AD AD9925 Ccd signal processor with vertical driver and precision timing generator Datasheet

CCD Signal Processor with Vertical Driver
and Precision Timing ™ Generator
AD9925
FEATURES
GENERAL DESCRIPTION
Integrated 10-channel V-driver
Register-compatible with the AD9991 and AD9995
3-field (6-phase) vertical clock support
2 additional vertical outputs for advanced CCDs
Complete on-chip timing generator
Precision Timing core with <600 ps resolution
Correlated double sampler (CDS)
6 dB to 42 dB 10-bit variable gain amplifier (VGA)
12-bit 36 MHz ADC
Black level clamp with variable level control
On-chip 3 V horizontal and RG drivers
2-phase and 4-phase H-clock modes
Electronic and mechanical shutter support
On-chip driver for external crystal
On-chip sync generator with external sync input
8 mm × 8 mm CSPBGA package with 0.65 mm pitch
The AD9925 is a complete 36 MHz front end solution for digital still camera and other CCD imaging applications. Based on
the AD9995 product, the AD9925 includes the analog front end
and a fully programmable timing generator (AFETG), combined
with a 10-channel vertical driver (V-driver). A Precision Timing
core allows adjustment of high speed clocks with approximately
600 ps resolution at 36 MHz operation.
The on-chip V-driver supports up to 10 channels for use with
3-field (6-phase) CCDs. Two additional vertical outputs can be
used with CCDs that contain advanced video readout modes.
Voltage levels of up to +15 V and −8 V are supported.
The analog front end includes black level clamping, CDS, VGA,
and a 12-bit ADC. The timing generator and V-driver provide
all the necessary CCD clocks: RG, H-clocks, vertical clocks,
sensor gate pulses, substrate clock, and substrate bias control.
The internal registers are programmed using a 3-wire serial
interface.
APPLICATIONS
Digital still cameras
Digital video camcorders
CCD camera modules
Packaged in an 8 mm × 8 mm CSPBGA, the AD9925 is specified over an operating temperature range of −25°C to +85°C.
FUNCTIONAL BLOCK DIAGRAM
REFT REFB
AD9925
0dB, –2dB, –4dB
CDS
CCDIN
6dB TO 42dB
VREF
12
12-BIT
ADC
VGA
DOUT
CLAMP
DCLK
INTERNAL CLOCKS
RG
V1, V2
V3A, V3B
V4, V6
V5A, V5B
V7, V8
PRECISION
TIMING
GENERATOR
HORIZONTAL
DRIVERS
MSHUT
STROBE
XV1 TO XV8
8
10
V-DRIVER
XSG1 TO XSG6
6
SL
INTERNAL
REGISTERS
VERTICAL
TIMING
CONTROL
SDI
SCK
SYNC
GENERATOR
SUBCK
RSTB
SUBCK
VSUB
HD
VD SYNC
CLI CLO
04637-0-001
H1 TO H4
4
Figure 1.
Rev. A
Information furnished by Analog Devices is believed to be accurate and reliable.
However, no responsibility is assumed by Analog Devices for its use, nor for any
infringements of patents or other rights of third parties that may result from its use.
Specifications subject to change without notice. No license is granted by implication
or otherwise under any patent or patent rights of Analog Devices. Trademarks and
registered trademarks are the property of their respective owners.
One Technology Way, P.O. Box 9106, Norwood, MA 02062-9106, U.S.A.
Tel: 781.329.4700
www.analog.com
Fax: 781.326.8703
© 2004 Analog Devices, Inc. All rights reserved.
AD9925
TABLE OF CONTENTS
Specifications..................................................................................... 3
Vertical Timing Generation...................................................... 22
Digital Specifications........................................................................ 4
Vertical Timing Example........................................................... 34
Vertical Driver Specifications ......................................................... 5
Shutter Timing Control ............................................................. 36
Analog Specifications....................................................................... 6
Example of Exposure and Readout of Interlaced Frame........... 41
Timing Specifications....................................................................... 7
FG_TRIG Operation.................................................................. 43
Absolute Maximum Ratings............................................................ 8
Analog Front End Description and Operation ...................... 45
Package Thermal Characteristics ............................................... 8
Vertical Driver Signal Configuration ...................................... 47
ESD Caution.................................................................................. 8
Power-Up and Synchronization ............................................... 51
Pin Configuration and Function Descriptions............................. 9
Standby Mode Operation .......................................................... 55
Terminology .................................................................................... 11
Circuit Layout Information....................................................... 57
Equivalent Circuits ......................................................................... 12
Serial Interface Timing .............................................................. 59
Typical Performance Characteristics ........................................... 13
Complete Listing for Register Bank 1.......................................... 62
System Overview ........................................................................ 14
Complete Listing for Register Bank 2.......................................... 66
Precision Timing High Speed Timing Generation.................. 15
Complete Listing for Register Bank 3.......................................... 87
Horizontal Clamping and Blanking......................................... 18
Outline Dimensions ....................................................................... 94
Horizontal Timing Sequence Example.................................... 21
Ordering Guide .......................................................................... 94
REVISION HISTORY
10/04—Data Sheet Changed from Rev. 0 to Rev. A
Changes to Specifications ........................................................................................3
Added Stress Disclaimer..........................................................................................8
Changes to Figure 12................................................................................................13
Changes to Figure 22................................................................................................18
Changes to Figure 55................................................................................................45
Change to DC Restore Section ...............................................................................45
Change to Correlated Double Sampler Section....................................................45
Change to ADC Section...........................................................................................46
Change to Digital Data Outputs Section ...............................................................46
Added Paragraph to Digital Data Outputs Section..............................................46
Changes to Table 34..................................................................................................55
Change to Circuit Layout Information Section....................................................57
Changes to Register Address Bank 1, Bank 2, and Bank 3 Section ...................60
Changes to Table 40..................................................................................................63
Change to Table 46 ...................................................................................................65
Changes to Tables 47–56, 58–73.............................................................................66
4/04—Revision 0: Initial Version
Rev. A | Page 2 of 96
AD9925
SPECIFICATIONS
Table 1.
Parameter
TEMPERATURE RANGE
Operating
Storage
POWER SUPPLY VOLTAGES
AVDD (AFE Analog Supply)
TCVDD (Timing Core Analog Supply)
RGVDD (RG Driver)
HVDD (H1 to H4 Drivers)
DRVDD (Data Output Drivers)
DVDD (Digital)
V-DRIVER SUPPLY VOLTAGES
VDVDD (V-Driver Input Logic Supply)
VH1, VH2 (V-Driver High Supply for 3-Level Outputs)
VM1, VM2 (V-Driver Mid Supply for 3-Level and 2-Level Outputs)
VL1, VL2 (V-Driver Low Supply for 3-Level and 2-Level Outputs)
POWER DISSIPATION—AFETG Section Only (see Figure 9 for Power Curves)
36 MHz, 3.0 V Supply, 100 pF Load on Each H1 to H4 Output, 20 pF RG Load
Standby 1 Mode
Standby 2 Mode
Standby 3 Mode
Power from HVDD Only1
Power from RGVDD Only
Power from AVDD Only
Power from TCVDD Only
Power from DVDD Only
Power from DRVDD Only
POWER DISSIPATION—V-Driver Section Only (VDVDD, VH, VL)
Normal Operation (VH = 15.0 V, VL = −7.5 V)2
Standby 1 Mode2
Standby 2 Mode2
Standby 3 Mode2
MAXIMUM CLOCK RATE (CLI)
1
2
Min
Typ
–25
–65
Max
Unit
+85
+150
°C
°C
2.7
2.7
2.7
2.7
2.7
2.7
3.0
3.0
3.0
3.0
3.0
3.0
3.6
3.6
3.6
3.6
3.6
3.6
V
V
V
V
V
V
2.7
10.5
–1.0
–10.0
3.0
15.0
0.0
–7.5
3.6
16.0
+3.0
–6.0
V
V
V
V
36
370
10
10
1
130
10
105
42
57
26
mW
mW
mW
mW
mW
mW
mW
mW
mW
mW
60
70
70
110
mW
mW
mW
mW
MHz
The total power dissipated by the HVDD supply may be approximated using the equation Total HVDD Power = [CLOAD × HVDD × Pixel Frequency] × HVDD.
Reducing the H-loading and/or using a lower HVDD supply will reduce the power dissipation. CLOAD is the total capacitance seen by all H-outputs.
The power dissipated by the V-driver circuitry depends on the logic states of the inputs as well as actual CCD operation; default dc values are used for each measurement, in each mode of operation. Load conditions are described in the Vertical Driver Specifications section.
Rev. A | Page 3 of 96
AD9925
DIGITAL SPECIFICATIONS
RGVDD = HVDD = DVDD = DRVDD = 2.7 V to 3.6 V, CL = 20 pF, TMIN to TMAX, unless otherwise noted.
Table 2.
Parameter
LOGIC INPUTS
High Level Input Voltage
Low Level Input Voltage
High Level Input Current
Low Level Input Current
Input Capacitance
LOGIC OUTPUTS (Powered by DVDD, DRVDD)
High Level Output Voltage at IOH = 2 mA
Low Level Output Voltage at IOL = 2 mA
RG and H-DRIVER OUTPUTS (Powered by HVDD, RGVDD)
High Level Output Voltage at Maximum Current
Low Level Output Voltage at Maximum Current
Maximum Output Current (Programmable)
Maximum Load Capacitance (for Each Output)
Symbol
Min
VIH
VIL
IIH
IIL
CIN
2.1
VOH
VOL
VDD – 0.5
Typ
Max
0.6
10
10
10
0.5
VDD – 0.5
0.5
30
100
Rev. A | Page 4 of 96
Unit
V
V
µA
µA
pF
V
V
V
V
mA
pF
AD9925
VERTICAL DRIVER SPECIFICATIONS
VDVDD = 3.3 V, VH = 15 V, VM = 0 V, VL = −7.5 V, CL shown in load model, 25°C.
Table 3.
Parameter
3-LEVEL OUTPUTS (V1, V2, V3A, V3B, V5A, V5B)
(Simplified Load Conditions, 6000 pF to Ground)
Delay Time, VL to VM and VM to VH
Delay Time, VM to VL and VH to VM
Rise Time, VL to VM and VM to VH
Fall Time, VM to VL and VH to VM
Output Currents
At −7.25 V
At −0.25 V
At +0.25 V
At +14.75 V
2-LEVEL OUTPUTS (V4, V6, V7, V8)
(Simplified Load Conditions, 6000 pF to Ground)
Delay Time, VL to VM
Delay Time, VM to VL
Rise Time, VL to VM
Fall Time, VM to VL
Output Currents
At −7.25 V
At −0.25 V
SUBCK OUTPUT
(Simplified Load Conditions, 1000 pF to Ground)
Delay Time, VL to VH
Delay Time, VH to VL
Rise Time, VL to VH
Fall Time, VH to VL
Output Currents
At −7.25 V
At +14.75 V
SERIAL VERTICAL CLOCK RESISTANCE
GND VERTICAL CLOCK RESISTANCE
Min
Typ
tPLM, tPMH
tPML, tPHM
tRLM, tRMH
tFML, tFHM
Max
Unit
100
200
500
500
ns
ns
ns
ns
10.0
−5.0
5.0
−7.2
mA
mA
mA
mA
tPLM
tPML
tRLM
tFML
100
200
500
500
10.0
−5.0
tPLH
tPHL
tRLH
tFHL
100
200
200
200
5.4
−4.0
30
10
50%
tRLM, tRMH, tRLH
90%
tPML, tPHM, tPHL
90%
tPLM, tPMH, tPLH
10%
tFML, tFHM, tFHL
10%
Figure 2. Definition of V-Driver Timing Specifications
Rev. A | Page 5 of 96
ns
ns
ns
ns
mA
mA
Ω
Ω
50%
V-DRIVER
OUTPUT
ns
ns
ns
ns
mA
mA
04637-0-079
V-DRIVER
INPUT
Symbol
AD9925
ANALOG SPECIFICATIONS
AVDD1 = 3.0 V, fCLI = 36 MHz, typical timing specifications, TMIN to TMAX, unless otherwise noted.
Table 4.
Parameter
CDS
Allowable CCD Reset Transient
Maximum Input Range before Saturation
0 dB CDS Gain (Default Setting)
−2 dB CDS Gain
−4 dB CDS Gain
Maximum CCD Black Pixel Amplitude
VARIABLE GAIN AMPLIFIER (VGA)
Gain Control Resolution
Gain Monotonicity
Gain Range
Minimum Gain (VGA Code 0)
Maximum Gain (VGA Code 1023)
BLACK LEVEL CLAMP
Clamp Level Resolution
Clamp Level
Minimum Clamp Level (Code 0)
Maximum Clamp Level (Code 255)
ANALOG-TO-DIGITAL CONVERTER (ADC)
Resolution
Differential Nonlinearity (DNL)
No Missing Codes
Full-Scale Input Voltage
VOLTAGE REFERENCE
Reference Top Voltage (REFT)
Reference Bottom Voltage (REFB)
SYSTEM PERFORMANCE
Gain Accuracy
Low Gain (VGA Code 0)
Maximum Gain (VGA Code 1023)
Peak Nonlinearity, 500 mV Input Signal
Total Output Noise
Min
Max
500
mV
1.0
1.25
1.6
+200/–100
V p-p
V p-p
V p-p
mV
1024
Guaranteed
Steps
6
42
dB
dB
256
Steps
0
255
LSB
LSB
12
–1.0
±0.5
Guaranteed
2.0
+1.0
2.0
1.0
Positive Offset Definition1
Bits
LSB
V
V
Includes Entire Signal Chain.
5.0
40.5
5.5
41.5
0.1
0.8
6.0
42.5
50
04637-0-002
1V MAX
INPUT SIGNAL RANGE
(0dB CDS GAIN)
Test Conditions/Comments
Input Characteristics Definition.1
V
Input signal characteristics are defined as
500mV TYP
RESET TRANSIENT
+200mV MAX
OPTICAL BLACK PIXEL
Unit
Measured at ADC Output.
Power Supply Rejection (PSR)
1
Typ
Rev. A | Page 6 of 96
dB
dB
%
LSB rms
dB
Gain = (0.0351 × Code) + 5.5 dB.
12 dB Gain Applied.
AC Grounded Input, 6 dB Gain Applied.
Measured with Step Change on
Supply.
AD9925
TIMING SPECIFICATIONS
CL = 20 pF, AVDD = DVDD = DRVDD = 3.0 V, fCLI = 36 MHz, unless otherwise noted.
Table 5.
Parameter
MASTER CLOCK, CLI (Figure 17)
CLI Clock Period
CLI High/Low Pulse Width
Delay from CLI Rising Edge to Internal Pixel Position 0
AFE CLPOB PULSE WIDTH1, 2 (Figure 23 and Figure 29)
AFE SAMPLE LOCATION1 (Figure 20)
SHP Sample Edge to SHD Sample Edge
DATA OUTPUTS (Figure 21 and Figure 22)
Output Delay from DCLK Rising Edge, Default Value1
Inhibited Area for DOUTPHASE Edge Location1
Pipeline Delay from SHP/SHD Sampling to DOUT
SERIAL INTERFACE (Figure 74 and Figure 75)
Maximum SCK Frequency
SL to SCK Setup Time
SCK to SL Hold Time
SDATA Valid to SCK Rising Edge Setup
SCK Falling Edge to SDATA Valid Hold
SCK Falling Edge to SDATA Valid Read
1
2
Symbol
Min
Typ
Max
tCONV
27.8
11.2
16.6
2
13.9
6
20
12.5
13.9
tCLIDLY
tS1
tOD
tDOUTINH
fSCLK
tLS
tLH
tDS
tDH
tDV
ns
SHDLOC + 11
36
10
10
10
10
10
Parameter is register-programmable.
Minimum CLPOB pulse width is for functional operation only. Wider typical pulses are recommended to achieve good clamp performance.
Rev. A | Page 7 of 96
ns
ns
ns
Pixels
ns
8
SHDLOC
11
Unit
Cycles
MHz
ns
ns
ns
ns
ns
AD9925
ABSOLUTE MAXIMUM RATINGS
Table 6.
Parameter
VDVDD
With
Respect To
VDVSS
VL
VDVSS
VH1, VH2
VDVSS
VM1, VM2
VDVSS
AVDD
TCVDD
HVDD
RGVDD
DVDD
DRVDD
RG Output
AVSS
TCVSS
HVSS
RGVSS
DVSS
DRVSS
RGVSS
VDVSS
– 0.3
VDVSS
– 10
VL –
0.3
VL –
0.3
–0.3
–0.3
–0.3
–0.3
–0.3
–0.3
–0.3
H1 to H4 Output
HVSS
–0.3
Digital Outputs
DVSS
–0.3
Digital Inputs
DVSS
–0.3
SCK, SL, SDATA
DVSS
–0.3
REFT/REFB, CCDIN
AVSS
–0.3
Junction Temperature
Lead Temperature,
10 s
Min
Max
Unit
VDVSS
+4
VDVSS
+ 0.3
VL +
27
VL +
27
+3.9
+3.9
+3.9
+3.9
+3.9
+3.9
RGVD
D + 0.3
HVDD
+ 0.3
DVDD
+ 0.3
DVDD
+ 0.3
DVDD
+ 0.3
AVDD
+ 0.3
150
V
350
°C
V
V
Stresses above those listed under Absolute Maximum Ratings
may cause permanent damage to the device. This is a stress
rating only, and functional operation of the device at these or
any other conditions above those indicated in the operational
section of this specification is not implied. Exposure to absolute
maximum rating conditions for extended periods may affect
device reliability.
V
V
V
V
V
V
V
V
PACKAGE THERMAL CHARACTERISTICS
Thermal Resistance
CSPBGA Package: θJA = 40.3°C/W
V
V
V
V
V
°C
ESD CAUTION
ESD (electrostatic discharge) sensitive device. Electrostatic charges as high as 4000 V readily accumulate
on the human body and test equipment and can discharge without detection. Although this product features
proprietary ESD protection circuitry, permanent damage may occur on devices subjected to high energy electrostatic discharges. Therefore, proper ESD precautions are recommended to avoid performance degradation
or loss of functionality.
Rev. A | Page 8 of 96
AD9925
PIN CONFIGURATION AND FUNCTION DESCRIPTIONS
AD9925
TOPVIEW
(Not to Scale)
A
B
C
D
E
F
G
H
J
K
L
04637-0-003
A1 CORNER
INDEX AREA
1 2 3 4 5 6 7 8 9 10 11
Figure 3. 96-Lead CSPBGA Package Pin Configuration
Table 7. Pin Function Descriptions
Pin No.
E1, F2, F3
G2, G3
F1
G1
H1, H2, H3
J2, J3
J1
K1
K2, L2
L3
L4
K3, K4
J4
J5
K5, L5
J6
K6, L7
L6
K7
L8
L9
J7
J8
K8
K9
L10
K11
J11
J10
J9
K10
H9
H11
H10
G10
G11
G9
Mnemonic
HVSS
HVSS
H1
H2
HVDD
HVDD
H3
H4
RGVSS
RG
RGVDD
TCVDD
CLO
SYNC
TCVSS
CLI
AVSS
CCDIN
AVDD
REFT
REFB
MSHUT
SUBCK
VL
VH2
RSTB
SL
SCK
SDI
V8
V7
STROBE
VM2
V6
V4
V2
VD
Type1
P
P
DO
DO
P
P
DO
DO
P
DO
P
P
DO
DI
P
DI
P
AI
P
AO
AO
DO
DO
P
P
DI
DI
DI
DI
VO2
VO2
DO
P
VO2
VO2
VO2
DIO
Description2
H1 to H4, HL Driver Ground
H1 to H4, HL Driver Ground
CCD Horizontal Clock 1
CCD Horizontal Clock 2
H1 to H4, HL Driver Supply
H1 to H4, HL Driver Supply
CCD Horizontal Clock 3
CCD Horizontal Clock 4
RG Driver Ground
CCD Reset Gate Clock
RG Driver Supply
Analog Supply for Timing Core
Clock Output for Crystal
External System Sync Input
Analog Ground for Timing Core
Reference Clock Input
Analog Ground for AFE
CCD Signal Input
Analog Supply for AFE
Voltage Reference Top Bypass
Voltage Reference Bottom Bypass
Mechanical Shutter Pulse
CCD Substrate Clock (E Shutter)
V-Driver Low Supply
V-Driver High Supply 2
Reset Bar, Active Low Pulse
3-Wire Serial Load Pulse
3-Wire Serial Clock
3-Wire Serial Data Input
CCD Vertical Transfer Clock
CCD Vertical Transfer Clock
Strobe Pulse
V-Driver Mid Supply 2
CCD Vertical Transfer Clock
CCD Vertical Transfer Clock
CCD Vertical Transfer Clock
Vertical Sync Pulse (Input in Slave Mode, Output in Master Mode)
Rev. A | Page 9 of 96
AD9925
Pin No.
F9
F10
F11
E9
D9
E10
D11
C10
C11
B10
B11
A10
A9
C9
B9
B8
A8
B7
A7
B6
A6
C8
C7
C6
C5
B5
A5
A4
B4
A1, A2, A3
B1, B2, B3
C1, C2, C3
C4, D1, D2
D3, E2, E3
D10, E11
L1, L11, A11
Mnemonic
HD
DVSS
DVDD
V5B
V5A
DCLK
D0
D1
D2
D3
D4
D5
D6
V3B
V3A
V1
D7
D8
D9
D10
D11
VM1
VH1
VL
DRVDD
DRVSS
VSUB
VDVDD
VDVSS
NC
NC
NC
NC
NC
NC
NC
Type1
DIO
P
P
VO3
VO3
DO
DO
DO
DO
DO
DO
DO
DO
VO3
VO3
VO3
DO
DO
DO
DO
DO
P
P
P
P
P
DO
P
P
Description2
Horizontal Sync Pulse (Input in Slave Mode, Output in Master Mode)
Digital Ground
Digital Logic Power Supply
CCD Vertical Transfer Clock
CCD Vertical Transfer Clock
Data Clock Output
Data Output (LSB)
Data Output
Data Output
Data Output
Data Output
Data Output
Data Output
CCD Vertical Transfer Clock
CCD Vertical Transfer Clock
CCD Vertical Transfer Clock
Data Output
Data Output
Data Output
Data Output
Data Output (MSB)
V-Driver Mid Supply 1
V-Driver High Supply 1
V-Driver Low Supply
Data Output Driver Supply
Data Output Driver Ground
CCD Substrate Bias
V-Driver Logic Supply
V-Driver Logic Ground
Not Internally Connected
Not Internally Connected
Not Internally Connected
Not Internally Connected
Not Internally Connected
Not Internally Connected
Not Internally Connected
1
AI = Analog Input; AO = Analog Output; DI = Digital Input; DO = Digital Output; DIO = Digital Input/Output; P = Power; VO2 = V-Driver Output 2-Level; VO3 = V-Driver
Output 3-Level.
2
See Figure 73 for circuit configuration.
Rev. A | Page 10 of 96
AD9925
TERMINOLOGY
Differential Nonlinearity (DNL)
Total Output Noise
An ideal ADC exhibits code transitions that are exactly 1 LSB
apart. DNL is the deviation from this ideal value. Thus, every
code must have a finite width. No missing codes guaranteed to
12-bit resolution indicates that all 4096 codes, respectively, must
be present over all operating conditions.
The rms output noise is measured using histogram techniques.
The standard deviation of the ADC output codes is calculated
in LSB and represents the rms noise level of the total signal
chain at the specified gain setting. The output noise can be converted to an equivalent voltage, using the relationship 1 LSB =
ADC Full Scale/2n codes, where n is the bit resolution of the
ADC. For the AD9925, 1 LSB is 0.488 mV.
Peak Nonlinearity
Peak nonlinearity, a full signal chain specification, refers to the
peak deviation of the output of the AD9925 from a true straight
line. The point used as zero scale occurs 0.5 LSB before the first
code transition. Positive full scale is defined as a Level 1 and is
0.5 LSB beyond the last code transition. The deviation is measured from the middle of each particular output code to the true
straight line. The error is then expressed as a percentage of the
2 V ADC full-scale signal. The input signal is always appropriately gained up to fill the ADC’s full-scale range.
Power Supply Rejection (PSR)
The PSR is measured with a step change applied to the supply
pins. The PSR specification is calculated from the change in the
data outputs for a given step change in the supply voltage.
Rev. A | Page 11 of 96
AD9925
EQUIVALENT CIRCUITS
AVDD
DVDD
R
100kΩ
AVSS
DVSS
Figure 4. CCDIN
DVDD
04637-0-075
AVSS
04637-0-004
300Ω
Figure 7. SL and RSTB Inputs
DRVDD
HVDD OR
RGVDD
DATA
RG, H1 TO H4
THREESTATE
DOUT
DRVSS
04637-0-005
DVSS
HVSS OR
RGVSS
Figure 8. H1 to H4, RG Drivers
Figure 5. Digital Data Outputs
DVDD
DVSS
04637-0-006
330Ω
Figure 6. Digital Inputs
Rev. A | Page 12 of 96
04637-0-007
OUTPUT
THREE-STATE
AD9925
TYPICAL PERFORMANCE CHARACTERISTICS
450
40
VDD = 3.3V
35
30
VDD = 3.0V
350
NOISE (LSB)
POWER DISSIPATION (mW)
400
VDD = 2.7V
300
250
25
20
15
10
200
36
0
0
5
0.8
4
0.6
3
0.4
2
0.2
1
LSB
1.0
0
–1
–0.4
–2
–0.6
–3
–0.8
–4
0
500
1000
1500 2000 2500 3000
ADC OUTPUT CODE
3500
4000
Figure 10. Typical DNL Performance
40
35
25
20
15
10
5
100
200
300
400 500 600 700
GAIN CODE (Decimal)
800
900 1000
04637-0-081
GAIN (dB)
30
0
400 500 600 700
GAIN CODE (Decimal)
800
–5
0
500
1000
1500 2000 2500 3000
ADC OUTPUT CODE
Figure 13. Typical INL Performance
45
0
300
900 1000
0
–0.2
–1.0
200
Figure 12. Total Output Noise vs. VGA Gain
04637-0-080
LSB
Figure 9. Power vs. Sample Rate
100
04637-0-083
24
30
SAMPLE RATE (MHz)
Figure 11. Typical VGA Gain Curve
Rev. A | Page 13 of 96
3500
4000
04637-0-082
150
18
04637-0-084
5
AD9925
SYSTEM OVERVIEW
Figure 14 shows the typical system block diagram for the
AD9925 used in master mode. The CCD output is processed by
the AD9925’s AFE circuitr y, which consists of a CDS, VGA,
black level clamp, and ADC. The digitized pixel information is
sent to the digital image processor chip, which performs the
postprocessing and compression. To operate the CCD, all CCD
timing parameters are programmed into the AD9925 from the
system microprocessor through the 3-wire serial interface.
From the system master clock, CLI, provided by the image
processor or external crystal, the AD9925 generates the CCD’s
horizontal and vertical clocks and internal AFE clocks. External
synchronization is provided by a SYNC pulse from the microprocessor, which will reset internal counters and resync the VD
and HD outputs. The AD9925 also contains an optional reset
pin, RSTB, which may be used to perform an asynchronous
hardware reset function.
V1A, V2, V3A, V3B, V4, V5A,
V5B, V6, V7, V8, SUBCK, VSUB
Alternatively, the AD9925 may be operated in slave mode, in
which the VD and HD are provided externally from the image
processor. In this mode, all AD9925 timing will be synchronized with VD and HD.
The H-drivers for H1 to H4 and RG are included in the
AD9925, allowing these clocks to be directly connected to the
CCD. An H-drive voltage of up to 3.3 V is supported. A high
voltage V-driver is also included for the vertical clocks, allowing
direct connection to the CCD. The SUBCK and VSUB signals
may require external transistors, depending on the CCD used.
The AD9925 also includes programmable MSHUT and
STROBE outputs, which may be used to trigger mechanical
shutter and strobe (flash) circuitry.
Figure 15 and Figure 16 show the maximum horizontal and
vertical counter dimensions for the AD9925. All internal horizontal and vertical clocking is controlled by these counters to
specify line and pixel locations. Maximum HD length is 8192
pixels per line, and maximum VD length is 4096 lines per field.
MAXIMUM
COUNTER
DIMENSIONS
H1 TO H4, RG
DOUT
CCD
MSHUT
STROBE
AD9925
DCLK
AFETG
+
V-DRIVER
HD, VD
DIGITAL
IMAGE
PROCESSING
ASIC
CLI
13-BIT HORIZONTAL = 8192 PIXELS MAX
SERIAL
INTERFACE
12-BIT VERTICAL = 4096 LINES MAX
SYNC
04637-0-008
µP
04637-0-009
CCDIN
RSTB
Figure 15. Vertical and Horizontal Counters
Figure 14. Typical System Block Diagram, Master Mode
MAX VD LENGTH IS 4096 LINES
VD
MAX HD LENGTH IS 8192 PIXELS
04637-0-010
HD
CLI
Figure 16. Maximum VD/HD Dimensions
Rev. A | Page 14 of 96
AD9925
PRECISION TIMING HIGH SPEED TIMING GENERATION
crystal can be placed between the CLI and CLO pins to generate
the master clock for the AD9925. For more information on
using a crystal, see Figure 72.
The AD9925 generates high speed timing signals using the flexible Precision Timing core. This core is the foundation that generates the timing used for both the CCD and the AFE: the reset
gate (RG), horizontal drivers H1 to H4, and the SHP/SHD sample
clocks. The unique architecture provides precise control over
the horizontal CCD readout and the AFE correlated double sampling, allowing the system designer to optimize image quality.
High Speed Clock Programmability
Figure 18 shows how the high speed clocks RG, H1 to H4, SHP,
and SHD are generated. The RG pulse has programmable rising
and falling edges and may be inverted using the polarity control.
The horizontal clocks, H1 and H3, have programmable rising
and falling edges and polarity control. The H2 and H4 clocks
are always inverses of H1 and H3, respectively. Table 8 summarizes the high speed timing registers and their parameters.
Figure 19 shows the typical 2-phase H-clock arrangement in
which H3 and H4 are programmed for the same edge location
as H1 and H2.
The high speed timing of the AD9925 operates the same in
either master or slave mode configuration. For more information on synchronization and pipeline delays, see the Power-Up
and Synchronization section.
Timing Resolution
The Precision Timing core uses a 13 master clock input (CLI) as
a reference. This clock should be the same as the CCD pixel
clock frequency. Figure 17 illustrates how the internal timing
core divides the master clock period into 48 steps or edge positions. Using a 20 MHz CLI frequency, the edge resolution of the
Precision Timing core is 1 ns. If a 1× system clock is not available, it is also possible to use a 2× reference clock by programming the CLIDIVIDE register (Addr x30). The AD9925 will
then internally divide the CLI frequency by two.
The edge location registers are 6 bits wide, but there are only
48 valid edge locations available. Therefore, the register values
are mapped into four quadrants, with each quadrant containing
12 edge locations. Table 9 shows the correct register values for
the corresponding edge locations.
