Data Delay MDU13H-30C3 Triple, ecl-interfaced fixed delay line (series mdu13h) Datasheet

MDU13H
data 3 
delay
devices, inc.
TRIPLE, ECL-INTERFACED
FIXED DELAY LINE
(SERIES MDU13H)
FEATURES
•
•
•
•
PACKAGES
Three independent delay lines
Fits standard 16-pin DIP socket
Auto-insertable
Input & outputs fully 10KH-ECL interfaced & buffered
GND
1
I1
5
I2
6
I3
7
VEE
8
16
GND
15
O1
14
O2
13
O3
GND
N/C
N/C
N/C
I1
I2
I3
VEE
MDU13H-xx DIP
MDU13H-xxM Military DIP
1
2
3
4
5
6
7
8
16
15
14
13
12
11
10
9
GND
O1
O2
O3
N/C
N/C
N/C
N/C
MDU13H-xxC3 SMD
MDU13H-xxMC3 Mil SMD
FUNCTIONAL DESCRIPTION
PIN DESCRIPTIONS
The MDU13H-series device is a 3-in-1 digitally buffered delay line. The
signal inputs (I1-I3) are reproduced at the outputs (O1-O3), shifted in time
by an amount determined by the device dash number (See Table). The
delay lines function completely independently of each other.
I1-I3
O1-O3
VEE
GND
Signal Inputs
Signal Outputs
-5 Volts
Ground
SERIES SPECIFICATIONS
DASH NUMBER SPECIFICATIONS
•
•
•
•
•
•
Part
Number
MDU13H-3
MDU13H-4
MDU13H-5
MDU13H-10
MDU13H-15
MDU13H-20
MDU13H-25
MDU13H-30
MDU13H-35
MDU13H-40
MDU13H-45
MDU13H-50
Minimum input pulse width: 50% of total delay
Output rise time: 2ns typical
Supply voltage: -5VDC ± 5%
Power dissipation: 200mw typical (no load)
Operating temperature: -30° to 85° C
Temp. coefficient of total delay: 100 PPM/°C
O1
O2
O3
100%
100%
100%
Delay Per
Line (ns)
3 ± 1.0
4 ± 1.0
5 ± 1.0
10 ± 1.0
15 ± 1.0
20 ± 1.0
25 ± 2.0
30 ± 2.0
35 ± 2.0
40 ± 2.0
45 ± 2.2
50 ± 2.5
* Total delay is referenced to first tap output
Input to first tap = 1.5ns ± 1ns
NOTE: Any dash number between 3 and 50
not shown is also available.
VCC
I1
I2
I3
GND
Functional block diagram
1997 Data Delay Devices
Doc #97037
12/11/97
DATA DELAY DEVICES, INC.
3 Mt. Prospect Ave. Clifton, NJ 07013
1
MDU13H
APPLICATION NOTES
Delay Devices if your application requires device
testing at a specific input condition.
HIGH FREQUENCY RESPONSE
The MDU13H tolerances are guaranteed for
input pulse widths and periods greater than those
specified in the test conditions. Although the
device will function properly for pulse widths as
small as 50% of the total delay and periods as
small as 100% of the total delay (for a symmetric
input), the delays may deviate from their values
at low frequency. However, for a given input
condition, the deviation will be repeatable from
pulse to pulse. Contact technical support at Data
POWER SUPPLY BYPASSING
The MDU13H relies on a stable power supply to
produce repeatable delays within the stated
tolerances. A 0.1uf capacitor from VEE to GND,
located as close as possible to the VEE pin, is
recommended. A wide VEE trace and a clean
ground plane should be used.
DEVICE SPECIFICATIONS
TABLE 1: ABSOLUTE MAXIMUM RATINGS
PARAMETER
DC Supply Voltage
Input Pin Voltage
Storage Temperature
Lead Temperature
SYMBOL
VEE
VIN
TSTRG
TLEAD
MIN
-7.0
VEE - 0.3
-55
MAX
0.3
0.3
150
300
UNITS
V
V
C
C
NOTES
10 sec
TABLE 2: DC ELECTRICAL CHARACTERISTICS
(0C to 75C)
PARAMETER
High Level Output Voltage
Low Level Output Voltage
High Level Input Voltage
Low Level Input Voltage
High Level Input Current
Low Level Input Current
Doc #97037
12/11/97
SYMBOL
VOH
VOL
VIH
VIL
IIH
IIL
MIN
-1.020
-1.950
TYP
MAX
-0.735
-1.600
-1.070
-1.480
475
0.5
UNITS
V
V
V
V
µA
µA
NOTES
VIH = MAX,50Ω to -2V
VIL = MIN, 50Ω to -2V
VIH = MAX
VIL = MIN
DATA DELAY DEVICES, INC.
Tel: 973-773-2299
Fax: 973-773-9672
http://www.datadelay.com
2
MDU13H
PACKAGE DIMENSIONS
16 15 14 13
.400
TYP.
1
5
6
7
8
.800 TYP.
.020 .320
TYP. MAX.
.150
±.030
.010 TYP.
.100
TYP.
.018 TYP.
.700 TYP.
.300
TYP.
MDU13H-xx (Commercial DIP)
MDU13H-xxM (Military DIP)
.020 TYP.
.040
TYP.
16 15 14 13 12 11 10
.010±.002
9
.882
±.005
.710 .590
±.005 MAX.
1
2
3
4
5
.090
6
7
.007
±.005
8
.100
.700
.880±.020
.280
MAX.
.050
±.010
MDU13H-xxC3 (Commercial SMD)
MDU13H-xxMC3 (Military SMD)
Doc #97037
12/11/97
DATA DELAY DEVICES, INC.
3 Mt. Prospect Ave. Clifton, NJ 07013
3
MDU13H
DELAY LINE AUTOMATED TESTING
TEST CONDITIONS
INPUT:
Ambient Temperature: 25oC ± 3oC
Supply Voltage (Vcc): -5.0V ± 0.1V
Input Pulse:
Standard 10KH ECL
levels
Source Impedance:
50Ω Max.
Rise/Fall Time:
2.0 ns Max. (measured
between 20% and 80%)
Pulse Width:
PWIN = 1.5 x Total Delay
Period:
PERIN = 10 x Total Delay
OUTPUT:
Load:
Cload:
Threshold:
50Ω to -2V
5pf ± 10%
(VOH + VOL) / 2
(Rising & Falling)
NOTE: The above conditions are for test only and do not in any way restrict the operation of the device.
REF
PULSE
GENERATOR
OUT
I1
TRIG
I2
DEVICE UNDER
TEST (DUT)
I3
O1
IN
O2
TRIG
OSCILLOSCOPE
O3
Test Setup
PERIN
PWIN
TRISE
INPUT
SIGNAL
TFALL
VIH
80%
50%
20%
80%
50%
20%
TRISE
OUTPUT
SIGNAL
VIL
TFALL
VOH
50%
50%
VOL
Timing Diagram For Testing
Doc #97037
12/11/97
DATA DELAY DEVICES, INC.
Tel: 973-773-2299
Fax: 973-773-9672
http://www.datadelay.com