LCD-240H128B www.vishay.com Vishay 240 x 128 Graphic LCD FEATURES • Type: graphic • Display format: 240 x 128 dots • Built-in controller: RA6963 • Duty cycle: 1/128 • Built-in N.V. • Temperature compensation optional • Material categorization: for definitions of compliance please see www.vishay.com/doc?99912 MECHANICAL DATA ITEM ABSOLUTE MAXIMUM RATINGS STANDARD VALUE UNIT ITEM SYMBOL 114.0 x 64.0 Power supply 0.40 x 0.40 Input voltage Module dimension 144.0 x 104.0 Viewing area Dot size Dot pitch 0.45 x 0.45 Mounting hole 138.0 x 99.0 Character size n/a mm STANDARD VALUE MIN. TYP. MAX. VDD to VSS 4.75 5.0 5.25 VI -0.3 - VDD UNIT V Note • VSS = 0 V, VDD = 5.0 V ELECTRICAL CHARACTERISTICS ITEM SYMBOL Input voltage Supply current STANDARD VALUE CONDITION MIN. TYP. MAX. VDD L level 0.7 VDD - VDD VIO H level - - 0.3 VDD IDD VDD = +5 V 0 55 60 -20 °C - - - Recommended LC driving voltage for normal temperature version module VDD to V0 70 °C LED forward voltage VF 25 °C LED forward current IF 25 °C CCFL forward voltage VF CCFL forward current IF EL power supply current IEL UNIT V mA 0 °C 20.3 21.4 22.5 25 °C 18.0 19.1 20.2 50 °C 17.8 18.9 20.0 - - - - 4.2 - V - 900 1800 mA 25 °C - 250 590 VRMS 25 °C - - 5.5 mARMS VEL = 110 VAC, 400 Hz - - 5.0 mA V OPTIONS PROCESS COLOR BACKLIGHT TN STN GRAY STN YELLOW STN BLUE FSTN B&W STN COLOR NONE LED EL CCFL - x x x x - x x x x For detailed information, please see the “Product Numbering System” document. Document Number: 37377 1 For technical questions, contact: [email protected] THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000 Revision: 22-Jun-17 LCD-240H128B www.vishay.com Vishay INTERFACE PIN FUNCTION PIN NO. SYMBOL FUNCTION 1 VSS Power supply (ground) 2 VDD Power supply (+5 V) 3 V0 Power supply for LCD driving 4 C/D Command / data read / write 5 RD Data read 6 WR Data write 7 DB0 Data bus line 8 DB1 Data bus line 9 DB2 Data bus line 10 DB3 Data bus line 11 DB4 Data bus line 12 DB5 Data bus line 13 DB6 Data bus line 14 DB7 Data bus line 15 CE Chip enable 16 RESET Reset signal 17 VEE Negative voltage output 18 MD2 Control signal 19 FS1 Font selection 20 NC No connection DIMENSIONS in millimeters Document Number: 37377 2 For technical questions, contact: [email protected] THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000 Revision: 22-Jun-17 Legal Disclaimer Notice www.vishay.com Vishay Disclaimer ALL PRODUCT, PRODUCT SPECIFICATIONS AND DATA ARE SUBJECT TO CHANGE WITHOUT NOTICE TO IMPROVE RELIABILITY, FUNCTION OR DESIGN OR OTHERWISE. Vishay Intertechnology, Inc., its affiliates, agents, and employees, and all persons acting on its or their behalf (collectively, “Vishay”), disclaim any and all liability for any errors, inaccuracies or incompleteness contained in any datasheet or in any other disclosure relating to any product. Vishay makes no warranty, representation or guarantee regarding the suitability of the products for any particular purpose or the continuing production of any product. To the maximum extent permitted by applicable law, Vishay disclaims (i) any and all liability arising out of the application or use of any product, (ii) any and all liability, including without limitation special, consequential or incidental damages, and (iii) any and all implied warranties, including warranties of fitness for particular purpose, non-infringement and merchantability. Statements regarding the suitability of products for certain types of applications are based on Vishay’s knowledge of typical requirements that are often placed on Vishay products in generic applications. Such statements are not binding statements about the suitability of products for a particular application. It is the customer’s responsibility to validate that a particular product with the properties described in the product specification is suitable for use in a particular application. Parameters provided in datasheets and / or specifications may vary in different applications and performance may vary over time. All operating parameters, including typical parameters, must be validated for each customer application by the customer’s technical experts. Product specifications do not expand or otherwise modify Vishay’s terms and conditions of purchase, including but not limited to the warranty expressed therein. Except as expressly indicated in writing, Vishay products are not designed for use in medical, life-saving, or life-sustaining applications or for any other application in which the failure of the Vishay product could result in personal injury or death. Customers using or selling Vishay products not expressly indicated for use in such applications do so at their own risk. Please contact authorized Vishay personnel to obtain written terms and conditions regarding products designed for such applications. No license, express or implied, by estoppel or otherwise, to any intellectual property rights is granted by this document or by any conduct of Vishay. Product names and markings noted herein may be trademarks of their respective owners. © 2017 VISHAY INTERTECHNOLOGY, INC. ALL RIGHTS RESERVED Revision: 08-Feb-17 1 Document Number: 91000