Artesyn NPS64-M Total power: 60 watt Datasheet

POWER
NPS60-M Series
60 Watts
Data Sheet
Total Power: 60 Watts
Input Voltage: 90 - 264 VAC
127 - 300 VDC
# of Outputs: Single
SPECIAL FEATURES
ƒƒ Medical and ITE safety approvals
ƒƒ Universal input
ƒƒ Less than 1U high
ƒƒ 2” x 4” footprint
ƒƒ Remote sense
ƒƒ Overload and short circuit protection
ƒƒ Adjustable output voltage
ƒƒ High efficiency
ƒƒ High MTBF
ƒƒ Built-in EMI filter (CISPR 22 Class B)
ƒƒ International Efficiency Level V,
Energy Star 2.0 & CeC compliant
(except NPS62-M)
ƒƒ Less than 300 mW no-load power
consumption (less than 500 mW for
NPS62-M)
ƒƒ 0 °C to +80 °C operation
ƒƒ Input power < 74 watts
ƒƒ Complies with EN61000-3-2
ƒƒ UL Class I approved
ƒƒ Class II approved (with Class A EMI)
ƒƒ LPX100 enclosure kit available
ƒƒ Dual AC fuses
ƒƒ RoHS compliant
SAFETY
ƒƒ TUV:
ƒƒ UL:
ƒƒ CSA:
ƒƒ NEMKO:
ƒƒ CB:
ƒƒ CE:
ƒƒ CCC:
60950, 60601-1
60950, 60601-1
60950, 60601-1
60950, 60601-1
Certificate and report
Mark (LVD)
Mark
Electrical Specifications
Input
Input ra­nge
90 - 264 Vac (wide range) 127-300 Vdc
Frequency
47 - 63 Hz
Inrush current
< 50 A peak @ 230 Vac, cold start @ 25° C
Input power
< 74 Watts
Efficiency
87% average (as per Energy Star 2.0 standard) (NPS62-M, 80%)
EMI/RFI
FCC Class B conducted; CISPR 22 Class B conducted; EN55022
Class B conducted, VDE0878PT3 Class B conducted
Safety ground
leakage current
275 µA @ 50/60 Hz; 264 Vac input
Output
Maximum power
60 W for convection
Adjustment range
± 20% minimum
Hold-up time
13/75 ms 115/230 Vac input line
Overload protection
Short circuit protection on all outputs. Case overload protected @
110-160% of normal rating
Overvoltage protection
30-50% above nominal output
Remote sense
Compensated for 0.5 V lead drop max. Will operate without remote
sense connected. Reverse connection protected.
NPS60-M Series Data Sheet
Environmental Specifications
0 ° to 50 °C ambient derate each output at 2.5% per degree from 50 ° to 80 °C. -20 °C start up
Operating temperature
Storage temperature
-45 °C to +85 °C
Electromagnetic susceptibility
Designed to meet EN61000-4; -2, -3, -4, -5, -6, -8, -11 Level 3
Humidity
Operating; non-condensing 10% to 90% RH
Vibration
IEC68-2-6 to the levels of IEC721-3-2
MTBF demonstrated
> 550,000 hours at full load and 25 °C ambient conditions
Mechanical Drawing
BARCODE
SERIAL LABEL
M1
GND TAB
(CN1)
SK2
SK1
1.72"
(43.8)
PIN 1
PIN 1
PIN 6
MODEL LABEL
6 PIN OUTPUT
CONNECTOR
(SK2)
1.01"
(26)
ROHS LABEL
M2
0.197” (5.0) MINIMUM STANDOFF HEIGHT
NPS62-M 1.28” (32.6)
PIN 3
INPUT
CONNECTOR
(SK1)
0.16” (4.0) MOUNTING HOLE
(4 PLACES)
2.00"
(50.8)
VR1
OUTPUT VOLTAGE
ADJUST POT
4.00"
(101.6) 3.73"
(94.6)
0.87"
(22)
NPS62-M 1.14” (29)
NPS60-M Series Data Sheet
Ordering Information
Model Number
Output Voltage
Minimum
Load
Maximum Load with
Convection Cooling
Peak Load1
Regulation2
Ripple
P/P (PARD)3
5V
0A
11 A
13 A
± 2%
50 mV
NPS62-M
NPS63-M
12 V
0A
5A
5.5 A
± 2%
120 mV
NPS63-M-0064
12 V
0A
5A
5.5 A
± 2%
120 mV
NPS64-M
15 V
0A
4A
4.4 A
± 2%
150 mV
NPS65-M
24 V
0A
2.5 A
2.75 A
± 2%
240 mV
1. Peak current lasting <15 seconds with a maximum 10% duty cycle.
2. At 25 °C including initial tolerance, line voltage, load currents and output voltages adjusted to factory settings.
3. Peak-to-peak with 20 MHz bandwidth and 10 µF (tantalum capacitor) in parallel with a 0.1 µF capacitor at rated line voltage and load ranges.
4. Compliant to Level VI efficiency.
5. This product is a Component Power Supply and is only for inclusion by professional installers within other equipment and must not be operated as a standalone product. EMC
compliance to appropriate standards must be verified at the system level. This product is for sale to OEMs and System Integrators, including through Distribution Channels. It is
not intended for sale to End Users.
Pin Assignments
Connector
SK1-1
NPS62-M
NPS63-M
NPS65-M
Line
Line
Line
SK1-3
Neutral
Neutral
Neutral
CN1
Ground
Ground
Ground
SK2-1
+5 V
+12 V
+24 V
SK2-2
+5 V
+12 V
+24 V
SK2-3
Common
Common
Common
SK2-4
Common
Common
Common
SK2-5
-Sense
-Sense
-Sense
SK2-6
+Sense
+Sense
+Sense
Mating­ Connectors
AC Input
Molex 09-50-8031 (USA)
09-93-0300 (UK)
PINS: 08-52-0113
DC Outputs
Molex 09-50-8061 (USA)
09-93-0600 (UK)
PINS: 08-52-0113
Artesyn Embedded Technologies Connector Kit #70-841-006 includes
all of the above.
Notes:
1. Specifications subject to change without notice.
2. All dimensions in inches (mm), tolerance is ±0.02”­­(±0.5 mm)
3. Mounting holes M1 and M2 should be grounded for EMI purposes.
4. Mounting hole M1 is safety ground connection.
5. Specifications are for convection rating at factory settings at 115 Vac
input, 25 °C unless otherwise stated.
6. For DC input an external DC safety rated fuse must be used
7. Warranty: 2 year
8. Weight: 0.26 lbs/0.118 kg
WORLDWIDE OFFICES
Americas
Europe (UK)
Asia (HK)
2900 S.Diablo Way
Tempe, AZ 85282
USA
+1 888 412 7832
Waterfront Business Park
Merry Hill, Dudley
West Midlands, DY5 1LX
United Kingdom
+44 (0) 1384 842 211
14/F, Lu Plaza
2 Wing Yip Street
Kwun Tong, Kowloon
Hong Kong
+852 2176 3333
Artesyn Embedded Technologies, Artesyn and the Artesyn Embedded Technologies logo are trademarks and
service marks of Artesyn Embedded Technologies, Inc. All other names and logos referred to are trade names,
trademarks, or registered trademarks of their respective owners. © 2016 Artesyn Embedded Technologies, Inc.
All rights reserved. For full legal terms and conditions, please visit www.artesyn.com/legal.
www.artesyn.com
For more information: www.artesyn.com/power
For support: [email protected]
NPS60-M DS 21Mar2016