The AD9925 also includes a master clock output, CLO, which is
the inverse of CLI. This output can be used as a crystal driver. A
POSITION
P[0]
P[12]
P[24]
P[36]
P[48] = P[0]
CLI
tCLIDLY
NOTES
1. PIXEL CLOCK PERIOD IS DIVIDED INTO 48 POSITIONS, PROVIDING FINE EDGE RESOLUTION FOR HIGH SPEED CLOCKS.
2. THERE IS A FIXED DELAY FROM THE CLI INPUT TO THE INTERNAL PIXEL PERIOD POSITION (tCLIDLY = 6ns TYP).
Figure 17. High Speed Clock Resolution from CLI Master Clock Input
Rev. A | Page 15 of 96
04637-0-011
1 PIXEL
PERIOD
AD9925
3
CCD
SIGNAL
4
1
2
RG
5
6
H1
H2
7
8
H3
PROGRAMMABLE CLOCK POSITIONS:
1. RG RISING EDGE.
2. RG FALLING EDGE.
3. SHP SAMPLE LOCATION.
4. SHD SAMPLE LOCATION.
5. H1 RISING EDGE POSITION AND 6: H1 FALLING EDGE POSITION (H2 IS INVERSE OF H1).
7. H3 RISING EDGE POSITION AND 8: H3 FALLING EDGE POSITION (H4 IS INVERSE OF H3).
04637-0-012
H4
Figure 18. High Speed Clock Programmable Locations
Digital Data Outputs
Figure 20 shows the default timing locations for all of the high
speed clock signals.
The AD9925 data output and DCLK phase are programmable
using the DOUTPHASE register (Addr x37, Bits [5:0]). Any
edge from 0 to 47 may be programmed, as shown in Figure 21.
Normally, the DOUT and DCLK signals will track in phase,
based on the DOUTPHASE register contents. The DCLK output phase can also be held fixed with respect to the data outputs
by changing the DCLKMODE register high (Addr x37, Bit [6]).
In this mode, the DCLK output will remain at a fixed phase
equal to CLO (the inverse of CLI), while the data output phase
is still programmable.
H-Driver and RG Outputs
In addition to the programmable timing positions, the AD9925
features on-chip output drivers for the RG and H1 to H4 outputs. These drivers are powerful enough to directly drive the
CCD inputs. The H-driver and RG current can be adjusted for
optimum rise/fall time with a particular load by using the
DRVCONTROL register (Addr x35). The 3-bit drive setting for
each output is adjustable in 4.1 mA increments, with the minimum setting of 0 equal to OFF or three-state and the maximum
setting of 7 equal to 30.1 mA.
There is a fixed output delay from the DCLK rising edge to the
DOUT transition, called tOD. This delay can be programmed to
four values between 0 ns and 12 ns by using the DOUTDELAY
register (Addr x37, Bits [8:7]). The default value is 8 ns.
As shown in Figure 18, Figure 19, and Figure 20, the H2 and H4
outputs are inverses of H1 and H3, respectively. The H1/H2
crossover voltage is approximately 50% of the output swing. The
crossover voltage is not programmable.
The pipeline delay through the AD9925 is shown in Figure 22.
After the CCD input is sampled by SHD, there is an 11 cycle
delay until the data is available.
Table 8. Timing Core Register Parameters for H1, H3, RG, SHP/SHD
Parameter
Polarity
Positive Edge
Negative Edge
Sampling Location
Drive Strength
Length
1b
6b
6b
6b
3b
Range
High/Low
0 to 47 Edge Location
0 to 47 Edge Location
0 to 47 Edge Location
0 to 47 Current Steps
Description
Polarity Control for H1, H3, and RG (0 = No Inversion, 1 = Inversion)
Positive Edge Location for H1, H3, and RG
Negative Edge Location for H1, H3, and RG
Sampling Location for Internal SHP and SHD Signals
Drive Current for H1 to H4 and RG Outputs (4.1 mA per Step)
Rev. A | Page 16 of 96
AD9925
CCD
SIGNAL
RG
H1/H3
04637-0-013
H2/H4
NOTE
1. USING THE SAME TOGGLE POSITIONS FOR H1 AND H3 GENERATES STANDARD 2-PHASE H-CLOCKING.
Figure 19. 2-Phase H-Clock Operation
Table 9. Precision Timing Edge Locations
Quadrant
I
II
III
IV
Edge Location (Dec)
0 to 11
12 to 23
24 to 35
36 to 47
POSITION
P[0]
P[12]
RGr[0]
RGf[12]
Register Value (Dec)
0 to 11
16 to 27
32 to 43
48 to 59
P[24]
Register Value (Bin)
000000 to 001011
010000 to 011011
100000 to 101011
110000 to 111011
P[36]
P[48] = P[0]
PIXEL
PERIOD
RG
Hr[0]
Hf[24]
H1/H3
H2/H4
SHP[24]
tS1
CCD
SIGNAL
NOTES
1. ALL SIGNAL EDGES ARE FULLY PROGRAMMABLE TO ANY OF THE 48 POSITIONS WITHIN ONE PIXEL PERIOD.
2. DEFAULT POSITIONS FOR EACH SIGNAL ARE SHOWN.
Figure 20. High Speed Timing Default Locations
Rev. A | Page 17 of 96
04637-0-014
SHD[48]
AD9925
P[0]
P[12]
P[36]
P[24]
P[48] = P[0]
PIXEL
PERIOD
DCLK
tOD
DOUT
04637-0-015
NOTES
1. DATA OUTPUT (DOUT) AND DCLK PHASE IS ADJUSTABLE WITH RESPECT TO THE PIXEL PERIOD.
2. WITHIN 1 CLOCK PERIOD, THE DATA TRANSITION CAN BE PROGRAMMED TO 48 DIFFERENT LOCATIONS.
3. OUTPUT DELAY (tOD) FROM DCLK RISING EDGE TO DOUT RISING EDGE IS PROGRAMMABLE.
Figure 21. Digital Output Phase Adjustment
CLI
tCLIDLY
N
N–1
N+1
N+2
N+3
N+4
N+5
N+6
N+7
N+8
N+9
N + 10
N + 11
N–2
N–1
N + 12
N + 13
CCDIN
SAMPLE PIXEL N
SHD
(INTERNAL)
ADC DOUT
(INTERNAL)
N – 13
N – 12
N – 11
N – 10
N–9
N–8
N–7
N–6
N–5
N–4
N–3
N+1
N
N+2
tDOUTINH
DCLK
PIPELINE LATENCY = 11 CYCLES
N – 13
N – 12
N – 11
N – 10
N–9
N–8
N–7
N–6
N–5
N–4
N–3
N–2
N–1
N
N+1
N+2
NOTES
1. TIMING VALUES SHOWN ARE SHDLOC = 0, WITH DCLKMODE = 0.
2. HIGHER VALUES OF SHD AND/OR DOUTPHASE WILL SHIFT DOUT TRANSITION TO THE RIGHT, WITH RESPECT TO CLI LOCATION.
3. INHIBIT TIME FOR DOUT PHASE IS DEFINED BY tDOUTINH, WHICH IS EQUAL TO SHDLOC PLUS 11 EDGES. IT IS RECOMMENDED THAT THE
11 EDGE LOCATIONS FOLLOWING SHDLOC NOT BE USED FOR THE DOUTPHASE LOCATION.
4. RECOMMENDED VALUE FOR DOUT PHASE IS TO USE THE SHPLOC EDGE OR THE 11 EDGES FOLLOWING SHPLOC.
5. RECOMMENDED VALUE FOR tOD (DOUT DLY) IS 4ns.
6. THE DOUT LATCH CAN BE BYPASSED USING REGISTER 0x03, BIT [4] = 1, SO THAT THE ADC DATA OUTPUTS APPEAR DIRECTLY AT THE
DOUT PINS. THIS CONFIGURATION IS RECOMMENDED IF ADJUSTABLE DOUT PHASE IS NOT REQUIRED.
04637-A-001
DOUT
Figure 22. Digital Data Output Pipeline Delay
HORIZONTAL CLAMPING AND BLANKING
The AD9925’s horizontal clamping and blanking pulses are fully
programmable to suit a variety of applications. Individual control is provided for CLPOB, PBLK, and HBLK during the different regions of each field. This allows the dark pixel clamping
and blanking patterns to be changed at each stage of the readout, which accommodates the different image transfer timing
and high speed line shifts.
Individual CLPOB and PBLK Patterns
The AFE horizontal timing consists of CLPOB and PBLK, as
shown in Figure 23. These two signals are independently programmed using the registers in Table 10. SPOL is the start polarity for the signal, and TOG1 and TOG2 are the first and second toggle positions of the pulse. Both signals are active low
and should be programmed accordingly.
A separate pattern for CLPOB and PBLK may be programmed
for every 10 vertical sequences. As described in the Vertical
Timing Generation section, up to 10 separate vertical sequences
can be created, each containing a unique pulse pattern for
CLPOB and PBLK. Figure 37 shows how the sequence change
positions divide the readout field into different regions. A different vertical sequence can be assigned to each region, allowing
the CLPOB and PBLK signals to be changed accordingly with
each change in the vertical timing.
CLPOB Masking Area
Additionally, the AD9925 allows the CLPOB signal to be disabled during certain lines in the field without changing any of
the existing CLPOB pattern settings. There are two ways to use
CLPOB masking. First, the six CLPOBMASK registers can be used
Rev. A | Page 18 of 96
AD9925
to specify six individual lines within the field. These lines will not
contain an active CLPOB pulse. CLPMASKTYPE is set low for this
mode of operation.
Second, the CLPMASK registers can be used to specify blocks
of adjacent lines. The CLPMASK start and end line values are programmed to specify the starting and ending lines in the field, where
the CLPOB patterns will be ignored. There are three sets of start
and end values, allowing up to three CLPOB masking areas to be
created. CLPMASKTYPE is set high for this mode of operation.
The CLPOB masking registers are not specific to a certain vertical
sequence; they are always active for any existing field of timing.
To disable the CLPOB masking feature, these registers should
be set to the maximum value of 0xFFF (default value).
Individual HBLK Patterns
The HBLK programmable timing shown in Figure 24 is similar
to CLPOB and PBLK, but there is no start polarity control. Only
the toggle positions are used to designate the start and the stop
positions of the blanking period. Additionally, there is a polarity
control HBLKMASK that designates the polarity of the horizontal
clock signals H1 to H4 during the blanking period. Setting
HBLKMASK high will set H1 = H3 = Low and H2 = H4 = High
during the blanking, as shown in Figure 25. As with the CLPOB
and PBLK signals, HBLK registers are available in each vertical
sequence, which allow different blanking signals to be used with
different vertical timing sequences.
One additional feature is the ability to enable the H3/H4 signals
to remain active during HBLK. To do this, set register Bit D6 in
Addr 0xE7 equal to 1. This feature is useful if the H3 output is
used to drive the HL (last horizontal gate) input of the CCD.
Table 10. CLPOB and PBLK Pattern Registers
Register
SPOL
TOG1
TOG2
CLPOBMASK
Length
1b
12 b
12 b
12 b
Range
High/Low
0 to 4095 Pixel Location
0 to 4095 Pixel Location
0 to 4095 Line Location
CLPMASKTYPE
1b
High/Low
Description
Starting Polarity of CLPOB/PBLK for Vertical Sequence 0 to 9.
First Toggle Position within Line for Vertical Sequence 0 to 9.
Second Toggle Position within Line for Vertical Sequence 0 to 9.
CLPOBMASK0 through CLPOBMASK5 specify six individual lines in the field for the
CLPOB pulse to be temporarily disabled. These registers can also be used to specify
three ranges of adjacent lines, rather than six individual lines.
When set low (default), the CLPOBMASK registers select individual lines in the field
to disable the CLPOB pulse. When set high, the range masking is enabled, allowing
up to three blocks of adjacent lines to have the CLPOB signal masked. CLPOBMASK0 and CLPOBMASK1 are the start/end of the first block of lines, CLPOBMASK2
and CLPOBMASK3 are the start/end of the second block, and CLPOBMASK4 and
CLPOBMASK5 are the start/end of the third block.
HD
3
ACTIVE
ACTIVE
NOTES
PROGRAMMABLE SETTINGS:
1. START POLARITY (CLAMP AND BLANK REGION ARE ACTIVE LOW).
2. FIRST TOGGLE POSITION.
3. SECOND TOGGLE POSITION.
Figure 23. Clamp and Preblank Pulse Placement
Rev. A | Page 19 of 96
04637-0-017
2
CLPOB 1
PBLK
AD9925
Table 11. HBLK Pattern Registers
Register
HBLKMASK
H3HBLKOFF
HBLKALT
Length
1b
1b
2b
Range
High/Low
High/Low
0 to 3 Alternation Mode
HBLKTOG1
HBLKTOG2
HBLKTOG3
HBLKTOG4
HBLKTOG5
HBLKTOG6
12 b
12 b
12 b
12 b
12 b
12 b
0 to 4095 Pixel Location
0 to 4095 Pixel Location
0 to 4095 Pixel Location
0 to 4095 Pixel Location
0 to 4095 Pixel Location
0 to 4095 Pixel Location
Description
Masking Polarity for H1/H3 (0 = H1/H3 Low, 1 = H1/H3 High).
Addr 0xE7, Bit [6]. Set = 1 to keep H3/H4 active during HBLK pulse. Normal set to 0.
Enables Odd/Even Alternation of HBLK Toggle Positions.
0 = Disable Alternation.
1 = TOG1 to TOG2 Odd, TOG3 to TOG6 Even.
2 = 3 = TOG1to TOG2 Even, TOG3 to TOG6 Odd.
First Toggle Position within Line for Each Vertical Sequence 0 to 9.
Second Toggle Position within Line for Each Vertical Sequence 0 to 9.
Third Toggle Position within Line for Each Vertical Sequence 0 to 9.
Fourth Toggle Position within Line for Each Vertical Sequence 0 to 9.
Fifth Toggle Position within Line for Each Vertical Sequence 0 to 9.
Sixth Toggle Position within Line for Each Vertical Sequence 0 to 9.
Generating Special HBLK Patterns
Generating HBLK Line Alternation
There are six toggle positions available for HBLK. Normally,
only two of the toggle positions are used to generate the standard HBLK interval. However, the additional toggle positions
may be used to generate special HBLK patterns, as shown in
Figure 26. The pattern in this example uses all six toggle positions to generate two extra groups of pulses during the HBLK
interval. By changing the toggle positions, different patterns can
be created.
One further feature of the AD9925 is the ability to alternate different HBLK toggle positions on odd and even lines. This may be
used in conjunction with vertical pattern odd/even alternation or
on its own. When a 1 is written to the HBLKALT register, TOG1
and TOG2 are used on odd lines, while TOG3 to TOG6 are
used on even lines. Writing a 2 to the HBLKALT register gives
the opposite result: TOG1 and TOG2 are used on even lines,
while TOG3 to TOG6 are used on odd lines. See the Vertical
Timing Generation section for more information.
HD
1
BLANK
04637-0-018
HBLK
2
BLANK
PROGRAMMABLE SETTINGS:
1. FIRST TOGGLE POSITION = START OF BLANKING.
2. SECOND TOGGLE POSITION = END OF BLANKING.
Figure 24. Horizontal Blanking (HBLK) Pulse Placement
HD
HBLK
H1/H3
H1/H3
NOTE
1. THE POLARITY OF H1 DURING BLANKING IS PROGRAMMABLE (H2 IS OPPOSITE POLARITY OF H1).
Figure 25. HBLK Masking Control
Rev. A | Page 20 of 96
04637-0-019
H2/H4
AD9925
TOG1
TOG2
TOG3
TOG4
TOG5
TOG6
HBLK
H1/H3
SPECIAL H-BLANK PATTERN IS CREATED USING MULTIPLE HBLK TOGGLE POSITIONS
04637-0-020
H2/H4
Figure 26. Generating Special HBLK Patterns
Increasing H-Clock Width during HBLK
HORIZONTAL TIMING SEQUENCE EXAMPLE
The AD9925 will also allow the H1 to H4 pulse width to be
increased during the HBLK interval. The H-clock pulse width
can increase by reducing the H-clock frequency (see Figure 27).
The HBLKWIDTH register, at Bank 1 Address 0x38, is a 3-bit
register that allows the H-clock frequency to be reduced by 1/2,
1/4, 1/6, 1/8, 1/10, 1/12, or 1/14. The reduced frequency will
only occur for H1 to H4 pulses that are located within the
HBLK area.
Figure 28 shows an example CCD layout. The horizontal register
contains 28 dummy pixels, which will occur on each line clocked
from the CCD. In the vertical direction, there are 10 optical black
(OB) lines at the front of the readout and 2 at the back of the
readout. The horizontal direction has 4 OB pixels in the front
and 48 in the back.
Table 12. HBLK Width Register
Length
3b
Range
1 to 1/14
Description
Controls H1 to H4 width
during HBLK as a fraction of pixel rate
0: same frequency as
pixel rate
1: 1/2 pixel frequency,
i.e., doubles the H1 to H4
pulse width
2: 1/4 pixel frequency
3: 1/6 pixel frequency
4: 1/8 pixel frequency
5: 1/10 pixel frequency
6: 1/12 pixel frequency
7: 1/14 pixel frequency
More elaborate clamping schemes may be used, such as adding
in a separate sequence to clamp during the entire shield OB
lines. This requires configuring a separate vertical sequence for
reading out the OB lines.
HBLK
H1/H3
1/FPIX
2 × (1/FPIX)
H2/H4
H-CLOCK FREQUENCY CAN BE REDUCED DURING HBLK BY 1/2 (AS
SHOWN), 1/4, 1/6, 1/8, 1/10, 1/12, OR 1/14 USING HBLKWIDTH REGISTER
Figure 27. Generating Wide H-Clock Pulses during HBLK Interval
Rev. A | Page 21 of 96
04637-0-070
Register
HBLKWIDTH
Figure 29 shows the basic sequence layout to be used during the
effective pixel readout. The 48 OB pixels at the end of each line
are used for the CLPOB signals. PBLK is optional and is often
used to blank the digital outputs during the noneffective CCD
pixels. HBLK is used during the vertical shift interval. The
HBLK, CLPOB, and PBLK parameters are programmed in the
vertical sequence registers.
AD9925
2 VERTICAL
OB LINES
V
EFFECTIVE IMAGE AREA
10 VERTICAL
OB LINES
H
48 OB PIXELS
4 OB PIXELS
04637-0-021
HORIZONTAL CCD REGISTER
28 DUMMY PIXELS
Figure 28. Example CCD Configuration
OPTICAL BLACK
OB
HD
CCDIN
VERTICAL SHIFT
DUMMY
EFFECTIVE PIXELS
OPTICAL BLACK
VERT SHIFT
SHP
SHD
H1/H3
H2/H4
HBLK
05637-0-022
PBLK
CLPOB
Figure 29. Horizontal Sequence Example
VERTICAL TIMING GENERATION
The AD9925 provides a very flexible solution for generating
vertical CCD timing and can support multiple CCDs and different system architectures. The vertical transfer clocks XV1 to
XV8 are used to shift each line of pixels into the horizontal output register of the CCD. The AD9925 allows these outputs to be
individually programmed into various readout configurations,
using a 4-step process.
Figure 30 shows an overview of how the vertical timing is generated in four steps. First, the individual pulse patterns for XV1
to XV8 are created by using the vertical pattern group registers.
Second, the vertical pattern groups are used to build the
sequences, where additional information is added. Third, the
readout for an entire field is constructed by dividing the field
into different regions and then assigning a sequence to each
region. Each field can contain up to seven different regions to
accommodate the different steps of the readout, such as high
speed line shifts and unique vertical line transfers. Up to six
different fields may be created. Finally, the MODE register allows the different fields to be combined into any order for various readout configurations.
Rev. A | Page 22 of 96
AD9925
CREATE THE VERTICAL PATTERN GROUPS
(MAXIMUM OF 10 GROUPS)
1
2
BUILD THE VERTICAL SEQUENCES BY ADDING LINE START
POSITION, # OF REPEATS, AND HBLK/CLPOB PULSES
(MAXIMUM OF 10 VERTICAL SEQUENCES)
XV1
XV1
XV2
XV2
XV3
XV3
VPAT 0
XV4
VERTICAL SEQUENCE 0
XV5
(VPAT0, 1 REP)
XV4
XV5
XV6
XV6
XV1
XV2
XV1
XV3
XV2
VERTICAL SEQUENCE 1
XV3
(VPAT9, 2 REP)
VPAT 9
XV4
XV5
XV4
XV6
XV5
XV6
XV1
XV2
XV3
VERTICAL SEQUENCE 2
(VPAT9, N REP)
XV4
XV5
XV6
USE THE MODE REGISTER TO CONTROL WHICH FIELDS
ARE USED, AND IN WHAT ORDER
(MAXIMUM OF 7 FIELDS MAY BE COMBINED IN ANY ORDER)
FIELD 0
FIELD 1
BUILD EACH FIELD BY DIVIDING INTO DIFFERENT REGIONS
AND ASSIGNING A DIFFERENT VERTICAL SEQUENCE TO EACH
(MAXIMUM OF 7 REGIONS IN EACH FIELD)
(MAXIMUM OF 6 FIELDS)
FIELD 0
3
FIELD 2
REGION 0: USE VERTICAL SEQUENCE 2
REGION 0: USE V-SEQUENCE 3
REGION 1: USE VERTICAL SEQUENCE 0
REGION 0: USE V-SEQUENCE 3
1: USE V-SEQUENCE
REGION 2:REGION
USE VERTICAL
SEQUENCE 3 2
REGION 1: USE V-SEQUENCE 2
FIELD 3
FIELD 4
REGION 3: USE VERTICAL SEQUENCE 0
REGION 2: USE V-SEQUENCE 1
FIELD 5
FIELD 1
FIELD 4
FIELD 2
REGION 2: USE V-SEQUENCE 1
REGION 4: USE VERTICAL SEQUENCE 2
FIELD 1
FIELD 2
Figure 30. Summary of Vertical Timing Generation
Rev. A | Page 23 of 96
04637-0-023
3
AD9925
Vertical Pattern Groups (VPAT)
The vertical pattern groups define the individual pulse patterns
for each XV1 to XV6 output signal. Table 13 summarizes the
registers available for generating each of the 10 vertical pattern
groups. The start polarity (VPOL) determines the starting
polarity of the vertical sequence and can be programmed high
or low for each XV1 to XV6 output. The first, second, and third
toggle positions (XVTOG1, XVTOG2, and XVTOG3) are the
pixel locations within the line where the pulse transitions. A
fourth toggle position (XVTOG4) is also available for vertical
pattern groups 8 and 9. All toggle positions are 12-bit values,
allowing their placement anywhere in the horizontal line. A
separate register, VPATSTART, specifies the start position of the
vertical pattern groups within the line (see the Vertical Sequences
(VSEQ) section). The VPATLEN register designates the total
length of the vertical pattern group, which determines the number
of pixels between each of the pattern repetitions when repetitions
are used (see the Vertical Sequences (VSEQ) section).
Additional VPAT groups are provided in Register Bank 3 for the
XV7 and XV8 outputs. This allows the AD9925 to remain backward-compatible with the AD9995 register settings while still
providing additional flexibility with XV7 and XV8 for new CCDs.
Table 13. Vertical Pattern Group Registers
Register
XVPOL
XVTOG1
XVTOG2
XVTOG3
XVTOG4
Length
1b
12 b
12 b
12 b
12 b
Range
High/Low
0 to 4096 Pixel Location
0 to 4096 Pixel Location
0 to 4096 Pixel Location
0 to 4096 Pixel Location
VPATLEN
FREEZE1
RESUME1
FREEZE2
RESUME2
12 b
12 b
12 b
12 b
12 b
0 to 4096 Pixels
0 to 4096 Pixel Location
0 to 4096 Pixel Location
0 to 4096 Pixel Location
0 to 4096 Pixel Location
Description
Starting Polarity of Each XV Output
First Toggle Position within Line for Each XV Output
Second Toggle Position within Line for Each XV Output
Third Toggle Position within Line for Each XV Output
Fourth Toggle Position, Only Available in Vertical Pattern Groups 8 and 9 and Also in
XV7 and XV8 Vertical Pattern Groups
Total Length of Each Vertical Pattern Group
Holds the XV Outputs at Their Current Levels (Static DC)
Resumes Operation of the XV Outputs to Finish Their Pattern
Holds the XV Outputs at Their Current Levels (Static DC)
Resumes Operation of the XV Outputs to Finish Their Pattern
START POSITION OF VERTICAL PATTERN GROUP IS PROGRAMMABLE IN VERTICAL SEQUENCE REGISTERS
HD
4
1
2
XV2
3
1
2
XV6
3
1
2
3
PROGRAMMABLE SETTINGS FOR EACH VERTICAL PATTERN:
1. START POLARITY.
2. FIRST TOGGLE POSITION.
3. SECOND TOGGLE POSITION (THIRD TOGGLE POSITION ALSO AVAILABLE,
FOURTH TOGGLE POSITION AVAILABLE FOR VERTICAL PATTERN GROUPS 8 AND 9).
4. TOTAL PATTERN LENGTH FOR ALL XV OUTPUTS.
Figure 31. Vertical Pattern Group Programmability
Rev. A | Page 24 of 96
04637-0-024
XV1
AD9925
Masking Using FREEZE/RESUME Registers
As shown in Figure 33, the FREEZE/RESUME registers are used
to temporarily mask the XV outputs. The pixel locations to
begin the masking (FREEZE) and end the masking (RESUME)
create an area in which the vertical toggle positions are ignored.
At the pixel location specified in the FREEZE register, the XV
outputs will be held static at their current dc state, high or low.
The XV outputs are held until the pixel location specified by the
RESUME register is reached, at which point the signals will
continue with any remaining toggle positions. Two sets of
FREEZE/RESUME registers are provided, allowing the vertical
outputs to be interrupted twice in the same line. The FREEZE
and RESUME positions are programmed in the vertical pattern
group registers, but are enabled separately using the VMASK
registers. The VMASK registers are described in the Vertical
Sequences (VSEQ) section.
HD
NO MASKING AREA
04637-0-025
XV1
XV8
Figure 32. No Vertical Masking
HD
FREEZE
MASKING AREA
FOR XV1 TO XV8
RESUME
XV1
NOTES
1. ALL TOGGLE POSITIONS WITHIN THE FREEZE/RESUME MASKING AREA ARE IGNORED. H-COUNTER CONTINUES TO COUNT DURING MASKING.
2. TWO SEPARATE MASKING AREAS ARE AVAILABLE FOR EACH VPAT GROUP, USING FREEZE1/RESUME1 AND FREEZE2/RESUME2 REGISTERS.
Figure 33. Vertical Masking Using the FREEZE/RESUME Registers
Rev. A | Page 25 of 96
04637-0-026
XV8
AD9925
Hold Area Using FREEZE/RESUME Registers
The FREEZE/RESUME registers can also be used to create a
hold area, in which the XV outputs are temporarily held and
then later continued starting at the point where they were held.
As shown in Figure 34 and Figure 35, this is different than the
VMASK, because the XV outputs continue from where they
stopped rather than continuing from where they would have
been. The hold area temporarily stops the pixel counter for the
XV outputs, while the v-masking allows the counter to continue
during the masking area.
XV7 and XV8 may or may not use the hold area, as shown in
Figure 34 and Figure 35. The hold operation is controlled in the
Bank 3 vertical sequence registers, described in the Vertical
Sequences (VSEQ) section.
HD
FREEZE
HOLD AREA
FOR XV1–XV6
RESUME
XV1
XV6
XV7
XV8
NOTES
1. WHEN HOLD = 1 FOR ANY V-SEQUENCE, THE FREEZE AND RESUME REGISTERS ARE USED TO SPECIFY THE HOLD AREA BOUNDRIES.
2. WHEN XV78HOLDEN = 0, XV7 AND XV8 DO NOT USE THE HOLD AREA, ONLY XV1–XV6. H-COUNTER FOR XV1–XV6 WILL STOP DURING HOLD AREA.
04637-0-072
NO HOLD
AREA FOR
XV7–XV8
Figure 34. Vertical Hold Area Using the FREEZE/RESUME Registers
HD
HOLD AREA
FREEZE FOR XV1 TO XV8 RESUME
XV1
XV6
XV7
NOTES
1. WHEN HOLD = 1 FOR ANY VERTICAL SEQUENCE, THE FREEZE AND RESUME REGISTERS ARE USED TO SPECIFY THE HOLD AREA BOUNDRIES.
2. WHEN XV78HOLDEN = 1, XV7 AND XV8 ALSO USE THE HOLD AREA. H-COUNTER FOR XV1 TO XV8 WILL STOP DURING HOLD AREA.
Figure 35. Apply Hold Area to XV7 and XV8
Rev. A | Page 26 of 96
04637-0-028
XV8
AD9925
Vertical Sequences (VSEQ)
The line length (in pixels) is programmable using the HDLEN
registers. Each vertical sequence can have a different line length
to accommodate the various image readout techniques. The
maximum number of pixels per line is 8192. Note that the 13th bit
(MSB) of the line length is located in a separate register. Also
note that the last line of the field is separately programmable
using the HDLAST register, located in the field register section.
The vertical sequences are created by selecting one of the 10 vertical pattern groups and adding repeats, the start position, and
horizontal clamping and blanking information. Up to 10 vertical sequences may be programmed, each using the registers
shown in Table 14. Figure 36 shows how the different registers
are used to generate each vertical sequence.
The VPATSEL register selects which vertical pattern group will
be used in a given vertical sequence. The basic vertical pattern
group can have repetitions added for high speed line shifts or
line binning by using the VPATREPO and VPATREPE registers.
Generally, the same number of repetitions is programmed into
both registers, but if a different number of repetitions is required on odd and even lines, separate values may be used for
each register (see the Generating Line Alternation for Vertical
Sequence and HBLK section). The VPATSTART register specifies the pixel location where the vertical pattern group will start.
The VMASK register is used in conjunction with the FREEZE/
RESUME registers to enable optional masking of the vertical
outputs. Either or both of the FREEZE1/RESUME1 and
FREEZE2/RESUME2 registers can be enabled using the
VMASK register.
Additional vertical sequences are provided in Register Bank 3
for the XV7 and XV8 outputs. This allows the AD9925 to remain backward-compatible with the AD9995 register settings
while still providing additional flexibility with XV7 and XV8 for
new CCDs.
As described in the Hold Area Using FREEZE/RESUME Registers section, the hold registers in Bank 3 are used to specify a
hold area instead of vertical masking. The FREEZE/RESUME
registers are used to define the hold area. The XV78HOLDEN
registers are used to specify whether XV7 and XV8 will use the
hold area or not.
Table 14. Vertical Sequence Registers (See Table 10 and Table 11 for the HBLK, CLPOB, and PBLK registers)
Register
VPATSEL
VMASK
Length
4b
2b
Range
0 to 9 Vertical Pattern Group No.
0 to 3 Mask Mode
Description
Selected Vertical Pattern Group for Each Vertical Sequence.
Enables the Masking of V1 to V6 Outputs at the Locations Specified by the
FREEZE/RESUME Registers.
0 = No Mask.
1 = Enable Freeze1/Resume1.
2 = Enable Freeze2/Resume2.
3 = Enable Both 1 and 2.
Number of Repetitions for the Vertical Pattern Group for Odd Lines. If no
odd/even alternation is required, set equal to VPATREPE.
Number of Repetitions for the Vertical Pattern Group for Even Lines. If no
odd/even alternation is required, set equal to VPATREPO.
Start Position for the Selected Vertical Pattern Group.
HD Line Length for Lines in Each Vertical Sequence. Note that 13th bit (MSB)
of the line length is located in a separate register to maintain compatibility
with AD9995.
VPATREPO
12 b
0 to 4095 Number of Repeats
VPATREPE
12 b
0 to 4095 Number of Repeats
VPATSTART
HDLEN
12 b
13 b
0 to 4095 Pixel Location
0 to 8191 Number of Pixels
HOLD1
1b
High/Low
Enable Hold Area Instead of Vertical Masking, Using FREEZE/RESUME
Registers.
