI05b 100000000000 1290fe 12 LTC1290 U W U UO APPLICATI S I FOR ATIO MSB-First/LSB-First Format (MSBF) The output data of the LTC1290 is programmed for MSBfirst or LSB-first sequence using the MSBF bit. For MSB first output data the input word clocked to the LTC1290 should always contain a logical one in the sixth bit location (MSBF bit). Likewise for LSB-first output data the input word clocked to the LTC1290 should always contain a zero in the MSBF bit location. The MSBF bit affects only the order of the output data word. The order of the input word is unaffected by this bit. MSBF OUTPUT FORMAT 0 LSB First 1 MSB First Word Length (WL1, WL0) and Power Shutdown resumed once CS goes low or an SCLK is applied, if CS is already low. WL1 WL0 OUTPUT WORD LENGTH 0 0 8-Bits 0 1 Power Shutdown 1 0 12-Bits 1 1 16-Bits Deglitcher A deglitching circuit has been added to the Chip Select input of the LTC1290 to minimize the effects of errors caused by noise on that input. This circuit ignores changes in state on the CS input that are shorter in duration than one ACLK cycle. After a change of state on the CS input, the LTC1290 waits for two falling edge of the ACLK before recognizing a valid chip select. One indication of CS recognition is the DOUT line becoming active (leaving the Hi-Z state). Note that the deglitching applies to both the rising and falling CS edges. The last two bits of the input word (WL1 and WL0) program the output data word length and the power shutdown feature of the LTC1290. Word lengths of 8, 12 or 16 bits can be selected according to the following table. The WL1 and WL0 bits in a given DIN word control the length of the present, not the next, DOUT word. WL1 and WL0 are never “don’t cares” and must be set for the correct DOUT word length even when a “dummy” DIN word is sent. On any transfer cycle, the word length should be made equal to the number of SCLK cycles sent by the MPU. Power down will occur when WL1 = 0 and WL0 = 1 is selected. The previous conversion result will be clocked out as a 10 bit word so a “dummy” conversion is required before powering down the LTC1290. Conversions are In the normal mode of operation, CS is brought high during the conversion time. The serial port ignores any SCLK activity while CS is high. The LTC1290 will also operate with CS low during the conversion. In this mode, SCLK must remain low during the conversion as shown in the following figure. After the conversion is complete, the DOUT line will become active with the first output bit. Then the data transfer can begin as normal. Low CS Recognized Internally High CS Recognized Internally CS Low During Conversion ACLK ACLK CS CS DOUT HI-Z DOUT VALID OUTPUT LTC1290 • AI06 VALID OUTPUT HI-Z LTC1290 • AI07 1290fe 13 LTC1290 W U U UO APPLICATI S I FOR ATIO 8-Bit Word Length tSMPL tCONV CS SCLK 1 8 (SB) DOUT MSB-FIRST B11 B10 B9 B8 B7 B6 B5 B4 DOUT LSB-FIRST B0 B1 B2 B3 B4 B5 B6 B7 THE LAST FOUR BITS ARE TRUNCATED 12-Bit Word Length tSMPL tCONV CS 1 SCLK 10 12 (SB) DOUT MSB-FIRST B11 B10 B9 B8 B7 B6 B5 B4 B3 B2 B1 DOUT LSB-FIRST B0 B1 B2 B3 B4 B5 B6 B7 B8 B9 B10 B0 (SB) B11 16-Bit Word Length tSMPL tCONV CS SCLK 1 12 16 (SB) DOUT MSB-FIRST B11 B10 B9 B8 B7 B6 B5 B4 B3 B2 B1 DOUT LSB-FIRST B0 B1 B2 B3 B4 B5 B6 B7 B8 B9 B10 B0 FILL ZEROS (SB) B11 * * IN UNIPOLAR MODE, THESE BITS ARE FILLED WITH ZEROS. IN BIPOLAR MODE, THE SIGN BIT IS EXTENDED INTO THESE LOCATIONS. * * LTC1290 F02 Figure 2. Data Output (DOUT) Timing with Different Word Lengths 1290fe 14 LTC1290 W U U UO APPLICATI S I FOR ATIO SHIFT MUX ADDRESS IN tSMPL SAMPLE ANALOG INPUT 48 TO 52 ACLK CYC SHIFT RESULT OUT AND NEW ADDRESS IN CS SCLK DON’T CARE DIN DOUT B11 B10 B9 B8 B7 B6 B5 B4 B3 B2 B1 B0 B11 B10 B9 B8 B7 B6 B5 B4 B3 B2 B1 B0 LTC1290 F03 Figure 3. CS High During Conversion SHIFT MUX ADDRESS IN tSMPL SAMPLE ANALOG INPUT 48 TO 52 ACLK CYC SHIFT RESULT OUT AND NEW ADDRESS IN CS SCLK MUST REMAIN LOW SCLK DIN DOUT DON’T CARE B11 B10 B9 B8 B7 B6 B5 B4 B3 B2 B1 B0 B11 B10 B9 B8 B7 B6 B5 B4 B3 B2 B1 B0 LTC1290 F04 Figure 4. CS Low During Conversion (CS Must go High to Low Once to Insure Proper Operation in this Mode) Microprocessor Interfaces Serial Port Microprocessors The LTC1290 can interface directly (without external hardware) to most popular microprocessor (MPU) synchronous serial formats (see Table 2). If an MPU without a serial interface is used, then four of the MPU’s parallel port lines can be programmed to form the serial link to the LTC1290. Included here are two serial interface examples and one example showing a parallel port programmed to form the serial interface Most synchronous serial formats contain a shift clock (SCLK) and two data lines, one for transmitting and one for receiving. In most cases data bits are transmitted on the falling edge of the clock (SCLK) and captured on the rising edge. However, serial port formats vary among MPU manufactures as to the smallest number of bits that can be sent in one group (e.g., 4-bit, 8-bit or 16-bit transfers). They also vary as to the order in which the bits are transmitted (LSB or MSB first). The following examples show how the LTC1290 accommodates these differences. 