Minmax MFU113 Dc/dc converter 1w miniature dip-package with industry standard pinout Datasheet

MFU100 SERIES
DC/DC CONVERTER 1W
FEATURES
►Miniature DIP-Package with Industry Standard Pinout
►Package Dimension:
12.7 x 7.0 x 10.2 mm (0.50”x 0.28”x 0.40” inches)
►High I/O-Isolation 3000 VDC
►Operating Temp. Range -40°C to +85°C
►3 Years Product Warranty
PRODUCT OVERVIEW
The MINMAX MFU100 series is a range of 1W DC/DC converters in a miniature DIP Package featuring I/O-isolation of 3000VDC. A high efficiency allows
an operating temperature range of –40°C to +85°C.
These converters offer an economical solution for many space critical applications where a voltage has to be isolated i.e for noise reduction, ground loop
elimination, digital interfaces or for board level power distribution.
Model Selection Guide
Model
Input
Output
Number
Voltage
Voltage
(Range)
VDC
MFU102
MFU103
MFU104
MFU105
MFU112
MFU113
MFU114
MFU115
MFU122
MFU123
MFU124
MFU125
5
(4.5 ~ 5.5)
12
(10.8 ~ 13.2)
24
(21.6 ~ 26.4)
VDC
5
9
12
15
5
9
12
15
5
9
12
15
Output Current
Input Current
Max.
Min.
@Max. Load
@No Load
mA
200
110
84
67
200
110
84
67
200
110
84
67
mA
4
2
1.5
1
4
2
1.5
1
4
2
1.5
1
mA(typ.)
290
260
262
257
117
107
106
106
60
54
53
53
mA(typ.)
Load
Max. capacitive
Regulation
Load
Efficiency
(typ.)
@Max. Load
% (max.)
11
8
7
6
9
5
5
4
8
5
4
4
30
13
10
uF
33
33
33
%
69
76
77
78
71
77
79
79
70
76
79
79
# For each output
Input Specifications
Parameter
Model
Input Voltage Range
Input Surge Voltage (1 sec. max.)
4.5
5
5.5
10.8
12
13.2
24V Input Models
21.6
24
26.4
5V Input Models
-0.7
---
7
12V Input Models
-0.7
---
15
24V Input Models
-0.7
---
28
---
---
0.3
Internal Power Dissipation
Tel:886-6-2923150
Page 1 of 4
Unit
VDC
A
Internal Capacitor
---
E-mail:[email protected]
Max.
5V Input Models
All Models
Input Filter
Typ.
12V Input Models
Reverse Polarity Input Current
2012/01/09 REV:6
Min.
---
450
mW
MFU100 SERIES
DC/DC CONVERTER 1W
Output Specifications
Parameter
Conditions
Min.
Typ.
Max.
---
±1.0
±3.0
%
---
±1.2
±1.5
%
Output Voltage Accuracy
Line Regulation
For Vin Change of 1%
Load Regulation
Io=20% to 100%
Ripple & Noise (20MHz)
Ripple & Noise (20MHz)
Over Line, Load & Temp.
Unit
See Model Selection Guide
---
100
150
mV P-P
---
---
200
mV P-P
Ripple & Noise (20MHz)
---
---
15
mV rms
Temperature Coefficient
---
±0.01
±0.02
%/℃
Short Circuit Protection
0.5 Second Max.
General Specifications
Parameter
I/O Isolation Voltage (rated)
Conditions
Min.
Typ.
Max.
Unit
60 Seconds
3000
---
---
VDC
I/O Isolation Resistance
500 VDC
10
---
---
GΩ
I/O Isolation Capacitance
100KHz, 1V
---
60
100
pF
50
90
110
KHz
2,000,000
---
---
Hours
Switching Frequency
MTBF (calculated)
MIL-HDBK-217F@25℃, Ground Benign
Input Fuse
5V Input Models
500mA Slow-Blow Type
12V Input Models
200mA Slow-Blow Type
24V Input Models
100mA Slow-Blow Type
Environmental Specifications
Parameter
Operating Temperature Range (with Derating)
Case Temperature
Storage Temperature Range
Humidity (non condensing)
Cooling
Lead Temperature (1.5mm from case for 10Sec.)
Conditions
Ambient
Min.
-40
---50
--Free-Air convection
---
Max.
+85
+90
+125
95
Unit
℃
℃
℃
% rel. H
260
℃
Power Derating Curve
100
100
Natural
convection
80
Natural
convection
80
100LFM
100LFM
200LFM
60
200LFM
60
400LFM
400LFM
40
40
20
20
0
0
~
-40
0
20
40
60
80
100 110
Ambient Temperature ]
(5V Output Only)
~
-40
0
20
40
60
80
100 110
Ambient Temperature ]
(All Other Output)
Notes
1
Specifications typical at Ta=+25℃, resistive load, nominal input voltage and rated output current unless otherwise noted.