XV78HOLDEN1
1b
High/Low
Enable XV7 and XV8 to Use Hold Area.
0 = Disable.
1 = Enable.
1
Located in Bank 3, vertical sequence registers for XV7 and XV8.
Rev. A | Page 27 of 96
AD9925
1
HD
2
3
XV1 TO XV6
4
4
VPAT REP 2
VPAT REP 3
VERTICAL PATTERN GROUP
CLPOB
PBLK
6
PROGRAMMABLE SETTINGS FOR EACH VERTICAL SEQUENCE:
1. START POSITION IN THE LINE OF SELECTED VERTICAL PATTERN GROUP.
2. HD LINE LENGTH.
3. VERTICAL PATTERN SELECT (VPATSEL) TO SELECT ANY VERTICAL PATTERN GROUP.
4. NUMBER OF REPETITIONS OF THE VERTICAL PATTERN GROUP (IF NEEDED).
5. START POLARITY AND TOGGLE POSITIONS FOR CLPOB AND PBLK SIGNALS.
6. MASKING POLARITY AND TOGGLE POSITIONS FOR HBLK SIGNAL.
Figure 36. Vertical Sequence Programmability
Rev. A | Page 28 of 96
04637-0-029
HBLK
5
AD9925
Complete Field: Combining Vertical Sequences
boundaries for each region. The VDLEN register specifies the
total number of lines in the field. The total number of pixels per
line (HDLEN) is specified in the vertical sequence registers, but
the HDLAST register specifies the number of pixels in the last
line of the field. Note that the 13th bit (MSB) of the last line
length is located in a separate register. During the sensor gate
(SG) line, the VPATSECOND register is used to add a second
vertical pattern group to the XV outputs.
After the vertical sequences have been created, they are combined
to create different readout fields. A field consists of up to seven
different regions, and within each region, a different vertical
sequence can be selected. Figure 37 shows how the sequence
change positions (SCP) designate the line boundary for each
region, and how the VSEQSEL registers select which vertical
sequence is used during each region. Registers to control the
XSG outputs are also included in the field registers.
The SGMASK register is used to enable or disable each individual
VSG output. There is a single bit for each XSG output, setting
the bit high will mask the output and setting it low will enable
the output. The SGPAT register assigns one of the four different
SG patterns to each VSG output. The individual SG patterns are
created separately using the SG pattern registers. The SGLINE1
register specifies which line in the field will contain the XSG
outputs. The optional SGLINE2 register allows the same SG pulses
to be repeated on a different line.
Table 15 summarizes the registers used to create the different
fields. Up to six different fields can be preprogrammed using
the field registers.
The VEQSEL registers, one for each region, select which of the
10 vertical sequences will be active during each region. The
SWEEP registers are used to enable the sweep mode during any
region. The MULTI registers are used to enable the multiplier
mode during any region. The SCP registers create the line
Table 15. Field Registers
Register
VSEQSEL
SWEEP
MULTI
SCP
VDLEN
HDLAST
Length
4b
1b
1b
12 b
12 b
13 b
Range
0 to 9 V Sequence Number
High/Low
High/Low
0 to 4095 Line Number
0 to 4095 Number of Lines
0 to 8191 Number of Pixels
VPATSECOND
4b
SGMASK
6b
0 to 9 Vertical Pattern Group
Number
High/Low, Each XSG
SGPATSEL
12 b
0 to 3 Pattern Number, Each XSG
SGLINE1
SGLINE2
12 b
12 b
0 to 4095 Line Number
0 to 4095 Line Number
SCP 2
SCP 1
Description
Selected Vertical Sequence for Each Region in the Field.
Enables Sweep Mode for Each Region, When Set High.
Enables Multiplier Mode for Each Region, When Set High.
Sequence Change Position for Each Region.
Total Number of Lines in Each Field.
Length in Pixels of the Last HD Line in Each Field. The13th bit (MSB) is located
in a separate register to maintain compatibility with the AD9995.
Selected Vertical Pattern Group for Second Pattern Applied During SG Line.
Set High to Mask Each Individual XSG Output.
XSG1 [0], XSG2 [1], XSG3 [2], XSG4 [3], XSG5 [4], XSG6 [5].
Selects the SG Pattern Number for Each XSG Output.
XSG1 [1:0], XSG2 [3:2], XSG3 [5:4], XSG4 [7:6], XSG5 [9:8], XSG6 [11:10].
Selects the Line in the Field Where the SG Signals Are Active.
Selects a Second Line in the Field to Repeat the SG Signals.
SCP 3
SCP 4
SCP 6
SCP 5
VD
REGION 0
REGION 1
REGION 2
REGION 3
REGION 4
REGION 5
REGION 6
VSEQSEL0
VSEQSEL1
VSEQSEL2
VSEQSEL3
VSEQSEL4
VSEQSEL5
VSEQSEL6
HD
XV1 TO XV6
SGLINE
FIELD SETTINGS:
1. SEQUENCE CHANGE POSITIONS (SCP1 TO SCP6) DEFINE EACH OF THE SEVEN REGIONS IN THE FIELD.
2. VSEQSEL0 TO VSEQSEL6 SELECTS THE DESIRED VERTICAL SEQUENCE (0–9) FOR EACH REGION.
3. SGLINE1 REGISTER SELECTS WHICH HD LINE IN THE FIELD WILL CONTAIN THE SENSOR GATE PULSE(S).
Figure 37. Complete Field Is Divided into Regions
Rev. A | Page 29 of 96
04637-0-030
XSG
AD9925
Generating Line Alternation for Vertical Sequence and
HBLK
During low resolution readout, some CCDs require a different
number of vertical clocks on alternate lines. The AD9925 can
support this by using the VPATREPO and VPATREPE registers.
This allows a different number of VPAT repetitions to be programmed on odd and even lines. Note that only the number of
repeats can be different in odd and even lines, but the VPAT
group remains the same.
Additionally, the HBLK signal can also be alternated for odd
and even lines. When the HBLKALT register is set high, the
HBLK TOG1 and HBLK TOG2 positions will be used on odd
lines, and the HBLK TOG3 to HBLK TOG6 positions will be
used on even lines. This allows the HBLK interval to be adjusted
on odd and even lines if needed.
Second Vertical Pattern Group during VSG Active Line
Most CCDs require additional vertical timing during the sensor
gate (SG) line. The AD9925 supports the option to output a
second vertical pattern group for XV1 to XV8 during the line
when the sensor gates XSG1 to XSG6 are active. Figure 39 shows
a typical SG line that includes two separate sets of vertical pattern
group for XV1 to XV6. The vertical pattern group at the start of
the SG line is selected in the same manner as the other regions,
using the appropriate VSEQSEL register. The second vertical
pattern group, unique to the SG line, is selected using the
VPATSECOND register, located with the field registers. The
start position of the second VPAT group uses the VPATLEN
register from the selected VPAT registers. Because the VPATLEN
register is used as the start position and not as the VPAT length,
it is not possible to program multiple repetitions for the second
VPAT group.
Figure 38 shows an example of a VPAT repetition alternation
and a HBLK alternation used together. It is also possible to use
the VPAT and HBLK alternation separately.
HD
VPATREPO = 2
VPATREPE = 5
VPATREPO = 2
XV1
XV2
XV6
TOG1
TOG2
TOG3
TOG4
TOG1
TOG2
HBLK
04637-0-031
NOTES
1. THE NUMBER OF REPEATS FOR THE VERTICAL PATTERN GROUP MAY BE ALTERNATED ON ODD AND EVEN LINES.
2. THE HBLK TOGGLE POSITIONS MAY BE ALTERNATED BETWEEN ODD AND EVEN LINES, IN ORDER TO
GENERATE DIFFERENT HBLK PATTERNS FOR ODD/EVEN LINES.
Figure 38. Odd/Even Line Alteration of VPAT Repetitions and HBLK Toggle Positions
HD
START POSITION FOR SECOND VPAT GROUP
USES VPATLEN REGISTER
XSG
XV1
XV6
SECOND VPAT GROUP
Figure 39. Example of Second VPAT Group during Sensor Gate Line
Rev. A | Page 30 of 96
04637-0-032
XV2
AD9925
Sweep Mode Operation
Multiplier Mode
The AD9925 contains an additional mode of vertical timing
operation called sweep mode. This mode is used to generate a
large number of repetitive pulses that span across multiple HD
lines. One example of where this mode is needed is at the start
of the CCD readout operation. At the end of the image exposure,
but before the image is transferred by the sensor gate pulses, the
vertical interline CCD registers should be free of all charge. This
can be accomplished by quickly shifting out any charge using a
long series of pulses from the XV outputs. Depending on the
vertical resolution of the CCD, up to two or three thousand clock
cycles will be needed to shift the charge out of each vertical CCD
line. This operation will span across multiple HD line lengths.
Normally, the AD9925 vertical timing must be contained within
one HD line length, but when sweep mode is enabled, the HD
boundaries will be ignored until the region is finished. To enable
sweep mode within any region, program the appropriate SWEEP
register to high.
To generate very wide vertical timing pulses, a vertical region
may be configured into a multiplier region. This mode uses the
vertical pattern registers in a slightly different manner. Multiplier
mode can be used to support unusual CCD timing requirements,
such as vertical pulses that are wider than a single HD line length.
Figure 40 shows an example of the sweep mode operation. The
number of vertical pulses needed depends on the vertical resolution of the CCD. The XV output signals are generated using
the vertical pattern registers (shown in Table 15). A single pulse
is created using the polarity and toggle position registers. The
number of repetitions is then programmed to match the number of vertical shifts required by the CCD. Repetitions are programmed in the vertical sequence registers using the VPATREP
registers. This produces a pulse train of the appropriate length.
Normally, the pulse train is truncated at the end of the HD line
length, but with sweep mode enabled for this region, the HD
boundaries are ignored. In Figure 40, the sweep region occupies
23 HD lines. After the sweep mode region is completed in the
next region, normal sequence operation will resume. When using
sweep mode, be sure to set the region boundaries to the appropriate lines (using the sequence change positions) to prevent the
sweep operation from overlapping the next vertical sequence.
The start polarity and toggle positions are still used in the same
manner as the standard VPAT group programming, but the
VPATLEN is used differently. Instead of using the pixel counter
(HD counter) to specify the toggle position locations (VTOG1,
2, 3) of the VPAT group, the VPATLEN is multiplied with the
VTOG position to allow very long pulses to be generated. To
calculate the exact toggle position, counted in pixels after the
start position, use the following equation:
Multiplier Mode Toggle Position = VTOG × VPATLEN
Because the VTOG register is multiplied by VPATLEN, the
resolution of the toggle position placement is reduced. If
VPATLEN = 4, then the toggle position accuracy will be reduced
to a 4-pixel step size, instead of a single pixel step size. Table 16
summarizes how the VPAT group registers are used in multiplier mode operation. In multiplier mode, the VPATREPO and
VPATREPE registers should always be programmed to the same
value as the highest toggle position.
The example shown in Figure 41 illustrates this operation. The
first toggle position is two, and the second toggle position is nine.
In nonmultiplier mode, this would cause the vertical sequence
to toggle at pixel 2 and then pixel 9 within a single HD line. However, now toggle positions are multiplied by the VTPLEN = 4, so
the first toggle occurs at pixel count = 8, and the second toggle
occurs at pixel count = 36. Sweep mode has also been enabled
to allow the toggle positions to cross the HD line boundaries.
Table 16. Multiplier MODE Register Parameters
Register
MULTI
XVPOL
XVTOG1
XVTOG2
XVTOG3
VPATLEN
VPATREP
Length
1b
1b
12 b
12 b
12 b
10 b
12 b
Range
High/Low
High/Low
0 to 4095 Pixel Location
0 to 4095 Pixel Location
0 to 4095 Pixel Location
0 to 1023 Pixels
0 to 4095
Description
High Enables Multiplier Mode.
Starting Polarity of XV Signal in Each VPAT Group.
First Toggle Position for XV Signal in Each VPAT Group.
Second Toggle Position for XV Signal in Each VPAT Group.
Third Toggle Position for XV Signal in Each VPAT Group.
Used as Multiplier Factor for Toggle Position Counter.
VPATREPE/VPATREPO Should Be Set to the Same Value as TOG2 or TOG3.
Rev. A | Page 31 of 96
AD9925
VD
SCP 1
HD
LINE 0
LINE 1
SCP 2
LINE 2
LINE 24
LINE 25
REGION 0
REGION 1: SWEEP REGION
04637-0-033
XV1 TO XV8
REGION 2
Figure 40. Example of Sweep Region for High Speed Vertical Shift
START POSITION OF VPAT GROUP IS STILL PROGRAMMED IN THE VERTICAL SEQUENCE REGISTERS
HD
5
3
5
VPATLEN
1
2
3
4
1
2
3
4
1
PIXEL
NUMBER
1
2
3
4
5
6
7
8
9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40
2
3
4
1
2
3
4
1
2
3
4
1
2
3
4
1
2
3
4
1
2
3
4
1
2
3
4
1
4
2
3
4
4
XV1 TO XV8
2
2
04637-0-034
1
MULTIPLIER MODE VERTICAL PATTERN GROUP PROPERTIES:
1. START POLARITY (ABOVE: STARTPOL = 0).
2. FIRST, SECOND, AND THIRD TOGGLE POSITIONS (ABOVE: VTOG1 = 2, VTOG2 = 9).
3. LENGTH OF VPAT COUNTER (ABOVE: VPATLEN = 4); THIS IS THE MINIMUM RESOLUTION FOR TOGGLE POSITION CHANGES.
4. TOGGLE POSITIONS OCCUR AT LOCATION EQUAL TO (VTOG × VPATLEN).
5. IF SWEEP REGION IS ENABLED, THE VERTICAL PULSES MAY ALSO CROSS THE HD BOUNDRIES, AS SHOWN ABOVE.
Figure 41. Example of Multiplier Region for Wide Vertical Pulse Timing
Vertical Sensor Gate (Shift Gate) Patterns
In an interline CCD, the sensor gates (SG) are used to transfer
the pixel charges from the light-sensitive image area into the
light-shielded vertical registers. From the light-shielded vertical
registers, the image is then clocked out line-by-line, using the
vertical transfer pulses in conjunction with the high speed horizontal clocks.
SGLINE2 registers. Additionally, any of the XSG1 to XSG6
outputs may be individually disabled by using the SGMASK
register. The individual masking allows all of the SG patterns to
be preprogrammed, and the appropriate pulses for the different
fields can be separately enabled. For maximum flexibility, the
SGPATSEL, SGMASK, and SGLINE registers are separately
programmable for each field. See the Complete Field: Combining Vertical Sequences section for more details.
Table 17 contains the summary of the SG pattern registers. The
AD9925 has six SG outputs, XSG1 to XSG6. Each of the outputs
can be assigned to one of four programmed patterns by using
the SGPATSEL registers. Each pattern is generated in a similar
manner as the vertical pattern groups, with a programmable
start polarity (SGPOL), first toggle position (SGTOG1), and
second toggle position (SGTOG2). The active line where the SG
pulses occur is programmable using the SGLINE1 and
Additionally, there is a register in Bank 1 (Addr 0x55) that overrides the SG masking in the field registers (Bank 2). The
SGMASK_OVR register allows sensor gate masking to be
changed without modifying the field register values. Setting the
SGMASKOVR_EN bit high enables the SGMASK override
function. The SGMASK_OVR register is SCK updated, so the
new SG masking values will update immediately.
Rev. A | Page 32 of 96
AD9925
Table 17. SG Pattern Registers (Also See Field Registers in Table 15)
Register
SGPOL
SGTOG1
SGTOG2
SGMASK_OVR
SGMASKOVR_EN
Length
1b
12 b
12 b
6b
1b
Range
High/Low
0 to 4095 Pixel Location
0 to 4095 Pixel Location
Six Individual Bits
Disable/Enable
Description
Sensor Gate Starting Polarity for SG Pattern 0 to 3
First Toggle Position for SG Pattern 0 to 3
Second Toggle Position for SG Pattern 0 to 3
SG Masking, Overrides the Values in the Field Registers
1: Enables SGMASK Fast Update
VD
4
HD
1
2
3
PROGRAMMABLE SETTINGS FOR EACH PATTERN:
1. START POLARITY OF PULSE.
2. FIRST TOGGLE POSITION.
3. SECOND TOGGLE POSITION.
4. ACTIVE LINE FOR XSG PULSES WITHIN THE FIELD (PROGRAMMABLE IN THE FIELD REGISTER, NOT FOR EACH PATTERN).
04637-0-035
XSG PATTERNS
Figure 42. Vertical Sensor Gate Pulse Placement
MODE Register
The MODE register is a single register that selects the field timing
of the AD9925. Typically, all the field, vertical sequence, and vertical pattern group information is programmed into the AD9925
at startup. During operation, the MODE register allows the user to
select any combination of field timing to meet the current requirements of the system. The advantage of using the MODE register in
conjunction with preprogrammed timing is that it greatly reduces
the system programming requirements during camera operation.
Only a few register writes are required when the camera operating
mode is changed, rather than having to write in all the vertical
timing information with each camera mode change.
A basic still camera application might require five different fields
of vertical timing: one for draft mode operation, one for autofocusing, and three for still image readout. All of the register
timing information for the five fields would be loaded at startup.
Then, during camera operation, the MODE register would select
which field timing would be active depending on how the camera
was being used. Table 18 shows how the MODE register data
bits are used. The three MSBs, D23 to D21, are used to specify
how many total fields will be used. Any value from 1 to 7 can be
selected using these three bits. The remaining register bits are
divided into 3-bit sections to select which of the six fields are
used and in which order. Up to seven fields may be used in a
single MODE write. The AD9925 will start with the field timing
specified by the first field bits, and on the next VD it will switch
to the timing specified by the second field bits, and so on.
After completing the total number of fields specified in Bits D23
to D21, the AD9925 will repeat by starting at the first field again.
This will continue until a new write to the MODE register occurs.
Figure 43 shows examples of the MODE register settings for
different field configurations.
Table 18. MODE Register Data Bit Breakdown (D23 = MSB)
D23 D22 D21
D20 D19 D18
D17 D16 D15
D14 D13 D12
D11 D10 D9
D8 D7 D6
D5 D4 D3
D2 D1 D0
Total Number of
Fields to Use
1 = First Field Only
7 = All 7 Fields
0 = Invalid
Seventh Field
0 = Field 0
5 = Field 5
6, 7 = Invalid
Sixth Field
0 = Field 0
5 = Field 5
6, 7 = Invalid
Fifth Field
0 = Field 0
5 = Field 5
6, 7 = Invalid
Fourth Field
0 = Field 0
5 = Field 5
6, 7 = Invalid
Third Field
0 = Field 0
5 = Field 5
6, 7 = Invalid
Second Field
0 = Field 0
5 = Field 5
6, 7 = Invalid
First Field
0 = Field 0
5 = Field 5
6, 7 = Invalid
Rev. A | Page 33 of 96
AD9925
EXAMPLE 1:
TOTAL FIELDS = 3, FIRST FIELD = FIELD 0, SECOND FIELD = FIELD 1, THIRD FIELD = FIELD 2
MODE REGISTER CONTENTS = 0x60 0088
FIELD 0
FIELD 1
FIELD 2
EXAMPLE 2:
TOTAL FIELDS = 2, FIRST FIELD = FIELD 3, SECOND FIELD = FIELD 4
MODE REGISTER CONTENTS = 0x40 0023
FIELD 3
FIELD 4
EXAMPLE 3:
TOTAL FIELDS = 4, FIRST FIELD = FIELD 5, SECOND FIELD = FIELD 1, THIRD FIELD = FIELD 4, FOURTH FIELD = FIELD 2
MODE REGISTER CONTENTS = 0x80 050D
FIELD 1
FIELD 2
FIELD 4
04637-0-036
FIELD 5
Figure 43. Using the MODE Register to Select Field Timing
VERTICAL TIMING EXAMPLE
To better understand how the AD9925 vertical timing generation
is used, consider CCD timing chart in Figure 44. This particular
example illustrates a CCD using a general 3-field readout technique. As described in the previous field section, each readout
field should be divided into separate regions to perform each
step of the readout. The sequence change positions (SCP)
determine the line boundaries for each region, and then the
VSEQSEL registers assign a particular vertical sequence to each
region. The vertical sequences contain the specific timing
information required in each region: XV1 to XV6 pulses (using
VPAT groups), HBLK/CLPOB timing, and XSG patterns for the
SG active lines.
This particular timing example requires four regions for each of
the three fields, labeled Region 0, Region 1, Region 2, and
Region 3. Because the AD9925 allows up to six individual fields
to be programmed, the Field 0, Field 1, and Field 2 registers can
be used to meet the requirements of this timing example. The
four regions for each field are very similar in this example, but
the individual registers for each field allow flexibility to accommodate other timing charts.
Region 0 is a high speed vertical shift region. Sweep mode may
be used to generate this timing operation, with the desired
number of high speed vertical pulses needed to clear any charge
from the CCD’s vertical registers. Region 1 consists of only two
lines and, like Region 3, uses standard single line vertical shift
timing. Region 2 is the sensor gate line, where the VSG pulses
transfer the image into the vertical CCD registers. This region
may require the use of the second vertical pattern group for the
SG active line.
In summary, four regions are required in each of the three
fields. The timing for Region 1 and Region 3 is essentially the
same, reducing the complexity of the register programming.
However, other registers will need to be used during the actual
readout operation, such as the MODE register, shutter control
registers (TRIGGER, SUBCK, VSUB, MSHUT, and STROBE),
and the AFE gain register. These registers will be explained in
other examples.
Important Note about Signal Polarities
When programming the AD9925 to generate the XV1 to XV8,
XSG1 to XSG6, and SUBCK signals, it is important to note that
the vertical driver circuit will invert these signals. Carefully
check the required timing signals needed at the output of the
vertical driver circuit and adjust the polarities of the XV signals
accordingly.
Rev. A | Page 34 of 96
Rev. A | Page 35 of 96
Figure 44. CCD Timing Example—Dividing Each Field into Regions
04637-0-037
CCD
OUT
VSUB
MSHUT
SUBCK
V6
V5
V4
V3
V2
V1
HD
VD
OPEN
REGION 0
N–5
N–2
REGION 3
1
4
7
10
13
16
REGION 2
FIELD 0
REGION 1
FIRST FIELD READOUT
CLOSED
EXPOSURE (tEXP)
REGION 0
N–4
N–1
REGION 2
REGION 3
2
5
8
11
14
17
20
FIELD 1
REGION 1
SECOND FIELD READOUT
REGION 0
N–3
N
REGION 2
REGION 3
3
6
9
12
15
18
21
FIELD 2
REGION 1
THIRD FIELD READOUT
OPEN
AD9925
AD9925
SHUTTER TIMING CONTROL
High Precision Shutter Operation
The CCD image exposure time is controlled by the substrate
clock signal (SUBCK), which pulses the CCD substrate to clear
out accumulated charge. The AD9925 supports three types of
electronic shuttering: normal, high precision, and low speed.
Along with the SUBCK pulse placement, the AD9925 can accommodate different readout configurations to further suppress
the SUBCK pulses during multiple field readouts. The AD9925
also provides programmable outputs to control an external mechanical shutter (MSHUT), a strobe/flash (STROBE), and the
CCD bias select signal (VSUB).
High precision shuttering is used in the same manner as normal
shuttering, but it uses an additional register to control the last
SUBCK pulse. In this mode, the SUBCK still pulses once per
line, but the last SUBCK in the field will have an additional
SUBCK pulse, the location of which is determined by the
SUBCK2TOG register, as shown in Figure 46. Finer resolution
of the exposure time is possible using this mode. Leaving the
SUBCK2TOG register set to its maximum value (0xFF FFFF)
will disable the last SUBCK pulse (default setting).
Normal Shutter Operation
By default, the AD9925 always operates in the normal shutter
configuration, in which the SUBCK signal pulses in every VD
field (see Figure 45). The SUBCK pulse occurs once per line,
and the total number of repetitions within the field will determine the length of the exposure time. The SUBCK pulse polarity and toggle positions within a line are programmable using
the SUBCKPOL and SUBCK1TOG registers (see Table 19). The
number of SUBCK pulses per field is programmed in the
SUBCKNUM register (Addr 0x63).
Normal and high precision shutter operations are used when
the exposure time is less than one field long. For exposure times
longer than one field interval, low speed shutter operation is
used. The AD9925 uses a separate exposure counter to achieve
long exposure times. The number of fields for the low speed
shutter operation is specified in the EXPOSURE register
(Addr 0x62). As shown in Figure 47, this shutter mode will
suppress the SUBCK and VSG outputs for up to 4095 fields (VD
periods). The VD and HD outputs may be suppressed during the
exposure period by programming the VDHDOFF register to 1.
As shown in Figure 45, the SUBCK pulses will always begin
in the line following the SG active line, which is specified
in the SGACTLINE registers for each field. The SUBCKPOL,
SUBCK1TOG, SUBCK2TOG, SUBCKNUM, and SUBCKSUPPRESS registers are updated at the start of the line after the sensor
gate line, as described in the Updating New Register Values section.
To generate a low speed shutter operation, it is necessary to
trigger the start of the long exposure by writing to the TRIGGER
Register Bit D3. When this bit is set high, at the next VD edge,
the AD9925 will begin an exposure operation. If a value greater
than 0 is specified in the EXPOSURE register, AD9925 will
suppress the SUBCK output on subsequent fields.
Low Speed Shutter Operation
If the exposure is generated using the TRIGGER register and
the EXPOSURE register is set to 0, then the behavior of the
SUBCK will not be any different than that of normal shutter or
high precision shutter operations, in which the TRIGGER register is not used.
VD
HD
XSG
tEXP
tEXP
SUBCK PROGRAMMABLE SETTINGS:
1. PULSE POLARITY USING THE SUBCKPOL REGISTER.
2. NUMBER OF PULSES WITHIN THE FIELD USING THE SUBCKNUM REGISTER (SUBNUM = 3 IN THE ABOVE EXAMPLE).
3. PIXEL LOCATION OF PULSE WITHIN THE LINE AND PULSE WIDTH PROGRAMMED USING SUBCK1 TOGGLE POSITION REGISTER.
Figure 45. Normal Shutter Mode
Rev. A | Page 36 of 96
04637-0-038
SUBCK
AD9925
VD
HD
XSG
tEXP
tEXP
04637-0-039
SUBCK
NOTES
1. SECOND SUBCK PULSE IS ADDED IN THE LAST SUBCK LINE.
2. LOCATION OF SECOND PULSE IS FULLY PROGRAMMABLE USING THE SUBCK2 TOGGLE POSITION REGISTER.
Figure 46. High Precision Shutter Mode
TRIGGER
EXPOSURE
VD
XSG
tEXP
NOTES
1. SUBCK MAY BE SUPPRESSED FOR MULTIPLE FIELDS BY PROGRAMMING THE EXPOSURE REGISTER GREATER THAN ZERO.
2. ABOVE EXAMPLE USES EXPOSURE = 1.
3. TRIGGER REGISTER MUST ALSO BE USED TO START THE LOW SPEED EXPOSURE.
4. VD/HD OUTPUTS MAY ALSO BE SUPPRESSED USING THE VDHDOFF REGISTER = 1.
04637-0-040
SUBCK
Figure 47. Low Speed Shutter Mode Using EXPOSURE Register
Table 19. Shutter MODE Register Parameters
Register
TRIGGER
Length
5b
Range
On/Off for Five Signals
READOUT
EXPOSURE
3b
12 b
0 to 7 Number of Fields
0 to 4095 Number of Fields
VDHDOFF
SUBCKPOL1
SUBCK1TOG1
SUBCK2TOG1
SUBCKNUM1
SUBCKSUPPRESS1
1b
1b
24 b
24 b
12 b
12 b
On/Off
High/Low
0 to 4095 Pixel Locations
0 to 4095 Pixel Locations
1 to 4095 Number of Pulses
0 to 4095 Number of Pulses
1
Description
Trigger for VSUB [0], MSHUT [1], STROBE [2],
Exposure [3], and Readout Start [4]
Number of Fields to Suppress SUBCK after Exposure
Number of Fields to Suppress to SUBCK and VSG
during Exposure Time (Low Speed Shutter)
Disable VD/HD Output during Exposure (1 = On, 0 = Off)
SUBCK Start Polarity for SUBCK1 and SUBCK2
Toggle Positions for First SUBCK Pulse (Normal Shutter)
Toggle Positions for Second SUBCK Pulse in Last Line (High Precision)
Total Number of SUBCKs per Field, at 1 Pulse per Line
Number of Lines to Further Suppress SUBCK after the VSG Line
Register is not VD updated, but is updated at the start of the line after the sensor gate line.
Rev. A | Page 37 of 96
AD9925
SUBCK Suppression
Normally, the SUBCKs will begin to pulse on the line following
the sensor gate line (VSG). With some CCDs, the SUBCK pulse
needs to be suppressed for one or more lines following the VSG
line. The SUBCKSUPPRESS register allows for the suppression
of the SUBCK pulses for lines following the VSG line.
Readout after Exposure
After the exposure, the readout of the CCD data occurs, beginning with the sensor gate (VSG) operation. By default, the
AD9925 is generating the VSG pulses in every field. In the case
where only a single exposure and a single readout frame is
needed, such as the CCD’s preview mode, the VSG and SUBCK
pulses can operate in every field.
However, in many cases, during readout, the SUBCK output
needs to be further suppressed until the readout is completed.
The READOUT register specifies the number of additional
fields after the exposure to continue the suppression of SUBCK.
READOUT can be programmed for zero to seven additional
fields and should be preprogrammed at startup, not at the same
time as the exposure write. A typical interlaced CCD frame
readout mode will generally require two additional fields of
SUBCK suppression (READOUT = 2). A 3-field, 6-phase CCD
will require three additional fields of SUBCK suppression after
the readout begins (READOUT = 3).
If the SUBCK output is required to start back up during the last
field of readout, simply program the READOUT register to one
less than the total number of CCD readout fields.
Like the exposure operation, the readout operation must be
triggered using the TRIGGER register.
Using the TRIGGER Register
As described above, by default, the AD9925 will output the
SUBCK and VSG signals on every field. This works well for
continuous single-field exposure and readout operations, such
as the CCD’s live preview mode. However, if the CCD requires a
longer exposure time, or if multiple readout fields are needed,
the TRIGGER register needs to initiate specific exposure and
readout sequences.
Typically, the exposure and readout bits in the TRIGGER register are used together. This will initiate a complete exposure-plus
readout operation. Once the exposure has been completed, the
readout will automatically occur. The values in the EXPOSURE
and READOUT registers will determine the length of each
operation.
It is possible to independently trigger the readout operation
without triggering the exposure operation. This will cause the
readout to occur at the next VD, and the SUBCK output will be
suppressed according to the value of the READOUT register.
The TRIGGER register is also used to control the STROBE,
MSHUT, and VSUB signal transitions. Each of these signals is
individually controlled, although they will be dependent on the
triggering of the exposure and readout operation.
See Figure 49 for a complete example of triggering the exposure
and readout operations.
VSUB Control
The CCD readout bias (VSUB) can be programmed to accommodate different CCDs. Figure 48 shows two different modes
that are available. In Mode 0, VSUB goes active during the field
of the last SUBCK when the exposure begins. The on position
(rising edge in Figure 48) is programmable to any line within
the field. VSUB will remain active until the end of the image
readout. In Mode 1, the VSUB is not activated until the start of
the readout.