1290fe 15 LTC1290 W U U UO APPLICATI S I FOR ATIO Table 2. Microprocessors with Hardware Serial Interfaces Compatible with the LTC1290** PART NUMBER TYPE OF INTERFACE Motorola MC6805S2, S3 MC68HC11 MC68HC05 SPI SPI SPI CDP68HC05 SPI RCA National MICROWIRE (COP402) The COP402 transfers data MSB first and in 4-bit increments (nibbles). This is easily accommodated by setting the LTC1290 to MSB-first format and 12-bit word length. The data output word is then received by the COP402 in three 4-bit blocks. COP402 Code Hitachi HD6305 HD6301 HD63701 HD6303 HD64180 SCI Synchronous SCI Synchronous SCI Synchronous SCI Synchronous SCI Synchronous National Semiconductor MICROWIRETM MICROWIRE/PLUSTM MICROWIRE/PLUS MICROWIRE/PLUS COP400 Family COP800 Family NS8050U HPC16000 Family Texas Instruments TMS7002 TMS7042 TMS70C02 TMS70C42 TMS32011* TMS32020 TMS370C050 Serial Port Serial Port Serial Port Serial Port Serial Port Serial Port SPI *Requires external hardware ** Contact factory for interface information for processors not on this list Hardware and Software Interface to COP402 Processor LTC1290 ANALOG INPUTS • • • • COP402 LOOP MNEMONIC COMMENTS CLRA LBI STII STII STII LEI SC LDD OGI XAS LDD NOP XAS XIS LDD XAS XIS RC CLRA XAS OGI XIS LBI Must be First Instruction BR = 1BD = 0 Initialize B Reg. First DIN Nibble in $10 Second DIN Nibble in $11 Null Data in $12, B = $13 Set EN to (1100) BIN Carry Set Load First DIN Nibble In ACC Go (CS) Cleared ACC to Shift Reg. Begin Shift Load Next DIN Nibble in ACC Timing Next Nibble, Shift Continues First Nibble DOUT to $13 Put Null Data in ACC Shift Continues, DOUT to ACC Next Nibble DOUT to $14 Clear Carry Clear ACC Third Nibble DOUT to ACC Go (CS) Set Third Nibble DOUT to $15 Set B Reg. For Next Loop 1,0 8 E 0 C 1,0 0 1,1 0 1,2 0 1 0 1,3 CS GO Motorola SPI (MC68HC05C4) SCLK SK DIN SO DOUT SI The MC68HC05C4 transfers data MSB first and in 8-bit increments. Programming the LTC1290 for MSB-first format and 16-bit word length allows the 12-bit data output to be received by the MPU as two 8-bit bytes with the final four unused bits filled with zeros by the LTC1290. LTC1290 • AI08 DOUT from LTC1290 Stored in COP402 RAM MSB† LOCATION $13 B11 B10 B9 B8 FIRST 4 BITS LOCATION $14 B7 B6 B5 B4 SECOND 4 BITS LSB LOCATION $15 B3 B2 B1 B0 THIRD 4 BITS †B11 IS MSB IN UNIPOLAR OR SIGN BIT IN BIPOLAR MICROWIRE and MICROWIRE PLUS are trademarks of National Semiconductor Corp 1290fe 16 LTC1290 W U U UO APPLICATI S I FOR ATIO Hardware and Software Interface to Motorola MC68HC05C4 Processor CO CS • • • • When interfacing the LTC1290 to an MPU which has a parallel port, the serial signals are created on the port with software. Three MPU port lines are programmed to create the CS, SCLK and DIN signals for the LTC1290. A fourth port line reads the DOUT line. An example is made of the Intel 8051/8052/80C252 family. MC68HC05C4 LTC1290 ANALOG INPUTS Parallel Port Microprocessors SCLK SCK DIN MOSI DOUT MISO LTC1290 • AI09 Intel 8051 DOUT from LTC1290 Stored in MC68HC05C4 RAM MSB* LOCATION $61 B11 B10 B9 B8 B7 B6 B5 B4 BYTE 1 0 0 0 0 BYTE 2 To interface to the 8051, the LTC1290 is programmed for MSB-first format and 12-bit word length. The 8051 generates CS, SCLK and DIN on three port lines and reads DOUT on the fourth. LSB LOCATION $62 B3 B2 B1 B0 Hardware and Software Interface to Intel 8051 Processor LTC1290 *B11 IS MSB IN UNIPOLAR OR SIGN BIT IN BIPOLAR MC68HC05C4 Code MNEMONIC START LDA STA LDA STA LDA STA BCLR LDA STA #$50 $0A #$FF $06 #$0F $50 0,$20 $50 $0C NOP LDA LDA STA STA 8 NOPs for Timing $0B $0C $61 $0C NOP BSET LDA LDA STA COMMENTS Configuration Data for SPCR Load Data Into SPCR ($0A) Config. Data for Port C DDR Load Data Into Port C DDR Load LTC1290 DIN Data Into ACC Load LTC1290 DIN Data Into $50 CO Goes Low (CS Goes Low) Load DIN Into ACC from $50 Load DIN Into SPI, Start SCK Check SPI Status Reg Load LTC1290 MSBs Into ACC Store MSBs in $61 Start Next SPI Cycle • • • • • • • • ANALOG INPUTS 8051 DOUT P1.1 DIN P1.2 SCLK P1.3 CS P1.4 ACLK ALE LTC1290 • AI10 DOUT from LTC1290 Stored in 8051 RAM MSB* R2 B11 B10 B9 B8 B7 B6 B5 54 0 0 0 0 LSB R3 B3 B2 B1 B0 *B11 IS MSB IN UNIPOLAR OR SIGN BIT IN BIPOLAR 6 NOPs for Timing 0,$02 $0B $0C $62 CO Goes High (CS Goes High) Check SPI Status Register Load LTC1290 LSBs Into ACC Store LSBs in $62 1290fe 17 LTC1290 W U U UO APPLICATI S I FOR ATIO 8051 Code Sharing the Serial Interface MNEMONIC CONT LOOP DELAY MOV CLR SETB MOV CLR MOV NOP MOV RLC MOV SETB CLR DJNZ MOV MOV CLR RLC SETB CLR MOV RLC SETB CLR MOV RLC SETB CLR MOV RRC RRC RRC RRC MOV SETB CLR SETB P1,#02H P1.3 P1.4 A,#0EH P1.4 R4,#08H C,P1.1 A P1.2,C P1.3 P1.3 R4,LOOP R2,A C,P1.1 A A P1.3 P1.3 C,P1.1 A P1.3 P1.3 C,P1.1 A P1.3 P1.3 C, P1.1 A A A A R3,A P1.3 P1.3 P1.4 MOV R5,#0BH DJNZ R5,DELAY COMMENTS The LTC1290 can share the same 3-wire serial interface with other peripheral components or other LTC1290s (see Figure 5). In this case, the CS signals decide which LTC1290 is being addressed by the MPU. Bit 1 Port 1 Set as Input