Click on Series name for product info on aimtec.com Series AM6Q-Z 6 Watt | DC-DC Converter FEATURES: RoHS Compliant Wide 2:1 input range High Efficiency up to 86% Continuous short circuit Operating Temperature -40ºC to 85ºC Input / Output Isolation of 500VAC No Tantalum capacitors used inside Over voltage protection Models Single output Model Input Voltage (V) Output Voltage (V) Output Current max (mA) Isolation (VAC) Max Capacitive Load(uF) Efficiency (%) 4.5-9 4.5-9 4.5-9 4.5-9 9-18 9-18 9-18 9-18 18-36 18-36 18-36 18-36 36-75 36-75 36-75 36-75 3.3 5 12 15 3.3 5 12 15 3.3 5 12 15 3.3 5 12 15 1000 1000 500 400 1000 1200 500 400 1200 1200 500 400 1200 1200 500 400 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 1000 1000 500 400 1000 1200 500 400 1200 1200 500 400 1200 1200 500 400 73 76 79 79 76 81 85 85 73 80 84 86 74 80 84 85 Input Voltage (V) Output Voltage (V) Output Current max (mA) Isolation (VAC) Max Capacitive Load(uF) Efficiency (%) 4.5-9 4.5-9 9-18 9-18 18-36 18-36 36-75 36-75 ±12 ±15 ±12 ±15 ±12 ±15 ±12 ±15 ±250 ±200 ±250 ±200 ±250 ±200 ±250 ±200 500 500 500 500 500 500 500 500 ±250 ±200 ±250 ±200 ±250 ±200 ±250 ±200 82 82 88 88 88 88 87 88 AM6Q-0503SZ AM6Q-0505SZ AM6Q-0512SZ AM6Q-0515SZ AM6Q-1203SZ AM6Q-1205SZ AM6Q-1212SZ AM6Q-1215SZ AM6Q-2403SZ AM6Q-2405SZ AM6Q-2412SZ AM6Q-2415SZ AM6Q-4803SZ AM6Q-4805SZ AM6Q-4812SZ AM6Q-4815SZ Models Dual output Model AM6Q-0512DZ AM6Q-0515DZ AM6Q-1212DZ AM6Q-1215DZ AM6Q-2412DZ AM6Q-2415DZ AM6Q-4812DZ AM6Q-4815DZ NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified. Input Specifications Parameters Voltage range Nominal 5 12 24 48 Typical 4.5-9 9-18 18-36 36-75 π (Pi) Network Filter Start up time No Load Input Current Input reflected current www.aimtec.com F 051e R12.C 20 45 20 Tel: +1 514 620 2722 1 of 3 Maximum Units VDC ms mA mA Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AM6Q-Z 6 Watt | DC-DC Converter Isolation Specifications Parameters Conditions Typical 3sec 500 50 500 Tested I/O voltage Resistance Capacitance Maximum Units VAC MOhm pF Output Specifications Parameters Conditions Typical Voltage accuracy Cross Regulation (Dual Output Models) 25% load on one output – 100% load on the other output Over voltage protection Zener Diode Clamp Over Current Protection Short Circuit protection Short circuit restart Line voltage regulation Load voltage regulation Temperature coefficient Ripple & Noise Minimum Load Current FL Maximum % ±5 % 5 12 15 ±12 ±15 185 Continuous Auto Recovery ±0.5 ±1 ±0.02 75 0 LL-HL Load:0-100% unbalanced 20MHz Bandwidth Units ±1 6.2 15 18 ±15 ±18 V % % of Vin % %/oC mV p-p % of Max General Specifications Parameters Switching frequency Operating temperature Storage temperature Maximum case temperature Cooling Humidity Case material Weight Dimensions (L x W x H) MTBF Transient recovery deviation Conditions Typical 100% load Derating above 60ºC 330 Maximum Units 100 KHz o C o C o C -40 to +85 -40 to +125 Free Air Convection 95 Nickel Coated Copper 25 1.75 x 1.10 x 0.28 inches 44.50 x 28.00 x 7.00 mm >1.28Mhrs ( MIL-HDBK -217F, Ground Benign, t=+25°C ) ±3 % RH g % Safety Specifications Parameters Standards Designed to meet IEC/EN 60950-1 Pin Out Specifications Pin Single 1 -V Input 2 +V Input 3 +V Output 4 NP 5 -V Output NP: Not Populated www.aimtec.com F 051e R12.C Dual -V Input +V Input +V Output Common -V Output Tel: +1 514 620 2722 2 of 3 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AM6Q-Z 6 Watt | DC-DC Converter 10.16 (0.40) 10.16 (0.40) 15.24 (0.60) 7.00 (0.28) 2.70 (0.11) 4.40 (0.17) 6.60 (0.26) 28.00 (1.10) 3.84 (0.15) Dimensions Derating NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified. 5. Aimtec may not have conducted destructive testing or chemical analysis on all internal components and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 6. This product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate specific safety and regulatory standards other the ones listed in this datasheet. 7. Warranty is in accordance with Aimtec’s standard Terms of Sale available at www.aimtec.com. www.aimtec.com F 051e R12.C Tel: +1 514 620 2722 3 of 3 Toll free: + 1 888 9 AIMTEC (924 6832) North America only