An additional function called VSUB keep-on is also available.
When this bit is set high, the VSUB output will remain on (active)
even after the readout has finished. To disable the VSUB, set
this bit back to low.
MSHUT and STROBE Control
MSHUT and STROBE operation is shown in Figure 49, Figure
50, and Figure 51. Table 20 shows the registers parameters for
controlling the MSHUT and STROBE outputs. The MSHUT
output is switched on with the MSHUTON registers, and it will
remain on until the location specified in the MSHUTOFF is
reached. The location of MSHUTOFF is fully programmable to
anywhere within the exposure period, using the FD (field), LN
(line), and PX (pixel) registers. The STROBE pulse is defined by
the on and off positions. STROBON_FD is the field in which
the STROBE is turned on, measured from the field containing
the last SUBCK before exposure begins. The STROBON_ LN
PX register gives the line and pixel positions with respect to
STROBON_FD. The STROBE off position is programmable to
any field, line, and pixel location with respect to the field of the
last SUBCK.
Rev. A | Page 38 of 96
AD9925
TRIGGER
VSUB
VD
XSG
tEXP
READOUT
SUBCK
4
2
MODE 0
MODE 1
3
VSUB OPERATION:
1. ACTIVE POLARITY IS POLARITY (ABOVE EXAMPLE IS VSUB ACTIVE HIGH).
2. ON-POSITION IS PROGRAMMABLE, MODE 0 TURNS ON AT THE START OF EXPOSURE, MODE 1 TURNS ON AT THE START OF READOUT.
3. OFF-POSITION OCCURS AT END OF READOUT.
4. OPTIONAL VSUB KEEP-ON MODE WILL LEAVE THE VSUB ACTIVE AT THE END OF READOUT.
04637-0-041
2
VSUB 1
Figure 48. VSUB Programmability
TRIGGER
EXPOSURE
AND MSHUT
VD
XSG
tEXP
SUBCK
2
3
MSHUT PROGRAMMABLE SETTINGS:
1. ACTIVE POLARITY.
2. ON-POSITION IS VD UPDATED AND MAY BE SWITCHED ON AT ANY TIME.
3. OFF-POSITION CAN BE PROGRAMMED ANYWHERE FROM THE FIELD OF LAST SUBCK UNTIL THE FIELD BEFORE READOUT.
04637-0-042
MSHUT 1
Figure 49. MSHUT Output Programmability
TRIGGER Register Limitations
Although the TRIGGER register can be used to perform a complete exposure and readout operation, there are limitations on
its use.
Once an exposure-plus readout operation has been triggered,
another exposure/readout operation cannot be triggered right
away. There must be at least one idle field (VD intervals) before
the next exposure/readout can be triggered. The same limitation applies to the triggering of the MSHUT signal. There
must be at least one idle field after the completion of the
MSHUT OFF operation before another MSHUT OFF operation can be programmed.
The VSUB trigger requires two idle fields between exposure/readout operations in order to ensure proper VSUB on/off
triggering. If the VSUB signal is not required to be turned on
and off in between each successive exposure/readout operation,
then this limitation can be ignored. Using the VSUB keep-on
mode is useful when successive exposure/readout operations
are required.
Rev. A | Page 39 of 96
AD9925
TRIGGER
EXPOSURE
AND STROBE
VD
XSG
tEXP
SUBCK
2
3
STROBE PROGRAMMABLE SETTINGS:
1. ACTIVE POLARITY.
2. ON-POSITION IS PROGRAMMABLE IN ANY FIELD DURING THE EXPOSURE TIME (WITH RESPECT TO THE FIELD CONTAINING THE LAST SUBCK).
3. OFF-POSITION IS PROGRAMMABLE IN ANY FIELD DURING THE EXPOSURE TIME.
04637-0-043
STROBE 1
Figure 50. STROBE Output Programmability
Table 20. VSUB, MSHUT, and STROBE Register Parameters
Register
VSUBMODE[0]
VSUBMODE[1]
VSUBON[11:0]
VSUBON[12]
MSHUTPOL[0]
MSHUTPOL[1]
MSHUTON
MSHUTOFF_FD
MSHUTOFF_LNPX
STROBPOL
STROBON_FD
STROBON_LNPX
STROBOFF_FD
STROBOFF_LNPX
Length
1b
1b
12 b
1b
1b
1b
24 b
12 b
24 b
1b
12 b
24 b
12 b
24 b
Range
High/Low
High/Low
0 to 4095 Line Location
High/Low
High/Low
On/Off
0 to 4095 Line/Pixel Location
0 to 4095 Field Location
0 to 4095 Line/Pixel Location
High/Low
0 to 4095 Field Location
0 to 4095 Line/Pixel Location
0 to 4095 Field Location
0 to 4095 Line/Pixel Location
Description
VSUB Mode (0 = Mode 0, 1 = Mode 1) (See Figure 44).
VSUB Keep-On Mode. VSUB will stay active after readout when set high.
VSUB On Position. Active starting in any line of field.
VSUB Active Polarity.
MSHUT Active Polarity.
MSHUT Manual Enable (1 = Active or Open).
MSHUT On Position Line [11:0] and Pixel [23:12] Location.
Field Location to Switch Off MSHUT (Inactive or Closed).
Line/Pixel Position to Switch Off MSHUT (Inactive or Closed).
STROBE Active Polarity.
STROBE ON Field Location, with Respect to Last SUBCK Field.
STROBE ON Line/Pixel Position.
STROBE OFF Field Location, with Respect to Last SUBCK Field.
STROBE OFF Line/Pixel Position.
Rev. A | Page 40 of 96
Rev. A | Page 41 of 96
04637-0-044
DRAFT IMAGE
DRAFT IMAGE
3
4
CCD
OUT
2
MODE 0
1
VSUB
MECHANICAL
SHUTTER
MSHUT
STROBE
SUBCK
XSG
VD
SERIAL
WRITES
tEXP
OPEN
5
MODE 1
STILL IMAGE FIRST FIELD
CLOSED
6
7
STILL IMAGE SECOND FIELD STILL IMAGE THIRD FIELD
STILL IMAGE READOUT
8
9
10
10
10
10
OPEN
DRAFT IMAGE
AD9925
EXAMPLE OF EXPOSURE AND READOUT OF INTERLACED FRAME
Figure 51. Example of Exposure and Still Image Readout Using Shutter Signals and MODE Register
AD9925
Refer to Figure 51 for each step:
1.
Write to the READOUT register (Addr x61) to specify the
number of fields to further suppress SUBCK while the
CCD data is readout. In this example, READOUT = 3.
Write to the EXPOSURE register (Addr x62) to specify the
number of fields to suppress SUBCK and VSG outputs during exposure. In this example, EXPOSURE = 1.
Write to the TRIGGER register (Addr x60) to enable the
STROBE, MSHUT, and VSUB signals and to start the exposure/readout operation. To trigger these events (as in
Figure 56), set the register TRIGGER = 31. Readout will
automatically occur after the exposure period is finished.
Write to the MODE register (x1B) to configure the next
five fields. The first two fields during exposure are the
same as the current draft mode fields, and the following
three fields are the still frame readout fields. The registers
for the draft mode field and the three readout fields have
already been programmed.
2.
The VD/HD falling edge will update the serial writes from 1.
3.
If VSUB mode = 0 (Addr x67), VSUB output will turn on at
the line specified in the VSUBON register (Addr x68).
4.
STROBE output turns on and off at the location specified
in the STROBEON and STROBEOFF registers (Addr x6E
to x71).
5.
MSHUT output turns off at the location specified in the
MSHUTOFF registers (Addr x6B and x6C).
6.
The next VD falling edge will automatically start the first
readout field.
7.
The next VD falling edge will automatically start the second readout field.
8.
The next VD falling edge will automatically start the third
readout field.
9.
Write to the MODE register to reconfigure the single draft
mode field timing. Write to the MSHUTON register
(Addr x6A) to open the mechanical shutter.
10. VD/HD falling edge will update the serial writes from 9.
VSG outputs return to draft mode timing.
SUBCK output resumes operation.
MSHUT output returns to the on position (active or open).
VSUB output returns to the off position (inactive).
Rev. A | Page 42 of 96
AD9925
The AD9925 contains an additional signal that may be used in
conjunction with shutter operation or general system operation.
The FG_TRIG signal is an internally generated pulse that can be
output on the VSUB or SYNC pins for system use or combined
with the VSUB registers to create a four-toggle VSUB signal.
The FG_TRIG signal is generated using the start polarity and
first and second toggle position registers, programmable with
line and pixel resolution. The field placement of the FG_TRIG
pulse is matched to the field count specified by the MODE register operation. The FG_TRIGEN register contains a 3-bit value
to specify which field count will contain the FG_TRIG pulse.
Figure 53 shows how the FG_TRIG pulse is generated using
these registers.
One final application for the FG_TRIG signal is to combine it
with the existing VSUB signal to generate additional toggle
positions. By setting the SHUT_EXTRA Bit 8 to a 1, the VSUB
toggles and FG_TRIG toggles are XOR’d together and sent to the
VSUB output. Figure 52 and Figure 54 show this application in
more detail.
FG_TRIG
INTERNAL
1
XOR
1
2:1
0
2:1
VSUB
INTERNAL
VSUB
OUTPUT
0
SHUT_EXTRA[3]
SHUT_EXTRA[8]
04637-0-074
FG_TRIG OPERATION
Figure 52. Combining the Internal FG_TRIG and Internal VSUB Signals
After the FG_TRIG signal is specified, it is enabled using Bit 3
of the FG_TRIGEN register. By default, the FG_TRIG will be
mapped to the SYNC output, as long as the SYNC pin is configured as an output (SYNCENABLE = 1). Alternatively, the
FG_TRIG pulse may be mapped to the VSUB output by
writing a 1 to the SHUT_EXTRA Register Bit 3.
Table 21. FG_TRIG Operation Registers
Register
SYNCENABLE
VSUBON
Address
0x12
0x68
Bit Width
[0]
[12:0]
SHUT_EXTRA
0xE7
[8:0]
FG_TRIGEN
0xEB
[3:0]
FG_TRIGPOL
FG_TRIGLINE1
FG_TRIGPIX1
FG_TRIGLINE2
FG_TRIGPIX2
0xF2
0xF3
0xF4
0xF5
0xF6
[0]
[11:0]
[12:0]
[11:0]
[12:0]
Description
1: Configures SYNC Pin as an Output. By default, the FG_TRIG signal outputs on the SYNC pin.
Controls VSUB On Position and Polarity. When SHUT_Extra [8] = 1, FG_TRIG toggles are combined
with VSUB signal.
Selects Whether FG_TRIG Signal Is Used with VSUB.
[2:0] Set to 0.
[3] Set = 1 to send FG_TRIG signal to VSUB pin.
[7:4] Set to 0.
[8] Set = 1 to combine FG_TRIG and VSUB signals.
FG_TRIG Enable.
[2:0] Selects field count for pulse (based on mode field counter).
[3] Set = 1 to enable FG_TRIG signal output.
FG_TRIG Start Polarity.
FG_TRIG First Toggle Position, Line Location.
FG_TRIG First Toggle Position, Pixel Location.
FG_TRIG Second Toggle Position, Line Location.
FG_TRIG Second Toggle Position, Pixel Location.
Rev. A | Page 43 of 96
AD9925
VD
MODE REGISTER
FIELD COUNT
FIELD 0
FIELD 1
FIELD 2
4
FIELD 1
4
1
04637-0-066
2
3
FG_TRIG PROGRAMMABLE SETTINGS:
1. ACTIVE POLARITY.
2. FIRST TOGGLE POSITION, LINE AND PIXEL LOCATION.
3. SECOND TOGGLE POSITION, LINE AND PIXEL LOCATION.
4. FIELD PLACEMENT BASED ON MODE REGISTER FIELD COUNT.
Figure 53. Generating the FG_TRIG Signal
VD
VSUB
INTERNAL
FG_TRIG
INTERNAL
VSUB OUT
SHUT_XTRA[8] = 0
04637-0-067
FG_TRIG
FIELD 0
VSUB OUT
SHUT_XTRA[8] = 1
Figure 54. Combining FG_TRIG and VSUB to Create Four Toggle Positions for VSUB Output
Rev. A | Page 44 of 96
AD9925
1.0µF 1.0µF
REFB REFT
1.0V
DC RESTORE
INTERNAL
VREF
SHP
FIXED
DELAY
CLI
1.3V
0.1µF
2.0V
DOUT PHASE
2V FULL SCALE
6dB ~ 42dB
CCDIN
12-BIT
ADC
VGA
CDS
DCLK
0
DOUT
DLY
SHD
1
DCLK
MODE
OUTPUT
DATA
LATCH
12
DOUT
OPTICAL BLACK
CLAMP
VGA GAIN
REGISTER
DAC
CLPOB PBLK
DIGITAL
FILTER
8
CLI
PRECISION
TIMING
GENERATION
CLPOB
CLAMP LEVEL
REGISTER
PBLK
V-H
TIMING
GENERATION
AD9925
04637-A-002
SHP
DOUT
SHD PHASE
Figure 55. Analog Front End Functional Block Diagram
Variable Gain Amplifier
ANALOG FRONT END DESCRIPTION
AND OPERATION
The VGA stage provides a gain range of 6 dB to 42 dB, programmable with 10-bit resolution through the serial digital interface.
The minimum gain of 6 dB is needed to match a 1 V input signal
with the ADC full-scale range of 2 V. When compared to 1 V fullscale systems, the equivalent gain range is 0 dB to 36 dB.
The AD9925 signal processing chain is shown in Figure 55.
Each processing step is essential in achieving a high quality
image from the raw CCD pixel data.
DC Restore
To reduce the large dc offset of the CCD output signal, a dcrestore circuit is used with an external 0.1 µF series coupling
capacitor. This restores the dc level of the CCD signal to approximately 1.3 V, which allows it to be compatible with the
3 V supply voltage of the AD9925.
The VGA gain curve follows a linear-in-dB characteristic. The
exact VGA gain can be calculated for any gain register value by
using the equation
Correlated Double Sampler
where the Code range is 0 to 1023.
42
36
VGA GAIN (dB)
The CDS circuit samples each CCD pixel twice to extract the
video information and reject the low frequency noise. The timing
shown in Figure 19 illustrates how the two internally generated
CDS clocks, SHP and SHD, are used to sample the reference level
and data level of the CCD signal, respectively. The placement of
the SHP and SHD sampling edges is determined by setting the
SAMPCONTROL register located at Addr 0x36. Placement of
these two clock signals is critical in achieving the best performance from the CCD.
Gain (dB) = (0.0351 × Code) + 6 dB
30
24
18
6
0
127
255
383
511
639
767
VGA GAIN REGISTER CODE
Figure 56. VGA Gain Curve
Rev. A | Page 45 of 96
895
1023
04637-0-046
12
AD9925
ADC
Digital Data Outputs
The AD9925 uses high performance ADC architecture, optimized for high speed and low power. Differential nonlinearity
(DNL) performance is typically better than 0.5 LSB. The ADC
uses a 2 V input range. See Figure 10, Figure 12, and Figure 13
for typical linearity and noise performance plots for the
AD9925.
The AD9925 digital output data is latched using the DOUT
PHASE register value, as shown in Figure 55. Output data timing is shown in Figure 21 and Figure 22. It is also possible to
leave the output latches transparent, so that the data outputs are
valid immediately from the ADC. Programming the AFE
CONTROL Register Bit D4 to a 1 will set the output latches
transparent. The data outputs can also be disabled (three stated)
by setting the AFE CONTROL Register Bit D3 to a 1.
Optical Black Clamp
The optical black clamp loop is used to remove residual offsets
in the signal chain and to track low frequency variations in the
CCD’s black level. During the optical black (shielded) pixel inter val on each line, the ADC output is compared with a fixed
black level reference, selected by the user in the clamp level
register. The value can be programmed between 0 LSB and
255 LSB in 256 steps. The resulting error signal is filtered to
reduce noise, and the correction value is applied to the ADC
input through a DAC. Normally, the optical black clamp loop is
turned on once per horizontal line, but this loop can be updated
more slowly to suit a particular application. If external digital
clamping is used during the postprocessing, the AD9925 optical
black clamping may be disabled using Bit D2 in the OPRMODE
register. When the loop is disabled, the clamp level register may
still be used to provide programmable offset adjustment.
The CLPOB pulse should be placed during the CCD’s optical
black pixels. It is recommended that the CLPOB pulse duration
be at least 20 pixels wide. Shorter pulse widths may be used, but
the ability to track low frequency variations in the black level
will be reduced. See the Horizontal Clamping and Blanking
section for timing examples.
The switching of the data outputs can couple noise back to the
analog signal path. To minimize any switching noise, it is recommended that the DOUT PHASE register be set to the same
edge as the SHP sampling location, or up to 12 edges after the
SHP sampling location. Other settings can produce good results,
but experimentation is necessary. It is recommended that the
DOUT PHASE location not occur between the SHD sampling
location and 12 edges after the SHD location. For example, if
SHDLOC = 0, then DOUT PHASE should be set to an edge
location of 12 or greater. If adjustable phase is not required for
the data outputs, the output latch can be left transparent using
register 0x03, Bit [4].
The data output coding is normally straight binary, but the
coding may be changed to gray coding by setting the AFE
CONTROL Register Bit D5 to a 1.
Rev. A | Page 46 of 96
AD9925
Table 22 to Table 32 describe the output polarities for these
signals vs. their input levels. Refer to these tables when determining the register settings for the desired output levels.
Figure 58 to Figure 64 show graphically the relationship between
the polarities of the XV and XSG signals and the inverted vertical driver output signals.
VERTICAL DRIVER SIGNAL CONFIGURATION
As shown in Figure 57, XV1 to XV8, XSG1 to XSG6, and
XSUBCK are outputs from the internal AD9925 timing generator, while V1 to V8 and SUBCK are the resulting outputs from
the AD9925 vertical driver. The vertical driver performs the
mixing of the XV and XSG pulses and amplifies them to the
high voltages required for driving the CCD. Additionally, the
vertical driver outputs are inverted from the internal XV, XSG,
and SUBCK polarities configured by the AD9925 registers.
AD9925
VERTICAL DRIVER
+3V
+15V, –7.5V
XV1
B8
V1
XSG1
XV2
G11
V2
XSG6
XSG2
B9
V3A
XV3
3-LEVEL OUTPUTS
C9
V3B
XSG3
INTERNAL
TIMING
GENERATOR
XSG4
D9
V5A
XV5
E9
V5B
XSG5
XV4
G10
XV6
H10
XV7
K10
XV8
J9
XSUBCK
J8
Figure 57. AD9925 Internal V-Driver Input Signals
Rev. A | Page 47 of 96
V4
V6
2-LEVEL OUTPUTS
V7
SUBCK
04637-0-047
V8
AD9925
Table 22. V1 Output Polarity
XV1
L
L
H
H
V-Driver Input
XSG1
L
H
L
H
Table 27. V5A Output Polarity
V1 Output
VH
VM
VL
VL
Table 23. V2 Output Polarity
XV2
L
L
H
H
V-Driver Input
XSG6
L
H
L
H
XV3
L
L
H
H
V2 Output
VH
VM
VL
VL
XV3
L
L
H
H
V3A Output
VH
VM
VL
VL
V3B Output
VH
VM
VL
VL
Table 26. V4 Output Polarity
V-Driver Input
XV4
L
H
V5A Output
VH
VM
VL
VL
XV5
L
L
H
H
V-Driver Input
XSG5
L
H
L
H
V5B Output
VH
VM
VL
VL
Table 29. V6 Output Polarity
Table 25. V3B Output Polarity
V-Driver Input
XSG3
L
H
L
H
V-Driver Input
XSG4
L
H
L
H
Table 28. V5B Output Polarity
Table 24. V3A Output Polarity
V-Driver Input
XSG2
L
H
L
H
XV5
L
L
H
H
V4 Output
VM
VL
V-Driver Input
XV6
L
H
V6 Output
VM
VL
Table 30. V7 Output Polarity
V-Driver Input
XV7
L
H
V7 Output
VM
VL
Table 31. V8 Output Polarity
V-Driver Input
XV8
L
H
V8 Output
VM
VL
Table 32. SUBCK Output Polarity
V-Driver Input
XSUBCK
L
H
Rev. A | Page 48 of 96
SUBCK Output
VH
VL
AD9925
XV1
XSG1
V1
04637-0-048
VH
VM
VL
Figure 58. XV1, XSG1, and V1 Output Polarities
XV2
XSG6
V2
04637-0-049
VH
VM
VL
Figure 59. XV2, XSG6, and V2 Output Polarities
XV3
XSG2
VH
VM
04637-0-050
V3A
VL
Figure 60. XV3, XSG2, and V3A Output Polarities
XV3
XSG3
VH
VM
04637-0-051
V3B
VL
Figure 61. XV3, XSG3, and V3B Output Polarities
Rev. A | Page 49 of 96
AD9925
XV5
XSG4
VH
VM
04637-0-052
V5A
VL
Figure 62. XV5, XSG4, and V5A Output Polarities
XV5
XSG5
VH
VM
04637-0-053
V5B
VL
Figure 63. XV5, XSG5, and V5B Output Polarities
V4, V6,
V7, V8
04637-0-054
XV4, XV6,
XV7, XV8
VM
VL
Figure 64. XV4, XV6, XV7, XV8 and V4, V6, V7, V8 Output Polarities
Rev. A | Page 50 of 96
AD9925
POWER-UP AND SYNCHRONIZATION
Vertical Driver Power Supply Sequencing
The recommended Power-Up and Power-Down sequences are
shown in Figure 65 and Figure 66, respectively. As shown, the
VM1 and VM2 voltage levels should never exceed the VH1 and
VH2 voltage levels during power-up or power-down. Excessive
current will result if this requirement is not met due to a PN
junction diode turning on between the VM1/VM2 and VH
supply pins.
VH1 = VH2 = 12.0V TO 15.0V
VDVDD = DVDD = DRVDD = HVDD = RGVDD = TCVDD = AVDD = 3.0V
1
2
0V
VL = –7.5V
SAME TIME AS VM AND VH; LATER OR EARLIER IS OK, BUT NOT BEFORE VDD REACHES 3.0V.
Figure 65. Power-Up Sequence
VH1 = VH2
VDVDD = DVDD = DRVDD = HVDD = RGVDD = TCVDD = AVDD = 3V
1
2
0V
VM1 = VM2
SAME TIME AS VM AND VH OR EARLIER, BUT NOT AFTER VDD.
Figure 66. Power-Down Sequence
Rev. A | Page 51 of 96
04637-0-056
VL
04637-0-055
VM1 = VM2 = –1.0V TO –0.5V
AD9925
VH1 = VH2 = 15.0V
VDVDD = DVDD = DRVDD = HVDD = RGVDD = TCVDD = AVDD = 3V
POWER
SUPPLIES
0V
1
4
VL = –7.5V
CLI
(INPUT)
2
3
5
6
7
8
9
10
11
SERIAL
WRITES
12
SYNC
(INPUT)
tSYNC
1V
VD
(OUTPUT)
1ST FIELD
1H
HD
(OUTPUT)
H2/H4
H1/H3, RG, DCLK
CLOCKS ACTIVE WHEN OUT_CONTROL
REGISTER IS UPDATED AT VD/HD EDGE
04637-0-069
DIGITAL
OUTPUTS
Figure 67. Recommended Power-Up Sequence and Synchronization, Master Mode
Recommended Power-Up Sequence for Master Mode
When the AD9925 is powered up, the following sequence is
recommended (refer to Figure 67 for each step). Note that a
SYNC signal is required for master mode operation. If an external SYNC pulse is not available, it is also possible to generate an
internal SYNC pulse by writing to the SYNCPOL register, as
described in the next section.
1.
Turn on power supplies for the AD9925 and apply master
clock CLI.
2.
Reset the internal AD9925 registers by writing a 1 to the
SW_RESET register (Addr 0x10 in Bank 1).
3.
Write to the standby mode polarity registers 0x0A to 0x0D
to set the proper polarities for the V-driver inputs, in order
to avoid damage to the CCD. See Table 35 for settings.
4.
The V-driver supplies, VH and VL, can then be powered up
anytime after completing Step 3 to set the proper polarities.
5.
By default, the AD9925 is in standby 3 mode. To place the
part into normal power operation, write 0x004 to the AFE
OPRMODE register (Addr 0x00 in Bank 1).
6.
Write a 1 to the BANKSELECT register (Addr 0×7F)). This
will select Register Bank 2. Load Bank 2 registers with the
required VPAT group, vertical sequence, and field timing
information.
7.
Write a 0 to the BANKSELECT register to select Bank 1.
8.
By default, the internal timing core is held in a reset state
with TGCORE_RSTB register = 0. Write a 1 to the
TGCORE_RSTB register (Addr 0x15 in Bank 1) to start the
internal timing core operation. Note: If a 2x clock is used
for the CLI input, the CLIDIVIDE register (Addr 0x30)
should be set to 1 before resetting the timing core.
9.
Load the required registers to configure the high speed
timing, horizontal timing, and shutter timing information.
10. Configure the AD9925 for master mode timing by writing
a 1 to the MASTER register (Addr 0x20 in Bank 1).
11. Write a 1 to the OUT_CONTROL register (Addr 0x11 in
Bank 1).This will allow the outputs to become active after
the next SYNC rising edge.
12. Generate a SYNC event: If SYNC is high at power-up,
bring the SYNC input low for a minimum of 100 ns. Then
bring SYNC back to high. This will cause the internal
counters to reset and will start the VD/HD operation. The
first VD/HD edge allows most Bank 1 register updates to
occur, including OUT_CONTROL to enable all outputs.
Rev. A | Page 52 of 96
AD9925
Table 33. Power-Up Register Write Sequence
Address
0x10
0x0A to 0x0D
0x00
0x7F
0x00 to 0xFF
Data
0x01
TBD
0x04
0x01
TBD
0x7F
0x15
0x31 to 0x71
0x20
0x11
0x13
0x00
0x01
TBD
0x01
0x01
0x01
Description
Reset All Registers to Default Values
Standby V-Driver Input Signal Polarities
Power-Up the AFE and CLO Oscillator
Select Register Bank 2
VPAT, Vertical Sequence, and Field
Timing
Select Register Bank 1
Reset Internal Timing Core
Horizontal and Shutter Timing
Configure for Master Mode
Enable All Outputs after SYNC
SYNCPOL (for Software SYNC Only)
Generating Software SYNC without External SYNC Signal
If an external SYNC pulse is not available, it is possible to generate an internal SYNC in the AD9925 by writing to the SYNCPOL
register (Addr 0x13). If the software SYNC option is used, the
SYNC input (Pin J5) should be tied to ground (VSS).
After power-up, follow the same procedure as before, for Steps 1
through 11. Then, for Step 12, instead of using the external
SYNC pulse, write a 1 to the SYNCPOL register. This will generate the SYNC internally, and the timing operation will begin.
SYNC during Master Mode Operation
The SYNC input may be used any time during operation to
resync the AD9925 counters with external timing, as shown in
Figure 68. The operation of the digital outputs may be suspended
during the SYNC operation by setting the SYNCSUSPEND register (Addr 0x14) to a 1.
When the AD9925 is used in slave mode, the VD and HD inputs are used to synchronize the internal counters. Following a
falling edge of VD, there will be a latency of 23 master clock edges
(CLI) after the falling edge of HD until the internal H-Counter is
reset. The reset operation is shown in Figure 69.
Vertical Toggle Position Placement near Counter Reset
One additional consideration during the reset of the internal
counters is the vertical toggle position placement. Before the internal counters are reset, there is an area of 18 pixels where no
toggle positions should be programmed.
For master mode, the last 18 pixels before the HD falling edge
should not be used for toggle position placement of the XV, XSG,
SUBCK, HBLK, PBLK, or CLPOB pulses (see Figure 70).
Figure 71 shows the same example for slave mode. The same
restriction applies: the last 18 pixels before the counters are reset
and cannot be used. However, in slave mode, the counter reset is
delayed with respect to VD/HD placement; therefore, the inhibited area is different than it is in master mode.
Additional Considerations for Toggle Positions
In addition to avoiding toggle position placement near the counterreset location, there are a couple of other recommendations.
Pixel location 0 should not be used for any of the toggle positions
for the XSG and SUBCK pulses.
Also, the propagation delay of the V-driver circuit should be considered when programming the toggle positions for the XV, XSG,
and SUBCK pulses. The delay of the V-driver circuit is specified
in Table 3 and is a maximum of 200 ns.
Power-Up and Synchronization in Slave Mode
The power-up procedure for slave mode operation is the same
as the procedure described for master mode operation, with
two exceptions:
1.
Eliminate Step 10. Do not write the part into master mode.
2.
No SYNC pulse is required in slave mode. Substitute Step
12 with starting the external VD and HD signals. This will
synchronize the part, allow the Bank 1 register updates,
and start the timing operation.
Rev. A | Page 53 of 96
AD9925
SYNC
VD
SUSPEND
HD
NOTES
1. SYNC RISING EDGE RESETS VD/HD AND COUNTERS TO ZERO.
2. SYNC POLARITY IS PROGRAMMABLE USING SYNCPOL REGISTER (ADDR 0x13).
3. DURING SYNC LOW, ALL INTERNAL COUNTERS ARE RESET AND VD/HD CAN BE SUSPENDED USING THE SYNCSUSPEND REGISTER (ADDR 0x14).
4. IF SYNCSUSPEND = 1, VERTICAL CLOCKS, H1 TO H2, AND RG ARE HELD AT THEIR DEFAULT POLARITIES.
5. IF SYNCSUSPEND = 0, CLOCK OUTPUTS CONTINUE TO OPERATE NORMALLY UNTIL SYNC RESET EDGE.
04637-0-058
H124, RG, V1 TO 4,
VSG, SUBCK
Figure 68. SYNC Timing to Synchronize AD9925 with External Timing
VD
HD
H-COUNTER
RESET
3ns MIN
CLI
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
0
1
2
3
4
04637-0-076
H-COUNTER
(PIXEL COUNTER) X
NOTE
INTERNAL H-COUNTER IS RESET 23 CLOCK EDGES AFTER THE HD FALLING EDGE.
Figure 69. External VD/HD and Internal H-Counter Synchronization, Slave Mode
VD
H-COUNTER
RESET
HD
NO TOGGLE POSITIONS ALLOWED IN THIS AREA
N-22 N-21 N-20 N-19 N-18 N-17 N-16 N-15 N-14 N-13 N-12 N-11 N-10 N-9
N-8
N-7
N-6
N-5
N-4
N-3
N-2
N-1
N
0
1
2
3
4
1
2
3
4
04637-0-077
H-COUNTER
(PIXEL COUNTER)
NOTE
TOGGLE POSITIONS CANNOT BE PROGRAMMED WITHIN 18 PIXELS OF PIXEL 0 LOCATION.
Figure 70. Toggle Position Inhibit Area, Master Mode
VD
H-COUNTER
RESET
HD
N-22 N-21 N-20 N-19 N-18 N-17 N-16 N-15 N-14 N-13 N-12 N-11 N-10
N-9
N-8
N-7
N-6
N-5
NOTE
TOGGLE POSITIONS CANNOT BE PROGRAMMED WITHIN 18 PIXELS OF PIXEL 0 LOCATION.
