NAIS JV1PF-S-18V Flat type power relay Datasheet

FLAT TYPE POWER RELAY
22
.866
JV-RELAYS
FEATURES
16
.630
• Flat type: 16 mm (length) × 22 mm (width) × 10.9 mm (height)
(.630×.866×.429 inch)
• High capacity type (16A) available
• High sensitivity type (100 mW: 1 Form A) available
• TÜV also approved
10.9
.429
mm inch
SPECIFICATIONS
Contact
Standard type
Arrangement
Initial contact resistance, max.
(By voltage drop 6 V DC 1 A)
Contact material
Nominal switching
capacity
Rating
(resistive)
1 Form A
1 Form C
Characteristics
High capacity
High
type
sensitivity type
1 Form A
1 Form A
Max. operating speed
Initial insulation resistance*1
Between open
Initial
contacts
breakdown
Between convoltage*2 tacts and coil
50 mΩ
Max. switching power
Max. switching voltage
Max. switching current
Silver alloy
10 A 125 V AC (N.O.)
10 A 125 V AC
16 A 125 V AC 10 A 125 V AC
6 A 125 V AC (N.C.)
1,250 VA (N.O.)
1,250 VA
2,000 VA
1,250 V
750 VA (N.C.)
125 V AC
10 A (N.O.)
10 A
16 A
10 A
6 A (N.C.)
Expected life (min. ope.)
Mechanical at (180 cpm)
Electrical at resistive Sealed type
(at 20 cpm)
Flux-resistant
(at rated load)
type
Operate time*3
(at nominal voltage)
Release time (without diode)*3
(at nominal voltage)
107
Coil
105
105
3×104
5×104
3×105
105
105
105
1 Form A type
200 mW (up to 48 V coil type)
Nominal Standard type
600 mW (100 V coil type)
operating
High capacity type
power
High sensitivity type
100 mW
20 cpm
Min. 100 MΩ
(at 500 V DC)
1,000 Vrms
for 1 min.
1,500 Vrms
for 1 min.
Approx. 10 ms
Approx. 5 ms
(100 V DC coil type)
Approx. 4 ms
Max. 65°C with nominal
coil voltage across
coil and at nominal
switching capacity
Temperature rise
(at 50°C)
Functional*4
Shock
resistance Destructive*5
Min. 98 m/s2 {10 G}
Min. 980 m/s2
{100 G}
10 to 55 Hz
Functional*6 at double amplitude
of 1.0 mm
Vibration
resistance
10 to 55 Hz
Destructive
at double amplitude
of 1.6 mm
Conditions for opera- Ambient –40°C to +70°C*8
tion, transport and temp.
–40°F to +158°F
storage*7
(Not freezing and
Humidity
5 to 85%R.H.
condensing at low
temperature)
1 Form C type
400 mW (up to 48 V coil type)
600 mW (100 V coil type)
—
—
Remarks
* Specifications will vary with foreign standards certification ratings.
*1 Measurement at same location as "Initial breakdown voltage"section
*2 Detection current: 10mA
*3 Excluding contact bounce time
*4 Half-wave pulse of sine wave: 11ms, detection time: 10µs
*5 Half-wave pulse of sine wave: 6ms
*6 Detection time: 10µs
*7 Refer to 5. Conditions for operation, transport and storage mentioned in AMBIENT ENVIRONMENT (Page 24).
*8 100V type: –40 to + 60°C –40 to + 140°F
Unit weight
Approx. 8 g .282 oz
TYPICAL APPLICATIONS
1. Home appliances: Air conditioner, heater, etc.
2. Automotive: Power supply for car stereo and air conditioner
ORDERING INFORMATION
Ex. JV
1a
P
F
Contact arrangement
Rating
Protective construction
1: 1 Form C
1a: 1 Form A
Nil: Standard type
P: High capacity type*
Nil: Sealed type
F: Flux-resistant type
S
12V
Sensitivity
Nil: Standard type
(1 Form A: 200 mW, 1Form C: 400 mW
100 V DC coil type: 600 mW)
S: High sensitivity type*
(1 Form A: 100 mW)
Notes: 1. Standard packing: Carton: 50 pcs.; Case: 1,000 pcs.
2. Coil voltage DC 48, 100 V types are not available for high sensitivity type.
UL/CSA, TÜV approved type is standard.
Coil voltage (DC)
5, 6, 9, 12, 18,
24, 48, 100V
* Only for 1 Form A type
87
JV
TYPES
Contact arrangement
Coil voltage, V DC
5
6
9
12
18
24
48
100
5
6
9
12
18
24
48
100
5
6
9
12
18
24
5
6
9
12
18
24
48
100
1 Form A
Standard type
1 Form A
High capacity type
1 Form A
High sensitivity type
1 Form C
Sealed type
JV1a-5V
JV1a-6V
JV1a-9V
JV1a-12V
JV1a-18V
JV1a-24V
JV1a-48V
JV1a-100V
JV1aP-5V
JV1aP-6V
JV1aP-9V
JV1aP-12V
JV1aP-18V
JV1aP-24V
JV1aP-48V
JV1aP-100V
JV1aS-5V
JV1aS-6V
JV1aS-9V
JV1aS-12V
JV1aS-18V
JV1aS-24V
JV1-5V
JV1-6V
JV1-9V
JV1-12V
JV1-18V
JV1-24V
JV1-48V
JV1-100V
Part No.
