XP Power ECS60US05 It & medical safety approval Datasheet

ECS25,45 & 60 Series
•
IT & Medical Safety Approvals
•
Very Small 2.0” x 3.0” Format
•
Low Standby Power
•
25, 45 & 60 W - Convection Cooled Ratings
•
High Convection Cooled Power Density up to 9.5 W/in3
•
Class I & Class II Installations
•
-20 ºC to +70 ºC Operation
•
Low Earth Leakage Current
•
3 Year Warranty
The ECS25, 45 & 60 Series has been designed to minimise the no load power consumption and maximise efficiency in order to
facilitate equipment design to the latest environmental legislation.
Approved for Class I and Class II applications, this range of single output AC-DC power supplies feature very high convection cooled
power density in an industry leading 2” x 3" (51.0 mm x 76.2 mm) footprint. The very low profile, 1U compatible supplies meet
EN55011/22 Level B conducted emissions with low earth leakage currents of 80 µA at 115 VAC or 160 µA at 230 VAC. Making these
switchers ideal for industrial, IT and medical applications.
The series has single output versions from 5 V to 48 VDC, adjustable by ±10%. They are dual-fused for compliance with IEC60601-1
and efficiency up to 89%, so minimal excess heat is generated. They will deliver up to 60 W of power at +50 °C and up to +70 °C
with derating.
xppower.com
Models and Ratings
Output Power - Convection Cooled
Output Voltage V1
Max Output Current
25 W
12.0 VDC
2.08 A
25 W
15.0 VDC
1.67 A
25 W
24.0 VDC
1.04 A
25 W
48.0 VDC
0.52 A
30 W
5.0 VDC
6.00 A
45 W
12.0 VDC
3.75 A
45 W
15.0 VDC
3.00 A
45 W
24.0 VDC
1.90 A
45 W
48.0 VDC
0.95 A
40 W
5.0 VDC
8.00 A
Notes:
60 W
12.0 VDC
5.00 A
derate
1. For covered versions,
VDC for use in class II installations,4.00
A output by 20% with cover.
60 W add suffix ‘-C’ to model number. Not
15.0suitable
60 W
24.0 VDC
2.50 A
60 W
48.0 VDC
1.25 A
Model Number(1)
ECS25US12
ECS25US15
ECS25US24
ECS25US48
ECS45US05
ECS45US12
ECS45US15
ECS45US24
ECS45US48
ECS60US05(
ECS60US12
ECS60US15
ECS60US24
ECS60US48
Notes
1. For covered versions, add suffix ‘-C’ to model number or order part number ECS25-60 COVER KIT for standalone cover. Not suitable for use in class II installations,
derate output power by 20% with cover.
Input Characteristics
Characteristic
Minimum
Typical
Maximum
Units
Notes & Conditions
Input Voltage - Operating
80
115/230
264
VAC
Derate output power < 90 VAC. See fig. 1
Input Frequency
47
50/60
400
Hz
>0.5
Power Factor
Agency approval 47-63 Hz
230 VAC, 100% load
EN61000-3-2 class A compliant
Input Current - No Load
0.01/0.02
A
115/230 VAC
Input Current - Full Load
0.45/0.25
0.75/0.45
0.95/0.60
A
115/230 VAC - ECS25
115/230 VAC - ECS45
115/230 VAC - ECS60
230 VAC cold start, 25 °C
Inrush Current
40
A
0.3
0.5
W
115/230 VAC
80/160
260
µA
115/230 VAC/50 Hz (Typ.), 264 VAC/60 Hz (Max.)
mA
115/230 VAC/400 Hz
Maximum
Units
Notes & Conditions
48
VDC
See Models and Ratings table
±1
%
50% load, 115/230 VAC
±10
%
Via potentiometer. See mech. details (page 9)
0
A
No Load Input Power
Earth Leakage Current
Input Protection
0.6/1.2
T3.15A/250 V internal fuse in both line and neutral
Output Characteristics
Characteristic
Output Voltage - V1
Minimum
Typical
5.0
Initial Set Accuracy
Output Voltage Adjustment
Minimum Load
Start Up Delay
Hold Up Time
1
s
16
115 VAC full load (see fig.3)
Drift
±0.2
%
After 20 min warm up
Line Regulation
±0.5
%
90-264 VAC
Load Regulation
±1
%
0-100% load.