Figure 71. Toggle Position Inhibit Area, Slave Mode
Rev. A | Page 54 of 96
N-4
N-3
N-2
N-1
N
0
04637-0-078
NO TOGGLE POSITIONS ALLOWED IN THIS AREA
H-COUNTER
(PIXEL COUNTER)
AD9925
OPRMODE[1:0] = 00 = Normal Operation (Full Power)
OPRMODE[1:0] = 01 = Standby 1 Mode
OPRMODE[1:0] = 10 = Standby 2 Mode
OPRMODE[1:0] = 11 = Standby 3 Mode (Lowest Overall Power)
the digital output states, but the standby 3 mode takes priority
over OUT_CONTROL. Standby 3 mode has the lowest power
consumption and even shuts down the crystal oscillator circuit
between CLI and CLO. Thus, if CLI and CLO are being used
with a crystal to generate the master clock, this circuit will be
powered down and there will be no clock signal. When returning from standby 3 mode to normal operation, the timing core
must be reset at least 500 µs after the OPRMODE register is
written to. This will allow sufficient time for the crystal circuit
to settle.
Table 34 and Table 35 summarize the operation of each powerdown mode. Note that the OUT_CONTROL register takes
priority over the standby 1 and standby 2 modes in determining
The XV and shutter outputs can also be programmed to hold a
specific value during any of the standby modes, as detailed in
Table 35.
STANDBY MODE OPERATION
The AD9925 contains three different standby modes to optimize
the overall power dissipation in a particular application. Bits [1:0]
of the OPRMODE register control the power-down state of the
device:
Table 34. Standby Mode Operation
I/O Block
AFE
Timing Core
CLO Oscillator
CLO
H1
H2
H3
H4
RG
VD
HD
DCLK
DOUT
Standby 3 (Default)1, 2
Off
Off
Off
High
Hi-Z
Hi-Z
Hi-Z
Hi-Z
Hi-Z
Low
Low
Low
Low
OUT_CONT= LO2
No Change
No Change
No Change
Running
Low
High
Low
High
Low
VDHDPOL Value
VDHDPOL Value
Low
Low
1
Standby 23, 4
Off
Off
On
Running
Low (4.3 mA)
High (4.3 mA)
Low (4.3 mA)
High (4.3 mA)
Low (4.3 mA)
VDHDPOL Value
VDHDPOL Value
Low
Low
Standby 13, 4
Off
Off
On
Running
Low (4.3 mA)
High (4.3 mA)
Low (4.3 mA)
High (4.3 mA)
Low (4.3 mA)
Undefined in Master Mode
Undefined in Master Mode
Running if DCLK MODE =1
Low
To exit standby 3 mode, first write a 00 to OPRMODE[1:0], then reset the timing core after ~500 µs to guarantee proper settling of the oscillator.
Standby 3 mode takes priority over OUT_CONTROL for determining the output polarities.
3
These polarities assume OUT_CONT = High., because OUT_CONTROL = Low takes priority over standby 1 and standby 2 modes.
4
Standby 1 and standby 2 modes will set H and RG drive strength to minimum value (4.3 mA).
2
Rev. A | Page 55 of 96
AD9925
Table 35. Standby Mode Operation—Vertical and Shutter Outputs (Programmable Polarities Available)
I/O Block
XV1
XV8
XV3
XV7
XV6
XSG6
XV5
XV4
XSG5
XSG4
XV2
XSG3
XSG1
XSG2
SUBCK
VSUB
MSHUT
STROBE
Standby 3 (Default)1, 2
Low
Low
Low
Low
Low
Low
Low
Low
Low
Low
Low
Low
Low
Low
Low
Low
Low
Low
OUT_CONT = Low2, 3
Low
Low
Low
Low
High
High
High
High
High
High
High
High
High
High
High
Low
Low
Low
1
Standby 23
Low
Low
Low
Low
High
High
High
High
High
High
High
High
High
High
High
Low
Low
Low
Standby 13
Low
Low
Low
Low
High
High
High
High
High
High
High
High
High
High
High
Low
Low
Low
Polarities for vertical and shutter outputs are programmable for each standby mode, using the STBYPOL registers.
Default register values are:
STBY3POL = Bin 00000000000000000 = 0x00
OCONTPOL = STBY2POL = STBY1POL = Bin 000011111111111000 = 0x3FF8
3
Bit assignments for programming polarity registers: (MSB) XV1, XV8, XV3, XV7, XV6, XSG6, XV5, XV4, XSG5, XSG4, XV2, XSG3, XSG1, XSG2, SUBCK, VSUB, MSHUT, and
STROBE (LSB).
2
Rev. A | Page 56 of 96
AD9925
The AD9925 typical circuit connections are shown in Figure 73.
The PCB layout is critical in achieving good image quality from
the AD9925. All of the supply pins, particularly the AVDD,
TCVDD, RGVDD, and HVDD supplies, must be decoupled to
ground with good quality, high frequency chip capacitors. The
decoupling capacitors should be located as close as possible to
the supply pins and should have a very low impedance path to a
continuous ground plane. There should also be a 4.7 µF or larger
value bypass capacitor near each main supply—AVDD, HVDD,
DRVDD, VL, and VH—although this is not necessary for each
individual pin. In most applications, it is easier to share the
supply for RGVDD and HVDD, which may be done as long as
the individual supply pins are separately bypassed. A separate
3 V supply may also be used for DRVDD, but this supply pin
should still be decoupled to the same ground plane as the rest of
the chip. A separate ground for DRVSS is not recommended.
The H1 to H4 and RG traces should be designed to have low
inductance to avoid excessive distortion of the signals. Heavier
traces are recommended because of the large transient current
demand on H1 to H4 by the CCD. If possible, physically locating the AD9925 closer to the CCD will reduce the inductance
on these lines. As always, the routing path should be as direct as
possible from the AD9925 to the CCD.
The AD9925 also contains an on-chip oscillator for driving an
external crystal. Figure 72 shows an example of an application
using a typical 24 MHz crystal. For the exact values of the external resistors and capacitors, it is best to consult with the crystal
manufacturer’s data sheet.
The analog bypass pins (REFT and REFB) should also be carefully decoupled to ground as close as possible to their respective
pins. The analog input (CCDIN) capacitor should also be located
close to the pin.
AD9925
J6
J4
CLI
CLO
1MΩ
20pF
24MHz
XTAL
500Ω
20pF
Figure 72. Crystal Driver Application
Rev. A | Page 57 of 96
04637-0-060
CIRCUIT LAYOUT INFORMATION
AD9925
HORIZONTAL SYNC TO/FROM ASIC/DSP
VERTICAL SYNC TO/FROM ASIC/DSP
+3V ANALOG SUPPLY
10
0.1µF
TO STROBE CIRCUIT
–7.5V SUPPLY
3
+15V SUPPLY
SDI
SCK
J11
J10
VM2
STROBE
H9
V7
V8
J9
H11
K10
V4
V6
H10
G10
VD
V2
G9
G11
DVSS
HD
F9
DVDD
V5B
E9
F11
F10
V3A
V3B
V5A
D9
C9
B9
VM1
V1
B8
C8
C7
NC
NC
VL
VH1
E11
C6
L10
RSTB
D2
C11
K9
VH2
D3
D4
B10
K8
VL
B11
J8
SUBCK
D5
D6
A10
J7
A9
L9
MSHUT
REFB
D7
D8
A8
L8
B7
D9
A7
D10
B6
D11 (MSB)
DRVDD
DRVSS
A6
C5
AD9925
NOT DRAWN TO SCALE
EXTERNAL RESET INPUT
(NORMALLY HIGH,
PULSE LOW TO RESET)
+15V SUPPLY
–7.5V SUPPLY
0.1µF 0.1µF
SUBCK OUTPUT TO CCD
TO SHUTTER CIRCUIT
+3V ANALOG
1µF
SUPPLY
+
4.7µF
1µF
K7
REFT
AVDD
L6
CCDIN
0.1µF
L7
AVSS
K6
AVSS
J6
CLI
B5
L5
TCVSS
ANALOG OUTPUT
FROM CCD
0.1µF
VSUB
A5
K5
TCVSS
MASTER CLOCK INPUT
VDVDD
A4
J5
SYNC
EXTERNAL SYNC INPUT
VDVSS
NC
B4
C4
J4
K4
CLO
NC
NC
NC
B3
A3
K3
B2
L3
TCVDD
RGVDD
RG
L2
A2
A1
+3V ANALOG SUPPLY
+3V H, RG SUPPLY
0.1µF
RGVSS
RGVSS
L1
K1
0.1µF
TCVDD
NC
3
0.1µF
+
Figure 73. AD9925 Typical Circuit Configuration
Rev. A | Page 58 of 96
+3V H, RG SUPPLY
4.7µF
H1 TO H4, RG OUTPUTS
(TO CCD)
04637-0-061
J1
H3
H4
J3
H3
J2
HVDD
HVDD
HVDD
H1
H2
HVDD
G1
F1
H1
H2
HVDD
G3
HVSS
G2
F2
F3
HVSS
HVSS
HVSS
HVSS
E3
E1
NC
E2
NC
D3
D2
D1
K2
NC
NC
NC
NC
NC
L4
C3
VSUB TO CCD
NC
C10
C2
0.1µF
SL
L11
NC
NC
0.1µF
A11
NC
+
4.7µF
K11
D11
C1
+3V DRIVER
E10
B1
12
DCLK
D0 (LSB)
D1
NC
NC
DATA
OUTPUTS
SERIAL INTERFACE
(FROM ASIC/DSP)
0.1µF
D10
0.1µF
DCLK TO ASIC/DSP
VERTICAL CLOCK OUTPUTS
(TO CCD)
AD9925
Figure 75 shows a more efficient way to write to the registers,
using the AD9925’s address automatic increment capability.
Using this method, the lowest desired address is written first,
followed by multiple 24-bit data-words. Each new 24-bit dataword will automatically be written to the next highest register
address. By eliminating the need to write each 8-bit address,
faster register loading is achieved. Continuous write operations
may be used starting with any register location and may be used
to write to as few as two registers or to as many as the entire
register space.
SERIAL INTERFACE TIMING
All of the internal registers of the AD9925 are accessed through
a 3-wire serial interface. Each register consists of an 8-bit address
and a 24-bit data-word. Both the 8-bit address and 24-bit dataword are written starting with the LSB. To write to each register,
a 32-bit operation is required, as shown in Figure 74. Although
many registers are fewer than 24 bits wide, all 24 bits must be
written for each register. For example, if the register is only 10
bits wide, then the upper 14 bits are Don’t Cares and may be
filled with 0s during the serial write operation. If fewer than 24
bits are written, the register will not be updated with new data.
8-BIT ADDRESS
SDATA
A0
A1
A2
A3
tDS
SCK
1
A4
24-BIT DATA
A5
A6
A7
D0
D1
D2
D3
D21
D22
D23
tDH
2
3
4
5
6
7
8
9
10
11
12
30
tLS
31
32
tLH
NOTES
1. SDATA BITS ARE LATCHED ON SCK RISING EDGES. SCK MAY IDLE HIGH OR LOW IN BETWEEN WRITE OPERATIONS.
2. ALL 32 BITS MUST BE WRITTEN: 8 BITS FOR ADDRESS AND 24 BITS FOR DATA.
3. IF THE REGISTER LENGTH IS < 24 BITS, THEN DON’T CARE BITS MUST BE USED TO COMPLETE THE 24-BIT DATA LENGTH.
4. NEW DATA VALUES ARE UPDATED IN THE SPECIFIED REGISTER LOCATION AT DIFFERENT TIMES, DEPENDING ON THE
PARTICULAR REGISTER WRITTEN TO. SEE THE REGISTER UPDATES SECTION FOR MORE INFORMATION.
04637-0-062
SL
Figure 74. Serial Write Operation
DATA FOR STARTING
REGISTER ADDRESS
SDATA
SCK
A0
1
A1
2
A2
3
A3
4
A4
5
A5
6
A6
7
A7
8
D0
9
D1
10
D22
31
DATA FOR NEXT
REGISTER ADDRESS
D23
32
D0
33
D1
34
D22
55
D23
56
D0
57
D1
58
D2
59
NOTES
1. MULTIPLE SEQUENTIAL REGISTERS MAY BE LOADED CONTINUOUSLY.
2. THE FIRST (LOWEST ADDRESS) REGISTER ADDRESS IS WRITTEN, FOLLOWED BY MULTIPLE 24-BIT DATA-WORDS.
3. THE ADDRESS WILL AUTOMATICALLY INCREMENT WITH EACH 24-BIT DATA-WORD (ALL 24 BITS MUST BE WRITTEN).
4. SL IS HELD LOW UNTIL THE LAST DESIRED REGISTER HAS BEEN LOADED.
Figure 75. Continuous Serial Write Operation
Rev. A | Page 59 of 96
04637-0-063
SL
AD9925
Register Address BANK 1, BANK 2, and BANK 3
The AD9925 address space is divided into three different register banks, referred to as Register Bank 1, Register Bank 2, and
Register Bank 3. Figure 76 illustrates how the three banks are
divided. Register Bank 1 and Bank 2 are backward compatible
with the AD9995 registers. Register Bank 1 contains the registers for the AFE, miscellaneous functions, VD/HD parameters,
timing core, CLPOB masking, VSG patterns, and shutter functions. Register Bank 2 contains all of the information for the
vertical pattern groups, vertical sequences, and field information.
Register Bank 3 contains new registers for accessing the XV7 and
XV8 functionality. These additional outputs allow the AD9925 to
support newer CCDs that require 8-phases of vertical clocking.
Note that Register Bank 1 contains many unused addresses.
Undefined addresses between Addr 0x00 and Addr 0x7F are
considered Don’t Cares, and it is acceptable if these addresses
are filled in with all 0s during a continuous register write operation. However, the undefined addresses above 0x7F must not be
written to, or the AD9925 may not operate properly. The exceptions are the FG_TRIG registers 0xE7, 0xEB, and 0xF2 through
0xF6, which may be written as specified on Page 43.
Default values for Register Bank 2 and Bank 3 are undefined after
power-up. Appropriate values should be written into these register banks to ensure proper operation. In applications where the
XV7 and XV8 signals are not used, the Bank 3 registers should
still be programmed with known values to prevent unpredictable behavior in the V-driver circuit.
When writing to the AD9925, Addr 0x7F is used to specify
which address bank is being written to. To write to Bank 1, a
data value of 0 is written. To write to Bank 2, a data value of 1 is
written. To write to Bank 3, a data value of 2 is written.
REGISTER BANK 3
REGISTER BANK 2
REGISTER BANK 1
ADDR 0x00
ADDR 0x00
ADDR 0x00
AFE REGISTERS
VPAT0 TO VPAT9 REGISTERS
FOR
XV7, XV8 SIGNALS
ADDR 0x10
MISCELLANEOUS REGISTERS
ADDR 0x40
VPAT0 TO VPAT9 REGISTERS
FOR
XV1 TO XV6 SIGNALS
VD/HD REGISTERS
TIMING CORE REGISTERS
CLPOB MASK REGISTERS
ADDR 0x50
VSG PATTERN REGISTERS
ADDR 0x7E
ADDR 0x7F
ADDR 0x4F
ADDR 0x50
ADDR 0x77
SWITCH TO
REGISTER BANK 1, BANK 3
ADDR 0x7F
VSEQ0 TO VSEQ9 REGISTERS
FOR
XV1 TO XV6 SIGNALS
INVALID, DO NOT ACCESS
SHUTTER REGISTERS
SWITCH TO
REGISTER BANK 2, BANK 3
ADDR 0xCF
ADDR 0xD0
ADDR 0x8F
FIELD 0 TO FIELD 5 REGISTERS
INVALID, DO NOT ACCESS
ADDR 0xFF
SWITCH TO
REGISTER BANK 2, BANK 3
ADDR 0x80
ADDR 0x60
ADDR 0x7F
VSEQ0 TO VSEQ9 REGISTERS
FOR
XV7, XV8 SIGNALS
ADDR 0xFF
ADDR 0xFF
WRITE TO ADDRESS 0x7F TO SWITCH REGISTER BANKS
Figure 76. Layout of Internal Register Bank 1, Bank 2, and Bank 3
Rev. A | Page 60 of 96
04637-0-064
ADDR 0x20
ADDR 0x30
AD9925
Updating New Register Values
3.
SG Line Updated: A few of the registers in Bank 1 are updated at the end of the SG active line, at the HD falling
edge. These registers control the SUBCK signal, so that the
SUBCK output will not update until after the SG line has
been completed. These registers are crosshatched in the
Bank 1 register list.
4.
SCP Updated: In Bank 2 and Bank 3, all of the vertical
pattern group and vertical sequence registers (Addr 0x00
through Addr 0xCF, excluding Addr 0×7F) are updated at
the next SCP, where they will be used. For example, in
Figure 77, this field has selected Region 1 to use Vertical
Sequence 3 for the vertical outputs. This means that a write
to any of the Vertical Sequence 3 registers, or any of the vertical pattern group registers that are referenced by Vertical
Sequence 3, will be updated at SCP1. If multiple writes are
done to the same register, the last one done before SCP1
will be the one that is updated. Likewise, register writes to
any Vertical Sequence 5 registers will be updated at SCP2,
and register writes to any Vertical Sequence 8 registers will
be updated at SCP3.
The AD9925’s internal registers are updated at different times,
depending on the particular register. Table 36 summarizes the
four different types of register updates:
1.
2.
SCK Updated: Some of the registers in Bank 1 are updated
as soon as the 24th data bit (D23) is written. These registers, shaded in gray in the Bank 1 register list, are used for
functions that do not require gating with the next VD
boundary, such as power-up and reset functions. The bank
select register (Addr 0x7F in Bank 1 and Bank 2) is also
SCK updated.
VD Updated: Most of the registers in Bank 1, as well as the
field registers in Bank 2, are updated at the next VD falling
edge. By updating these values at the next VD edge, the
current field will not be corrupted, and the new register
values will be applied to the next field. Bank 1 register updates may be further delayed past the VD falling edge by
using the UPDATE register (Addr 0x19). This will delay
VD updates to any HD line in the field. Note that the Bank 2
field registers are not affected by the UPDATE register.
Table 36. Register Update Locations
Update Type
SCK Updated
VD Updated
Register Bank
Bank 1 Only
Bank 1, Bank 2
SG Line Updated
SCP Updated
Bank 1 Only
Bank 2, Bank 3
Description
Register is immediately updated when the 24th data bit (D23) is clocked in.
Register is updated at the VD falling edge. VD updated registers in Bank 1 may be delayed further
by using the UPDATE register at Addr 0x19 in Bank 1. Bank 2 updates will not be affected by the
UPDATE register.
Register is updated at the HD falling edge at the end of the SG active line.
Register is updated at the next SCP when the register will be used.
SCK
UPDATED
VD
UPDATED
SG
UPDATED
SCP
UPDATED
SERIAL
WRITE
VD
HD
SGLINE
XSG
USE VSEQ2
USE VSEQ3
USE VSEQ5
REGION 0
REGION 1
REGION 2
SCP 0
SCP 1
SCP 2
USE VSEQ8
REGION 3
SCP 3
Figure 77. Register Update Locations (See Table 40 for Definitions)
Rev. A | Page 61 of 96
SCP 0
04637-0-065
XV1 TO XV6
AD9925
COMPLETE LISTING FOR REGISTER BANK 1
All registers are VD updated, except where noted. Light gray cells = SCK updated, and dark gray cells = SG line updated.
Table 37. AFE Register Map
Address
00
01
02
03
Data Bit Content
[11:0]
[9:0]
[7:0]
[11:0]
Default Value
7
0
80
4
Register Name
OPRMODE
VGAGAIN
CLAMPLEVEL
CTLMODE
Register Description
AFE Operation Modes (See Table 45 for detail)
VGA Gain
Optical Black Clamp Leve
AFE Control Modes (See Table 46 for detail)
Register Description
Polarities for Output Signals during Standby 1 Mode.
Polarities for Output Signals during Standby 2 Mode.
Polarities for Output Signals during Standby 3 Mode.
Polarities for Output Signals When OUTCONTROL = 0.
Software Reset. 1: Reset all registers to default, then self clear back
to 0.
Output Control. 0: Make all outputs dc inactive.
Configures Pin 52 as a SYNC Input (= 1) or CLPOB/PBLK Output (= 0).
SYNC Active Polarity (0: Active Low).
Suspend Clocks during SYNC Active (1: Suspend).
Timing Core Reset Bar. 0: Reset TG Core, 1: Resume Operation.
CLO Oscillator Power-Down (0: Oscillator Is Powered Down).
Table 38. Miscellaneous Register Map
Address
0A
0B
0C
0D
10
Data Bit Content
[17:0]
[17:0]
[17:0]
[17:0]
[0]
Default Value
3FF8
3FF8
0
3FF8
0
Register Name
STBY1POL
STBY2POL
STBY3POL
OCONTPOL
SW_RST
11
12
13
14
15
16
[0]
[0]
[0]
[0]
[0]
[0]
0
1
0
0
0
1
17
18
19
1A
[0]
[11:0]
[0]
0
0
0
1B
1C
1D
[23:0]
0
[0]
0
OUTCONTROL
SYNCENABLE
SYNCPOL
SYNCSUSPEND
TGCORE_RSTB
OSC_PWRDOW
N
UNUSED
TEST
UPDATE
PREVENTUPDATE
MODE
UNUSED
OUTPUTPBLK
1E
[0]
0
DVCMODE
1F
E7
[0]
[2:0]
[3]
[5:4]
[6]
0
0
INVERT_DCLK
SHUT_EXTRA
0
0
0
0
0
0
FG_TRIGEN
FG_TRIGPOL
FG_TRIGLIN1
FG_TRIGPIX1
FG_TRIGLIN2
FG_TRIGPIX2
EB
F2
F3
F4
F5
F6
[7]
[8]
[3:0]
[0]
[11:0]
[12:0]
[11:0]
[12:0]
Set to 0.
Internal Use Only. Must be set to 0.
Serial Update. Line (HD) in the field to update VD updated registers.
Prevents the update of the VD updated registers. 1: Prevent Update.
MODE Register.
Set to 0.
Assigns Output for Pin 52 When Configured as Output.
0: CLPOB, 1: PBLK.
1: Enable DVC Mode. VD counter will reset every 2 fields, instead of
every field. VDLEN register should be programmed to the total number of lines contained in 2 fields, e.g., VDLEN = 525 lines will results
in 262.5 lines in each field.
1: Invert the DCLK Output.
Set to 0.
Selects FG_TRIG Signal to VSUB Pin (See Page 43).
Set to 0.
H3HBLKOFF, Set to 1 to Enable H3/H4 Outputs during HBLK (See
Page 19).
Set to 0.
Combines FG_TRIG and VSUB Signals (See Page 43).
FG_TRIG Signal Enable (See Page 43).
FG_TRIG Start Polarity.
FG_TRIG First Toggle Position, Line Location.
FG_TRIG First Toggle Position, Pixel Location.
FG_TRIG Second Toggle Position, Line Location.
FG_TRIG Second Toggle Position, Pixel Location.
Rev. A | Page 62 of 96
AD9925
Table 39. VD/HD Register Map
Address
20
21
22
23
Data Bit Content
[0]
[0]
[11:0]
[17:12]
[11:0]
Default Value
0
0
0
0
0
Register Name
MASTER
VDHDPOL
HDRISE
VDRISE
SCP0
Register Description
VD/HD Master or Slave Timing (0 = Slave Mode).
VD/HD Active Polarity. 0 = Low and 1 = High.
Rising Edge Location for HD.
Rising Edge Location for VD.
SCP0. Used for All Fields.
Register Description
Divide CLI Input Clock by 2. 1 = Divide by 2.
H1 Polarity. 0: Inversion, 1: No Inversion.
H1 Positive Edge Location.
H1 Negative Edge Location.
H3 Polarity. 0: Inversion, 1: No Inversion.
H3 Positive Edge Location.
H3 Negative Edge Location.
RG Polarity. 0: Inversion, 1: No Inversion.
RG Positive Edge Location.
RG Negative Edge Location.
Retime H1/H3 HBLK to Internal H1/H3 Clocks. Preferred setting is 1
for each bit, which adds one cycle of delay to the programmed HBLK
toggle positions.
Drive Strength Control for H1.
0: Off.
1: 4.3 mA.
2: 8.6 mA.
3: 12.9 mA.
4: 17.2 mA.
5: 21.5 mA.
6: 25.8 mA.
7: 30.1 mA.
Drive Strength Control for H2 (Same Values as H1DRV).
Drive Strength Control for H3 (Same Values as H1DRV).
Drive Strength Control for H4 (Same Values as H1DRV).
Drive Strength Control for RG (Same Values as H1DRV).
SHP Sampling Location.
SHD Sampling Location.
DOUT Phase Control.
0: DCLK Tracks DOUTPHASE.
1: DCLK Does Not Track DOUTPHASE, Remains Fixed with Regards to
CLI
Data Output Delay (tOD) with Respect to DCLK.
0: No Delay, 1: ~4 ns, 2: ~8 ns, and 3: ~12 ns.
Controls HBLK Width as a Fraction of H1 to H4 Frequency.
0: same, 1: 1/2, 2: 1/4, 3: 1/6, 4: 1/8, 5: 1/10, 6: 1/12, and 7: 1/14.
Table 40. Timing Core Register Map
Address
30
31
32
33
34
35
36
37
38
Data Bit Content
[0]
[0]
[6:1]
[12:7]
[0]
[6:1]
[12:7]
[0]
[6:1]
[12:7]
[0]
[1]
Default Value
0
1
0
20
1
0
20
1
0
20
0
0
Register Name
CLIDIVIDE
H1POL
H1POSLOC
H1NEGLOC
H3POL
H3POSLOC
H3NEGLOC
RGPOL
RGPOSLOC
RGNEGLOC
H1RETIME
H3RETIME
[2:0]
1
H1DRV
[5:3]
[8:6]
[11:9]
[14:12]
[5:0]
[11:6]
[5:0]
[6]
1
1
1
1
24
0
0
0
H2DRV
H3DRV
H4DRV
RGDRV
SHPLOC
SHDLOC
DOUTPHASE
DCLKMODE
[8:7]
2
DOUTDLY
[2:0]
0
HBLKWIDTH
Table 41. CLPOB Masking Register Map
Address
40
41
42
43
Data Bit Content
[11:0]
[23:12]
[11:0]
[23:12]
[11:0]
[11:0]
[12]
Default Value
FFF
FFF
FFF
FFF
FFF
FFF
0
Register Name
CLPMASK0
CLPMASK1
CLPMASK2
CLPMASK3
CLPMASK4
CLPMASK5
CLPMASKTYPE
Register Description
CLPOB Line Masking Line No. 0, or Mask0 Range, Start Line
CLPOB Line Masking Line No. 1, or Mask0 Range, End Line
CLPOB Line Masking Line No. 2, or Mask1 Range, Start Line
CLPOB Line Masking Line No. 3, or Mask1 Range, End Line
CLPOB Line Masking Line No. 4, or Mask2 Range, Start Line
CLPOB Line Masking Line No. 5, or Mask2 Range, End Line
0: CLPOB Line Masking, 1: Enable CLPOB Range Masking
Rev. A | Page 63 of 96
AD9925
Table 42. SG Pattern Register Map
Address
50
51
52
53
54
55
Data Bit Content
[0]
[1]
[2]
[3]
[11:0]
[23:12]
[11:0]
[23:12]
[11:0]
[23:12]
[11:0]
[23:12]
[5:0]
Default Value
1
1
1
1
FFF
FFF
FFF
FFF
FFF
FFF
FFF
FFF
0
Register Name
SGPOL_0
SGPOL_1
SGPOL_2
SGPOL_3
SGTOG1_0
SGTOG2_0
SGTOG1_1
SGTOG2_1
SGTOG1_2
SGTOG2_2
SGTOG1_3
SGTOG2_3
SGMASK_OVR
[6]
0
SGMASKOVR_EN
Register Description
Start Polarity for SG Pattern No. 0.
Start Polarity for SG Pattern No. 1.
Start Polarity for SG Pattern No. 2.
Start Polarity for SG Pattern No. 3.
Pattern No. 0 Toggle Position 1.
Pattern No. 0 Toggle Position 2.
Pattern No. 1 Toggle Position 1.
Pattern No. 1 Toggle Position 2.
Pattern No. 2 Toggle Position 1.
Pattern No. 2 Toggle Position 2.
Pattern No. 3 Toggle Position 1.
Pattern No. 3 Toggle Position 2.
SGMASK Override. These values will immediately override the SG
masking values located in the field registers.
0: Use SG Masking in Field Registers, 1: Enable SGMASK Override.
Table 43. Shutter Control Register Map
Address
60
Data Bit Content
[4:0]
Default Value
0
Register Name
TRIGGER
61
[2:0]
2
READOUT
62
[11:0]
[12]
0
0
EXPOSURE
VDHDOFF
63
[11:0]
[23:12]
[0]
[11:0]
[23:12]
[11:0]
[23:12]
[0]
[1]
[11:0]
[12]
[0]
[1]
[11:0]
[23:12]
[11:0]
[11:0]
[23:12]
[0]
[11:0]
[11:0]
[23:12]
[11:0]
[11:0]
[23:12]
[3:0]
0
0
1
FFF
FFF
FFF
FFF
0
0
0
1
1
0
0
0
0
0
0
1
0
0
0
0
0
0
0
SUBCKSUPPRESS
SUBCKNUM
SUBCKPOL
SUBCK1TOG1
SUBCK1TOG2
SUBCK2TOG1
SUBCK2TOG2
VSUBMODE
VSUBKEEPON
VSUBON
VSUBPOL
MSHUTPOL
MSHUTON
MSHUTON_LN
MSHUTON_PX
MSHUTOFF_FD
MSHUTOFF_LN
MSHUTOFF_PX
STROBPOL
STROBON_FD
STROBON_LN
STROBON_PX
STROBOFF_FD
STROBOFF_LN
STROBOFF_PX
SUBCKTOG13
64
65
66
67
68
69
6A
6B
6C
6D
6E
6F
70
71
72
Register Description
Trigger for VSUB [0], MSHUT [1], STROBE [2], Exposure [3], and
Readout [4]. Note that to trigger the readout to automatically
occur after the exposure period, both exposure and readout
should be triggered together.
Number of Fields to Suppress the SUBCK Pulses after the VSG
Line.
Number of Fields to Suppress the SUBCK and VSG Pulses.
Set = 1 to disable the VD/HD outputs during exposure (when >1
field).
Number of SUBCK Pulses to Suppress after VSG Line.
Number of SUBCK Pulses per Field.
SUBCK Pulse Start Polarity.
First SUBCK Pulse. Toggle Position 1.
First SUBCK Pulse. Toggle Position 2.
Second SUBCK Pulse. Toggle Position 1.
Second SUBCK Pulse. Toggle Position 2.
VSUB Readout Mode. 0: Mode 0, 1: Mode 1.
0: Turn Off VSUB after Readout, 1: Keep VSUB On after Readout.
VSUB Online Position.
VSUB Active Polarity.
MSHUT Active Polarity.
MSHUT Manual Enable (Opens Shutter at Next VD Edge).
MSHUT On Position—Line.
MSHUT On Position—Pixel.
MSHUT Off Position—Field.
MSHUT Off Position—Line.
MSHUT Off Position—Pixel.
STROBE Active Polarity.
STROBE On Position—Field.
STROBE On Position—Line.
STROBE On Position—Pixel.
STROBE Off Position—Field.
STROBE Off Position—Line.
STROBE Off Position—Pixel.
13th Bit for SUBCK Toggle Position Placement.
