TECHNICAL DATASHEET ADP Series Power Adapters 12V 25W/36W/66W ADP 12V Highlights & Features – – – – Energy Star Compliance (Level VI) IT safety approvals 100k Hours MTBF Over-Voltage/Load/Temperature & Short Circuit protections Model Information ADP Series Power Adapters Model Number Input Voltage Range Output Voltage Output Current ADP-25FW BB 90-264Vac 12Vdc 2.1A ADP-36PH BH 90-264Vac 12Vdc 3A ADP-66CR BE 90-264Vac 12Vdc 5.5A Specifications Input Ratings / Characteristics 25W Nominal Input Voltage 115/230Vac 36W 100-240Vac Input Voltage Range 90-264 Vac Nominal Input Frequency 50-60Hz Input Frequency Range 47-63Hz 66W 115/230Vac 1A Max @ 100Vac 600mA @ 240Vac 1A Max at 100Vac input voltage 2A Max at 100Vac input voltage Inrush Current(Cold Start) <50A at 120VAC No Damage at 240Vac <90A at 230Vac Efficiency at nominal input voltage 86% @ 115Vac 84% min, max load and measured at the end of DC cable. 83% Active Mode Efficiency @ 115Vac 86.38% >87.4% 88% Active Mode Efficiency @ 230Vac N/A >84.78 88% <0.1W @115Vac <0.1W @ 115Vac/60Hz and 230Vac/50Hz 0.21w 5milliseconds@100Vac 10milliseconds minimum at 100Vac/50Hz. Input Current No Load Power Consumption Hold Up Time at maximum load >16.7milliseconds@115Vac >20 milliseconds@230Vac TECHNICAL DATASHEET ADP Series Power Adapters 12V 25W/36W/66W Output Ratings / Characteristics 25W 36W Rated Voltage Voltage Range(All Models) Current 66W 12V 11.4 ~ 12.6V 0-2.1A 0-3A 0-5.5A <120mVp-p 450mV pk-pk 120mV pk-pk 2 seconds @ 120Vac 5 seconds @ 100-240Vac Rise Time <20ms 30mS 30ms Max Load Capacitance (microfarads) 1000 470 1000 0%-50%-0% and 50%-100%50% of full nominal load. frequency is 60Hz, 50% duty cycle and the slew rate shall be at 0.02A/us. 0.1~1.5A & 1.5A~3A load at 2.5A/us slew rate , 50% Duty cycle , Frequency be operated 100Hz ~ 10KHz 25W 36W Output Ripple and Noise @20MHz. BW, with 0.1uF ceramic and 47uF Electrolytic Caps connected parallel to load. Turn On delay time Load Transient Response 3 seconds @ 90Vac/60Hz and -0°C to +45°C; OR 10 seconds at -20°C to 0°C. 25 % step load change at 1 A/s.at frequency 500Hz with 50% duty. Environment, EMI and Immunity Operating Temperature Shipping/Storage Temperature Operating Humidity Shipping/Storage Humidity Operating Altitude Lightning Surge Immunity Per IEC-1000-4-5 Electric Fast Transients (EFT) Electrostatic Discharge (ESD) Per IEC-61000-4-2 Dielectric Withstand Voltage (HIPOT) Leakage Current Insulation Resistance Electromagnetic Interference (EMI) MTBF Electrolytic Capacitor Operating Life 66W 0 °C to +40 °C -20 °C to +45 °C -20 °C to +75 °C -30 °C to +80 °C -40 °C to +85 °C Up to 95% 8% to 90% RH (NonCondensing) 10% to 95% RH (NonCondensing) 5% to 95% RH (Non-Condensing) Maximum of 3700 meters (12000 feet) L-N, L-G, N-G, IEEE C62.41.2, 0.5 µs – 100 kHz Ring Wave, 1.2/50 µs - 8/20 µs Combination Wave 6KV, Criterion B 10-95% RH (Non-Condensing) Maximum of 5000 meters -150 to 3000 meters (-500 to 10000 feet) Line –Neutral 1KV/1.2 * 50us Level 3 Criteria A L-N, L-G, N-G Combination Wave 6KV, Criterion B I EC-1000-4-4/1995 (EN EN61000-4-4 +/-1kV on 61000-4-4) Level 3 input power lines; Criterion B requirements Contact discharge:±8KV +/-8kV air discharge; +/-6kV contact Air discharge:±15KV discharge; EN61000-4-4 +/-1kV on input power lines; Criterion B 3KV AC RMS from AC Input to Output <250uA at 264 Vac <100uA at 240Vac/50Hz <250uA at 264 Vac The insulation resistance shall be not less than 4M ohms after application of 500Vdc/10mA for 1 minute. The insulation resistance shall be not less than 30M ohms after application of 500Vdc/10mA for 1 minute. The insulation resistance shall be not less than 10M ohms after application of 500Vdc/10mA for 1 minute. CISPR 22/EN55022 Class B. (a) FCC Class B (b) CISPR 22 Class B (c) VCCI Class B 200,000 hours of continuous 80,000 hours of continuous operation at 25℃ operation at 25℃ 7 years at 115VAC, 40C and 100% rated load 3 years at 115 Vac and 230 Vac, and 25degC 100% rated load CISPR 22 : 1997/EN55022(1998) Class B. 150,000 hours of operation at 90% confidence level at 25degC 5 years at 115 Vac and 230 Vac, and 25degC 100% rated load TECHNICAL DATASHEET ADP Series Power Adapters 12V 25W/36W/66W Protections 25W 36W 66W Overvoltage <150% of nominal output voltage (Recovery mode) Latch Mode Latch Mode Overload / Overcurrent <150% maximum load current (Recovery mode) Auto-Recovery Auto-Recovery Over Temperature Recovery mode Latch Mode Auto-Recovery Short Circuit Recovery mode Auto-Recovery Auto-Recovery Mechanical 25W Color 66W Black Outline Dimensions (L x W x D) 102 * 36.8 * 49 mm AC Inlet Type Fixed 2 pin AC Blades DC Cable Type 36W 89.5.0 * 37.0 * 26.5 mm Socket C6 type 132 * 62 * 34.1 mm Socket C14 Type UL2468 #AWG20 UL1571 #AWG17 UL1571 #AWG14 1500 mm 1800 mm 1500 mm DC Connector - OD 2.1 mm 4.75 mm 2.5 mm DC Connector - ID 5.5 mm 1.7 mm 5.5 mm DC Connector - Length 10.5 mm 12.5 mm 9.5 mm DC Cable Length Mechanical ADP-25FW BB TECHNICAL DATASHEET ADP Series Power Adapters 12V 25W/36W/66W ADP-36PH BH ADP-66CR BE 4 www.DeltaPSU.com (January 2016, Rev. 1.0)