4
%
Recovery within 1% in less than 500 µs
for a 50-75% and 75-50% load step
1
% pk-pk
Transient Response - V1
Over/Undershoot - V1
3
Ripple & Noise
%
Overvoltage Protection
115
140
%
Overload Protection
110
200
% I nom
0.05
%/˚C
Short Circuit Protection
Temperature Coefficient
Overtemperature Protection
2
230 VAC full load (see fig.2)
ms
See fig.4
20 MHz bandwidth (see fig.5 & 6)
Vnom DC.
Auto reset (see fig.7)
Continuous, trip & restart (hiccup mode)
°C
Not fitted
xppower.com
Input Voltage Derating
100
Figure. 1
Output Power (%)
90
80
70
60
50
40
80
85
264
90
Input Voltage (VAC)
Start Up Delay From AC Turn On
Figure 2
Start up example from AC turn on
(230 VAC, 720 ms)
Hold Up Time From Loss of AC
Figure 3
Hold up example ECS45 at 45 W
load with 115 VAC input (17.2ms)
3
xppower.com
Typical Output Overshoot
Figure 4
Typical Output Overshoot
(ECS45US12, 230 VAC)
Output Ripple & Noise
Figure 5
ECS45US12 (45 W)
72 mV pk-pk ripple. 20 MHz BW
4
xppower.com
Output Ripple & Noise cont.
Figure 6
ECS45US48 (45 W)
188 mV pk-pk ripple. 20 MHz BW
Output Overload Characteristic
14
12
Figure 7
Typical Overload
Characteristic
(ECS45US12 shown)
Output Volts (V)
10
Output enters
Trip & Restart Mode
8
6
4
2
0
0
0.1
0.2
0.3
0.9
1.0
1.1
1.2
1.3
Output Current (A)
5
xppower.com
Xxxxxxxxxx
General
Specifications
Characteristic
Minimum
Typical
Maximum
87
Efficiency
VAC
500
VDC
65
kHz
Power Density
7.9
W/in3
1072
Mean Time Between Failure
kHrs
660
0.22 (100)
Weight
lb (g)
Efficiency Versus Load
88%
86%
84%
Efficiency
Full load (see fig.8 & 9)
1500
Switching Frequency
82%
80%
78%
76%
0%
20%
40%
60%
80%
100%
% of Output Load
Figure 8
ECS45US12 at 230 VAC
90%
88%
Efficiency
86%
84%
82%
80%
78%
76%
74%
0%
20%
40%
60%
Output Load
80%
Figure 9
ECS45US48 at 230 VAC
6
Notes & Conditions
%
VAC
4000
Isolation: Input to Output
Input to Ground
Output to Ground
Units
100%
MIL-HDBK-217F, Notice 2 +25 °C GB
MIL-HDBK-217F, Notice 2 +50 °C GB
xppower.com
Xxxxxxxxxx
Environmental
Characteristic
Minimum
Typical
Maximum
Units
Operating Temperature
-20
+70
°C
Storage Temperature
-40
+85
°C
Notes & Conditions
Derate linearly from +50 °C at 2.5%/°C
to 50% at 70 °C. (See fig.10 & Thermal
Considerations)
Convection cooled, see fig.10 & Thermal
Considerations
Cooling
Humidity
5
Operating Altitude
95
%RH
3000
m
Non-condensing
Shock
3 x 30 g/11 ms shocks in both +ve & -ve
directions along the 3 orthogonal axis,
total 18 shocks.