SCLK Goes Low CS Goes High DIN Word for LTC1290 CS Goes Low Load Counter Delay for Deglitcher Read Data Bit Into Carry Rotate Data Bit Into ACC Output DIN Bit to LTC1290 SCLK Goes High SCLK Goes Low Next Bit Store MSBs in R2 Read Data Bit Into Carry Clear ACC Rotate Data Bit Into ACC SCLK Goes High SCLK Goes Low Read Data Bit Into Carry Rotate Data Bit Into ACC SCLK Goes High SCLK Goes Low Read Data Bit Into Carry Rotate Data Bit Into ACC SCLK Goes High SCLK Goes Low Read Data Bit Into Carry Rotate Right Into ACC Rotate Right Into ACC Rotate Right Into ACC Rotate Right Into ACC Store LSBs in R3 SCLK Goes High SCLK Goes Low CS Goes High ANALOG CONSIDERATIONS 1. Grounding The LTC1290 should be used with an analog ground plane and single point grounding techniques. AGND (Pin 11) should be tied directly to this ground plane. DGND (Pin 10) can also be tied directly to this ground plane because minimal digital noise is generated within the chip itself. VCC (Pin 20) should be bypassed to the ground plane with a 22µF tantalum with leads as short as possible. V – (Pin 12) should be bypassed with a 0.1µF ceramic disk. For single supply applications, V – can be tied to the ground plane. It is also recommended that REF – (Pin 13) and COM (Pin 9) be tied directly to the ground plane. All analog inputs should be referenced directly to the single point ground. Digital inputs and outputs should be shielded from and/or routed away from the reference and analog circuitry. Load Counter Go to Delay if Not Done 2 1 0 OUTPUT PORT SERIAL DATA MPU 3-WIRE SERIAL INTERFACE TO OTHER PERIPHERALS OR LTC1290s 3 3 3 3 CS LTC1290 CS LTC1290 CS LTC1290 8 CHANNELS 8 CHANNELS 8 CHANNELS LTC1290 F05 Figure 5. Several LTC1290s Sharing One 3-Wire Serial Interface 1290fe 18 LTC1290 W U U UO APPLICATI S I FOR ATIO VCC 1 VERTICAL: 0.5mV/DIV 22µF TANTALUM 20 HORIZONTAL: 10µs/DIV Figure 7. Poor VCC Bypassing. Noise and Ripple Can Cause A/D Errors V– 10 ANALOG GROUND PLANE 0.1µF CERAMIC DISK CS Figure 6. Example Ground Plane for the LTC1290 Figure 6 shows an example of an ideal ground plane design for a two-sided board. Of course, this much ground plane will not always be possible, but users should strive to get as close to this ideal as possible. VERTICAL: 0.5mV/DIV LTC1290 F06 VCC HORIZONTAL: 10µs/DIV 2. Bypassing For good performance, VCC must be free of noise and ripple. Any changes in the VCC voltage with respect to analog ground during a conversion cycle can induce errors or noise in the output code. VCC noise and ripple can be kept below 0.5mV by bypassing the VCC pin directly to the analog ground plane with a 22µF tantalum capacitor and leads as short as possible. The lead from the device to the VCC supply should also be kept to a minimum and the VCC supply should have a low output impedance such as that obtained from a voltage regulator (e.g., LT1761). Figures 7 and 8 show the effects of good and poor VCC bypassing. 3. Analog Inputs Because of the capacitive redistribution A/D conversion techniques used, the analog inputs of the LTC1290 have capacitive switching input current spikes. These current Figure 8. Good VCC Bypassing Keeps Noise and Ripple on VCC Below 1mV spikes settle quickly and do not cause a problem. However, if large source resistances are used or if slow settling op amps drive the inputs, care must be taken to insure that the transients caused by the current spikes settle completely before the conversion begins. Source Resistance The analog inputs of the LTC1290 look like a 100pF capacitor (CIN) in series with a 500Ω resistor (RON) as shown in Figure 9. CIN gets switched between the selected “+” and “–” inputs once during each conversion cycle. Large external source resistors and capacitances will slow the settling of the inputs. It is important that the overall RC time constants be short enough to allow the analog inputs to completely settle within the allowed time. 1290fe 19 LTC1290 W U U UO APPLICATI S I FOR ATIO “–” Input Settling “+” INPUT RSOURCE + LTC1290 VIN + RSOURCE – C1 4TH SCLK RON = 500Ω “–” INPUT LAST SCLK CIN = 100pF VIN – C2 LTC1290 F09 Figure 9. Analog Input Equivalent Circuit “+” Input Settling This input capacitor is switched onto the “+” input during the sample phase (tSMPL, see Figure 10). The sample phase starts at the 4th SCLK cycle and lasts until the falling edge of the last SCLK (the 8th, 12th or 16th SCLK cycle depending on the selected word length). The voltage on the “+” input must settle completely within this sample time. Minimizing RSOURCE+ and C1 will improve the input settling time. If large “+” input source resistance must be used, the sample time can be increased by using a slower SCLK frequency or selecting a longer word length. With the minimum possible sample time of 2µs, RSOURCE+ < 1k and C1 < 20pF will provide adequate settling. SAMPLE MUX ADDRESS SHIFTED IN ACLK Input Op Amps When driving the analog inputs with an op amp it is important that the op amp settle within the allowed time (see Figure 10). Again, the “+” and “–” input sampling times can be extended as described above to