Rev. A | Page 64 of 96
AD9925
Table 44. Register Map Selection
Address
7F
Data Bit Content
[1:0]
Default Value
0
Register Name
BANKSELECT
Register Description
Register Bank Access for Bank 1, Bank 2, and Bank 3.
0: Bank 1, 1: Bank 2, 2: Bank 3, and 3: Bank 1.
Description
0: Normal Operation, 1: Standby 1, 2: Standby 2, 3: Standby 3.
0: Disable OB Clamp, 1: Enable OB Clamp.
0: Select Normal OB Clamp Settling, 1: Select Fast OB Clamp
Settling.
1: Select Temporary Fast Clamping When VGA Gain Is Updated.
DOUT Value during PBLK: 0: Blank to 0, 1: Blank to Clamp
Level.
Test Operation Only. Set to 0.
0: Enable DC Restore Circuit, 1: Bypass DC Restore Circuit during PBLK.
Test Use Only. Set to 0.
0: 0 dB, 1: 2 dB, 2: 4 dB, and 3: 0 dB.
Table 45. AFE Operation Register Detail
Address
00
Data Bit Content
[1:0]
[2]
[3]
Default Value
3
1
0
Name
PWRDOWN
CLPENABLE
CLPSPEED
[4]
0
FASTUPDATE
[5]
0
PBLK_LVL
[7:6]
[8]
0
0
TEST
DCBYP
[9]
[11:10]
0
0
TEST
CDSGAIN
Table 46. AFE Control Register Detail
Address
03
Data Bit Content
[1:0]
[2]
[3]
Default Value
0
1
0
Name
TEST
TEST
DOUTDISABLE
[4]
0
DOUTLATCH
[5]
0
GRAYENCODE
Description
Test Use Only. Set to 0.
Test Use Only. Recommended setting is 0.
0 = Data Outputs Are Driven,
1 = Data Outputs Are Three-Stated.
0 = Latch Data Outputs with DOUT Phase,
1 = Output Latch Transparent.
0 = Binary Encode Data Outputs,
1 = Gray Encode Data Outputs.
Rev. A | Page 65 of 96
AD9925
COMPLETE LISTING FOR REGISTER BANK 2
All vertical pattern group and vertical sequence registers are SCP updated, and all field registers are VD updated. Default register values
are undefined.
Table 47. Vertical Pattern Group 0 (VPAT0) Register Map
Address
00
Data Bit Content
[5:0]
[11:6]
[23:12]
Default Value
X
X
X
Register Name
VPOL_0
UNUSED
VPATLEN_0
01
[11:0]
[23:12]
[11:0]
[23:12]
[11:0]
[23:12]
[11:0]
[23:12]
[11:0]
[23:12]
[11:0]
[23:12]
[11:0]
[23:12]
[11:0]
[23:12]
[11:0]
[23:12]
[11:0]
[23:12]
[11:0]
[23:12]
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
XV1TOG1_0
XV1TOG2_0
XV1TOG3_0
XV2TOG1_0
XV2TOG2_0
XV2TOG3_0
XV3TOG1_0
XV3TOG2_0
XV3TOG3_0
XV4TOG1_0
XV4TOG2_0
XV4TOG3_0
XV5TOG1_0
XV5TOG2_0
XV5TOG3_0
XV6TOG1_0
XV6TOG2_0
XV6TOG3_0
FREEZE1_0
RESUME1_0
FREEZE2_0
RESUME2_0
02
03
04
05
06
07
08
09
0A
0B
Register Description
VPAT0 Start Polarity. XV1[0], XV2[1], XV3[2], XV4[3], XV5[4], XV6[5].
Unused.
Total Length of VPAT0. Note: If using VPAT0 as a second vertical
sequence in the VSG active line, this value is the start position for
the second vertical sequence.
XV1 Toggle Position 1.
XV1 Toggle Position 2.
XV1 Toggle Position 3.
XV2 Toggle Position 1.
XV2 Toggle Position 2.
XV2 Toggle Position 3.
XV3 Toggle Position 1.
XV3 Toggle Position 2.
XV3 Toggle Position 3.
XV4 Toggle Position 1.
XV4 Toggle Position 2.
XV4 Toggle Position 3.
XV5 Toggle Position 1.
XV5 Toggle Position 2.
XV5 Toggle Position 3.
XV6 Toggle Position 1.
XV6 Toggle Position 2.
XV6 Toggle Position 3.
XV1 to XV6 Freeze Position 1.
XV1 to XV6 Resume Position 1.
XV1 to XV6 Freeze Position 2.
XV1 to XV6 Resume Position 2.
Rev. A | Page 66 of 96
AD9925
Table 48. Vertical Pattern Group 1 (VPAT1) Register Map
Address
0C
Data Bit Content
[5:0]
[11:6]
[23:12]
Default Value
X
X
X
Register Name
VPOL_1
UNUSED
VPATLEN_1
0D
[11:0]
[23:12]
[11:0]
[23:12]
[11:0]
[23:12]
[11:0]
[23:12]
[11:0]
[23:12]
[11:0]
[23:12]
[11:0]
[23:12]
[11:0]
[23:12]
[11:0]
[23:12]
[11:0]
[23:12]
[11:0]
[23:12]
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
XV1TOG1_1
XV1TOG2_1
XV1TOG3_1
XV2TOG1_1
XV2TOG2_1
XV2TOG3_1
XV3TOG1_1
XV3TOG2_1
XV3TOG3_1
XV4TOG1_1
XV4TOG2_1
XV4TOG3_1
XV5TOG1_1
XV5TOG2_1
XV5TOG3_1
XV6TOG1_1
XV6TOG2_1
XV6TOG3_1
FREEZE1_1
RESUME1_1
FREEZE2_1
RESUME2_1
0E
0F
10
11
12
13
14
15
16
17
Register Description
VPAT1 Start Polarity. XV1[0], XV2[1], XV3[2], XV4[3], XV5[4], XV6[5].
Unused.
Total Length of VPAT1. Note: If using VPAT1 as a second vertical
sequence in the VSG active line, this value is the start position for
the second vertical sequence.
XV1 Toggle Position 1.
XV1 Toggle Position 2.
XV1 Toggle Position 3.
XV2 Toggle Position 1.
XV2 Toggle Position 2.
XV2 Toggle Position 3.
XV3 Toggle Position 1.
XV3 Toggle Position 2.
XV3 Toggle Position 3.
XV4 Toggle Position 1.
XV4 Toggle Position 2.
XV4 Toggle Position 3.
XV5 Toggle Position 1.
XV5 Toggle Position 2.
XV5 Toggle Position 3.
XV6 Toggle Position 1.
XV6 Toggle Position 2.
XV6 Toggle Position 3.
XV1 to XV6 Freeze Position 1.
XV1 to XV6 Resume Position 1.
XV1 to XV6 Freeze Position 2.
XV1 to XV6 Resume Position 2.
Rev. A | Page 67 of 96
AD9925
Table 49. Vertical Pattern Group 2 (VPAT2) Register Map
Address
18
Data Bit Content
[5:0]
[11:6]
[23:12]
Default Value
X
X
X
Register Name
VPOL_2
UNUSED
VPATLEN_2
19
[11:0]
[23:12]
[11:0]
[23:12]
[11:0]
[23:12]
[11:0]
[23:12]
[11:0]
[23:12]
[11:0]
[23:12]
[11:0]
[23:12]
[11:0]
[23:12]
[11:0]
[23:12]
[11:0]
[23:12]
[11:0]
[23:12]
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
XV1TOG1_2
XV1TOG2_2
XV1TOG3_2
XV2TOG1_2
XV2TOG2_2
XV2TOG3_2
XV3TOG1_2
XV3TOG2_2
XV3TOG3_2
XV4TOG1_2
XV4TOG2_2
XV4TOG3_2
XV5TOG1_2
XV5TOG2_2
XV5TOG3_2
XV6TOG1_2
XV6TOG2_2
XV6TOG3_2
FREEZE1_2
RESUME1_2
FREEZE2_2
RESUME2_2
1A
1B
1C
1D
1E
1F
20
21
22
23
Register Description
VPAT2 Start Polarity. XV1[0], XV2[1], XV3[2], XV4[3], XV5[4], XV6[5].
Unused.
Total Length of VPAT2. Note: If using VPAT2 as a second vertical
sequence in the VSG active line, this value is the start position for
second vertical sequence.
XV1 Toggle Position 1.
XV1 Toggle Position 2.
XV1 Toggle Position 3.
XV2 Toggle Position 1.
XV2 Toggle Position 2.
XV2 Toggle Position 3.
XV3 Toggle Position 1.
XV3 Toggle Position 2.
XV3 Toggle Position 3.
XV4 Toggle Position 1.
XV4 Toggle Position 2.
XV4 Toggle Position 3.
XV5 Toggle Position 1.
XV5 Toggle Position 2.
XV5 Toggle Position 3.
XV6 Toggle Position 1.
XV6 Toggle Position 2.
XV6 Toggle Position 3.
XV1 to XV6 Freeze Position 1.
XV1 to XV6 Resume Position 1.
XV1 to XV6 Freeze Position 2.
XV1 to XV6 Resume Position 2.
Rev. A | Page 68 of 96
AD9925
Table 50. Vertical Pattern Group 3 (VPAT3) Register Map
Address
24
Data Bit Content
[5:0]
[11:6]
[23:12]
Default Value
X
X
X
Register Name
VPOL_3
UNUSED
VPATLEN_3
25
[11:0]
[23:12]
[11:0]
[23:12]
[11:0]
[23:12]
[11:0]
[23:12]
[11:0]
[23:12]
[11:0]
[23:12]
[11:0]
[23:12]
[11:0]
[23:12]
[11:0]
[23:12]
[11:0]
[23:12]
[11:0]
[23:12]
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
XV1TOG1_3
XV1TOG2_3
XV1TOG3_3
XV2TOG1_3
XV2TOG2_3
XV2TOG3_3
XV3TOG1_3
XV3TOG2_3
XV3TOG3_3
XV4TOG1_3
XV4TOG2_3
XV4TOG3_3
XV5TOG1_3
XV5TOG2_3
XV5TOG3_3
XV6TOG1_3
XV6TOG2_3
XV6TOG3_3
FREEZE1_3
RESUME1_3
FREEZE2_3
RESUME2_3
26
27
28
29
2A
2B
2C
2D
2E
2F
Register Description
VPAT3 Start Polarity. XV1[0], XV2[1], XV3[2], XV4[3], XV5[4], XV6[5].
Unused.
Total Length of VPAT3. Note: If using VPAT3 as a second vertical
sequence in the VSG active line, this value is the start position for
the second vertical sequence.
XV1 Toggle Position 1.
XV1 Toggle Position 2.
XV1 Toggle Position 3.
XV2 Toggle Position 1.
XV2 Toggle Position 2.
XV2 Toggle Position 3.
XV3 Toggle Position 1.
XV3 Toggle Position 2.
XV3 Toggle Position 3.
XV4 Toggle Position 1.
XV4 Toggle Position 2.
XV4 Toggle Position 3.
XV5 Toggle Position 1.
XV5 Toggle Position 2.
XV5 Toggle Position 3.
XV6 Toggle Position 1.
XV6 Toggle Position 2.
XV6 Toggle Position 3.
XV1 to XV6 Freeze Position 1.
XV1 to XV6 Resume Position 1.
XV1 to XV6 Freeze Position 2.
XV1 to XV6 Resume Position 2.
Rev. A | Page 69 of 96
AD9925
Table 51. Vertical Pattern Group 4 (VPAT4) Register Map
Address
30
Data Bit Content
[5:0]
[11:6]
[23:12]
Default Value
X
X
X
Register Name
VPOL_4
UNUSED
VPATLEN_4
31
[11:0]
[23:12]
[11:0]
[23:12]
[11:0]
[23:12]
[11:0]
[23:12]
[11:0]
[23:12]
[11:0]
[23:12]
[11:0]
[23:12]
[11:0]
[23:12]
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
[11:0]
[23:12]
[11:0]
[23:12]
[11:0]
[23:12]
X
X
X
X
X
X
XV1TOG1_4
XV1TOG2_4
XV1TOG3_4
XV2TOG1_4
XV2TOG2_4
XV2TOG3_4
XV3TOG1_4
XV3TOG2_4
XV3TOG3_4
XV4TOG1_4
XV4TOG2_4
XV4TOG3_4
XV5TOG1_4
XV5TOG2_4
XV5TOG3_4
XV6TOG1_4
XV6TOG2_4
XV6TOG3_4
FREEZE1_4
RESUME1_4
FREEZE2_4
RESUME2_4
32
33
34
35
36
37
38
39
3A
3B
Register Description
VPAT4 Start Polarity. XV1[0], XV2[1], XV3[2], XV4[3], XV5[4], XV6[5].
Unused .
Total Length of VPAT4. Note: If using VPAT4 as a second vertical
sequence in the VSG active line, this value is the start position for
the second vertical sequence.
XV1 Toggle Position 1.
XV1 Toggle Position 2.
XV1 Toggle Position 3.
XV2 Toggle Position 1.
XV2 Toggle Position 2.
XV2 Toggle Position 3.
XV3 Toggle Position 1.
XV3 Toggle Position 2.
XV3 Toggle Position 3.
XV4 Toggle Position 1.
XV4 Toggle Position 2.
XV4 Toggle Position 3.
XV5 Toggle Position 1.
XV5 Toggle Position 2.
XV5 Toggle Position 3.
XV6 Toggle Position 1.
XV6 Toggle Position 2.
XV6 Toggle Position 3.
XV1 to XV6 Freeze Position 1.
XV1 to XV6 Resume Position 1.
XV1 to XV6 Freeze Position 2.
XV1 to XV6 Resume Position 2.
Rev. A | Page 70 of 96
AD9925
Table 52. Vertical Pattern Group 5 (VPAT5) Register Map
Address
3C
Data Bit Content
[5:0]
[11:6]
[23:12]
Default Value
X
X
X
Register Name
VPOL_5
UNUSED
VPATLEN_5
3D
[11:0]
[23:12]
[11:0]
[23:12]
[11:0]
[23:12]
[11:0]
[23:12]
[11:0]
[23:12]
[11:0]
[23:12]
[11:0]
[23:12]
[11:0]
[23:12]
[11:0]
[23:12]
[11:0]
[23:12]
[11:0]
[23:12]
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
XV1TOG1_5
XV1TOG2_5
XV1TOG3_5
XV2TOG1_5
XV2TOG2_5
XV2TOG3_5
XV3TOG1_5
XV3TOG2_5
XV3TOG3_5
XV4TOG1_5
XV4TOG2_5
XV4TOG3_5
XV5TOG1_5
XV5TOG2_5
XV5TOG3_5
XV6TOG1_5
XV6TOG2_5
XV6TOG3_5
FREEZE1_5
RESUME1_5
FREEZE2_5
RESUME2_5
3E
3F
40
41
42
43
44
45
46
47
Register Description
VPAT5 Start Polarity. XV1[0], XV2[1], XV3[2], XV4[3], XV5[4], XV6[5].
Unused.
Total Length of VPAT5. Note: If using VPAT5 as a second vertical
sequence in the VSG active line, this value is the start position for
the second vertical sequence.
XV1 Toggle Position 1.
XV1 Toggle Position 2.
XV1 Toggle Position 3.
XV2 Toggle Position 1.
XV2 Toggle Position 2.
XV2 Toggle Position 3.
XV3 Toggle Position 1.
XV3 Toggle Position 2.
XV3 Toggle Position 3.
XV4 Toggle Position 1.
XV4 Toggle Position 2.
XV4 Toggle Position 3.
XV5 Toggle Position 1.
XV5 Toggle Position 2.
XV5 Toggle Position 3.
XV6 Toggle Position 1.
XV6 Toggle Position 2.
XV6 Toggle Position 3.
XV1 to XV6 Freeze Position 1.
XV1 to XV6 Resume Position 1.
XV1 to XV6 Freeze Position 2.
XV1 to XV6 Resume Position 2.
Rev. A | Page 71 of 96
AD9925
Table 53. Vertical Pattern Group 6 (VPAT6) Register Map
Address
48
Data Bit Content
[5:0]
[11:6]
[23:12]
Default Value
X
X
X
Register Name
VPOL_6
UNUSED
VPATLEN_6
49
[11:0]
[23:12]
[11:0]
[23:12]
[11:0]
[23:12]
[11:0]
[23:12]
[11:0]
[23:12]
[11:0]
[23:12]
[11:0]
[23:12]
[11:0]
[23:12]
[11:0]
[23:12]
[11:0]
[23:12]
[11:0]
[23:12]
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
XV1TOG1_6
XV1TOG2_6
XV1TOG3_6
XV2TOG1_6
XV2TOG2_6
XV2TOG3_6
XV3TOG1_6
XV3TOG2_6
XV3TOG3_6
XV4TOG1_6
XV4TOG2_6
XV4TOG3_6
XV5TOG1_6
XV5TOG2_6
XV5TOG3_6
XV6TOG1_6
XV6TOG2_6
XV6TOG3_6
FREEZE1_6
RESUME1_6
FREEZE2_6
RESUME2_6
4A
4B
4C
4D
4E
4F
50
51
52
53
Register Description
VPAT6 Start Polarity. XV1[0], XV2[1], XV3[2], XV4[3], XV5[4], XV6[5].
Unused.
Total Length of VPAT6. Note: If using VPAT6 as a second vertical
sequence in the VSG Active line, this value is the start position for
the second vertical sequence.
XV1 Toggle Position 1.
XV1 Toggle Position 2.
XV1 Toggle Position 3.
XV2 Toggle Position 1.
XV2 Toggle Position 2.
XV2 Toggle Position 3.
XV3 Toggle Position 1.
XV3 Toggle Position 2.
XV3 Toggle Position 3.
XV4 Toggle Position 1.
XV4 Toggle Position 2.
XV4 Toggle Position 3.
XV5 Toggle Position 1.
XV5 Toggle Position 2.
XV5 Toggle Position 3.
XV6 Toggle Position 1.
XV6 Toggle Position 2.
XV6 Toggle Position 3.
XV1 to XV6 Freeze Position 1.
XV1 to XV6 Resume Position 1.
XV1 to XV6 Freeze Position 2.
XV1 to XV6 Resume Position 2.
Rev. A | Page 72 of 96
AD9925
Table 54. Vertical Pattern Group 7 (VPAT7) Register Map
Address
54
Data Bit Content
[5:0]
[11:6]
[23:12]
Default Value
X
X
X
Register Name
VPOL_7
UNUSED
VPATLEN_7
55
[11:0]
[23:12]
[11:0]
[23:12]
[11:0]
[23:12]
[11:0]
[23:12]
[11:0]
[23:12]
[11:0]
[23:12]
[11:0]
[23:12]
[11:0]
[23:12]
[11:0]
[23:12]
[11:0]
[23:12]
[11:0]
[23:12]
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
XV1TOG1_7
XV1TOG2_7
XV1TOG3_7
XV2TOG1_7
XV2TOG2_7
XV2TOG3_7
XV3TOG1_7
XV3TOG2_7
XV3TOG3_7
XV4TOG1_7
XV4TOG2_7
XV4TOG3_7
XV5TOG1_7
XV5TOG2_7
XV5TOG3_7
XV6TOG1_7
XV6TOG2_7
XV6TOG3_7
FREEZE1_7
RESUME1_7
FREEZE2_7
RESUME2_7
56
57
58
59
5A
5B
5C
5D
5E
5F
Register Description
VPAT7 Start Polarity. XV1[0], XV2[1], XV3[2], XV4[3], XV5[4], XV6[5].
Unused.
Total Length of VPAT7. Note: If using VPAT7 as a second vertical
sequence in the VSG active line, this value is the start position for
the second vertical sequence.
XV1 Toggle Position 1.
XV1 Toggle Position 2.
XV1 Toggle Position 3.
XV2 Toggle Position 1.
XV2 Toggle Position 2.
XV2 Toggle Position 3.
XV3 Toggle Position 1.
XV3 Toggle Position 2.
XV3 Toggle Position 3.
XV4 Toggle Position 1.
XV4 Toggle Position 2.
XV4 Toggle Position 3.
XV5 Toggle Position 1.
XV5 Toggle Position 2.
XV5 Toggle Position 3.
XV6 Toggle Position 1.
XV6 Toggle Position 2.
XV6 Toggle Position 3.
XV1 to XV6 Freeze Position 1.
XV1 to XV6 Resume Position 1.
XV1 to XV6 Freeze Position 2.
XV1 to XV6 Resume Position 2.
Rev. A | Page 73 of 96
AD9925
Table 55. Vertical Pattern Group 8 (VPAT8) Register Map
Address
60
Data Bit Content
[5:0]
[11:6]
[23:12]
Default Value
X
X
X
Register Name
VPOL_8
UNUSED
VPATLEN_8
61
[11:0]
[23:12]
[11:0]
[23:12]
[11:0]
[23:12]
[11:0]
[23:12]
[11:0]
[23:12]
[11:0]
[23:12]
[11:0]
[23:12]
[11:0]
[23:12]
[11:0]
[23:12]
[11:0]
[23:12]
[11:0]
[23:12]
[11:0]
[23:12]
[11:0]
[23:12]
[11:0]
[23:12]
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
XV1TOG1_8
XV1TOG2_8
XV1TOG3_8
XV1TOG4_8
XV2TOG1_8
XV2TOG2_8
XV2TOG3_8
XV2TOG4_8
XV3TOG1_8
XV3TOG2_8
XV3TOG3_8
XV3TOG4_8
XV4TOG1_8
XV4TOG2_8
XV4TOG3_8
XV4TOG4_8
XV5TOG1_8
XV5TOG2_8
XV5TOG3_8
XV5TOG4_8
XV6TOG1_8
XV6TOG2_8
XV6TOG3_8
XV6TOG4_8
FREEZE1_8
RESUME1_8
FREEZE2_8
RESUME2_8
UNUSED
62
63
64
65
66
67
68
69
6A
6B
6C
6D
6E
6F
Register Description
VPAT8 Start Polarity. XV1[0], XV2[1], XV3[2], XV4[3], XV5[4], XV6[5].
Unused.
Total Length of VPAT8. Note: If using VPAT8 as a second vertical
sequence in the VSG active line, this value is the start position for
the second vertical sequence.
XV1 Toggle Position 1.
XV1 Toggle Position 2.
XV1 Toggle Position 3.
XV1 Toggle Position 4.
XV2 Toggle Position 1.
XV2 Toggle Position 2.
XV2 Toggle Position 3.
XV2 Toggle Position 4.
XV3 Toggle Position 1.
XV3 Toggle Position 2.
XV3 Toggle Position 3.
XV3 Toggle Position 4.
XV4 Toggle Position 1.
XV4 Toggle Position 2.
XV4 Toggle Position 3.
XV4 Toggle Position 4.
XV5 Toggle Position 1.
XV5 Toggle Position 2.
XV5 Toggle Position 3.
XV5 Toggle Position 4.
XV6 Toggle Position 1.
XV6 Toggle Position 2.
XV6 Toggle Position 3.
XV6 Toggle Position 4.
XV1 to XV6 Freeze Position 1.
XV1 to XV6 Resume Position 1.
XV1 to XV6 Freeze Position 2.
XV1 to XV6 Resume Position 2.
Unused.
Rev. A | Page 74 of 96
AD9925
Table 56. Vertical Pattern Group 9 (VPAT9) Register Map
Address
70
Data Bit Content
[5:0]
[11:6]
[23:12]
Default Value
X
X
X
Register Name
VPOL_9
UNUSED
VPATLEN_9
71
[11:0]
[23:12]
[11:0]
[23:12]
[11:0]
[23:12]
[11:0]
[23:12]
[11:0]
[23:12]
[11:0]
[23:12]
[11:0]
[23:12]
[11:0]
[23:12]
[11:0]
[23:12]
[11:0]
[23:12]
[11:0]
[23:12]
[11:0]
[23:12]
[11:0]
[23:12]
[11:0]
[23:12]
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
XV1TOG1_9
XV1TOG2_9
XV1TOG3_9
XV1TOG4_9
XV2TOG1_9
XV2TOG2_9
XV3TOG3_9
XV3TOG4_9
XV3TOG1_9
XV4TOG2_9
XV4TOG3_9
XV4TOG4_9
XV5TOG1_9
XV5TOG2_9
XV5TOG3_9
XV6TOG4_9
XV6TOG1_9
XV6TOG2_9
XV6TOG3_9
XV6TOG4_9
XV6TOG1_9
XV6TOG2_9
XV6TOG3_9
XV6TOG4_9
FREEZE1_9
RESUME1_9
FREEZE2_9
RESUME2_9
72
73
74
75
76
77
78
79
7A
7B
7C
7D
7E
Register Description
VPAT9 Start Polarity. XV1[0], XV2[1], XV3[2], XV4[3], XV5[4], XV6[5].
Unused.
Total Length of VPAT9. Note: If using VPAT9 as a second vertical
sequence in the VSG active line, this value is the start position for
the second vertical sequence.
XV1 Toggle Position 1.
XV1 Toggle Position 2.
XV1 Toggle Position 3.
XV1 Toggle Position 4.
XV2 Toggle Position 1.
XV2 Toggle Position 2.
XV2 Toggle Position 3.
XV2 Toggle Position 4.
XV3 Toggle Position 1.
XV3 Toggle Position 2.
XV3 Toggle Position 3.
XV3 Toggle Position 4.
XV4 Toggle Position 1.
XV4 Toggle Position 2.
XV4 Toggle Position 3.
XV4 Toggle Position 4.
XV5 Toggle Position 1.
XV5 Toggle Position 2.
XV5 Toggle Position 3.
XV5 Toggle Position 4.
XV6 Toggle Position 1.
XV6 Toggle Position 2.
XV6 Toggle Position 3.
XV6 Toggle Position 4.
XV1 to XV6 Freeze Position 1.
XV1 to XV6 Resume Position 1.
XV1 to XV6 Freeze Position 2.
XV1 to XV6 Resume Position 2.
Table 57. Register Map Selection (SCK Updated Register)
Address
7F
Data Bit Content
[1:0]
Default Value
0
Register Name
BANKSELECT
Register Description
Register Bank Access for Bank 1, Bank 2, and Bank 3.
Rev. A | Page 75 of 96
AD9925
Table 58. Vertical Sequence 0 (VSEQ0) Register Map
Address
80
81
82
83
84
85
86
87
Data Bit Content
[1:0]
[2]
[3]
[7:4]
[9:8]
Default Value
X
X
X
X
X
Register Name
HBLKMASK_0
CLPOBPOL_0
PBLKPOL_0
VPATSEL_0
VMASK_0
[11:10]
[12]
[23:12]
[11:0]
[23:12]
X
X
X
X
HBLKALT_0
HDLEN13_0
UNUSED
VPATREPO_0
VPATREPE_0
[11:0]
[23:12]
[11:0]
[23:12]
[11:0]
[23:12]
[11:0]
[23:12]
[11:0]
[23:12]
[11:0]
[23:12]
X
X
X
X
X
X
X
X
X
X
X
X
VPATSTART_0
HDLEN_0
PBLKTOG1_0
PBLKTOG2_0
HBLKTOG1_0
HBLKTOG2_0
HBLKTOG3_0
HBLKTOG4_0
HBLKTOG5_0
HBLKTOG6_0
CLPOBTOG1_0
CLPOBTOG2_0
Register Description
Masking Polarity during HBLK. H1 [0], H3 [1].
CLPOB Start Polarity.
PBLK Start Polarity.
Selected Vertical Pattern Group for Vertical Sequence 0.
Enable Masking of Vertical Outputs (Specified by FREEZE/RESUME
Registers).
Enable HBLK Alternation.
13th Bit for HD Length Counter Allows HD Length up to 8191 Pixels.
Unused.
Number of Selected Vertical Pattern Group Repetitions for Odd Lines.
Number of Selected Vertical Pattern Group Repetitions for Even
Lines.
Start Position in the Line for the Selected Vertical Pattern Group.
HD Line Length (Number of Pixels) for Vertical Sequence 0.
PBLK Toggle Position 1 for Vertical Sequence 0.
PBLK Toggle Position 2 for Vertical Sequence 0.
HBLK Toggle Position 1 for Vertical Sequence 0.
HBLK Toggle Position 2 for Vertical Sequence 0.
HBLK Toggle Position 3 for Vertical Sequence 0.
HBLK Toggle Position 4 for Vertical Sequence 0.
HBLK Toggle Position 5 for Vertical Sequence 0.
HBLK Toggle Position 6 for Vertical Sequence 0.
CLPOB Toggle Position 1 for Vertical Sequence 0.
CLPOB Toggle Position 2 for Vertical Sequence 0.
Table 59. Vertical Sequence 1 (VSEQ1) Register Map
Address
88
89
8A
8B
8C
8D
8E
8F
Data Bit Content
[1:0]
[2]
[3]
[7:4]
[9:8]
Default Value
X
X
X
X
X
Register Name
HBLKMASK_1
CLPOBPOL_1
PBLKPOL_1
VPATSEL_1
VMASK_1
[11:10]
[12]
[23:12]
[11:0]
[23:12]
[11:0]
[23:12]
[11:0]|
[23:12]
[11:0]
[23:12]
[11:0]
[23:12]
[11:0]
[23:12]
[11:0]
[23:12]
X
X
HBLKALT_1
HDLEN13_1
UNUSED
VPATREPO_1
VPATREPE_1
VPATSTART_1
HDLEN_1
PBLKTOG1_1
PBLKTOG2_1
HBLKTOG1_1
HBLKTOG2_1
HBLKTOG3_1
HBLKTOG4_1
HBLKTOG5_1
HBLKTOG6_1
CLPOBTOG1_1
CLPOBTOG2_1
X
X
X
X
X
X
X
X
X
X
X
X
X
X
Register Description
Masking Polarity during HBLK. H1 [0], H3 [1].
CLPOB Start Polarity.
PBLK Start Polarity.
Selected Vertical Pattern Group for Vertical Sequence 1.
Enable Masking of Vertical Outputs (Specified by FREEZE/RESUME
Registers).
Enable HBLK Alternation.
13th Bit for HD Length Counter Allows HD Length up to 8191 Pixels.
Unused.
Number of Selected Vertical Pattern Group Repetitions for Odd Lines.
Number of Selected Vertical Pattern Group Repetitions for Even Lines.
Start Position in the Line for the Selected Vertical Pattern Group.
HD Line Length (Number of Pixels) for Vertical Sequence 1.
PBLK Toggle Position 1 for Vertical Sequence 1.
PBLK Toggle Position 2 for Vertical Sequence 1.
HBLK Toggle Position 1 for Vertical Sequence 1.
HBLK Toggle Position 2 for Vertical Sequence 1.
HBLK Toggle Position 3 for Vertical Sequence 1.
HBLK Toggle Position 4 for Vertical Sequence 1.
HBLK Toggle Position 5 for Vertical Sequence 1.
HBLK Toggle Position 6 for Vertical Sequence 1.
CLPOB Toggle Position 1 for Vertical Sequence 1.
CLPOB Toggle Position 2 for Vertical Sequence 1.