Flux-resistant type
JV1aF-5V
JV1aF-6V
JV1aF-9V
JV1aF-12V
JV1aF-18V
JV1aF-24V
JV1aF-48V
JV1aF-100V
JV1aPF-5V
JV1aPF-6V
JV1aPF-9V
JV1aPF-12V
JV1aPF-18V
JV1aPF-24V
JV1aPF-48V
JV1aPF-100V
JV1aFS-5V
JV1aFS-6V
JV1aFS-9V
JV1aFS-12V
JV1aFS-18V
JV1aFS-24V
JV1F-5V
JV1F-6V
JV1F-9V
JV1F-12V
JV1F-18V
JV1F-24V
JV1F-48V
JV1F-100V
COIL DATA (at 20°C 68°F)
Part No.
1 Form A
(Standard type &
High capacity
type)
1 Form A
(High sensitivity
type)
1 Form C
88
Nominal voltage,
V DC
Pick-up voltage,
V DC (max.)
5
6
9
12
18
24
48
100
5
6
9
12
18
24
5
6
9
12
18
24
48
100
4.0
4.8
7.2
9.6
14.4
19.2
38.4
48
4.0
4.8
7.2
9.6
14.4
19.2
4.0
4.8
7.2
9.6
14.4
19.2
38.4
70
Drop-out
voltage,
V DC (min.)
0.25
0.3
0.45
0.6
0.9
1.2
2.4
3
0.25
0.3
0.45
0.6
0.9
1.2
0.25
0.3
0.45
0.6
0.9
1.2
2.4
5
Coil resistance,
Ω (±10%)
125
180
405
720
1,620
2,880
11,520
16,600
250
360
810
1,440
3,240
5,760
62.5
90
202.5
360
810
1,440
5,760
16,600
Nominal operating current, mA
(±10%)
40
33.3
22.2
16.7
11.1
8.3
4.2
6
20
16.7
11.1
8.3
5.6
4.2
80
66.7
44.4
33.3
22.2
16.7
8.3
6
Nominal
operating power,
mW
200
200
200
200
200
200
200
600
100
100
100
100
100
100
400
400
400
400
400
400
400
600
Max. allowable
voltage,
V DC
7.5
9
13.5
18
27
36
72
110
9
10.8
16.2
21.6
32.4
43.2
6.5
7.8
11.7
15.6
23.4
31.2
62.4
110
JV
DIMENSIONS
mm inch
1 Form A type
1 Form C type
22
.866
16
.630
22
.866
16
.630
10.5
0.4 .413
.016
10.5
0.4 .413
.016
4
.157
4
.157
PC board pattern (Copper-side view)
17.78
.700
2
17.78
.700
1
PC board pattern (Copper-side view)
17.78
.700
2-0.9 dia.
2-.035 dia.
2
12.7
.500
COM
3
NO
2-0.9 dia.
2-.035 dia.
12.7
.500
NC
5
4
17.78
.700
1
COM
3
12.7
.500
10.16
.400
2-1.3 dia.
2-.051 dia.
Dimension :
Max. 1mm .039 inch
1 to 5mm .039 to .197 inch
Min. 5mm .197 inch
General tolerance
±0.2 ±.008
±0.3 ±.012
±0.4 ±.016
NO
NC
5
4
10.16
.400
10.16
.400
12.7
.500
7.62
.300
3-1.3 dia.
3-.051 dia.
Dimension :
Max. 1mm .039 inch
1 to 5mm .039 to .197 inch
Min. 5mm .197 inch
Tolerance: ±0.1 ±.004
10.16
.400
General tolerance
±0.2 ±.008
±0.3 ±.012
±0.4 ±.016
7.62
.300
Tolerance: ±0.1 ±.004
REFERENCE DATA
1.-(1) Maximum value for switching capacity
(1 Form A type)
1.-(2) Maximum value for switching capacity
(1 Form C type)
100
Contact current, A
High capacity type, AC resistive load
16
10
Standard type, AC resistive load
AC resistive load (NO side)
10
1
1
18
Operate/release time, ms
100
Contact current, A
2.-(1) Operate/release time
(Standard 1 Form A type)
16
14
12
Operate time
10
8
6
4
Max.
–
x
Min.
Max.
–
x
Min.
Release time
2
100
10
1,000
100
16
14
12
10
Operate time
6
Release time
2
0
80
100 120
80
100
120
140
160
180
3.-(1) Coil temperature rise (1 Form A type)
Measured portion: Inside the coil
18
4
0
Coil applied voltage, %V
2.-(3) Operate/release time (1 Form C type)
Operate/release time, ms
Operate/release time, ms
2.-(2) Operate/release time
(High capacity 1 Form A type)
8
1,000
Contact voltage, V
Contact voltage, V
140 160
Max.
–
x
Min.
Max.
–
x
Min.
