Series AM10CW-FZ 10 Watt | DC-DC Converter Picture coming soon FEATURES: Wide 4:1 Input Voltage Range High efficiency up to 88% Remote On/Off Standard 1”x1” Package 1500 VDC Isolation Operating Temperature -40ºC to +85ºC Over Voltage, Over load protection Output Short Circuit Protection Models Single output Model Input Voltage (V) Output Voltage (V) Output Current max (mA) Max Capacitive Load(uF) Efficiency (%) 9-36 9-36 9-36 9-36 9-36 18-75 18-75 18-75 18-75 18-75 3.3 5 12 15 24 3.3 5 12 15 24 2200 2000 830 660 410 2200 2000 830 660 410 3300 2200 680 330 100 3300 2200 680 330 100 82 85 88 88 87 80 84 87 87 87 Input Voltage (V) Output Voltage (V) Output Current max (mA) Max Capacitive Load(uF) Efficiency (%) 9-36 9-36 9-36 18-75 18-75 18-75 ±5 ±12 ±15 ±5 ±12 ±15 ±1000 ±410 ±330 ±1000 ±410 ±330 ±1000 ±470 ±220 ±1000 ±470 ±220 85 88 87 84 87 87 AM10CW-2403S-FZ AM10CW-2405S-FZ AM10CW-2412S-FZ AM10CW-2415S-FZ AM10CW-2424S-FZ AM10CW-4803S-FZ AM10CW-4805S-FZ AM10CW-4812S-FZ AM10CW-4815S-FZ AM10CW-4824S-FZ Models Dual output Model AM10CW-2405D-FZ AM10CW-2412D-FZ AM10CW-2415D-FZ AM10CW-4805D-FZ AM10CW-4812D-FZ AM10CW-4815D-FZ NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified. Input Specifications Parameters Voltage range Nominal Typical 24 48 9-36 18-75 Pi 77 Filter Start up time Absolute Maximum Rating 24 48 Peak Input Voltage time On/Off control Idle Input Current Input reflected current Transient response settling time Transient response deviation www.aimtec.com F 051e R13 At OFF state 50% load step change di/dt=0.8A/µs 3.3Vou Maximum 50 100 100 ON –Open or 3.5 to 12V/<0.2mA OFF –Short to pin 2 (-Vin) or 0 to 0.7V 12 62 550 ≤5 ≤6 Tel: +1 514 620 2722 1 of 3 Units VDC ms VDC ms mA mA p-p µs % Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AM10CW-FZ 10 Watt | DC-DC Converter Isolation Specifications Parameters Conditions Tested I/O voltage Resistance Capacitance Typical Maximum Units >1000 VDC MOhm pF 1500 500VDC 1100 Output Specifications Parameters Conditions Typical Voltage accuracy 3.3 Vout 5 Vout 12 Vout 15 Vout 24 Vout Over voltage protection Short Circuit protection Short circuit restart Line voltage regulation Load voltage regulation (Single) LL to HL at full load 0% to Full load Balanced Load Unbalanced load 25 to 100% load Load voltage regulation (Dual) Temperature coefficient Ripple & Noise Maximum ±1 3.9 6.2 15 18 27 Continuous Auto-Recovery ±1 ±1 ±0.5 ±5 % V % of Vin % % ±0.02 20MHz Bandwidth Units 80 %/oC mV p-p General Specifications Parameters Switching frequency Operating temperature Storage temperature Maximum case temperature Cooling Humidity Case material Weight Dimensions (L x W x H) MTBF Conditions Typical 100% load With derating above 60°C 330kHz Maximum Units 105 KHz oC oC oC -40 to +85 -55 to +125 Natural convection 95 Nickel-coated copper 17.4 1 x 1 x 0.4 inches 25.4 x 25.4 x 10.2 mm >1,580,000 hrs (MIL-HDBK -217F, Ground Benign, t=+25°C) % RH g Pin Out Specifications Pin 1 2 3 4 5 6 Single +V input -V Input On/Off Control +V Output No Pin -V output www.aimtec.com F 051e R13 Dual +V input -V Input On/Off Control +V Output Common -V output Tel: +1 514 620 2722 2 of 3 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AM10CW-FZ 10 Watt | DC-DC Converter Dimensions Bottom View 2.54 (0.10) Top View 25.40 (1.00) 10.16 2.54 (0.40) (0.10) 10.16 (0.40) 5 4 20.32 (0.80) 25.40 (1.00) +V Output 6 -V Output +V -V Input Input CTRL 2.54 (0.10) 1 Side View 10.16 (0.40) 2 3 5.08 7.62 (0.20) (0.30) 9.90 (0.39) Printed Face 2.54 (0.10) 1.00 (0.39) Notes: All dimensions are typical in millimeters (inches). Pin Pitch Tolerance ±0.35 (±0.014) Case Tolerance ±0.50 (±0.02) Derating Free Air Convection 60º C Output Power (%) 100 80 Safe Operating Area 60 40 30 20 0 - 40 - 20 0 20 40 60 80 85 100 Ambient Temperature º C NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified. 5.Aimtec may not have conducted destructive testing or chemical analysis on all internal components and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 6. This product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate specific safety and regulatory standards other the ones listed in this datasheet. 7. Warranty is in accordance with Aimtec’s standard Terms of Sale available at www.aimtec.com. www.aimtec.com F 051e R13 Tel: +1 514 620 2722 3 of 3 Toll free: + 1 888 9 AIMTEC (924 6832) North America only