FEATURES
►SIP Package with Industry Standard Pinout
►Package Dimension:
19.5 x 10.2 x 6.1 mm (0.77”x 0.4”x 0.24”) 5V&12V Models
19.5 x 10.2 x 7.1 mm (0.77”x 0.4”x 0.28”) 24V Models
►Single and Dual Output Models
►I/O-Isolation 3000 VDC
►Operating Temp. Range -40°C to +85°C
►3 Years Product Warranty
PRODUCT OVERVIEW
The MAU200 series is a range of 1W DC/DC converters in a small SIP Package featuring high I/O-isolation of 3000VDC.
An excellent efficiency allows an operating temperature range of –40°C to +85°C.
These converters offer an economical solution for many applications where a voltage has to be isolated i.e for noise reduction, ground loop elimination,
digital interfaces or for board level power distribution where a higher I/O-isolation is required.
Model Selection Guide
Model
Number
MAU201
MAU202
MAU203
MAU204
MAU205
MAU206
MAU207
MAU208
MAU209
MAU211
MAU212
MAU213
MAU214
MAU215
MAU216
MAU217
MAU218
MAU219
MAU221
MAU222
MAU223
MAU224
MAU225
MAU226
MAU227
MAU228
MAU229
Input
Voltage
(Range)
VDC
5
(4.5 ~ 5.5)
12
(10.8 ~ 13.2)
24
(21.6 ~ 26.4)
Output
Voltage
VDC
3.3
5
9
12
15
±5
±9
±12
±15
3.3
5
9
12
15
±5
±9
±12
±15
3.3
5
9
12
15
±5
±9
±12
±15
In
Total Power International,
Inc
Output Current
Max.
mA
260
200
110
84
67
±100
±56
±42
±34
260
200
110
84
67
±100
±56
±42
±34
260
200
110
84
67
±100
±56
±42
±34
Min.
mA
5
4
2
1.5
1
±2
±1
±0.8
±0.7
5
4
2
1.5
1
±2
±1
±0.8
±0.7
5
4
2
1.5
1
±2
±1
±0.8
±0.7
Input Current
@Max. Load
mA(typ.)
235
281
260
258
258
278
262
258
258
96
114
106
105
104
113
106
104
105
49
59
54
54
53
58
55
53
53
@No Load
mA(typ.)
Toll Free: 877-646-0900
30
12
7
Load
Regulation
Max. capacitive
Load
% (max.)
10
10
8
7
7
10
8
7
7
8
8
5
5
5
8
5
5
5
8
8
5
5
5
8
5
5
5
µF
Efficiency
(typ.)
@Max. Load
220
100#
220
100#
220
100#
# For each output
www.total-power.com
%
73
71
76
78
78
72
77
78
79
74
73
78
80
80
74
79
81
81
73
71
76
78
79
72
76
79
80
MAU200 SERIES
Total Power International, Inc.
Input Specifications
Parameter
Input Voltage Range
Input Surge Voltage (1 sec. max.)
Reverse Polarity Input Current
Internal Filter Type
Internal Power Dissipation
Output Specifications
Parameter
Output Voltage Accuracy
Output Voltage Balance
Line Regulation
Load Regulation
Ripple & Noise
Temperature Coefficient
Short Circuit Protection
Model
5V Input Models
12V Input Models
24V Input Models
5V Input Models
12V Input Models
24V Input Models
Parameter
I/O Isolation Voltage (rated)
I/O Isolation Resistance
I/O Isolation Capacitance
Switching Frequency
MTBF (calculated)
Input Fuse
Dual Output, Balanced Loads
For Vin Change of 1%
Io=20% to 100%
max. 20MHz Bandwidth
Min.
-----------
Conditions
60 Seconds
500 VDC
100KHz, 1V
MIL-HDBK-217F@25℃, Ground Benign
5V Input Models
12V Input Models
200mA Slow-Blow Type
Parameter
Operating Ambient Temperature Range (See Power Derating Curve)
Case Temperature
Storage Temperature Range
Humidity (non condensing)
Cooling
Lead Temperature (1.5mm from case for 10Sec.)
In
Total Power International,
Inc
---
Conditions
500mA Slow-Blow Type
Environmental Specifications
Min.
4.5
10.8
21.6
-0.7
-0.7
-0.7
---
All Models
General Specifications
DC/DC CONVERTER 1W, SIP-Package, High Isolation
Conditions
Natural Convection
Toll Free: 877-646-0900
Typ.
Max.
5
5.5
12
13.2
24
26.4
--9
--18
--30
--0.3
Internal Capacitor
--450
Unit
VDC
A
mW
Typ.
Max.
±1.0
±3.0
±0.1
±1.0
±1.2
±1.5
See Model Selection Guide
65
100
±0.01
±0.02
0.5 Second Max.
Min.
3000
10
--70
2,000,000
Typ.
----60
100
---
Max.
----100
120
---
Unit
%
%
%
mV P-P
%/℃
Unit
VDC
GΩ
pF
KHz
Hours
24V Input Models
100mA Slow-Blow Type
Min.
-40
---50
--Free-Air convection
---
Max.
+85
+90
+125
95
Unit
℃
℃
℃
% rel. H
260
℃
www.total-power.com
Total Power International, Inc.
