FF-1319-13H This filter has been designed to operate with the Vicor "VI- HAMD / BAMD harmonic attenuator modules" to meet EN55022, class B. This model is identical to the (-13) except for the form factor of the enclosure. Order P/N: LINE LOAD BLUE BLUE BROWN BROWN FF-1319-13H GRN / YEL Operating Voltage = _________________DC to 250 Vac Operating Current (Max) = ____________________ 13A Operating Frequency = ___________________50/60 Hz INSERTION LOSS vs. FREQUENCY Temp. Range (Storage) = ______________-40 to 85°C Temp. Range (Operating) (-13C) @ 13.0 A = -40 to 65ºC Diel. Withstanding Voltage (Ph - Case) = ____ 1500 Vac Diel. Withstanding Voltage (Ph - Ph) = ______1500 Vdc Leakage Current @ 250 Vac, 60 HZ = _____2.5 mA Max Discharge Voltage after 60 sec = ___________34 V Max Calculated MTBF = __________________2,278,891 Hrs USA JMK Inc 15 Caldwell Dr. Amherst, NH 03031 PH: 603 886-4100 FX: 603 886-4115 email: [email protected] PH: 44-(0) 7785310729 Fax: 44-(0) 141 589 1884 EUR JMK Inc Glasgow G13 1DN Scotland UK