accommodate slower op amps. Most op amps including the LT1797, LT1800 and LT1812 single supply op amps can be made to settle well even with the minimum settling windows of 2µs (“+” input) and 1µs (“–” input) which occur at the HOLD ••• CS SCLK “+” INPUT MUST SETTLE DURING THIS TIME tSMPL At the end of the sample phase the input capacitor switches to the “–” input and the conversion starts (see Figure 10). During the conversion, the “+” input voltage is effectively “held” by the sample-and-hold and will not affect the conversion result. However, it is critical that the “–” input voltage be free of noise and settle completely during the first four ACLK cycles of the conversion time. Minimizing RSOURCE– and C2 will improve settling time. If large “–” input source resistance must be used, the time allowed for settling can be extended by using a slower ACLK frequency. At the maximum ACLK rate of 4MHz, RSOURCE– < 250Ω and C2 < 20pF will provide adequate settling. 1 2 3 4 LAST SCLK (8TH, 12TH OR 16TH DEPENDING ON WORD LENGTH) ••• ••• 1 2 3 4 ••• 1ST BIT TEST “–” INPUT MUST SETTLE DURING THIS TIME “+” INPUT “–” INPUT 1290 • F10 Figure 10. “+” and “–” Input Settling Windows 1290fe 20 LTC1290 U W U UO APPLICATI S I FOR ATIO maximum clock rates (ACLK = 4MHz and SCLK = 2MHz). Figures 11 and 12 show examples of adequate and poor op amp settling. RFILTER IDC VIN "+" CFILTER LTC1290 "–" LTC1290 F13 VERTICAL: 5mV/DIV Figure 13. RC Input Filtering Input Leakage Current HORIZONTAL: 500ns/DIV Figure 11. Adequate Settling of Op Amps Driving Analog Input Input leakage currents can also create errors if the source resistance gets too large. For instance, the maximum input leakage specification of 1µA (at 125°C) flowing through a source resistance of 1kΩ will cause a voltage drop of 1mV or 0.8LSB. This error will be much reduced at lower temperatures because leakage drops rapidly (see the typical curve of Input Channel Leakage Current vs Temperature). VERTICAL: 5mV/DIV Noise Coupling Into Inputs HORIZONTAL: 20µs/DIV Figure 12. Poor Op Amp Settling Can Cause A/D Errors RC Input Filtering It is possible to filter the inputs with an RC network as shown in Figure 13. For large values of CF (e.g., 1µF), the capacitive input switching currents are averaged into a net DC current. Therefore, a filter should be chosen with a small resistor and large capacitor to prevent DC drops across the resistor. The magnitude of the DC current is approximately IDC = (100pF)(VIN/tCYC) and is roughly proportional to VIN. When running at the minimum cycle time of 20µs, the input current equals 25µA at VIN = 5V. In this case, a filter resistor of 5Ω will cause 0.1LSB of full-scale error. If a larger filter resistor must be used, errors can be eliminated by increasing the cycle time as shown in the typical curve of Maximum Filter Resistor vs Cycle Time. High source resistance input signals (>500Ω) are more sensitive to coupling from external sources. It is preferable to use channels near the center of the package (i.e., CH2 to CH7) for signals which have the highest output resistance because they are essentially shielded by the pins on the package ends (DGND and CH0). Grounding any unused inputs (especially the end pin, CH0) will also reduce outside coupling into high source resistances. 4. Sample-and-Hold Single-Ended Inputs The LTC1290 provides a built-in sample-and-hold (S&H) function for all signals acquired in the single-ended mode (COM pin grounded). This sample-and-hold allows the LTC1290 to convert rapidly varying signals (see the typical curve of S&H Acquisition Time vs Source Resistance). The input voltage is sampled during the tSMPL time as shown in Figure 10. The sampling interval begins after the fourth MUX address bit is shifted in and continues during the remainder of the data transfer. On the falling edge of the final SCLK, the S&H goes into hold mode and the conversion begins. The voltage will be held on either the 8th, 12th or 16th falling edge of the SCLK depending on the word length selected. 1290fe 21 LTC1290 W U U UO S I FOR ATIO With differential inputs or when the COM pin is not tied to ground, the A/D no longer converts just a single voltage but rather the difference between two voltages. In these cases, the voltage on the selected “+” input is still sampled and held and therefore may be rapidly time varying just as in singleended mode. However, the voltage on the selected “–” input must remain constant and be free of noise and ripple throughout the conversion time. Otherwise, the differencing operation may not be performed accurately. The conversion time is 52 ACLK cycles. Therefore, a change in the “–” input voltage during this interval can cause conversion errors. For a sinusoidal voltage on the “–” input this error would be: VERROR (MAX) = (VPEAK)(2π)[ f(“–”)](52/fACLK) Where f(“–”) is the frequency of the “–” input voltage, VPEAK is its peak amplitude and fACLK is the frequency of the ACLK. In most cases VERROR will not be significant. For a 60Hz signal on the “–” input to generate a 0.25LSB error (300µV) with the converter