MPM-02V Series Ultra Wide Input, 2W Miniature, Board Mount AC/DC Power Supplies Electrical Specifications Key Features: Specifications typical @ +25°C, 230 VAC input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice. Input • 2W Output Power Parameter • Universal 85-305 VAC Input Input Voltage Range • EN 60950 Approved (UL) • Meets IEC Safety Class II Input Frequency Input Current • -25ºC to +70ºC Operation Inrush Current • Single Regulated Output Conditions Leakage Current • >300 kHour MTBF Output • Ultra-Miniature DIP Case Parameter Output Voltage Output Current Output Voltage Accuracy Line Regulation Load Regulation Ripple & Noise (20 MHz) Hold-Up Time Temperature Coefficient Short Circuit Protection Over Current Protection Min. Typ. 85 120 47 See Model Selection Guide 110 VAC 5.0 230 VAC 11.0 110/230 VAC Max. 305 430 63 Units VAC VDC Hz 0.15 mA Conditions Min. Typ. See Model Selection Guide See Model Selection Guide See Note 1 VIN = Min to Max See Note 2 100 115 VAC 30 230 VAC 140 ±0.02 Continuous (Autorecovery) >110% With Autorecovery Max. Units ±5.0 ±2.0 ±5.0 200 % % % mV Pk - Pk A Pk mSec %/°C General Parameter Isolation Voltage Conditions Input to Output Conducted Radiated Electrostatic Discharge (ESD) RF Field Susceptibility Electrical Fast Transients/Bursts On Mains Surge CS PFM Volt. Dips, Short & Inter. Immunity EMI/RFI, See Note 3 EMC Compliance Switching Frequency Min. 3,000 Typ. Max. Units VAC CISPR22/EN 55022 Level B CISPR22/EN 55022 Level B EN 61000-4-2 Level B 4 kV/8 kV EN 61000-4-3 Level A 10V/m EN 61000-4-4 Level B 2 kV EN 61000-4-5 Level B 1 kV/2 kV EN 61000-4-6 Level A 10V rms EN 61000-4-8 Level A 10A/m EN 61000-4-11 Level B 0 - 70% 100 kHz Environmental MicroPower Direct 292 Page Street Suite D Stoughton, MA 02072 USA T: (781) 344-8226 F: (781) 344-8481 E: [email protected] W: www.micropowerdirect.com Parameter Operating Temperature Range Storage Temperature Range Cooling Humidity Physical Case Size Case Material Weight Conditions Min. Typ. Max. -25 +25 +70 -40 +85 Free Air Convection (See Derating Curve) RH, Non-condensing 90 Ambient Units °C °C % 1.327 x 0.874 x 0.708 Inches (33.7 x 22.2 x 18.0 mm) Non-Conductive Black Plastic (UL94-V0) 0.70 Oz (20g) Reliability Specifications Parameter MTBF Safety Approvals Safety Class Conditions Min. Typ. MIL HDBK 217F, 25°C, Gnd Benign 300 UL 60950, EN 60950 IEC 61140 Class II www.micropowerdirect.com Max. Units kHours www.micropowerdirect.com Model Selection Guide Input Model Number MPM-02SV-03 MPM-02SV-05 MPM-02SV-09 MPM-02SV-12 MPM-02SV-15 MPM-02SV-24 Output Voltage Current Standby Power 115 VAC 230 VAC (VDC) (mA) (W Typ) (µF, Max) 44 44 44 44 44 44 25 25 25 25 25 25 3.3 5.0 9.0 12.0 15.0 24.0 600 400 222 167 133 83 0.1 0.1 0.1 0.1 0.1 0.1 4,000 4,000 2,200 2,200 1,000 680 Current (mA) Capacitive Load Efficiency (%, Typ) 65 70 72 76 76 78 N Notes: 1. Output voltage accuracy for 3.3V output models is ±6% Max. 2. Load regulation is measured for an output change of 10% to 100% at nominal input line. 3. The MPM-02V meets EN 55022 Class B without external components. For applications where noise sensitivity is critical, a recommended circuit is given below. 4. It is recommended that a fuse be used on the input of a power supply for protection. For the MPM-02V series, a 0.5A/250 VAC slow blow should be used. Typical Connection The diagram above illustrates a typical application connection of the MPM-02V series. Notes on this circuit (starting with the input circuit) are: Mechanical Dimensions 1. To maintain clearance and creepage distances (for Class I & Class II devices) the board layout should guarantee the following spacing between the L and N inputs (before the fuse): Clearance - 2 mm Creepage - 2.5 mm 2. The recommended fuse is a 0.5A/250V slow blow. Additionally, a thermistor (NTC) may be used on the input line. A 5D-9 is recommended. 3. For EMI sensitive applications, the input filtering circuit (inside the dotted boxes) may be added. The filter consists of: Cx: Capacitor C3 is 0.1 µF/300V to 0.33 µF/300V CY: Capacitors C1 and C2 are 2200 pF/400V T1: Common mode choke. Inductance is about 10 mH to 30 mH. 4. The MOV is required for surge protection. Recommended is a 561KD14. 5. The output filtering capacitor (C5) is a high frequency, low resistance electrolytic capacitor. A ceramic capacitor (C4) is used to filter high frequency noise. Recommended values are given in the table at right. 6. The TVS is recommended to protect application circuitry in the event of a fault. Recommended values are given in the table at right. VOUT C4 C5 TVS 3.3 5.0 9.0 12.0 15.0 24.0 1 µF/50V 1 µF/50V 1 µF/50V 1 µF/50V 1 µF/50V 1 µF/50V 220 µF 220 µF 120 µF 120 µF 120 µF 68 µF SMBJ7.0A SMBJ7.0A SMBJ12A SMBJ20A SMBJ20A SMBJ30A Derating Curve Notes: • All dimensions are typical in inches (mm) • Tolerance x.xx = ±0.01 (±0.25) Pin Connections Pin 1 2 3 4 MicroPower Direct We Power Your Success - For Less! 292 Page Street Ste D Stoughton, MA 02072 • TEL: (781) 344-8226 • FAX: (781) 344-8481 • Function AC-Neutral AC-Line -Vout +Vout E-Mail: [email protected]