180
10
8
Operate time
6
Release time
2
0
80
100
80
120
140
60
10 A at
60°C 140°F
(Standad type)
40
20
0
160
80
100
Coil applied voltage, %V
3.-(2) Coil temperature rise
(1 Form C type)
3.-(3) Coil temperature rise
(High sensitivity type)
Measured portion: Inside the coil
Measured portion: Inside the coil
10 A at
15°C 59°F
(Standad type)
15 A at 60°C 140°F
(High capacity type)
Max.
–
x
Min.
Max.
–
x
Min.
4
Coil applied voltage, %V
15 A at 26°C 79°F
(High capacity type)
Temperature rise, °C
10
120
140
160
180
Coil applied voltage, %V
4. Life curve
Operation frequency: 20 times/min.
(ON/OFF = 1.5s:1.5s)
Ambient temperature: Room temperature
100
60
10 A
at 25°C 77°F
60
40
125V AC resistive load
40
Life, ×104
80
Temperature rise, °C
Temperature rise, °C
Standard 200 mW type
10
High sensitivity 100 mW type
20
20
0
80
100
120
140
160
180
Coil applied voltage, %V
0
0 100
120
140
160
180
200
Coil applied voltage, %V
1
4
6
8
10
12
14
16
18
Contact current, A
89
JV
Contact current: 10 A
Contact current: 0 A, 10 A, 13 A, 15 A
Contact current: 10 A
Allowable ambient temperatures
against % coil voltage
(max. inside the coil temperature
set as 115°C 239°F)
300
200
Pick-up voltage with
a hot-start condition
of 100%V on the coil
0
300
13
200
Pick-up voltage
0
20
40
60
80
100
0
120
A
A
Allowable ambient
temperature against
A
% coil voltages
(max. inside the coil
temperature set as
13 A 15 A
115°C 239°F)
Pick-up voltage with
a hot-start condition
of 100%V on the coil
10 A Pick-up voltage
0A
20
40
60 80 100 120
15
100
100
A
10
Coil applied voltage, %V
5.-(3) Ambient temperature characteristics
(1 Form C type)
Coil applied voltage, %V
5.-(2) Ambient temperature characteristics
(High capacity 15 A type, 1 Form A)
Coil applied voltage, %V
5.-(1) Ambient temperature characteristics
(Standard 10 A type, 1 Form A)
200
Pick-up voltage
100
0
Ambient temperature, °C
Ambient temperature, °C
Allowable ambient temperatures
against % coil voltages
(max. inside the coil temperature
set as 115°C 239°F)
20
40
60
80
Ambient temperature, °C
5.-(4) Ambient temperature characteristics
(High sensitivity type)
Contact current: 10 A
Coil applied voltage, %V
300
High sensitivity
100 mW type
Standard
200 mW type
200
Allowable ambient
temperature
against % coil
voltages (max.
inside the coil temperature
set as 115°C 239°F)
100
0
0
20
40
60
80
100
120
Temperature rise, °C
Types dedicated to a wider variety of automotive applications are available, upon receipt of order, with the following specifications:
SPECIFICATIONS
Contact
Characteristics
Arrangement
Initial contact resistance, max.
(By voltage drop 6 V DC 1 A)
Contact material
Nominal switching capacity
Rating
(resistive Max. switching power
load)
Max. switching voltage
Max. switching current
Mechanical (at 300 cpm)
Expected
Electrical
life (min.
(DC 12 V motor, 6 A steady current,
ope.)
20 A lock current)(at rated load)
1 Form C
100 mΩ
Silver alloy
10 A 125 V AC
6A 30 V DC
1,250 V AC
180 W
125 V (AC) 30 V (DC)
10 A (AC) 6 A (DC)
5×106
Functional
4×104
Vibration resistance
Destructive
Coil
Nominal voltage, V DC
Nominal operating power
Pick-up voltage, V DC (max.)
Drop-out voltage; V DC (min.)
Max. allowable voltage
Max. operating speed
Initial insulation resistance
Initial break Between open contacts
down voltage Between contacts and coil
Operate time (at nominal voltage)
Release time (at nominal voltage)
Temperature rise (max.)
(at nominal voltage)(at 50°C)
Functional
Shock resistance
Destructive
5, 6, 9, 12, 18, 24
450 mW
70% of nominal voltage
5% of nominal voltage
150% of nominal voltage
Conditions for operation,
Ambient
transport and storage
temp.
(Not freezing and condensHumidity
ing at low temperature)
Unit weight
20 cpm
Min. 100 MΩ (at 500 V DC)
750 Vrms for 1 min.
1,500 Vrms for 1 min.
Approx. 5 ms
Approx. 4 ms
65°C with nominal coil voltage and at
maximum allowable contact current
Min. 196 m/s2 {20 G}
Min. 980 m/s2 {100 G}
10 to 55 Hz at double amplitude of
1.6 mm
10 to 55 Hz at double amplitude of
2 mm
–40°C to +70°C
–40°F to +158°F
5 to 85%R.H.
Approx. 8 g .282 oz
For Cautions for Use, see Relay Technical Information (Page 11 to 39).
90