running at ACLK = 4MHz, its peak value would have to be 61mV. 5. Reference Inputs The voltage between the reference inputs of the LTC1290 defines the voltage span of the A/D converter. The reference inputs will have transient capacitive switching currents due to the switched capacitor conversion technique (see Figure 14). During each bit test of the conversion (every 4 ACLK cycles), a capacitive current spike will be generated on the reference pins by the A/D. These current spikes settle quickly and do not cause a problem. However, if slow settling circuitry is used to drive the reference inputs, care must be taken to insure that transients caused by these current spikes settle completely during each bit test of the conversion. REF+ 14 ROUT VREF REF– 13 LTC1290 EVERY 4 ACLK CYCLES RON When driving the reference inputs, two things should be kept in mind: 1. Transients on the reference inputs caused by the capacitive switching currents must settle completely during each bit test (each 4 ACLK cycles). Figures 15 and 16 show examples of both adequate and poor settling. Using a slower ACLK will allow more time for the reference to settle. However, even at the maximum ACLK rate of 4MHz most references and op amps can be made to settle within the 1µs bit time. For example the LT1236 will settle adequately. 2. It is recommended that REF – input be tied directly to the analog ground plane. If REF – is biased at a voltage other than ground, the voltage must not change during a conversion cycle. This voltage must also be free of noise and ripple with respect to analog ground. VERTICAL: 0.5mV/DIV Differential Inputs HORIZONTAL: 1µs/DIV Figure 15. Adequate Reference Settling VERTICAL: 0.5mV/DIV APPLICATI 8pF TO 40pF LTC 1290 F14 Figure 14. Reference Input Equivalent Circuit HORIZONTAL: 1µs/DIV Figure 16. Poor Reference Settling Can Cause A/D Errors 1290fe 22 LTC1290 U W U UO APPLICATI S I FOR ATIO 6. Reduced Reference Operation The effective resolution of the LTC1290 can be increased by reducing the input span of the converter. The LTC1290 exhibits good linearity and gain over a wide range of reference voltages (see the typical curves of Linearity and Gain Error vs Reference Voltage). However, care must be taken when operating at low values of VREF because of the reduced LSB step size and the resulting higher accuracy requirement placed on the converter. The following factors must be considered when operating at low VREF values: 1. Offset 2. Noise Offset with Reduced VREF The offset of the LTC1290 has a larger effect on the output code when the A/D is operated with reduced reference voltage. The offset (which is typically a fixed voltage) becomes a larger fraction of an LSB as the size of the LSB is reduced. The typical curve of Unadjusted Offset Error vs Reference Voltage shows how offset in LSBs is related to reference voltage for a typical value of VOS. For example, a VOS of 0.1mV which is 0.1LSB with a 5V reference becomes 0.4LSB with a 1.25V reference. If this offset is unacceptable, it can be corrected digitally by the receiving system or by offsetting the “–” input to the LTC1290. Noise with Reduced VREF The total input referred noise of the LTC1290 can be reduced to approximately 200µV peak-to-peak using a ground plane, good bypassing, good layout techniques and minimizing noise on the reference inputs. This noise is insignificant with a 5V reference but will become a larger fraction of an LSB as the size of the LSB is reduced. The typical curve of Noise Error vs Reference Voltage shows the LSB contribution of this 200µV of noise. For operation with a 5V reference, the 200µV noise is only 0.16LSB peak-to-peak. In this case, the LTC1290 noise will contribute virtually no uncertainty to the output code. However, for reduced references, the noise may become a significant fraction of an LSB and cause undesirable jitter in the output code. For example, with a 1.25V reference, this same 200µV noise is 0.64LSB peak-to-peak. This will reduce the range of input voltages over which a stable output code can be achieved by 0.64LSB. In this case averaging readings may be necessary. This noise data was taken in a very clean setup. Any setup induced noise (noise or ripple on VCC, VREF, VIN or V –) will add to the internal noise. The lower the reference voltage to be used, the more critical it becomes to have a clean, noise-free setup. 