Vibration
Three axis 5-500 Hz at 2 g x 10 sweeps
Derating Curve
Figure 10
Output Power (%)
100
50
0
264
-20
7
50
Ambient Temperature (ºC)
Electromagnetic Compatibility - Immunity
Phenomenon
Standard
Test Level
Criteria
EN61204-3
High severity level
as below
Harmonic Current
EN61000-3-2
Class A
Radiated
EN61000-4-3
3
A
EFT
EN61000-4-4
3
A
Surges
EN61000-4-5
Installation class 3
A
Conducted
EN61000-4-6
3
A
Low Voltage PSU EMC
EN61000-4-11
Dips and Interruptions
EN60601-1-2
Dip:
30% 10 ms
A
Dip:
60% 100 ms
B
Dip: 100% 5000 ms
B
Dip:
30% 500 ms
A
Dip:
60% 100 ms
A
Dip:
100% 10 ms
A
Int.: >95% 5000 ms
B
Notes & Conditions
Load derating with 115 VAC input (typically
45% derate dependant on model & load)
7
xppower.com
Electromagnetic Compatibility - Emissions
Standard
Test Level
Conducted
Phenomenon
EN55011/22
Class B
Radiated
EN55011/22
Voltage Fluctuations
Criteria
Notes & Conditions
Class B
ECS25
Class A
ECS45/ECS60
EN61000-3-3
Safety Agency Approvals
Safety Agency
Safety Standard
Category
CB Report
IEC60950-1:2005 Ed 2
Information Technology
UL
UL60950-1 (2007), CSA 22.2 No.60950-1-07 Ed 2
Information Technology
TUV
EN60950-1:2006
Information Technology
CE
LVD
Safety Agency
Safety Standard
Category
CB Report
IEC60601-1 Ed 3 Including Risk Management
Medical
UL
ANSI/AAMI ES60601-1:2005 & CSA C22.2, No.60601-1:08
Medical
TUV
EN60601-1/A12:2006
Medical
Primary to Secondary
2 x MOPP (Means of Patient Protection)
Primary to Earth
1 x MOPP (Means of Patient Protection)
Secondary to Earth
1 x MOPP (Means of Patient Protection)
Equipment Protection Class
Safety Standard
Notes & Conditions
IEC60950-1:2005 Ed 2 & IEC60601-1 Ed 2
See safety agency conditions of acceptibility
for details
Means of Protection
Class I & Class II
Category
IEC60601-1 Ed 3
Mechanical Details - ECS25
4X Ø.156 [3.96] MOUNTING HOLES
Ø.312 [7.92] CLEARANCE TOP AND BOTTOM
2.75 [69.8]
2
1
2
J1
1
C5
3
C18
J2
4
2.00 [50.8]
1.75 [44.4]
1.65 [41.8]
1.31 [33.3]
.27 [7.0]
T1
Q1
.25 FASTON
GROUND TAB
.20 [5.1]
Input Connector J1
Molex PN 09-65-2038
Pin 1
Line
Pin 2
Neutral
0.25” Faston
Earth
3.00 [76.2]
.95 [24.2]
.14 [3.6]
SMD HEIGHT
Notes
1. All dimensions in inches (mm).
Tolerance .xx = ±0.02 (0.50); .xxx = ±0.01 (0.25)
8
2. Weight 0.22 lbs (100 g)
Input Connector J2
Molex PN 09-65-2048
Pin 1
+V1
Pin 2
+V1
Pin 3
RTN
Pin 4
RTN
J1 mates with Molex Housing PN
09-50-1031, J2 mates with Molex
Housing PN 09-50-1041 and both with
Molex Series 5194 Crimp Terminals
.
xppower.com
.
Xxxxxxxxxx Details - ECS45US05
Mechanical
Weight: 2.20 lbs (1000 g)
Dimensions shown in inches (mm).
