Vishay LCD-240H128B 240 x 128 graphic lcd Datasheet

LCD-240H128B
www.vishay.com
Vishay
240 x 128 Graphic LCD
FEATURES
• Type: graphic
• Display format: 240 x 128 dots
• Built-in controller: RA6963
• Duty cycle: 1/128
• Built-in N.V.
• Temperature compensation optional
• Material categorization: for definitions of compliance
please see www.vishay.com/doc?99912
MECHANICAL DATA
ITEM
ABSOLUTE MAXIMUM RATINGS
STANDARD VALUE
UNIT
ITEM
SYMBOL
114.0 x 64.0
Power supply
0.40 x 0.40
Input voltage
Module dimension
144.0 x 104.0
Viewing area
Dot size
Dot pitch
0.45 x 0.45
Mounting hole
138.0 x 99.0
Character size
n/a
mm
STANDARD VALUE
MIN.
TYP.
MAX.
VDD to VSS
4.75
5.0
5.25
VI
-0.3
-
VDD
UNIT
V
Note
• VSS = 0 V, VDD = 5.0 V
ELECTRICAL CHARACTERISTICS
ITEM
SYMBOL
Input voltage
Supply current
STANDARD VALUE
CONDITION
MIN.
TYP.
MAX.
VDD
L level
0.7 VDD
-
VDD
VIO
H level
-
-
0.3 VDD
IDD
VDD = +5 V
0
55
60
-20 °C
-
-
-
Recommended
LC driving voltage for
normal temperature
version module
VDD to V0
70 °C
LED forward voltage
VF
25 °C
LED forward current
IF
25 °C
CCFL forward voltage
VF
CCFL forward current
IF
EL power supply current
IEL
UNIT
V
mA
0 °C
20.3
21.4
22.5
25 °C
18.0
19.1
20.2
50 °C
17.8
18.9
20.0
-
-
-
-
4.2
-
V
-
900
1800
mA
25 °C
-
250
590
VRMS
25 °C
-
-
5.5
mARMS
VEL = 110 VAC, 400 Hz
-
-
5.0
mA
V
OPTIONS
PROCESS COLOR
BACKLIGHT
TN
STN
GRAY
STN
YELLOW
STN
BLUE
FSTN
B&W
STN
COLOR
NONE
LED
EL
CCFL
-
x
x
x
x
-
x
x
x
x
For detailed information, please see the “Product Numbering System” document.
Document Number: 37377
1
For technical questions, contact: [email protected]
THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT
ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000
Revision: 22-Jun-17
LCD-240H128B
www.vishay.com
Vishay
INTERFACE PIN FUNCTION
PIN NO.
SYMBOL
FUNCTION
1
VSS
Power supply (ground)
2
VDD
Power supply (+5 V)
3
V0
Power supply for LCD driving
4
C/D
Command / data read / write
5
RD
Data read
6
WR
Data write
7
DB0
Data bus line
8
DB1
Data bus line
9
DB2
Data bus line
10
DB3
Data bus line
11
DB4
Data bus line
12
DB5
Data bus line
13
DB6
Data bus line
14
DB7
Data bus line
15
CE
Chip enable
16
RESET
Reset signal
17
VEE
Negative voltage output
18
MD2
Control signal
19
FS1
Font selection
20
NC
No connection
DIMENSIONS in millimeters
Document Number: 37377
2
For technical questions, contact: [email protected]
THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT
ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000
Revision: 22-Jun-17
Legal Disclaimer Notice
www.vishay.com
Vishay
Disclaimer

ALL PRODUCT, PRODUCT SPECIFICATIONS AND DATA ARE SUBJECT TO CHANGE WITHOUT NOTICE TO IMPROVE
RELIABILITY, FUNCTION OR DESIGN OR OTHERWISE.
Vishay Intertechnology, Inc., its affiliates, agents, and employees, and all persons acting on its or their behalf (collectively,
“Vishay”), disclaim any and all liability for any errors, inaccuracies or incompleteness contained in any datasheet or in any other
disclosure relating to any product.
Vishay makes no warranty, representation or guarantee regarding the suitability of the products for any particular purpose or
the continuing production of any product. To the maximum extent permitted by applicable law, Vishay disclaims (i) any and all
liability arising out of the application or use of any product, (ii) any and all liability, including without limitation special,
consequential or incidental damages, and (iii) any and all implied warranties, including warranties of fitness for particular
purpose, non-infringement and merchantability.
Statements regarding the suitability of products for certain types of applications are based on Vishay’s knowledge of
typical requirements that are often placed on Vishay products in generic applications. Such statements are not binding
statements about the suitability of products for a particular application. It is the customer’s responsibility to validate that a
particular product with the properties described in the product specification is suitable for use in a particular application.
Parameters provided in datasheets and / or specifications may vary in different applications and performance may vary over
time. All operating parameters, including typical parameters, must be validated for each customer application by the customer’s
technical experts. Product specifications do not expand or otherwise modify Vishay’s terms and conditions of purchase,
including but not limited to the warranty expressed therein.
Except as expressly indicated in writing, Vishay products are not designed for use in medical, life-saving, or life-sustaining
applications or for any other application in which the failure of the Vishay product could result in personal injury or death.
Customers using or selling Vishay products not expressly indicated for use in such applications do so at their own risk.
Please contact authorized Vishay personnel to obtain written terms and conditions regarding products designed for
such applications.
No license, express or implied, by estoppel or otherwise, to any intellectual property rights is granted by this document
or by any conduct of Vishay. Product names and markings noted herein may be trademarks of their respective owners.
© 2017 VISHAY INTERTECHNOLOGY, INC. ALL RIGHTS RESERVED
Revision: 08-Feb-17
1
Document Number: 91000