7. LTC1290 AC Characteristics Two commonly used figures of merit for specifying the dynamic performance of the A/D’s in digital signal processing applications are the Signal-to-Noise Ratio (SNR) and the “effective number of bits (ENOB).” SNR is defined as the ratio of the RMS magnitude of the fundamental to the RMS magnitude of all the nonfundamental signals up to the Nyquist frequency (half the sampling frequency). The theoretical maximum SNR for a sine wave input is given by: SNR = (6.02N + 1.76dB) where N is the number of bits. Thus the SNR is a function of the resolution of the A/D. For an ideal 12-bit A/D the SNR is equal to 74dB. A Fast Fourier Transform(FFT) plot of the output spectrum of the LTC1290 is shown in Figures 17a and 17b. The input (fIN) frequencies are 1kHz and 25kHz with the sampling frequency (fS) at 50.6kHz. The SNR obtained from the plot are 73.25dB and 72.54dB. Rewriting the SNR expression it is possible to obtain the equivalent resolution based on the SNR measurement. N = (SNR – 1.76dB)/6.02 This is the so-called effective number of bits (ENOB). For the example shown in Figures 17a and 17b, N = 11.9 bits and 11.8 bits, respectively. Figure 18 shows a plot of ENOB as a function of input frequency. The curve shows the A/D’s ENOB remain in the range of 11.9 to 11.8 for input frequencies up to fS/2. Figure 19 shows an FFT plot of the output spectrum for two tones applied to the input of the A/D. Nonlinearities in the A/D will cause distortion products at the sum and difference frequencies of the fundamentals and products of the fundamentals. This is classically referred to as intermodulation distortion (IMD). 1290fe 23 LTC1290 U UO S I FOR ATIO fIN = 1kHz fSAMPLE = 50.6kHz SNR = 73.25dB 0 –20 MAGNITUDE (dB) W U APPLICATI –20 MAGNITUDE (dB) –40 –60 –80 –40 –60 –80 –100 –100 –120 –120 –140 0 4 8 12 16 20 FREQUENCY (kHz) fIN = 25kHz fSAMPLE = 50.6kHz SNR = 72.54dB 0 –140 24 0 4 8 12 16 20 FREQUENCY (kHz) 1290 • F17a 1290 • F17b Figure 17a. LTC1290 FFT Plot fIN1 = 5.1kHz fIN2 = 5.6kHz fSAMPLE = 50.6kHz 0 11.6 –20 11.2 MAGNITUDE (dB) EFFECTIVE NUMBER OF BITS Figure 17b. LTC1290 FFT Plot fSAMPLE = 50.6kHz 12 24 10.8 10.4 10 9.6 –40 –60 –80 –100 9.2 –120 8.8 0 20 60 40 FREQUENCY (kHz) 80 100 1290 F18 Figure 18. LTC1290 ENOB vs Input Frequency 8. Overvoltage Protection Applying signals to the analog MUX that exceed the positive or negative supply of the device will degrade the accuracy of the A/D and possibly damage the device. For example this condition would occur if a signal is applied to the analog MUX before power is applied to the LTC1290. Another example is the input source is operating from different supplies of larger value than the LTC1290. These conditions should be prevented either with proper supply sequencing or by use of external circuitry to clamp or current limit the input source. As shown in Figure 20, a 1k resistor is enough to stand off ±15V (15mA for one only channel). If more than one channel exceeds the supplies 0 4 8 12 16 20 FREQUENCY (kHz) 24 1290 • F19 Figure 19. LTC1290 FFT Plot then the following guidelines can be used. Limit the current to 7mA per channel and 28mA for all channels. This means four channels can handle 7mA of input current each. Reducing the ACLK and SCLK frequencies from the maximum of 4MHz and 2MHz, respectively, (see Typical Performance Characteristics curves Maximum ACLK Frequency vs Source Resistance and Sample-and-Hold Acquisition Time vs Source Resistance) allows the use of larger current limiting resistors. Use 1N4148 diode clamps from the MUX inputs to VCC and V – if the value of the series resistor will not allow the maximum clock speeds to be used or if an unknown source is used to drive the LTC1290 MUX inputs. 1290fe 24 LTC1290 W U UO VIN U APPLICATI S I FOR ATIO 1k 5V VCC CH0 22µF LTC1290 DGND V– –5V AGND 0.1µF 1290 F20 Figure 20. Overvoltage Protection for MUX How the various power supplies to the LTC1290 are applied can also lead to overvoltage conditions. For single supply operation (i.e., unipolar mode), if VCC and REF + are not tied together, then VCC should be turned on first, then REF +. If this sequence cannot be met, connecting a diode from REF + to VCC is recommended (see Figure 21). VCC 20 For dual supplies (bipolar mode) placing two Schottky diodes from VCC and V – to ground (Figure 23) will prevent power supply reversal from occurring when an input source is applied to the analog MUX before power is applied to the device. Power supply reversal occurs, for example, if the input is pulled below V – then VCC will pull a diode drop below ground which could cause the device not to power up properly. Likewise, if the input is pulled above VCC then V – will be pulled a diode drop above ground. If no inputs are present on the MUX, the Schottky diodes are not required if V – is applied first, then VCC. Because a unique input protection structure is used on the digital input pins, the signal levels on these pins can exceed the device VCC without damaging the device. LTC1290 5V VCC 5V 22µF 1N5817 22µF 1N5817 0.1µF LTC1290 1N4148 V– 14 REF+ VREF DGND AGND –5V 1290 F21 1290 F22 Figure 21 Figure 22. Power Supply Reversal 1290fe 25 LTC1290 UO TYPICAL APPLICATI S A “Quick Look” Circuit for the LTC1290 A “Quick Look” Circuit for the LTC1290 Users can get a quick look at the function and timing of the LTC1290 by using the following simple circuit. REF + and DIN are tied to VCC selecting a 5V input span, CH7 as a single-ended input, unipolar mode, MSB-first format and 16-bit word length. ACLK and SCLK are tied together and driven by an external clock. CS is driven at 1/128 the clock rate by the CD4520 and DOUT outputs the data. All other pins are tied to a ground plane. The output data from the DOUT pin can be viewed on an