MAU200 SERIES
DC/DC CONVERTER 1W, SIP-Package, High Isolation
Power Derating Curve
100
Output Power (%)
Natural
Convection
20LFM
80
100LFM
60
200LFM
400LFM
40
20
0
-40
~
0
20
40
60
100 110
80
Ambient Temperature C
(3.3V, 5V & ±5V}
Notes
1
2
3
4
5
6
7
(all other output)
Specifications typical at Ta=+25℃, resistive load, nominal input voltage and rated output current unless otherwise noted.
Ripple & Noise measurement bandwidth is 0-20MHz.
These power converters require a minimum output loading to maintain specified regulation, operation under no-load conditions will not damage these
modules; however they may not meet all specifications listed.
All DC/DC converters should be externally fused at the front end for protection.
Other input and output voltage may be available, please contact factory.
That “natural convection” is about 20LFM but is not equal to still air (0 LFM).
Specifications are subject to change without notice.
Package Specifications
Mechanical Dimensions
Pin Connections
Pin
19.5 [0.77]
1
5
0.5
6
[0.13]
3.2
10.2 [0.40]
0.5 [0.02]
2
2.54
7.62
2X2.54
[0.10]
[0.30]
[2X0.10]
+Vin
Dual Output
-Vin
-Vout
No Pin
+Vout
+Vin
-Vin
-Vout
Common
+Vout
T: 6.1mm(0.24 inch) for 5V&12V Input Models
[0.02]
2.4
[0.09]
7
Single Output
T: 7.1mm(0.28 inch) for 24V Input Models
18.5 [0.73]
T
Bottom View
0.50
[0.02]
Physical Characteristics
Case Size (5V&12V Input)
Case Size (24V Input)
Case Material
Pin Material
Weight (5V&12V Input)
Weight (24V Input)
5
6
:
:
19.5x6.1x10.2mm (0.77x0.24x0.40 inches)
19.5x7.1x10.2mm (0.77x0.28x0.40 inches)
:
Alloy 42
:
:
:
►All dimensions in mm (inches)
►Tolerance: X.X±0.25 (X.XX±0.01)
7
0.25 [0.01]
2
1.3 [0.05]
1
X.XX±0.13 ( X.XXX±0.005)
► Pins ±0.05(±0.002)
Non-Conductive Black Plastic (flammability to UL 94V-0 rated)
2.2g
2.6g
In
Total Power International,
Inc
Toll Free: 877-646-0900
www.total-power.com
MAU200 SERIES
Total Power International, Inc.
DC/DC CONVERTER 1W, SIP-Package, High Isolation
Test Setup
Peak-to-Peak Output Noise Measurement Test
Use a Cout 0.33µF ceramic capacitor. Scope measurement should be made by using a BNC socket, measurement bandwidth is 0-20 MHz. Position the load
between 50 mm and 75 mm from the DC/DC Converter.
+Vin
+Out
Copper Strip
Single Output
DC / DC
Converter
-Vin
Cout
-Out
Resistive
Load
Scope
Copper Strip
+Vin
+Out
Copper Strip
Dual Output
DC / DC
Converter
Com.
Copper Strip
-Vin
-Out
Scope
Cout
Cout
Resistive
Load
Scope
Copper Strip
Technical Notes
Maximum Capacitive Load
The MAU200 series has limitation of maximum connected capacitance at the output. The power module may be operated in current limiting mode during start-up,
affecting the ramp-up and the startup time. For optimum performance we recommend 100µF maximum capacitive load for dual outputs and 220µF capacitive load
for single outputs. The maximum capacitance can be found in the data sheet.
Input Source Impedance
The power module should be connected to a low ac-impedance input source. Highly inductive source impedances can affect the stability of the power module. In
applications where power is supplied over long lines and output loading is high, it may be necessary to use a capacitor at the input to ensure startup.
Capacitor mounted close to the power module helps ensure stability of the unit, it is recommended to use a good quality low Equivalent Series Resistance (ESR <
1.0Ω at 100 KHz) capacitor of a 2.2µF for the 5V input devices, a 1.0µF for the 12V input devices and a 0.47µF for the 24V devices.
+
DC Power
Source
+Vin
+
+Out
DC / DC
Converter
Load
Cin
-
-Vin
-Out
Output Ripple Reduction
A good quality low ESR capacitor placed as close as practicable across the load will give the best ripple and noise performance. To reduce output ripple, it is
recommended to use 1.0µF capacitors at the output.
+
+Vin
DC Power
Source
-
+Out
Single Output
DC / DC
Converter
-Vin
+
Cout
Load
-Out
+Vin
DC Power
Source
-
+Out
Dual Output
DC / DC Com.
Converter
-Vin
-Out
Cout
Load
Load
Cout
Thermal Considerations
Many conditions affect the thermal performance of the power module, such as orientation, airflow over the module and board spacing. To avoid exceeding the
maximum temperature rating of the components inside the power module, the case temperature must be kept below 90℃. The derating curves are determined from
measurements obtained in a test setup.
Position of air velocity
probe and thermocouple
50mm / 2in
15mm / 0.6in
In
Total Power International,
Inc
Air Flow
DUT
Toll Free: 877-646-0900
www.total-power.com