Rev. A | Page 76 of 96
AD9925
Table 60. Vertical Sequence 2 (VSEQ2) Register Map
Address
90
91
92
93
94
95
96
97
Data Bit Content
[1:0]
[2]
[3]
[7:4]
[9:8]
[11:10]
[12]
[23:12]
[11:0]
[23:12]
[11:0]
[23:12]
[11:0]
[23:12]
[11:0]
[23:12]
[11:0]
[23:12]
[11:0]
[23:12]
[11:0]
[23:12]
Default Value
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
Register Name
HBLKMASK_2
CLPOBPOL_2
PBLKPOL_2
VPATSEL_2
VMASK_2
HBLKALT_2
HDLEN13_2
UNUSED
VPATREPO_2
VPATREPE_2
VPATSTART_2
HDLEN_2
PBLKTOG1_2
PBLKTOG2_2
HBLKTOG1_2
HBLKTOG2_2
HBLKTOG3_2
HBLKTOG4_2
HBLKTOG5_2
HBLKTOG6_2
CLPOBTOG1_2
CLPOBTOG2_2
Register Description
Masking Polarity during HBLK. H1 [0], H3 [1].
CLPOB Start Polarity.
PBLK Start Polarity.
Selected Vertical Pattern Group for Vertical Sequence 2.
Enable Masking of Vertical Outputs (Specified by FREEZE/RESUME Registers).
Enable HBLK Alternation .
13th Bit for HD Length Counter Allows HD Length up to 8191 Pixels.
Unused.
Number of Selected Vertical Pattern Group Repetitions for Odd Lines.
Number of Selected Vertical Pattern Group Repetitions for Even Lines.
Start Position in the Line for the Selected Vertical Pattern Group.
HD Line Length (Number of Pixels) for Vertical Sequence 2.
PBLK Toggle Position 1 for Vertical Sequence 2.
PBLK Toggle Position 2 for Vertical Sequence 2.
HBLK Toggle Position 1 for Vertical Sequence 2.
HBLK Toggle Position 2 for Vertical Sequence 2.
HBLK Toggle Position 3 for Vertical Sequence 2.
HBLK Toggle Position 4 for Vertical Sequence 2.
HBLK Toggle Position 5 for Vertical Sequence 2.
HBLK Toggle Position 6 for Vertical Sequence 2.
CLPOB Toggle Position 1 for Vertical Sequence 2.
CLPOB Toggle Position 2 for Vertical Sequence 2.
Table 61. Vertical Sequence 3 (VSEQ3) Register Map
Address
98
99
9A
9B
9C
9D
9E
9F
Data Bit Content
[1:0]
[2]
[3]
[7:4]
[9:8]
[11:10]
[12]
[23:12]
[11:0]
[23:12]
[11:0]
[23:12]
[11:0]
[23:12]
[11:0]
[23:12]
[11:0]
[23:12]
[11:0]
[23:12]
[11:0]
[23:12]
Default Value
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
Register Name
HBLKMASK_3
CLPOBPOL_3
PBLKPOL_3
VPATSEL_3
VMASK_3
HBLKALT_3
HDLEN13_3
UNUSED
VPATREPO_3
VPATREPE_3
VPATSTART_3
HDLEN_3
PBLKTOG1_3
PBLKTOG2_3
HBLKTOG1_3
HBLKTOG2_3
HBLKTOG3_3
HBLKTOG4_3
HBLKTOG5_3
HBLKTOG6_3
CLPOBTOG1_3
CLPOBTOG2_3
Register Description
Masking Polarity during HBLK. H1 [0], H3 [1].
CLPOB Start Polarity.
PBLK Start Polarity.
Selected Vertical Pattern Group for Vertical Sequence 3.
Enable Masking of Vertical Outputs (Specified by FREEZE/RESUME Registers).
Enable HBLK Alternation
13th Bit for HD Length Counter Allows HD Length up to 8191 Pixels.
Unused.
Number of Selected Vertical Pattern Group Repetitions for Odd Lines.
Number of Selected Vertical Pattern Group Repetitions for Even Lines.
Start Position in the Line for the Selected Vertical Pattern Group.
HD Line Length (Number of Pixels) for Vertical Sequence 3.
PBLK Toggle Position 1 for Vertical Sequence 3.
PBLK Toggle Position 2 for Vertical Sequence 3.
HBLK Toggle Position 1 for Vertical Sequence 3.
HBLK Toggle Position 2 for Vertical Sequence 3.
HBLK Toggle Position 3 for Vertical Sequence 3.
HBLK Toggle Position 4 for Vertical Sequence 3.
HBLK Toggle Position 5 for Vertical Sequence 3.
HBLK Toggle Position 6 for Vertical Sequence 3.
CLPOB Toggle Position 1 for Vertical Sequence 3.
CLPOB Toggle Position 2 for Vertical Sequence 3.
Rev. A | Page 77 of 96
AD9925
Table 62. Vertical Sequence 4 (VSEQ4) Register Map
Address
A0
A1
A2
A3
A4
A5
A6
A7
Data Bit Content
[1:0]
[2]
[3]
[7:4]
[9:8]
Default Value
X
X
X
X
X
Register Name
HBLKMASK_4
CLPOBPOL_4
PBLKPOL_4
VPATSEL_4
VMASK_4
[11:10]
[12]
[23:12]
[11:0]
X
X
X
HBLKALT_4
HDLEN13_4
UNUSED
VPATREPO_4
[23:12]
X
VPATREPE_4
[11:0]
[23:12]
[11:0]
[23:12]
[11:0]
[23:12]
[11:0]
[23:12]
[11:0]
[23:12]
[11:0]
[23:12]
X
X
X
X
X
X
X
X
X
X
X
X
VPATSTART_4
HDLEN_4
PBLKTOG1_4
PBLKTOG2_4
HBLKTOG1_4
HBLKTOG2_4
HBLKTOG3_4
HBLKTOG4_4
HBLKTOG5_4
HBLKTOG6_4
CLPOBTOG1_4
CLPOBTOG2_4
Register Description
Masking Polarity during HBLK. H1 [0], H3 [1].
CLPOB Start Polarity.
PBLK Start Polarity.
Selected Vertical Pattern Group for Vertical Sequence 4.
Enable Masking of Vertical Outputs (Specified by FREEZE/RESUME
Registers).
Enable HBLK Alternation.
13th Bit for HD Length Counter Allows HD Length up to 8191 Pixels.
Unused.
Number of Selected Vertical Pattern Group Repetitions for Odd
Lines.
Number of Selected Vertical Pattern Group Repetitions for Even
Lines.
Start Position in the Line for the Selected Vertical Pattern Group.
HD Line Length (Number of Pixels) for Vertical Sequence 4.
PBLK Toggle Position 1 for Vertical Sequence 4.
PBLK Toggle Position 2 for Vertical Sequence 4.
HBLK Toggle Position 1 for Vertical Sequence 4.
HBLK Toggle Position 2 for Vertical Sequence 4.
HBLK Toggle Position 3 for Vertical Sequence 4.
HBLK Toggle Position 4 for Vertical Sequence 4.
HBLK Toggle Position 5 for Vertical Sequence 4.
HBLK Toggle Position 6 for Vertical Sequence 4.
CLPOB Toggle Position 1 for Vertical Sequence 4.
CLPOB Toggle Position 2 for Vertical Sequence 4.
Table 63. Vertical Sequence 5 (VSEQ5)Register Map
Address
A8
A9
AA
AB
AC
AD
AE
AF
Data Bit Content
[1:0]
[2]
[3]
[7:4]
[9:8]
Default Value
X
X
X
X
X
Register Name
HBLKMASK_5
CLPOBPOL_5
PBLKPOL_5
VPATSEL_5
VMASK_5
[11:10]
[12]
[23:12]
[11:0]
X
X
X
HBLKALT_5
HDLEN13_5
UNUSED
VPATREPO_5
[23:12]
X
VPATREPE_5
[11:0]
[23:12]
[11:0]
[23:12]
[11:0]
[23:12]
[11:0]
[23:12]
[11:0]
[23:12]
[11:0]
[23:12]
X
X
X
X
X
X
X
X
X
X
X
X
VPATSTART_5
HDLEN_5
PBLKTOG1_5
PBLKTOG2_5
HBLKTOG1_5
HBLKTOG2_5
HBLKTOG3_5
HBLKTOG4_5
HBLKTOG5_5
HBLKTOG6_5
CLPOBTOG1_5
CLPOBTOG2_5
Register Description
Masking Polarity during HBLK. H1 [0], H3 [1].
CLPOB Start Polarity.
PBLK Start Polarity.
Selected Vertical Pattern Group for Vertical Sequence 5.
Enable Masking of Vertical Outputs (Specified by FREEZE/RESUME
registers).
Enable HBLK Alternation.
13th Bit for HD Length Counter Allows HD Length up to 8191 Pixels.
Unused.
Number of Selected Vertical Pattern Group Repetitions for Odd
Lines.
Number of Selected Vertical Pattern Group Repetitions for Even
Lines.
Start Position in the Line for the Selected Vertical Pattern Group.
HD Line Length (Number of Pixels) for Vertical Sequence 5.
PBLK Toggle Position 1 for Vertical Sequence 5.
PBLK Toggle Position 2 for Vertical Sequence 5.
HBLK Toggle Position 1 for Vertical Sequence 5.
HBLK Toggle Position 2 for Vertical Sequence 5.
HBLK Toggle Position 3 for Vertical Sequence 5.
HBLK Toggle Position 4 for Vertical Sequence 5.
HBLK Toggle Position 5 for Vertical Sequence 5.
HBLK Toggle Position 6 for Vertical Sequence 5.
CLPOB Toggle Position 1 for Vertical Sequence 5.
CLPOB Toggle Position 2 for Vertical Sequence 5.
Rev. A | Page 78 of 96
AD9925
Table 64. Vertical Sequence 6 (VSEQ6) Register Map
Address
B0
B1
B2
B3
B4
B5
B6
B7
Data Bit Content
[1:0]
[2]
[3]
[7:4]
[9:8]
Default Value
X
X
X
X
X
Register Name
HBLKMASK_6
CLPOBPOL_6
PBLKPOL_6
VPATSEL_6
VMASK_6
[11:10]
[12]
[23:12]
[11:0]
[23:12]
[11:0]
[23:12]
[11:0]
[23:12]
[11:0]
[23:12]
[11:0]
[23:12]
[11:0]
[23:12]
[11:0]
[23:12]
X
X
HBLKALT_6
HDLEN13_6
UNUSED
VPATREPO_6 V
PATREPE_6
VPATSTART_6
HDLEN_6
PBLKTOG1_6
PBLKTOG2_6
HBLKTOG1_6
HBLKTOG2_6
HBLKTOG3_6
HBLKTOG4_6
HBLKTOG5_6
HBLKTOG6_6
CLPOBTOG1_6
CLPOBTOG2_6
X
X
X
X
X
X
X
X
X
X
X
X
X
X
Register Description
Masking Polarity during HBLK. H1 [0], H3 [1].
CLPOB Start Polarity.
PBLK Start Polarity.
Selected Vertical Pattern Group for Vertical Sequence 6.
Enable Masking of Vertical outputs (specified by FREEZE/RESUME
registers).
Enable HBLK Alternation.
13th Bit for HD Length Counter Allows HD Length up to 8191 Pixels.
Unused.
Number of Selected Vertical Pattern Group Repetitions for Odd Lines.
Number of Selected Vertical Pattern Group Repetitions for Even Lines.
Start Position in the Line for the Selected Vertical Pattern Group.
HD Line Length (Number of Pixels) for Vertical Sequence 6.
PBLK Toggle Position 1 for Vertical Sequence 6.
PBLK Toggle Position 2 for Vertical Sequence 6.
HBLK Toggle Position 1 for Vertical Sequence 6.
HBLK Toggle Position 2 for Vertical Sequence 6.
HBLK Toggle Position 3 for Vertical Sequence 6.
HBLK Toggle Position 4 for Vertical Sequence 6.
HBLK Toggle Position 5 for Vertical Sequence 6.
HBLK Toggle Position 6 for Vertical Sequence 6.
CLPOB Toggle Position 1 for Vertical Sequence 6.
CLPOB Toggle Position 2 for Vertical Sequence 6.
Table 65. Vertical Sequence 7 (VSEQ7) Register Map
Address
B8
B9
BA
BB
BC
BD
BE
BF
Data Bit Content
[1:0]
[2]
[3]
[7:4]
[9:8]
[11:10]
[12]
[23:12]
[11:0]
[23:12]
[11:0]
[23:12]
[11:0]
[23:12]
[11:0]
[23:12]
[11:0]
[23:12]
[11:0]
[23:12]
[11:0]
[23:12]
Default Value
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
Register Name
HBLKMASK_7
CLPOBPOL_7
PBLKPOL_7
VPATSEL_7
VMASK_7
HBLKALT_7
HDLEN13_7
UNUSED
VPATREPO_7
VPATREPE_7
VPATSTART_7
HDLEN_7
PBLKTOG1_7
PBLKTOG2_7
HBLKTOG1_7
HBLKTOG2_7
HBLKTOG3_7
HBLKTOG4_7
HBLKTOG5_7
HBLKTOG6_7
CLPOBTOG1_7
CLPOBTOG2_7
Register Description
Masking Polarity during HBLK. H1 [0], H3 [1].
CLPOB Start Polarity.
PBLK Start Polarity.
Selected Vertical Pattern Group for Vertical Sequence 7.
Enable Masking of Vertical Outputs (Specified by FREEZE/RESUME Registers).
Enable HBLK Alternation.
13th Bit for HD Length Counter Allows HD Length up to 8191 Pixels.
Unused.
Number of Selected Vertical Pattern Group Repetitions for Odd Lines.
Number of Selected Vertical Pattern Group Repetitions for Even Lines.
Start Position in the Line for the Selected Vertical Pattern Group.
HD Line Length (Number of Pixels) for Vertical Sequence 7.
PBLK Toggle Position 1 for Vertical Sequence 7.
PBLK Toggle Position 2 for Vertical Sequence 7.
HBLK Toggle Position 1 for Vertical Sequence 7.
HBLK Toggle Position 2 for Vertical Sequence 7.
HBLK Toggle Position 3 for Vertical Sequence 7.
HBLK Toggle Position 4 for Vertical Sequence 7.
HBLK Toggle Position 5 for Vertical Sequence 7.
HBLK Toggle Position 6 for Vertical Sequence 7.
CLPOB Toggle Position 1 for Vertical Sequence 7.
CLPOB Toggle Position 2 for Vertical Sequence 7.
Rev. A | Page 79 of 96
AD9925
Table 66. Vertical Sequence 8 (VSEQ8) Register Map
Address
C0
C1
C2
C3
C4
C5
C6
C7
Data Bit Content
[1:0]
[2]
[3]
[7:4]
[9:8]
Default Value
X
X
X
X
X
Register Name
HBLKMASK_8
CLPOBPOL_8
PBLKPOL_8
VPATSEL_8
VMASK_8
[11:10]
[12]
[23:12]
[11:0]
[23:12]
[11:0]
[23:12]
X
X
X
X
X
X
HBLKALT_8
HDLEN13_8
UNUSED
VPATREPO_8
VPATREPE_8
VPATSTART_8
HDLEN_8
[11:0]
[23:12]
[11:0]
[23:12]
[11:0]
[23:12]
[11:0]
[23:12]
[11:0]
[23:12]
X
X
X
X
X
X
X
X
X
X
PBLKTOG1_8
PBLKTOG2_8
HBLKTOG1_8
HBLKTOG2_8
HBLKTOG3_8
HBLKTOG4_8
HBLKTOG5_8
HBLKTOG6_8
CLPOBTOG1_8
CLPOBTOG2_8
Register Description
Masking Polarity during HBLK. H1 [0], H3 [1].
CLPOB Start Polarity.
PBLK Start Polarity.
Selected Vertical Pattern Group for Vertical Sequence 8.
Enable Masking of Vertical Outputs (Specified by FREEZE/RESUME
Registers).
Enable HBLK Alternation.
13th Bit for HD Length Counter Allows HD Length up to 8191 Pixels.
Unused.
Number of Selected Vertical Pattern Group Repetitions for Odd Lines.
Number of Selected Vertical Pattern Group Repetitions for Even Lines.
Start Position in the Line for the Selected Vertical Pattern Group.
HD Line Length (Number of Pixels) for Vertical Sequence 8.
PBLK Toggle Position 1 for Vertical Sequence 8.
PBLK Toggle Position 2 for Vertical Sequence 8.
HBLK Toggle Position 1 for Vertical Sequence 8.
HBLK Toggle Position 2 for Vertical Sequence 8.
HBLK Toggle Position 3 for Vertical Sequence 8.
HBLK Toggle Position 4 for Vertical Sequence 8.
HBLK Toggle Position 5 for Vertical Sequence 8.
HBLK Toggle Position 6 for Vertical Sequence 8.
CLPOB Toggle Position 1 for Vertical Sequence 8.
CLPOB Toggle Position 2 for Vertical Sequence 8.
Table 67. Vertical Sequence 9 (VSEQ9) Register Map
Address
C8
C9
CA
CB
CC
CD
CE
CF
Data Bit Content
[1:0]
[2]
[3]
[7:4]
[9:8]
Default Value
X
X
X
X
X
Register Name
HBLKMASK_9
CLPOBPOL_9
PBLKPOL_9
VPATSEL_9
VMASK_9
[11:10]
[12]
[23:12]
[11:0]
X
X
X
HBLKALT_9
HDLEN13_9
UNUSED
VPATREPO_9
[23:12]
X
VPATREPE_9
[11:0]
[23:12]
[11:0]
[23:12]
[11:0]
[23:12]
[11:0]
[23:12]
[11:0]
[23:12]
[11:0]
[23:12]
X
X
X
X
X
X
X
X
X
X
X
X
VPATSTART_9
HDLEN_9
PBLKTOG1_9
PBLKTOG2_9
HBLKTOG1_9
HBLKTOG2_9
HBLKTOG3_9
HBLKTOG4_9
HBLKTOG5_9
HBLKTOG6_9
CLPOBTOG1_9
CLPOBTOG2_9
Register Description
Masking Polarity during HBLK. H1 [0], H3 [1].
CLPOB Start Polarity.
PBLK Start Polarity.
Selected Vertical Pattern Group for Vertical Sequence 9.
Enable Masking of Vertical Outputs (Specified by FREEZE/RESUME
registers).
Enable HBLK Alternation.
13th Bit for HD Length Counter Allows HD Length up to 8191 Pixels.
Unused.
Number of Selected Vertical Pattern Group Repetitions for Odd
Lines.
Number of Selected Vertical Pattern Group Repetitions for Even
Lines.
Start Position in the Line for the Selected Vertical Pattern Group.
HD Line Length (Number of Pixels) for Vertical Sequence 9.
PBLK Toggle Position 1 for Vertical Sequence 9.
PBLK Toggle Position 2 for Vertical Sequence 9.
HBLK Toggle Position 1 for Vertical Sequence 9.
HBLK Toggle Position 2 for Vertical Sequence 9.
HBLK Toggle Position 3 for Vertical Sequence 9.
HBLK Toggle Position 4 for Vertical Sequence 9.
HBLK Toggle Position 5 for Vertical Sequence 9.
HBLK Toggle Position 6 for Vertical Sequence 9.
CLPOB Toggle Position 1 for Vertical Sequence 9.
CLPOB Toggle Position 2 for Vertical Sequence 9.
Rev. A | Page 80 of 96
AD9925
Table 68. Field 0 Register Map
Address
D0
D1
D2
D3
D4
D5
D6
D7
Data Bit Content
[3:0]
[4]
[5]
[9:6]
[10]
[11]
[15:12]
[16]
[17]
[21:18]
[22]
[23]
[3:0]
[4]
[5]
[9:6]
[10]
[11]
[15:12]
[16]
[17]
[23:18]
[11:0]
[23:12]
[11:0]
[23:12]
[11:0]
[23:12]
[3:0]
[9:4]
[21:10]
[22]
[11:0]
[23:12]
Default Value
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
Register Name
VSEQSEL0_0
SWEEP0_0
MULTI0_0
VSEQSEL1_0
SWEEP1_0
MULTI1_0
VSEQSEL2_0
SWEEP2_0
MULTI2_0
VSEQSEL3_0
SWEEP3_0
MULTI3_0
VSEQSEL4_0
SWEEP4_0
MULTI4_0
VSEQSEL5_0
SWEEP5_0
MULTI5_0
VSEQSEL6_0
SWEEP6_0
MULTI6_0
UNUSED
SCP1_0
SCP2_0
SCP3_0
SCP4_0
VDLEN_0
HDLAST_0
VPATSECOND_0
SGMASK_0
SGPATSEL_0
HDLAST13_0
SGLINE1_0
SGLINE2_0
[11:0]
[23:12]
X
X
SCP5_0
SCP6_0
X
X
X
X
X
X
X
X
Register Description
Selected Vertical Sequence for Region 0.
Select Sweep Region for Region 0. 0 = No Sweep, 1 = Sweep.
Select Multiplier Region for Region 0. 0 = No Multiplier, 1 = Multiplier.
Selected Vertical Sequence for Region 1.
Select Sweep Region for Region 1. 0 = No Sweep, 1 = Sweep.
Select Multiplier Region for Region 1. 0 = No Multiplier, 1 = Multiplier.
Selected Vertical Sequence for Region 2.
Select Sweep Region for Region 2. 0 = No Sweep, 1 = Sweep.
Select Multiplier Region for Region 2. 0 = No Multiplier, 1 = Multiplier.
Selected Vertical Sequence for Region 3.
Select Sweep Region for Region 3. 0 = No Sweep, 1 = Sweep.
Select Multiplier Region for Region 3. 0 = No Multiplier, 1 = Multiplier.
Selected Vertical Sequence for Region 4.
Select Sweep Region for Region 4. 0 = No Sweep, 1 = Sweep.
Select Multiplier Region for Region 4. 0 = No Multiplier, 1 = Multiplier.
Selected Vertical Sequence for Region 5.
Select Sweep Region for Region 5. 0 = No Sweep, 1 = Sweep.
Select Multiplier Region for Region 5. 0 = No Multiplier, 1 = Multiplier.
Selected Vertical Sequence for Region 6.
Select Sweep Region for Region 6. 0 = No Sweep, 1 = Sweep.
Select Multiplier Region for Region 6. 0 = No Multiplier, 1 = Multiplier.
Unused.
Vertical Sequence Change Position No. 1 for Field 0.
Vertical Sequence Change Position No. 2 for Field 0.
Vertical Sequence Change Position No. 3 for Field 0.
Vertical Sequence Change Position No. 4 for Field 0.
VD Field Length (Number of Lines) for Field 0.
HD Line Length (Number of Pixels) for Last Line in Field 0.
Selected Second Vertical Pattern Group for VSG Active Line.
Masking of VSG Outputs during VSG Active Line.
Selection of VSG Patterns for Each VSG Output.
MSB for 13-Bit Last Line Length
VSG Active Line 1.
VSG Active Line 2
(If No Second Line Is Needed, Set to Same as Line 1 or Maximum).
Vertical Sequence Change Position No. 5 for Field 0.
Vertical Sequence Change Position No. 6 for Field 0.
Rev. A | Page 81 of 96
AD9925
Table 69. Field 1 Register Map
Address
D8
D9
DA
DB
DC
DD
DE
DF
Data Bit Content
[3:0]
[4]
[5]
[9:6]
[10]
[11]
[15:12]
[16]
[17]
[21:18]
[22]
[23]
[3:0]
[4]
[5]
[9:6]
[10]
[11]
[15:12]
[16]
[17]
[23:18]
[11:0]
[23:12]
[11:0]
[23:12]
[11:0]
[23:12]
[3:0]
[9:4]
[21:10]
[22]
[11:0]
[23:12]
Default Value
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
Register Name
VSEQSEL0_1
SWEEP0_1
MULTI0_1
VSEQSEL1_1
SWEEP1_1
MULTI1_1
VSEQSEL2_1
SWEEP2_1
MULTI2_1
VSEQSEL3_1
SWEEP3_1
MULTI3_1
VSEQSEL4_1
SWEEP4_1
MULTI4_1
VSEQSEL5_1
SWEEP5_1
MULTI5_1
VSEQSEL6_1
SWEEP6_1
MULTI6_1
UNUSED
SCP1_1
SCP2_1
SCP3_1
SCP4_1
VDLEN_1
HDLAST_1
VPATSECOND_1
SGMASK_1
SGPATSEL_1
HDLAST13_1
SGLINE1_1
SGLINE2_1
[11:0]
[23:12]
X
X
SCP5_1
SCP6_1
Register Description
Selected Vertical Sequence for Region 0.
Select Sweep Region for Region 0. 0 = No Sweep, 1 = Sweep.
Select Multiplier Region for Region 0. 0 = No Multiplier, 1 = Multiplier.
Selected Vertical Sequence for Region 1.
Select Sweep Region for Region 1. 0 = No Sweep, 1 = Sweep.
Select Multiplier Region for Region 1. 0 = No Multiplier, 1 = Multiplier.
Selected Vertical Sequence for Region 2.
Select Sweep Region for Region 2. 0 = No Sweep, 1 = Sweep.
Select Multiplier Region for Region 2. 0 = No Multiplier, 1 = Multiplier.
Selected Vertical Sequence for Region 3.
Select Sweep Region for Region 3. 0 = No Sweep, 1 = Sweep.
Select Multiplier Region for Region 3. 0 = No Multiplier, 1 = Multiplier.
Selected Vertical Sequence for Region 4.
Select Sweep Region for Region 4. 0 = No Sweep, 1 = Sweep.
Select Multiplier Region for Region 4. 0 = No Multiplier, 1 = Multiplier.
Selected Vertical Sequence for Region 5.
Select Sweep Region for Region 5. 0 = No Sweep, 1 = Sweep.
Select Multiplier Region for Region 5. 0 = No Multiplier, 1 = Multiplier.
Selected Vertical Sequence for Region 6.
Select Sweep Region for Region 6. 0 = No Sweep, 1 = Sweep.
Select Multiplier Region for Region 6. 0 = No Multiplier, 1 = Multiplier. Unused.
Vertical Sequence Change Position No. 1 for Field 1.
Vertical Sequence Change Position No. 2 for Field 1.
Vertical Sequence Change Position No. 3 for Field 1.
Vertical Sequence Change Position No. 4 for Field 1.
VD Field Length (Number of Lines) for Field 1.
HD Line Length (Number of Pixels) for Last Line in Field 1.
Selected Second Vertical Pattern Group for VSG Active Line.
Masking of VSG Outputs during VSG Active Line.
Selection of VSG Patterns for Each VSG Output.
MSB for 13-Bit Last Line Length
VSG Active Line 1.
VSG Active Line 2.
(If No Second Line Is Needed, Set to Same as Line 1 or Maximum).
Vertical Sequence Change Position No. 5 for Field 1.
Vertical Sequence Change Position No. 6 for Field 1.
Rev. A | Page 82 of 96
AD9925
Table 70. Field 2 Register Map
Address
E0
E1
E2
E3
E4
E5
E6
E7
Data Bit Content
[3:0]
[4]
[5]
[9:6]
[10]
[11]
[15:12]
[16]
[17]
[21:18]
[22]
[23]
[3:0]
[4]
[5]
[9:6]
[10]
[11]
[15:12]
[16]
[17]
[23:18]
[11:0]
[23:12]
[11:0]
[23:12]
[11:0]
[23:12]
[3:0]
[9:4]
[21:10]
[22]
[11:0]
[23:12]
Default Value
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
Register Name
VSEQSEL_2
SWEEP0_2
MULTI0_2
VSEQSEL1_2
SWEEP1_2
MULTI1_2
VSEQSEL2_2
SWEEP2_2
MULTI2_2
VSEQSEL3_2
SWEEP3_2
MULTI3_2
VSEQSEL4_2
SWEEP4_2
MULTI4_2
VSEQSEL5_2
SWEEP5_2
MULTI5_2
VSEQSEL6_2
SWEEP6_2
MULTI6_2
UNUSED
SCP1_2
SCP2_2
SCP3_2
SCP4_2
VDLEN0_2
HDLAST_2
VPATSECOND_2
SGMASK_2
SGPATSEL_2
HDLAST13_2
SGLINE1_2
SGLINE2_2
[11:0]
[23:12]
X
X
SCP5_2
SCP6_2
Register Description
Selected Vertical Sequence for Region 0 Sequence for Region 1.
Select Sweep Region for Region 0. 0 = No Sweep, 1 = Sweep.
Select Multiplier Region for Region 0. 0 = No Multiplier, 1 = Multiplier.
Selected Vertical Sequence for Region 1.
Select Sweep Region for Region 1. 0 = No Sweep, 1 = Sweep.
Select Multiplier Region for Region 1. 0 = No Multiplier, 1 = Multiplier.
Selected Vertical Sequence for Region 2.
Vertical Select Sweep Region for Region 2. 0 = No Sweep, 1 = Sweep.
Select Multiplier Region for Region 2. 0 = No Multiplier, 1 = Multiplier.
Selected Vertical Sequence for Region 3.
Select Sweep Region for Region 3. 0 = No Sweep, 1 = Sweep.
Select Multiplier Region for Region 3. 0 = No Multiplier, 1 = Multiplier.
Selected Vertical Sequence for Region 4.
Select Sweep Region for Region 4. 0 = No Sweep, 1 = Sweep.
Select Multiplier Region for Region 4. 0 = No Multiplier, 1 = Multiplier.
Selected Vertical Sequence for Region 5.
Select Sweep Region for Region 5. 0 = No Sweep, 1 = Sweep.
Select Multiplier Region for Region 5. 0 = No Multiplier, 1 = Multiplier.
Selected Vertical Sequence for Region 6.
Select Sweep Region for Region 6. 0 = No Sweep, 1 = Sweep.
Select Multiplier Region for Region 6. 0 = No Multiplier, 1 = Multiplier. Unused.
Vertical Sequence Change Position No. 1 for Field 2.
Vertical Sequence Change Position No. 2 for Field 2.
Vertical Sequence Change Position No. 3 for Field 2.
Vertical Sequence Change Position No. 4 for Field 2.
VD Field Length (Number of Lines) for Field 2.
HD Line Length (Number of Pixels) for Last Line in Field 2.
Selected Second Vertical Pattern Group for VSG Active Line.
Masking of VSG Outputs during VSG Active Line.
Selection of VSG Patterns for Each VSG Output.
MSB for 13-Bit Last Line Length
VSG Active Line 1.
VSG Active Line 2.
(If No Second Line Is Needed, Set to Same as Line 1 or Maximum).
Vertical Sequence Change Position No. 5 for Field 2.
Vertical Sequence Change Position No. 6 for Field 2.
Rev. A | Page 83 of 96
AD9925
Table 71. Field 3 Register Map
Address
E8
E9
EA
EB
EC
ED
EE
EF
Data Bit Content
[3:0]
[4]
[5]
[9:6]
[10]
[11]
[15:12]
[16]
[17]
[21:18]
[22]
[23]
[3:0]
[4]
[5]
[9:6]
[10]
[11]
[15:12]
[16]
[17]
[23:18]
[11:0]
[23:12]
[11:0]
[23:12]
[11:0]
[23:12]
[3:0]
[9:4]
[21:10]
[22]
[11:0]
[23:12]
Default Value
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
Register Name
VSEQSEL_3
SWEEP0_3
MULTI0_3
VSEQSEL1_3
SWEEP1_3
MULTI1_3
VSEQSEL2_3
SWEEP2_3
MULTI2_3
VSEQSEL3_3
SWEEP3_3
MULTI3_3
VSEQSEL4_3
SWEEP4_3
MULTI4_3
VSEQSEL5_3
SWEEP5_3
MULTI5_3
VSEQSEL6_3
SWEEP6_3
MULTI6_3
UNUSED
SCP1_3
SCP2_3
SCP3_3
SCP4_3
VDLEN_3
HDLAST_3
VPATSECOND_3
SGMASK_3
SGPATSEL_3
HDLAST13_3
SGLINE1_3
SGLINE2_3
[11:0]
[23:12]
X
X
SCP5_3
SCP6_3
Register Description
Selected Vertical Sequence for Region 0.