oscilloscope which is set up to trigger on the falling edge of CS. 5V 22µF VIN LTC1290 f/128 CHO VCC CH1 ACLK CH2 SCLK CLK f VDD EN RESET Q4 CH3 DIN Q1 CH4 DOUT Q2 CH5 CS Q3 Q2 CH6 REF + Q4 Q1 CH7 REF – RESET COM V– DGND CD4520 VSS 0.1µF Q3 EN CLK AGND 1290 TA02 { CLOCK IN 2MHz MAX TO OSCILLOSCOPE Scope Trace of LTC1290 “Quick Look” Circuit Showing A/D Output of 010101010101 (555HEX) CS ACLK/ SCLK DOUT DEGLITCHER TIME MSB (B11) LSB (B0) FILLS ZEROS VERTICAL: 5V/DIV HORIZONTAL: 1µs/DIV 1290fe 26 LTC1290 UO TYPICAL APPLICATI S SNEAK-A-BITTM The LTC1290’s unique ability to software select the polarity of the differential inputs and the output word length is used to achieve one more bit of resolution. Using the circuit below with two conversions and some software, a 2’s complement 12-bit + sign word is returned to memory inside the MPU. The MC68HC05C4 was chosen as an example, however, any processor could be used. Two 12-bit unipolar conversions are performed: the first over a 0V to 5V span and the second over a 0V to –5V span (by reversing the polarity of the inputs). The sign of the input is determined by which of the two spans contained it. Then the resulting number (ranging from –4095 to +4095 decimal) is converted to 2’s complement notation and stored in RAM. SNEAK-A-BIT Circuit SNEAK-A-BIT VIN 22µF 5V LT1021-5 9V VIN (+) CH6 1ST CONVERSION 4096 STEPS (–) CH7 2MHz CLOCK OTHER CHANNELS OR SNEAK-A-BIT INPUTS CHO VCC CH1 ACLK CH2 SCLK CH3 DIN MOSI CH4 DOUT MISO CH5 VIN –5V TO 5V 1ST CONVERSION MC68HC05C4 SCLK LTC1290 REF + CH7 REF – COM V– DGND 0V SOFTWARE 0V (–) CH6 0V 8191 STEPS 2ND CONVERSION 4096 STEPS (+) CH7 –5V –5V 2ND CONVERSION 1290 TA05 CO CS CH6 VIN 5V 1290 TA04 AGND 0.1µF –5V SNEAK-A-BIT is a trademark of Linear Technology Corp. 1290fe 27 LTC1290 UO TYPICAL APPLICATI S SNEAK-A-BIT Code SNEAK-A-BIT Code for the LTC1290 Using the MC68HC05C4 DOUT from LTC1290 in MC68HC05C4 RAM MNEMONIC Sign READ –/+: LOCATION $77 B12 B11 B10 B9 LOCATION $87 B4 B3 B2 B1 B8 B7 B6 B5 LSB B0 Filled with 0s DIN Words for LTC1290 MSBF MUX Addr. UNI Word Length (ODD/SIGN) DIN1 0 0 1 1 1 1 1 1 DIN2 0 1 1 1 1 1 1 1 DIN3 0 0 1 1 1 1 1 1 1290 TA06 SNEAK-A-BIT Code for the LTC1290 Using the MC68HC05C4 MNEMONIC LDA STA LDA STA BSET JSR #$50 $0A #$FF $06 0,$02 READ –/+ JSR JSR JSR READ –/+ READ –/+ CHK Sign DESCRIPTION Configuration Data for SPCR Load Configuration Data into $0A Configuration Data for Port C DDR Load Configuration Data into Port C DDR Make Sure CS is High Dummy Read Configures LTC1290 for next read Read CH6 with Respect to CH7 Read CH7 with Respect to CH6 Determines which Reading has Valid Data, Converts to 2’s Complement and Stores in RAM LDA JSR LDA STA LDA STA RTS READ +/–: LDA JSR LDA STA LDA STA RTS TRANSFER: BCLR STA LOOP 1: TST BPL LDA STA STA LOOP 2: TST BPL BSET LDA STA RTS CHK SIGN: LDA ORA BEQ CLC ROR ROR LDA STA LDA STA BRA MINUS: CLC ROR ROR COM COM LDA ADD STA CLRA ADC STA STA LDA STA END: RTS #$3F TRANSFER $60 $71 $61 $72 #$7F TRANSFER $60 $73 $61 $74 0,$02 $0C $0B LOOP 1 $0C $0C $60 $0B LOOP 2 0,$02 $0C $61 $73 $74 MINUS $73 $74 $73 $77 $74 $87 END $71 $72 $71 $72 $72 #$01 $72 $71 $71 $77 $72 $87 DESCRIPTION Load DIN Word for LTC1290 into ACC Read LTC1290 Routine Load MSBs from LTC1290 into ACC Store MSBs in $71 Load LSBs from LTC1290 into ACC Store LSBs in $72 Return Load DIN Word for LTC1290 into ACC Read LTC1290 Routine Load MSBs from LTC1290 into ACC Store MSBs in $73 Load LSBs from LTC1290 into ACC Store LSBs in $74 Return CS Goes Low Load DIN into SPI, Start Transfer Test Status of SPIF Loop to Previous Instruction if Not Done Load Contents of SPI Data Reg. into ACC Start Next Cycle Store MSBs in $60 Test Status of SPIF Loop to Previous Instruction if Not Done CS Goes High Load Contents of SPI Data Reg. into ACC Store LSBs in $61 Return Load MSBs of ± Read into ACC Or ACC (MSBs) with LSBs of ± Read If Result is 0 Go to Minus Clear Carry Rotate Right $73 Through Carry Rotate Right $74 Through Carry Load MSBs of ± Read into ACC Store MSBs in RAM Location $77 Load LSBs of ± Read into ACC Store LSBs in RAM Location $87 Go to End of Routine Clear Carry Shift MSBs of ± Read Right Shift LSBs of ± Read Right 1’s Complement of MSBs 1’s Complement of LSBs Load LSBs into ACC Add 1 to LSBs Store ACC in $72 Clear ACC Add with Carry to MSBs. Result in ACC Store ACC in $71 Store MSBs in RAM Location $77 Load LSBs in ACC Store LSBs in RAM Location $87 Return 1290fe 28 LTC1290 UO TYPICAL APPLICATI S Power Shutdown For battery-powered applications it is desirable to keep power dissipation at a minimum. The LTC1290 can be powered down when not in use reducing the supply current from a nominal value of 5mA to typically 5µA (with ACLK turned off). See the curve for Supply Current (Power Shutdown) vs ACLK if ACLK cannot be turned off when the LTC1290 is powered down. In this case the supply current is proportional to the ACLK frequency and is independent of temperature until it reaches the magnitude of the supply current attained with ACLK turned off. As an example of how to use this feature let’s add this to the