API M57T Double balanced mixer Datasheet

Double Balanced Mixer
Model M57T
RF Band
RF 10 to 1500 MHz
Electrical Specifications
:
(1)
Conditions
Parameter
SSB Conversion loss:(2)
Isolation
LO to RF:
RF (MHz) LO (MHz)
10-1000
10-1000
10-1500
10-1500
Desensitization Point:
Input Third Order
Intercept Point:
LO Power: (3)
Min
35
30
30
25
10-500
500-1500
10-500
500-1500
LO to IF:
Input 1 dB
Compression Point:
Specifications
IF (MHz)
DC-500
DC-1000
Typical
7.5 dB
8.5 dB
Max
8.0 dB
9.5 dB
dB
dB
dB
dB
10-1500
10-1500
DC-1000
+17 dBm
10-1500
10-1500
DC-1000
+15 dBm
10-1500
10-1500
DC-1000
+27 dBm
10-1500
10-1500
DC-1000
+23 dBm
Notes:
1. Specifications are guaranteed when tested as a downconverter in a 50 Ohm system at +25˚C with the nominal LO
power. Specifications indicated as typical are not guaranteed.
2. SSB Noise figure is nominally within ±0.5 dB of the SSB conversion loss for IF frequencies greater than 10 MHz.
3. Usable LO drives are up to 2 dB below and 3 dB above nominal.
Typical Performance at 25˚C
M57T
Outline: TO-8
SPECTRUM
All dimensions are in inches and [mm].
Spectrum Microwave · 2144 Franklin Drive N.E. · Palm Bay, FL 32905 · PH (888) 553-7531 · Fax (888) 553-7532
www.SpectrumMicrowave.com Spectrum Microwave · 2707 Black Lake Place · Philadelphia, PA 19154 · PH (215) 464-4000 · Fax (215) 464-4001