Select Sweep Region for Region 0. 0 = No Sweep, 1 = Sweep.
Select Multiplier Region for Region 0. 0 = No Multiplier, 1 = Multiplier.
Selected Vertical Sequence for Region 1.
Select Sweep Region for Region 1. 0 = No Sweep, 1 = Sweep.
Select Multiplier Region for Region 1. 0 = No Multiplier, 1 = Multiplier.
Selected Vertical Sequence for Region 2.
Select Sweep Region for Region 2. 0 = No Sweep, 1 = Sweep.
Select Multiplier Region for Region 2. 0 = No Multiplier, 1 = Multiplier.
Selected Vertical Sequence for Region 3.
Select Sweep Region for Region 3. 0 = No Sweep, 1 = Sweep.
Select Multiplier Region for Region 3. 0 = No Multiplier, 1 = Multiplier.
Selected Vertical Sequence for Region 4.
Select Sweep Region for Region 4. 0 = No Sweep, 1 = Sweep.
Select Multiplier Region for Region 4. 0 = No Multiplier, 1 = Multiplier.
Selected Vertical Sequence for Region 5.
Select Sweep Region for Region 5. 0 = No Sweep, 1 = Sweep.
Select Multiplier Region for Region 5. 0 = No Multiplier, 1 = Multiplier.
Selected Vertical Sequence for Region 6.
Select Sweep Region for Region 6. 0 = No Sweep, 1 = Sweep.
Select Multiplier Region for Region 6. 0 = No Multiplier, 1 = Multiplier.
Unused .
Vertical Sequence Change Position No. 1 for Field 3.
Vertical Sequence Change Position No. 2 for Field 3.
Vertical Sequence Change Position No. 3 for Field 3.
Vertical Sequence Change Position No. 4 for Field 3.
VD Field Length (Number of Lines) for Field 3.
HD Line Length (Number of Pixels) for Last Line in Field 3.
Selected Second Vertical Pattern Group for VSG Active Line.
Masking of VSG Outputs during VSG Active Line.
Selection of VSG Patterns for Each VSG Output.
MSB for 13-Bit Last Line Length
VSG Active Line 1.
VSG Active Line 2.
(If No Second Line Is Needed, Set to Same as Line 1 or Maximum).
Vertical Sequence Change Position No. 5 for Field 3.
Vertical Sequence Change Position No. 6 for Field 3.
Rev. A | Page 84 of 96
AD9925
Table 72. Field 4 Register Map
Address
F0
F1
F2
F3
F4
F5
F6
F7
Data Bit Content
[3:0]
[4]
[5]
[9:6]
[10]
[11]
[15:12]
[16]
[17]
[21:18]
[22]
[23]
[3:0]
[4]
[5]
[9:6]
[10]
[11]
[15:12]
[16]
[17]
[23:18]
[11:0]
[23:12]
[11:0]
[23:12]
[11:0]
[23:12]
[3:0]
[9:4]
[21:10]
[22]
[11:0]
[23:12]
Default Value
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
Register Name
VSEQSEL0_4
SWEEP0_4
MULTI0_4
VSEQSEL1_4
SWEEP1_4
MULTI1_4
VSEQSEL2_4
SWEEP2_4
MULTI2_4
VSEQSEL3_4
SWEEP3_4
MULTI3_4
VSEQSEL4_4
SWEEP4_4
MULTI4_4
VSEQSEL5_4
SWEEP5_4
MULTI5_4
VSEQSEL6_4
SWEEP6_4
MULTI6_4
UNUSED
SCP1_4
SCP2_4
SCP3_4
SCP4_4
VDLEN_4
HDLAST_4
VPATSECOND_4
SGMASK_4
SGPATSEL_4
HDLAST13_4
SGLINE1_4
SGLINE2_4
[11:0]
[23:12]
X
X
SCP5_4
SCP6_4
Register Description
Selected Vertical Sequence for Region 0.
Select Sweep Region for Region 0. 0 = No Sweep, 1 = Sweep.
Select Multiplier Region for Region 0. 0 = No Multiplier, 1 = Multiplier.
Selected Vertical Sequence for Region 1.
Select Sweep Region for Region 1. 0 = No Sweep, 1 = Sweep.
Select Multiplier Region for Region 1. 0 = No Multiplier, 1 = Multiplier.
Selected Vertical Sequence for Region 2.
Select Sweep Region for Region 2. 0 = No Sweep, 1 = Sweep.
Select Multiplier Region for Region 2. 0 = No Multiplier, 1 = Multiplier.
Selected Vertical Sequence for Region 3.
Select Sweep Region for Region 3. 0 = No Sweep, 1 = Sweep.
Select Multiplier Region for Region 3. 0 = No Multiplier, 1 = Multiplier.
Selected Vertical Sequence for Region 4.
Select Sweep Region for Region 4. 0 = No Sweep, 1 = Sweep.
Select Multiplier Region for Region 4. 0 = No Multiplier, 1 = Multiplier.
Selected Vertical Sequence for Region 5.
Select Sweep Region for Region 5. 0 = No Sweep, 1 = Sweep.
Select Multiplier Region for Region 5. 0 = No Multiplier, 1 = Multiplier.
Selected Vertical Sequence for Region 6.
Select Sweep Region for Region 6. 0 = No Sweep, 1 = Sweep.
Select Multiplier Region for Region 6. 0 = No Multiplier, 1 = Multiplier.
Unused.
Vertical Sequence Change Position No. 1 for Field 4.
Vertical Sequence Change Position No. 2 for Field 4.
Vertical Sequence Change Position No. 3 for Field 4.
Vertical Sequence Change Position No. 4 for Field 4.
VD Field Length (Number of Lines) for Field 4.
HD Line Length (Number of Pixels) for Last Line in Field 4.
Selected Second Vertical Pattern Group for VSG Active Line.
Masking of VSG Outputs during VSG Active Line.
Selection of VSG Patterns for Each VSG Output.
MSB for 13-Bit Last Line Length
VSG Active Line 1.
VSG Active Line 2.
(If No Second Line Is Needed, Set to Same as Line 1 or Maximum).
Vertical Sequence Change Position No. 5 for Field 4.
Vertical Sequence Change Position No. 6 for Field 4.
Rev. A | Page 85 of 96
AD9925
Table 73. Field 5 Register Map
Address
F8
F9
FA
FB
FC
FD
FE
FF
Data Bit Content
[3:0]
[4]
[5]
[9:6]
[10]
[11]
[15:12]
[16]
[17]
[21:18]
[22]
[23]
[3:0]
[4]
[5]
[9:6]
[10]
[11]
[15:12]
[16]
[17]
[23:18]
[11:0]
[23:12]
[11:0]
[23:12]
[11:0]
[23:12]
[3:0]
[9:4]
[21:10]
[22]
[11:0]
[23:12]
Default Value
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
Register Name
VSEQSEL0_5
SWEEP0_5
MULTI0_5
VSEQSEL1_5
SWEEP1_5
MULTI1_5
VSEQSEL2_5
SWEEP2_5
MULTI2_5
VSEQSEL3_5
SWEEP3_5
MULTI3_5
VSEQSEL4_5
SWEEP4_5
MULTI4_5
VSEQSEL5_5
SWEEP5_5
MULTI5_5
VSEQSEL6_5
SWEEP6_5
MULTI6_5
UNUSED
SCP1_5
SCP2_5
SCP3_5
SCP4_5
VDLEN_5
HDLAST_5
VPATSECOND_5
SGMASK_5
SGPATSEL_5
HDLAST13_5
SGLINE1_5
SGLINE2_5
[11:0]
[23:12]
X
X
SCP5_5
SCP6_5
Register Description
Selected Vertical Sequence for Region 0.
Select Sweep Region for Region 0. 0 = No Sweep, 1 = Sweep.
Select Multiplier Region for Region 0. 0 = No Multiplier, 1 = Multiplier.
Selected Vertical Sequence for Region 1.
Select Sweep Region for Region 1. 0 = No Sweep, 1 = Sweep.
Select Multiplier Region for Region 1. 0 = No Multiplier, 1 = Multiplier.
Selected Vertical Sequence for Region 2.
Select Sweep Region for Region 2. 0 = No Sweep, 1 = Sweep.
Select Multiplier Region for Region 2. 0 = No Multiplier, 1 = Multiplier.
Selected Vertical Sequence for Region 3.
Select Sweep Region for Region 3. 0 = No Sweep, 1 = Sweep.
Select Multiplier Region for Region 3. 0 = No Multiplier, 1 = Multiplier.
Selected Vertical Sequence for Region 4.
Select Sweep Region for Region 4. 0 = No Sweep, 1 = Sweep.
Select Multiplier Region for Region 4. 0 = No Multiplier, 1 = Multiplier.
Selected Vertical Sequence for Region 5.
Select Sweep Region for Region 5. 0 = No Sweep, 1 = Sweep.
Select Multiplier Region for Region 5. 0 = No Multiplier, 1 = Multiplier.
Selected Vertical Sequence for Region 6.
Select Sweep Region for Region 6. 0 = No Sweep, 1 = Sweep.
Select Multiplier Region for Region 6. 0 = No Multiplier, 1 = Multiplier.
Unused.
Vertical Sequence Change Position No.1 for Field 5.
Vertical Sequence Change Position No.2 for Field 5.
Vertical Sequence Change Position No.3 for Field 5.
Vertical Sequence Change Position No.4 for Field 5.
VD Field Length (Number of Lines) for Field 5.
HD Line Length (Number of Pixels) for Last Line in Field 5.
Selected Second Vertical Pattern Group for VSG Active Line.
Masking of VSG Outputs during VSG Active Line.
Selection of VSG Patterns for Each VSG Output.
MSB for 13-Bit Last Line Length
VSG Active Line 1.
VSG Active Line 2.
(If No Second Line Is Needed, Set to Same as Line 1 or Maximum).
Vertical Sequence Change Position No.5 for Field 5.
Vertical Sequence Change Position No.6 for Field 5.
Rev. A | Page 86 of 96
AD9925
COMPLETE LISTING FOR REGISTER BANK 3
All vertical pattern group and vertical sequence registers are SCP updated. Default register values are undefined.
Table 74. XV7 and XV8 Pattern Group 0 (VPAT0) Registers
Address
00
01
02
03
04
05
06
07
Data Bit Content
[0]
[1]
[11:2]
[23:12]
[11:0]
[23:12]
[11:0]
[23:12]
[11:0]
[23:12]
[11:0]
[23:12]
[23:0]
[23:0]
[23:0]
Default Value
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
Register Name
XV7POL_0
XV8POL_0
UNUSED
XV78LEN_0
XV7TOG1_0
XV7TOG2_0
XV7TOG3_0
XV8TOG1_0
XV8TOG2_0
XV8TOG3_0
XV7TOG4_0
XV8TOG4_0
UNUSED
UNUSED
UNUSED
Register Description
VPAT0 XV7 Start Polarity
VPAT0 XV8 Start Polarity
Unused
Total Length of XV7 and XV8 Pattern for VPAT0
XV7 Toggle Position 1
XV7 Toggle Position 2
XV7 Toggle Position 3
XV8 Toggle Position 1
XV8 Toggle Position 2
XV8 Toggle Position 3
XV7 Toggle Position 4
XV8 Toggle Position 4
Unused
Unused
Unused
Table 75. XV7 and XV8 Pattern Group 1 (VPAT1) Registers
Address
08
09
0A
0B
0C
0D
0E
0F
Data Bit Content
[0]
[1]
[11:2]
[23:12]
[11:0]
[23:12]
[11:0]
[23:12]
[11:0]
[23:12]
[11:0]
[23:12]
[23:0]
[23:0]
[23:0]
Default Value
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
Register Name
XV7POL_1
XV8POL_1
UNUSED
XV78LEN_1
XV7TOG1_1
XV7TOG2_1
XV7TOG3_1
XV8TOG1_1
XV8TOG2_1
XV8TOG3_1
XV7TOG4_1
XV8TOG4_1
UNUSED
UNUSED
UNUSED
Rev. A | Page 87 of 96
Register Description
VPAT1 XV7 Start Polarity
VPAT1 XV8 Start Polarity
Unused
Total Length of XV7 and XV8 Pattern for VPAT2
XV7 Toggle Position 1
XV7 Toggle Position 2
XV7 Toggle Position 3
XV8 Toggle Position 1
XV8 Toggle Position 2
XV8 Toggle Position 3
XV7 Toggle Position 4
XV8 Toggle Position 4
Unused
Unused
Unused
AD9925
Table 76. XV7 and XV8 Pattern Group 2 (VPAT2) Registers
Address
10
11
12
13
14
15
16
17
Data Bit Content
[0]
[1]
[11:2]
[23:12]
[11:0]
[23:12]
[11:0]
[23:12]
[11:0]
[23:12]
[11:0]
[23:12]
[23:0]
[23:0]
[23:0]
Default Value
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
Register Name
XV7POL_2
XV8POL_2
UNUSED
XV78LEN_2
XV7TOG1_2
XV7TOG2_2
XV7TOG3_2
XV8TOG1_2
XV8TOG2_2
XV8TOG3_2
XV7TOG4_2
XV8TOG4_2
UNUSED
UNUSED
UNUSED
Register Description
VPAT2 XV7 Start Polarity
VPAT2 XV8 Start Polarity
Unused
Total Length of XV7 and XV8 Pattern for VPAT2
XV7 Toggle Position 1
XV7 Toggle Position 2
XV7 Toggle Position 3
XV8 Toggle Position 1
XV8 Toggle Position 2
XV8 Toggle Position 3
XV7 Toggle Position 4
XV8 Toggle Position 4
Unused
Unused
Unused
Table 77. XV7 and XV8 Pattern Group 3 (VPAT3) Registers
Address
18
19
1A
1B
1C
1D
1E
1F
Data Bit Content
[0]
[1]
[11:2]
[23:12]
[11:0]
[23:12]
[11:0]
[23:12]
[11:0]
[23:12]
[11:0]
[23:12]
[23:0]
[23:0]
[23:0]
Default Value
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
Register Name
XV7POL_3
XV8POL_3
UNUSED
XV78LEN_3
XV7TOG1_3
XV7TOG2_3
XV7TOG3_3
XV8TOG1_3
XV8TOG2_3
XV8TOG3_3
XV7TOG4_3
XV8TOG4_3
UNUSED
UNUSED
UNUSED
Register Description
VPAT3 XV7 Start Polarity
VPAT3 XV8 Start Polarity
Unused
Total Length of XV7 and XV8 Pattern for VPAT3
XV7 Toggle Position 1
XV7 Toggle Position 2
XV7 Toggle Position 3
XV8 Toggle Position 1
XV8 Toggle Position 2
XV8 Toggle Position 3
XV7 Toggle Position 4
XV8 Toggle Position 4
Unused
Unused
Unused
Table 78. XV7 and XV8 Pattern Group 4 (VPAT4) Registers
Address
20
21
22
23
24
25
26
27
Data Bit Content
[0]
[1]
[11:2]
[23:12]
[11:0]
[23:12]
[11:0]
[23:12]
[11:0]
[23:12]
[11:0]
[23:12]
[23:0]
[23:0]
[23:0]
Default Value
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
Register Name
XV7POL_4
XV8POL_4
UNUSED
XV78LEN_4
XV7TOG1_4
XV7TOG2_4
XV7TOG3_4
XV8TOG1_4
XV8TOG2_4
XV8TOG3_4
XV7TOG4_4
XV8TOG4_4
UNUSED
UNUSED
UNUSED
Rev. A | Page 88 of 96
Register Description
VPAT4 XV7 Start Polarity
VPAT4 XV8 Start Polarity
Unused
Total Length of XV7 and XV8 Pattern for VPAT4
XV7 Toggle Position 1
XV7 Toggle Position 2
XV7 Toggle Position 3
XV8 Toggle Position 1
XV8 Toggle Position 2
XV8 Toggle Position 3
XV7 Toggle Position 4
XV8 Toggle Position 4
Unused
Unused
Unused
AD9925
Table 79. XV7 and XV8 Pattern Group 5 (VPAT5) Registers
Address
28
29
2A
2B
2C
2D
2E
2F
Data Bit Content
[0]
[1]
[11:2]
[23:12]
[11:0]
[23:12]
[11:0]
[23:12]
[11:0]
[23:12]
[11:0]
[23:12]
[23:0]
[23:0]
[23:0]
Default Value
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
Register Name
XV7POL_5
XV8POL_5
UNUSED
XV78LEN_5
XV7TOG1_5
XV7TOG2_5
XV7TOG3_5
XV8TOG1_5
XV8TOG2_5
XV8TOG3_5
XV7TOG4_5
XV8TOG4_5
UNUSED
UNUSED
UNUSED
Register Description
VPAT5 XV7 Start Polarity
VPAT5 XV8 Start Polarity
Unused
Total Length of XV7 and XV8 Pattern for VPAT5
XV7 Toggle Position 1
XV7 Toggle Position 2
XV7 Toggle Position 3
XV8 Toggle Position 1
XV8 Toggle Position 2
XV8 Toggle Position 3
XV7 Toggle Position 4
XV8 Toggle Position 4
Unused
Unused
Unused
Table 80. XV7 and XV8 Pattern Group 6 (VPAT6) Registers
Address
30
31
32
33
34
35
36
37
Data Bit Content
[0]
[1]
[11:2]
[23:12]
[11:0]
[23:12]
[11:0]
[23:12]
[11:0]
[23:12]
[11:0]
[23:12]
[23:0]
[23:0]
[23:0]
Default Value
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
Register Name
XV7POL_6
XV8POL_6
UNUSED
XV78LEN_6
XV7TOG1_6
XV7TOG2_6
XV7TOG3_6
XV8TOG1_6
XV8TOG2_6
XV8TOG3_6
XV7TOG4_6
XV8TOG4_6
UNUSED
UNUSED
UNUSED
Register Description
VPAT6 XV7 Start Polarity
VPAT6 XV8 Start Polarity
Unused
Total Length of XV7 and XV8 Pattern for VPAT6
XV7 Toggle Position 1
XV7 Toggle Position 2
XV7 Toggle Position 3
XV8 Toggle Position 1
XV8 Toggle Position 2
XV8 Toggle Position 3
XV7 Toggle Position 4
XV8 Toggle Position 4
Unused
Unused
Unused
Table 81. XV7 and XV8 Pattern Group 7 (VPAT7) Registers
Address
38
39
3A
3B
3C
3D
3E
3F
Data Bit Content
[0]
[1]
[11:2]
[23:12]
[11:0]
[23:12]
[11:0]
[23:12]
[11:0]
[23:12]
[11:0]
[23:12]
[23:0]
[23:0]
[23:0]
Default Value
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
Register Name
XV7POL_7
XV8POL_7
UNUSED
XV78LEN_7
XV7TOG1_7
XV7TOG2_7
XV7TOG3_7
XV8TOG1_7
XV8TOG2_7
XV8TOG3_7
XV7TOG4_7
XV8TOG4_7
UNUSED
UNUSED
UNUSED
Rev. A | Page 89 of 96
Register Description
VPAT7 XV7 Start Polarity
VPAT7 XV8 Start Polarity
Unused
Total Length of XV7 and XV8 Pattern for VPAT7
XV7 Toggle Position 1
XV7 Toggle Position 2
XV7 Toggle Position 3
XV8 Toggle Position 1
XV8 Toggle Position 2
XV8 Toggle Position 3
XV7 Toggle Position 4
XV8 Toggle Position 4
Unused
Unused
Unused
AD9925
Table 82. XV7 and XV8 Pattern Group 8 (VPAT8) Registers
Address
40
41
42
43
44
45
46
47
Data Bit Content
[0]
[1]
[11:2]
[23:12]
[11:0]
[23:12]
[11:0]
[23:12]
[11:0]
[23:12]
[11:0]
[23:12]
[23:0]
[23:0]
[23:0]
Default Value
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
Register Name
XV7POL_8
XV8POL_8
UNUSED
XV78LEN_8
XV7TOG1_8
XV7TOG2_8
XV7TOG3_8
XV8TOG1_8
XV8TOG2_8
XV8TOG3_8
XV7TOG4_8
XV8TOG4_8
UNUSED
UNUSED
UNUSED
Register Description
VPAT8 XV7 Start Polarity
VPAT8 XV8 Start Polarity
Unused
Total Length of XV7 and XV8 Pattern for VPAT8
XV7 Toggle Position 1
XV7 Toggle Position 2
XV7 Toggle Position 3
XV8 Toggle Position 1
XV8 Toggle Position 2
XV8 Toggle Position 3
XV7 Toggle Position 4
XV8 Toggle Position 4
Unused
Unused
Unused
Table 83. XV7 and XV8 Pattern Group 9 (VPAT9) Registers
Address
48
49
4A
4B
4C
4D
4E
4F
Data Bit Content
[0]
[1]
[11:2]
[23:12]
[11:0]
[23:12]
[11:0]
[23:12]
[11:0]
[23:12]
[11:0]
[23:12]
[23:0]
[23:0]
[23:0]
Default Value
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
Register Name
XV7POL_9
XV8POL_9
UNUSED
XV78LEN_9
XV7TOG1_9
XV7TOG2_9
XV7TOG3_9
XV8TOG1_9
XV8TOG2_9
XV8TOG3_9
XV7TOG4_9
XV8TOG4_9
UNUSED
UNUSED
UNUSED
Register Description
VPAT9 XV7 Start Polarity
VPAT9 XV8 Start Polarity
Unused
Total Length of XV7 and XV8 Pattern for VPAT9
XV7 Toggle Position 1
XV7 Toggle Position 2
XV7 Toggle Position 3
XV8 Toggle Position 1
XV8 Toggle Position 2
XV8 Toggle Position 3
XV7 Toggle Position 4
XV8 Toggle Position 4
Unused
Unused
Unused
Table 84. XV7 and XV8 Vertical Sequence 0 Registers
Address
50
Data Bit Content
[0]
Default Value
X
Register Name
HOLD_0
51
52
[11:1]
[23:12]
[11:0]
[23:12]
[0]
X
X
X
X
X
UNUSED
XV78START_0
XV78REPO_0
XV78REPE_0
XV78HOLDEN_0
53
[23:1]
[23:0]
X
X
UNUSED
UNUSED
Rev. A | Page 90 of 96
Register Description
0: Vertical Masking Operation, 1: Hold Area instead of
Vertical Masking
Unused
Start Position for XV7 and XV8
Number of Selected XV7, XV8 Repetitions for Odd Lines
Number of Selected XV7, XV8 Repetitions for Even Lines
0: No Hold Area for XV7 and XV8,1: Enable Hold Area for
XV7 and XV8
Unused
Unused
AD9925
Table 85. XV7 and XV8 Vertical Sequence 1 Registers
Address
54
55
56
57
Data Bit Content
[0]
[11:1]
[23:12]
[11:0]
[23:12]
[0]
[23:1]
[23:0]
Default Value
X
X
X
X
X
X
X
X
Register Name
HOLD_1
UNUSED
XV78START_1
XV78REPO_1
XV78REPE_1
XV78HOLDEN_1
UNUSED
UNUSED
Register Description
0: Vertical Masking Operation, 1: Hold Area instead of Vertical Masking
Unused
Start Position for XV7 and XV8
Number of Selected XV7, XV8 Repetitions for Odd Lines
Number of Selected XV7, XV8 Repetitions for Even Lines
0: No Hold Area for XV7 and XV8, 1: Enable Hold Area for XV7 and XV8
Unused
Unused
Table 86. XV7 and XV8 Vertical Sequence 2 Registers
Address
58
59
5A
5B
Data Bit Content
[0]
[11:1]
[23:12]
[11:0]
[23:12]
[0]
[23:1]
[23:0]
Default Value
X
X
X
X
X
X
X
X
Register Name
HOLD_2
UNUSED
XV78START_2
XV78REPO_2
XV78REPE_2
XV78HOLDEN_2
UNUSED
UNUSED
Register Description
0: Vertical Masking Operation, 1: Hold Area instead of Vertical Masking
Unused
Start Position for XV7 and XV8
Number of Selected XV7, XV8 Repetitions for Odd Lines
Number of Selected XV7, XV8 Repetitions for Even Lines
0: No Hold Area for XV7 and XV8, 1: Enable Hold Area for XV7 and XV8
Unused
Unused
Table 87. XV7 and XV8 Vertical Sequence 3 Registers
Address
5C
5D
5E
5F
Data Bit Content
[0]
[11:1]
[23:12]
[11:0]
[23:12]
[0]
[23:1]
[23:0]
Default Value
X
X
X
X
X
X
X
X
Register Name
HOLD_3
UNUSED
XV78START_3
XV78REPO_3
XV78REPE_3
XV78HOLDEN_3
UNUSED
UNUSED
Register Description
0: Vertical Masking Operation, 1: Hold Area instead of Vertical Masking
Unused
Start Position for XV7 and XV8
Number of Selected XV7, XV8 Repetitions for Odd Lines
Number of Selected XV7, XV8 Repetitions for Even Lines
0: No Hold Area for XV7 and XV8, 1: Enable Hold Area for XV7 and XV8
Unused
Unused
Table 88. XV7 and XV8 Vertical Sequence 4 Registers
Address
60
61
62
63
Data Bit Content
[0]
[11:1]
[23:12]
[11:0]
[23:12]
[0]
[23:1]
[23:0]
Default Value
X
X
X
X
X
X
X
X
Register Name
HOLD_4
UNUSED
XV78START_4
XV78REPO_4
XV78REPE_4
XV78HOLDEN_4
UNUSED
UNUSED
Register Description
0: Vertical Masking Operation, 1: Hold Area instead of Vertical Masking
Unused
Start Position for XV7 and XV8
Number of Selected XV7, XV8 Repetitions for Odd Lines
Number of Selected XV7, XV8 Repetitions for Even Lines
0: No Hold Area for XV7 and XV8, 1: Enable Hold Area for XV7 and XV8
Unused
Unused
Rev. A | Page 91 of 96
AD9925
Table 89. XV7 and XV8 Vertical Sequence 5 Registers
Address
64
65
66
67
Data Bit Content
[0]
[11:1]
[23:12]
[11:0]
[23:12]
[0]
[23:1]
[23:0]
Default Value
X
X
X
X
X
X
X
X
Register Name
HOLD_5
UNUSED
XV78START_5
XV78REPO_5
XV78REPE_5
XV78HOLDEN_5
UNUSED
UNUSED
Register Description
0: Vertical Masking Operation, 1: Hold Area instead of Vertical Masking
Unused
Start Position for XV7 and XV8
Number of Selected XV7, XV8 Repetitions for Odd Lines
Number of Selected XV7, XV8 Repetitions for Even Lines
0: No Hold Area for XV7 and XV8, 1: Enable Hold Area for XV7 and XV8
Unused
Unused
Table 90. XV7 and XV8 Vertical Sequence 6 Registers
Address
68
69
6A
6B
Data Bit Content
[0]
[11:1]
[23:12]
[11:0]
[23:12]
[0]
[23:1]
[23:0]
Default Value
X
X
X
X
X
X
X
X
Register Name
HOLD_6
UNUSED
XV78START_6
XV78REPO_6
XV78REPE_6
XV78HOLDEN_6
UNUSED
UNUSED
Register Description
0: Vertical Masking Operation, 1: Hold Area instead of Vertical Masking
Unused
Start Position for XV7 and XV8
Number of Selected XV7, XV8 Repetitions for Odd Lines
Number of Selected XV7, XV8 Repetitions for Even Lines
0: No Hold Area for XV7 and XV8, 1: Enable Hold Area for XV7 and XV8
Unused
Unused
Table 91. XV7 and XV8 Vertical Sequence 7 Registers
Address
6C
6D
6E
6F
Data Bit Content
[0]
[11:1]
[23:12]
[11:0]
[23:12]
[0]
[23:1]
[23:0]
Default Value
X
X
X
X
X
X
X
X
Register Name
HOLD_7
UNUSED
XV78START_7
XV78REPO_7
XV78REPE_7
XV78HOLDEN_7
UNUSED
UNUSED
Register Description
0: Vertical Masking Operation, 1: Hold Area instead of Vertical Masking
Unused
Start Position for XV7 and XV8
Number of Selected XV7, XV8 Repetitions for Odd Lines
Number of Selected XV7, XV8 Repetitions for Even Lines
0: No Hold Area for XV7 and XV8, 1: Enable Hold Area for XV7 and XV8
Unused
Unused
Table 92. XV7 and XV8 Vertical Sequence 8 Registers
Address
70
71
72
73
Data Bit Content
[0]
[11:1]
[23:12]
[11:0]
[23:12]
[0]
[23:1]
[23:0]
Default Value
X
X
X
X
X
X
X
X
Register Name
HOLD_8
UNUSED
XV78START_8
XV78REPO_8
XV78REPE_8
XV78HOLDEN_8
UNUSED
UNUSED
Register Description
0: Vertical Masking Operation, 1: Hold Area instead of Vertical Masking
Unused
Start Position for XV7 and XV8
Number of Selected XV7, XV8 Repetitions for Odd Lines
Number of Selected XV7, XV8 Repetitions for Even Lines
0: No Hold Area for XV7 and XV8, 1: Enable Hold Area for XV7 and XV8
Unused
Unused
Rev. A | Page 92 of 96
AD9925
Table 93. XV7 and XV8 Vertical Sequence 9 Registers
Address
74
75
76
77
Data Bit Content
[0]
[11:1]
[23:12]
[11:0]
[23:12]
[0]
[23:1]
[23:0]
Default Value
X
X
X
X
X
X
X
X
Register Name
HOLD_9
UNUSED
XV78START_9
XV78REPO_9
XV78REPE_9
XV78HOLDEN_9
UNUSED
UNUSED
Register Description
0: Vertical Masking Operation, 1: Hold Area instead of Vertical Masking
Unused
Start Position for XV7 and XV8
Number of Selected XV7, XV8 Repetitions for Odd Lines
Number of Selected XV7, XV8 Repetitions for Even Lines
0: No Hold Area for XV7 and XV8, 1: Enable Hold Area for XV7 and XV8
Unused
Unused
Rev. A | Page 93 of 96
AD9925
OUTLINE DIMENSIONS
A1 CORNER
INDEX AREA
8.00
BSC SQ
11 10 9 8 7 6 5 4 3 2 1
A
BALL A1
INDICATOR
TOP VIEW
6.50
BSC SQ
BOTTOM
VIEW
B
C
D
E
F
G
H
J
K
L
0.75 REF
0.65 BSC
DETAIL A
1.40 MAX
DETAILA
0.40
0.25
0.45
0.40
0.35
1.00
0.85
0.10 MAX
COPLANARITY
SEATING
PLANE
BALL DIAMETER
Figure 78. 96-Lead Chip Scale Package Ball Grid Array [CSP_BGA]
(BC-96)
Dimensions shown in millimeters
ORDERING GUIDE
Models
AD9925BBCZ1
AD9925BBCZRL1
TP
1
TP
PT
PT
Temperature Range
–25°C to +85°C
–25°C to +85°C
Package Description
CSP_BGA
CSP_BGA Tape and Reel
Z = Pb-free part.
Rev. A | Page 94 of 96
Option
BC-96
BC-96
AD9925
NOTES
Rev. A | Page 95 of 96
AD9925
NOTES
© 2004 Analog Devices, Inc. All rights reserved. Trademarks and
registered trademarks are the property of their respective owners.
D04637–0–10/04(A)
Rev. A | Page 96 of 96
Similar pages