AC/DC Current Transducer DHR-C420 The transducer for the electronic measurement of DC & distorted AC waveform currents, with galvanic isolation between the primary circuit (power) and the secondary circuit (measurement). True RMS 4-20 mA current output. IPN = 100 .. 400 A Electrical data Primary Nominal DC & AC Current IPN (A.t.RMS) 100 200 300 400 RL VC IC ISL ÎP Primary AC Current Max. Peak Value 1) IP (A) 600 600 1000 1000 Output current IOUT (mA DC) 4-20 4-20 4-20 4-20 Load resistance Supply voltage2) Current consumption Output current limitation Overload capability (Ampere Turns) Type Features DHR 100 C420 DHR 200 C420 DHR 300 C420 DHR 400 C420 < 300 + 20 .. 50 30 mA + IOUT < 25 30000 W V DC mA A.t Performance data X e L IOUT IOE TCIOE TCIOUT tr BW Accuracy @ IPN, TA = 25°C (excluding offset) Linearity error (1% of IPN .. ± IPN) Output current @ IP=0, TA = 25°C Electrical offset current @ TA = 25°C Temperature coefficient of IOE ( 0..+60 °C) (-40..+70 °C) Temperature coefficient of IOUT (% of reading) Response time to 90 % of IPN step Frequency bandwidth (± 1 dB) < ± 1 % of IPN < ± 1.0 % of IPN 4 mA+/- IOE < ± 1.0 % of IPN ± 3.2 mA/K ± 6.4 mA/K ± 0.1 %/K < 150 ms DC 20..6000 Hz General data TA TS m IPxx Surrounding operating temperature Surrounding storage temperature Mass Protection degree - 40 .. + 70 - 40 .. + 85 260 IP20 °C °C g Notes : 1) The Max. Peak AC Current is the highest peak level of the primary signal that is taken into account for accurate True RMS calculation. Yet the device is designed for maximum continuous True RMS value equal to IPN, whereas the output is limited by the above specified output limitation. 2) According to the UL 508 Standard for Safety for Industrial Control Equipment, the supply voltage must not exceed 42VDC. ●● VFD and SCR waveforms current measurement ●● True RMS output ●● 4-20 mA current output ●● Panel mounting ●● Eliminates insertion loss ●● Isolated plastic case recognized according to UL94-V0 Advantages ●● Large aperture for cable up to Ø32mm ●● High isolation between primary and secondary circuits ●● Easy installation Applications ●● VFD Controlled Loads VFD output indicates how the motor and attached load are operating. ●● SCR Controlled Loads Acurate measurement of phase angle fired or burst fired (time proportioned) SCRs. Current measurement gives faster response than temperature measurement. ●● Switching Power Supplies and Electronic Ballasts True RMS sensing is the most accurate way to measure power supply or ballast input power. Application domain ●● Energy and Automation Page 1/4 120426/21 LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice. www.lem.com Current Transducer DHR-C420 Isolation characteristics Vb Vd Vw dCp dCl CTI Rated isolation voltage rms 3) 300 V according to the standard IEC 61010-1 and with the following conditions: - Reinforced isolation - Over voltage category CAT III - Pollution degree PD2 - Heterogeneous field Rms voltage for AC isolation test 4), 50 Hz, 1min 4.0 kV Impulse withstand voltage 4), 1.2/50 uS 7.3 kV Creepage distance 7.2 mm Clearance distance 7.2 mm Comparative tracking index (Group I) > 600 Notes :3) Between primary conductor voltage and ground. The voltage category could be improved according to the insulation characteristic given by the cable manufacturer. The UL 508 Standard for Safety for Industrial Control Equipment requires that only insulated conductors are used as primary circuit with this transducer. 