AIMTEC AM10CW-4803S-FZ 10 watt | dc-dc converter Datasheet

Series AM10CW-FZ
10 Watt | DC-DC Converter
Picture coming soon
FEATURES:








Wide 4:1 Input Voltage Range
High efficiency up to 88%
Remote On/Off
Standard 1”x1” Package
1500 VDC Isolation
Operating Temperature -40ºC to +85ºC
Over Voltage, Over load protection
Output Short Circuit Protection
Models
Single output
Model
Input Voltage
(V)
Output Voltage
(V)
Output Current
max (mA)
Max Capacitive
Load(uF)
Efficiency
(%)
9-36
9-36
9-36
9-36
9-36
18-75
18-75
18-75
18-75
18-75
3.3
5
12
15
24
3.3
5
12
15
24
2200
2000
830
660
410
2200
2000
830
660
410
3300
2200
680
330
100
3300
2200
680
330
100
82
85
88
88
87
80
84
87
87
87
Input Voltage
(V)
Output Voltage
(V)
Output Current
max (mA)
Max Capacitive
Load(uF)
Efficiency
(%)
9-36
9-36
9-36
18-75
18-75
18-75
±5
±12
±15
±5
±12
±15
±1000
±410
±330
±1000
±410
±330
±1000
±470
±220
±1000
±470
±220
85
88
87
84
87
87
AM10CW-2403S-FZ
AM10CW-2405S-FZ
AM10CW-2412S-FZ
AM10CW-2415S-FZ
AM10CW-2424S-FZ
AM10CW-4803S-FZ
AM10CW-4805S-FZ
AM10CW-4812S-FZ
AM10CW-4815S-FZ
AM10CW-4824S-FZ
Models
Dual output
Model
AM10CW-2405D-FZ
AM10CW-2412D-FZ
AM10CW-2415D-FZ
AM10CW-4805D-FZ
AM10CW-4812D-FZ
AM10CW-4815D-FZ
NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at
rated output load unless otherwise specified.
Input Specifications
Parameters
Voltage range
Nominal
Typical
24
48
9-36
18-75
Pi
77
Filter
Start up time
Absolute Maximum Rating
24
48
Peak Input Voltage time
On/Off control
Idle Input Current
Input reflected current
Transient response settling time
Transient response deviation
www.aimtec.com
F 051e R13
At OFF state
50% load step change
di/dt=0.8A/µs
3.3Vou
Maximum
50
100
100
ON –Open or 3.5 to 12V/<0.2mA
OFF –Short to pin 2 (-Vin) or 0 to 0.7V
12
62
550
≤5
≤6
Tel: +1 514 620 2722
1 of 3
Units
VDC
ms
VDC
ms
mA
mA p-p
µs
%
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AM10CW-FZ
10 Watt | DC-DC Converter
Isolation Specifications
Parameters
Conditions
Tested I/O voltage
Resistance
Capacitance
Typical
Maximum
Units
>1000
VDC
MOhm
pF
1500
500VDC
1100
Output Specifications
Parameters
Conditions
Typical
Voltage accuracy
3.3 Vout
5 Vout
12 Vout
15 Vout
24 Vout
Over voltage protection
Short Circuit protection
Short circuit restart
Line voltage regulation
Load voltage regulation (Single)
LL to HL at full load
0% to Full load
Balanced Load
Unbalanced load 25 to 100% load
Load voltage regulation (Dual)
Temperature coefficient
Ripple & Noise
Maximum
±1
3.9
6.2
15
18
27
Continuous
Auto-Recovery
±1
±1
±0.5
±5
%
V
% of Vin
%
%
±0.02
20MHz Bandwidth
Units
80
%/oC
mV p-p
General Specifications
Parameters
Switching frequency
Operating temperature
Storage temperature
Maximum case temperature
Cooling
Humidity
Case material
Weight
Dimensions (L x W x H)
MTBF
Conditions
Typical
100% load
With derating above 60°C
330kHz
Maximum
Units
105
KHz
oC
oC
oC
-40 to +85
-55 to +125
Natural convection
95
Nickel-coated copper
17.4
1 x 1 x 0.4 inches 25.4 x 25.4 x 10.2 mm
>1,580,000 hrs (MIL-HDBK -217F, Ground Benign, t=+25°C)
% RH
g
Pin Out Specifications
Pin
1
2
3
4
5
6
Single
+V input
-V Input
On/Off Control
+V Output
No Pin
-V output
www.aimtec.com
F 051e R13
Dual
+V input
-V Input
On/Off Control
+V Output
Common
-V output
Tel: +1 514 620 2722
2 of 3
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AM10CW-FZ
10 Watt | DC-DC Converter
Dimensions
Bottom View
2.54
(0.10)
Top View
25.40
(1.00)
10.16 2.54
(0.40) (0.10)
10.16
(0.40)
5
4
20.32
(0.80)
25.40
(1.00)
+V Output
6
-V Output
+V
-V
Input Input CTRL
2.54
(0.10)
1
Side View
10.16
(0.40)
2
3
5.08 7.62
(0.20) (0.30)
9.90
(0.39)
Printed Face
2.54
(0.10)
1.00
(0.39)
Notes:
All dimensions are typical in millimeters (inches).
Pin Pitch Tolerance ±0.35 (±0.014)
Case Tolerance ±0.50 (±0.02)
Derating
Free Air Convection
60º C
Output Power (%)
100
80
Safe Operating Area
60
40
30
20
0
- 40
- 20
0
20
40
60
80
85
100
Ambient Temperature º C
NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled
by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the
date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of 25°C, humidity<75%,
nominal input voltage and at rated output load unless otherwise specified. 5.Aimtec may not have conducted destructive testing or chemical analysis on all internal components
and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 6. This
product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate
specific safety and regulatory standards other the ones listed in this datasheet. 7. Warranty is in accordance with Aimtec’s standard Terms of Sale available at www.aimtec.com.
www.aimtec.com
F 051e R13
Tel: +1 514 620 2722
3 of 3
Toll free: + 1 888 9 AIMTEC