previous application, SNEAK-A-BIT. After the CHK SIGN subroutine call insert the following: • • JSR CHK SIGN Determines which reading has valid data, converts to 2’s complement and stores in RAM JSR SHUTDOWN LTC1290 power shutdown routine The actual subroutine is: SHUTDOWN: LDA #$3D Load DIN word for LTC1290 into ACC JSR TRANSFER Read LTC1290 routine RTS Return To place the device in power shutdown the word length bits are set to WL1 = 0 and WL0 = 1. The LTC1290 is powered up on the next request for a conversion and it’s ready to digitize an input signal immediately. Power Shutdown Timing Considerations After power shutdown has been requested, the LTC1290 is powered up on the next request for a conversion. This request can be initiated either by bringing CS low or by starting the next cycle of SCLKs if CS is kept low (see Figures 3 and 4). When the SCLK frequency is much slower than the ACLK frequency a situation can arise where the LTC1290 could power down and then prematurely power back up. Power shutdown begins at the negative going edge of the 10th SCLK once it has been requested. A dummy conversion is executed and the LTC1290 waits for the next request for conversion. If the SCLKs have not finished once the LTC1290 has finished its dummy conversion, it will recognize the next remaining SCLKs as a request to start a conversion and power up the LTC1290 (see Figure 23). To prevent this, bring either CS high at the 10th SCLK (Figure 24) or clock out only 10 SCLKs (Figure 25) when power shutdown is requested. CS 1 10 SCLK POWER SHUTDOWN STARTS DUMMY CONVERSION FINISHES AFTER 52 ACLK PERIODS POWER UP 1290 TAF23 Figure 23. Power Shutdown Timing Problem CS 1 10 POWER UP SCLK POWER SHUTDOWN STARTS DUMMY CONVERSION FINISHES AFTER 52 ACLK PERIODS 1290 TAF24 Figure 24. Power Shutdown Timing CS 1 10 POWER UP SCLK POWER SHUTDOWN STARTS DUMMY CONVERSION FINISHES AFTER 52 ACLK PERIODS 1290 TAF25 Figure 25. Power Shutdown Timing 1290fe 29 LTC1290 U PACKAGE DESCRIPTIO J Package 20-Lead CERDIP (Narrow 0.300, Hermetic) (LTC DWG # 05-08-1110) 0.300 BSC (0.762 BSC) CORNER LEADS OPTION (4 PLCS) 0.008 – 0.018 (0.203 – 0.457) 0° – 15° 0.200 (5.080) MAX 0.015 – 0.060 (0.381 – 1.524) 0.023 – 0.045 (0.584 – 1.143) HALF LEAD OPTION 0.045 – 0.068 (1.143 – 1.727) FULL LEAD OPTION NOTE: LEAD DIMENSIONS APPLY TO SOLDER DIP/PLATE OR TIN PLATE LEADS 1.060 (26.924) MAX 20 19 18 17 16 15 14 13 12 11 2 3 4 5 6 7 8 9 10 0.220 – 0.310 0.025 (5.588 – 7.874) (0.635) RAD TYP 1 0.005 (0.127) MIN 0.125 (3.175) MIN 0.045 – 0.065 (1.143 – 1.651) 0.100 (2.54) BSC 0.014 – 0.026 (0.356 – 0.660) J20 1298 OBSOLETE PACKAGE N Package 20-Lead PDIP (Narrow .300 Inch) (Reference LTC DWG # 05-08-1510) 1.060* (26.924) MAX 20 19 18 17 16 15 14 13 12 11 1 2 3 4 5 6 7 8 9 10 .255 ± .015* (6.477 ± 0.381) .300 – .325 (7.620 – 8.255) .008 – .015 (0.203 – 0.381) ( +.035 .325 –.015 +0.889 8.255 –0.381 NOTE: 1. DIMENSIONS ARE ) .045 – .065 (1.143 – 1.651) .125 – .145 (3.175 – 3.683) .020 (0.508) MIN .065 (1.651) TYP .120 (3.048) MIN .005 (0.127) MIN INCHES MILLIMETERS *THESE DIMENSIONS DO NOT INCLUDE MOLD FLASH OR PROTRUSIONS. MOLD FLASH OR PROTRUSIONS SHALL NOT EXCEED .010 INCH (0.254mm) .100 (2.54) BSC .018 ± .003 (0.457 ± 0.076) N20 0405 1290fe 30 LTC1290 U PACKAGE DESCRIPTIO SW Package 20-Lead Plastic Small Outline (Wide .300 Inch) (Reference LTC DWG # 05-08-1620) .050 BSC .045 ±.005 .030 ±.005 TYP .496 – .512 (12.598 – 13.005) NOTE 4 N 20 18 17 16 15 14 13 12 11 N .325 ±.005 .420 MIN 19 .394 – .419 (10.007 – 10.643) NOTE 3 1 2 3 N/2 N/2 RECOMMENDED SOLDER PAD LAYOUT .005 (0.127) RAD MIN .009 – .013 (0.229 – 0.330) NOTE: 1. DIMENSIONS IN .291 – .299 (7.391 – 7.595) NOTE 4 .010 – .029 × 45° (0.254 – 0.737) 1 2 3 4 5 6 7 8 9 .093 – .104 (2.362 – 2.642) 10 .037 – .045 (0.940 – 1.143) 0° – 8° TYP .050 (1.270) BSC NOTE 3 .016 – .050 (0.406 – 1.270) .014 – .019 (0.356 – 0.482) TYP .004 – .012 (0.102 – 0.305) S20 (WIDE) 0502 INCHES (MILLIMETERS) 2. DRAWING NOT TO SCALE 3. PIN 1 IDENT, NOTCH ON TOP AND CAVITIES ON THE BOTTOM OF PACKAGES ARE THE MANUFACTURING OPTIONS. THE PART MAY BE SUPPLIED WITH OR WITHOUT ANY OF THE OPTIONS 4. THESE DIMENSIONS DO NOT INCLUDE MOLD FLASH OR PROTRUSIONS. MOLD FLASH OR PROTRUSIONS SHALL NOT EXCEED .006" (0.15mm) 1290fe Information furnished by Linear Technology Corporation is believed to be accurate and reliable. However, no responsibility is assumed for its use. Linear Technology Corporation makes no representation that the interconnection of circuits as described herein will not infringe on existing patent rights. 31 LTC1290 RELATED PARTS PART NUMBER DESCRIPTION COMMENTS LTC1286/LTC1298 12-Bit, Micropower Serial ADC in SO-8 1- or 2-Channel, Autoshutdown LTC1293/LTC1294/LTC1296 12-Bit, Multiplexed Serial ADC 6-, 8- or 8-Channel with Shutdown Output LTC1594/LTC1598 12-Bit, Micropower Serial ADC 4- or 8-Channel, 3V Versions Available 1290fe 32 Linear Technology Corporation 1630 McCarthy Blvd., Milpitas, CA 95035-7417 (408) 432-1900 ● FAX: (408) 434-0507 ● www.linear.com LT/LT 0805 REV E • PRINTED IN USA © LINEAR TECHNOLOGY CORPORATION 1991