4) Between primary (completely filling the aperture) and secondary. Transfer characteristics Output in mA 20 4 -Ipn +Ipn Page 2/4 120426/21 LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice. www.lem.com Current Transducer DHR-C420 Safety and warning notes In order to guarantee safe operation of the transducer and to be able to make proper use of all features and functions, please read these instructions thoroughly! Safe operation can only be guaranteed if the transducer is used for the purpose it has been designed for and within the limits of the technical specifications. Ensure you get up-to-date technical information that can be found in the latest associated datasheet under www.lem.com. Caution! Risk of danger Ignoring the warnings can lead to serious injury and/or cause damage! The electric measuring transducer may only be installed and put into operation by qualified personnel that have received an appropriate training. The corresponding national regulations shall be observed during installation and operation of the transducer and any electrical conductor. The transducer shall be used in electric/electronic equipment with respect to applicable standards and safety requirements and in accordance with all the related systems and components manufacturers’ operating instructions. Caution! Risk of electrical shock When operating the transducer, certain parts of the module may carry hazardous live voltage (e.g. primary conductor, power supply). The user shall ensure to take all measures necessary to protect against electrical shock. The transducer is a built-in device containing conducting parts that shall not be accessible after installation. A protective enclosure or additional insulation barrier may be necessary. The transducer shall not be put into operation if the jaw opening is open (split core version) or the installation is not completed. Installation and maintenance shall be done with the main power supply disconnected except if there are no hazardous live parts in or in close proximity to the system and if the applicable national regulations are fully observed. Safe and trouble-free operation of this transducer can only be guaranteed if transport, storage and installation are carried out correctly and operation and maintenance are carried out with care. Page 3/4 120426/21 LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice. www.lem.com Dimensions DHR-C420 (in mm. 1 mm = 0.0394 inch) 25 70 Dimensions DHR-C420 (in mm. 60 1 mm = 0.0394 inch) 4. 60 25 40 40 4 22.28 20.34 10 2.50 15 25 8.30 22.28 90 6.80 8.30 6.80 10 70 32 25 15 6.80 6.80 4. 60 70 32 70 60 15 25.60 2.50 4 15 25.60 7 78 6 8.30 6 4.60 33.80 8.30 4.60 33.80 90 Plug connector: Plugin in connector: FKC2.5/4-ST-5.08 FKC 2.5/4-ST-5.08-RF (Phoenix Contact) (Phoenix Contact) 78 DHR-C420 Connections Connections ●● Wires up to Ø 2 mm DHR • Wires to ∅ 2connector mm ●● up Female provided (spring terminal blocks) (springconnection terminal blocks) • Female connector provided ●● User-friendly spring-cage for no-tool direct • User-friendly spring-cage connection for no-tool conductor connection direct conductor connection Output Connector 1(Vcc) 2(Iout) 3(NC) 4(GND) Mechanical characteristics 24 VDC Power ●● General tolerance Mechanical characteristics ±1 mm ●● Primary aperture Ø 32.0 mm • General tolerance ±1 mm ●● Panel mounting 4 holes Ø 4.6 mm • Primary aperturebetween holes ∅ 32.0 mm 70.0 mm & 78 mm ●● Distance • Panel mounting 4 holes ∅ 4.6 mm (see above dimensions) • Distance holes 70 M4 mm screws & 78 mm Forbetween panel mounting, use (not supplied) with (see above drawings) appropriate length to panel´s thickness, and tighten to For panel0.75Nm mounting, replace M4 screws by new one (not supplied) +/-20% torque. (+) (-) (-) (+) Load with appropriate length to panel´s thickness. (Controller, meter etc) Remarks ●● The temperature of the primary busbar can not exceed Remarks 90 °C. OUT Is +24VDC Ip GND 120426/21 080725/16 • The ●temperature of the primary conductor canwith not a exceed 90 °C. ● Dynamic performances are the best primary • Dynamic performances arefilling the best a primary conductor busbar completely the with primary aperture. completely the primary aperture. ●● Thisfilling is a standard model. For different versions • This is (supply a standard model. For different versions (supply voltages, voltages, different outputs, bidirectional differentmeasurements...), outputs, bidirectional measurement,...), please contact us. please Page 4/4 contact us. LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice. LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice. Page 4/4 www.lem.com www.lem.com