2
Ripple & Noise measurement bandwidth is 0-20MHz.
3
These power converters require a minimum output loading to maintain specified regulation, operation under no-load conditions will not damage these
4
All DC/DC converters should be externally fused at the front end for protection.
modules; however they may not meet all specifications listed.
5
Other input and output voltage may be available, please contact factory.
6
That “natural convection” is about 20LFM but is not equal to still air (0 LFM).
7
Specifications subject to change without notice.
E-mail:[email protected]
2012/01/09 REV:6
Tel:886-6-2923150
Page 2 of 4
MFU100 SERIES
DC/DC CONVERTER 1W
Package Specifications
Pin Connections
2.54
[0.10]
0.50
[0.02]
7.62 [0.30]
Bottom View
7
5
-Vin
4
+Vin
5
+Vout
7
-Vout
L=8.0 [0.31] for 24V Input Models
10.2 [0.40]
4
Function
1
L=7.0 [0.28] for 5V & 12V Input Models
2.6
[0.10]
7.62 [0.30]
1
Pin
L
3.1
[0.12]
0.4 [0.02]
Mechanical Dimensions
12.7 [0.50]
1.29
[0.05]
►All
5.08
[0.20]
dimensions in mm (inches)
►Tolerance: X.X±0.25
►Pin
Physical Characteristics
Case Size(5V&12V Input)
:
12.7x7.0x10.2mm (0.50x0.28x0.40 Inches)
Case Size(24V Input)
:
12.7x8.0x10.2mm (0.50x0.31x0.40 Inches)
Case Material
:
Non-Conductive Black Plastic (flammability to UL 94V-0 rated)
Weight(5V&12V Input)
:
1.3g
Weight(24V Input)
:
1.7g
E-mail:[email protected]
2012/01/09 REV:6
Tel:886-6-2923150
Page 3 of 4
(X.XX±0.01)
X.XX±0.13 ( X.XXX±0.005)
diameter  0.5 ±0.05 (0.02±0.002)
MFU100 SERIES
DC/DC CONVERTER 1W
Test Configurations
Peak-to-Peak Output Noise Measurement Test
Use a Cout 0.33uF ceramic capacitor. Scope measurement should be made by using a BNC socket, measurement bandwidth is 0-20 MHz. Position the load
between 50 mm and 75 mm from the DC/DC Converter.
+Vin
+Out
Copper Strip
Single Output
DC / DC
Converter
-Vin
Cout
-Out
Scope
Resistive
Load
Copper Strip
Design & Feature Considerations
Maximum Capacitive Load
The MFU100 series has limitation of maximum connected capacitance at the output. The power module may be operated in current limiting mode during start-up,
affecting the ramp-up and the startup time. For optimum performance we recommend 33uF maximum capacitive load for devices. The maximum capacitance can be
found in the data sheet..
Input Source Impedance
The power module should be connected to a low ac-impedance input source. Highly inductive source impedances can affect the stability of the power module.
In applications where power is supplied over long lines and output loading is high, it may be necessary to use a capacitor at the input to ensure startup.
Capacitor mounted close to the power module helps ensure stability of the unit, it is recommended to use a good quality low Equivalent Series Resistance (ESR <
1.0Ω at 100 KHz) capacitor of a 1.5uF for the 5V input devices, a 1.0uF for the 12V input devices and a 0.47uF for the 24V devices.
+
DC Power
Source
+Vin
+
+Out
DC / DC
Converter
Load
Cin
-
-Vin
-Out
Output Ripple Reduction
A good quality low ESR capacitor placed as close as practicable across the load will give the best ripple and noise performance.
To reduce output ripple, it is recommended to use 1uF capacitors at the output.
+
+Vin
DC Power
Source
-
+Out
Single Output
DC / DC
Converter
-Vin
Cout
Load
-Out
Thermal Considerations
Many conditions affect the thermal performance of the power module, such as orientation, airflow over the module and board spacing. To avoid exceeding the
maximum temperature rating of the components inside the power module, the case temperature must be kept below 90℃. The derating curves are determined from
measurements obtained in a test setup.
Position of air velocity
probe and thermocouple
15mm / 0.6in
50mm / 2in
Air Flow
DUT
18, Sin Sin Road, An-Ping Industrial District, Tainan 702, Taiwan
Tel: 886-6-2923150 Fax: 886-6-2923149 E-mail: [email protected]
Minmax Technology Co., Ltd.
2012/01/09 REV:6
Page 4 of 4
Similar pages