Input Connector J1
Molex PN 09-65-2038
Pin 1
Line
Pin 2
Neutral
0.25” Faston
Earth
4X Ø.156 [3.96] MOUNTING HOLES
Ø.312 [7.92] CLEARANCE TOP AND BOTTOM
2.75 [69.9]
2
J1
1
1
2
C18
C5
4
1.75 [44.5]
Input Connector J2
Molex PN 09-65-2048
Pin 1
+V1
Pin 2
+V1
Pin 3
RTN
Pin 4
RTN
J2
3
XP
1.30 [33.0]
2.00 [50.8]
1.58 [40.3]
T1
Q1
.20 [5.1]
.25 FASTON
GROUND TAB
.28 [7.0]
J1 mates with Molex
Housing PN
09-50-1031, J2 mates with
Molex Housing PN 09-501041 and both with Molex
Series 5194 Crimp Terminals
3.00 [76.2]
1.05 [26.7]
.14 [3.6]
SMD HEIGHT LIMIT
ECS45US other models
4X Ø.156 [3.96] MOUNTING HOLES
Ø.312 [7.92] CLEARANCE TOP AND BOTTOM
2.75 [69.9]
Input Connector J1
Molex PN 09-65-2038
Pin 1
Line
Pin 2
Neutral
0.25” Faston
Earth
Input Connector J2
Molex PN 09-65-2048
Pin 1
+V1
Pin 2
+V1
Pin 3
RTN
Pin 4
RTN
J1 mates with Molex
Housing PN
09-50-1031, J2 mates with
Molex Housing PN 09-501041 and both with Molex
Series 5194 Crimp Terminals
2
1
2
J1
1
C5
C18
3
J2
4
2.00 [50.8]
1.75 [44.5]
1.65 [41.8]
XP
1.31 [33.3]
T1
Q1
.28 [7.0]
.25 FASTON
GROUND TAB
.20 [5.1]
3.00 [76.2]
.95 [24.2]
.14 [3.6]
SMD HEIGHT
Notes
1. All dimensions in inches (mm).
Tolerance .xx = ±0.02 (0.50); .xxx = ±0.01 (0.25)
2. Weight: 0.22 lbs (100 g)
9
xppower.com
Mechanical Details - ECS60
0.28 (7.1)
4 x ø0.156 (3.96) mounting holes
ø3.12 (7.92) clearance top and bottom
1.05 (26.7)
0.20 (5.1)
A
1
C5
2.00
(50.8)
J2
C18
1.75
(44.4)
4
1.62
(41.1)
1.30
(33.0)
T1
A
Q1
0.12
(3.18)
Components may
extend beyond
edge of PCB
by 0.04 (1.0)
0.25 faston ground tab
0.12
(3.1)
2.75 (69.8)
0.14 (3.5)
3.00 (76.2)
Mounting points A should be connected together for optimum EMI performance
Output Connector J2
Molex PN 09-65-2048
Input Connector J1
Molex PN 09-65-2038
Pin 1
Line
Pin 2
Neutral
0.25” Faston
Earth
J1 mates with Molex Housing PN 09-50-1031
Pin
Pin
Pin
Pin
1
2
3
4
J2 mates with Molex Housing PN 09-50-1041
and both with Molex Series 5194 Crimp Terminals
Notes
1. All dimensions in inches (mm).
Tolerance .xx = ±0.02 (0.50); .xxx = ±0.01 (0.25)
10
+V1
+V1
RTN
RTN
2. Weight: 0.22 lbs (100 g)
.
xppower.com
Xxxxxxxxxx
Version - All models
Covered
4X M3 X 0.5 THD
0.16 [4.0] MAX
SCREW PENETRATION
OUTPUT
CONNECTOR
J2
1
4
3.48
(88.4) 3.03
(76.9)
2 J1 1
0.22 (5.7)
INPUT
CONNECTOR
0.70
(17.79)
.25[0.6]FAST-ON
GROUND TERMINAL
TOP VIEW
1.23 (31.28)
1.40
(35.6)
4X M3 X 0.5 THD
0.16 [4.0] MAX
SCREW PENETRATION
1.26
(32.0)
0.63
(16.0)
0.22 (5.7)
3.031
[76.99]
2.52
(64.0)
BOTTOM VIEW
Thermal
Considerations
Xxxxxxxxxx
In order to ensure correct and reliable operation of the PSU in the most adverse conditions permitted in the end-use equipment, the temperature of the
components listed in the table below must not be exceeded. See mechanical drawings for component locations. Temperature should be monitored
using K type thermocouples placed on the hottest part of the component (out of any direct air flow).
Component
T1
Temperature Measurements (Ambient ≤ 50 ºC)
Max Temperature ºC
120 °C
Q1
110 °C
C5
105 °C
C18
105 °C
24 Mar 16