MPD MB2024D-15ERW Low cost, 1 x 2 inch 20w, 2:1 input range dc/dc con vert er Datasheet

MB2000ERW
Low Cost, 1 x 2 Inch
20W, 2:1 Input Range
DC/DC Converters
Electrical Specifications
Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Key Features:
• 20W Output Power
• EN 60950 Approval (Pending)
Input
Parameter
Input Voltage Range
• 2:1 Input Voltage Range
Input Start Voltage
• 1,500 VDC Isolation
Input Filter
Start-Up Time
• Single & Dual Outputs
• Compact 1 x 2 Inch Case
• -40°C to +85°C Operation
Line Regulation, VIN = Min to Max
Conditions
Typ.
±1.0
±10
±0.2
±0.5
±0.5
±0.5
Min.
See Note 3
• Industry Standard Pin-Out
• Low Cost
Typ.
24.0
48.0
Max.
36.0
75.0
18.0
36.0
10
Units
VDC
VDC
mS
Output
Parameter
Output Voltage Accuracy
Output Trim Range
• Efficiency to 90%
Conditions
Min.
24 VDC Input 18.0
48 VDC Input 36.0
12 VDC Input
24 VDC Input
(Pi) Filter
See Note 2
Load Regulation, IOUT = 5% to 100%
Cross Regulation
Ripple & Noise (20 MHz)
Transient Recovery Time, See Note 6
Transient Response Deviation
Temperature Coefficient
Over Voltage Protection
Output Power Protection
Output Short Circuit, See Note 7
Positive Output
Negative Output
Positive Output
Negative Output
See Note 4
See Note 5
50
300
±5.0
±3.0
3.3, 5.0 & ±5.0 Output Models
All Other Models
110
110
Continuous (Autorecovery)
Max.
±3.0
±0.5
±1.0
±1.0
±1.5
±5.0
100
500
±8.0
±5.0
±0.03
160
190
Units
%
%
%
%
%
mV P - P
µS
%
%/°C
%
%
General
Parameter
Isolation Voltage
Isolation Resistance
Conditions
Isolation Capacitance, 100 kHz, 0.1V
60 Seconds
500 VDC
Model MB2024S-24ERW
All Other Models
Min.
1,500
1,000
Typ.
Max.
2,050
1,050
270
Switching Frequency
Units
VDC
M
pF
kHz
Environmental
Parameter
Operating Temperature Range
Storage Temperature Range
Cooling
Humidity
Physical
Case Size
Case Material
Weight
Conditions
Min.
Typ.
-40
+25
-55
Free Air Convection
RH, Non-condensing
Ambient
Max.
+85
+125
Units
°C
°C
95
%
See Mechanical Diagrams (Pages 4,5 & 6)
Aluminum Alloy With Non-Conductive Base (UL94-V0)
See Mechanical Diagrams (Pages 4,5 & 6)
Remote On/Off
MicroPower Direct
292 Page Street
Suite D
Stoughton, MA 02072
USA
T: (781) 344-8226
F: (781) 344-8481
E: [email protected]
W: www.micropowerdirect.com
Parameter
Unit On
Unit Off
Off Idle Current
Conditions
See Note 8
See Note 8
Min.
3.5
0
Typ.
4.0
Max.
12.0
1.2
7.0
Units
VDC
VDC
mA
Reliability Specifications
Parameter
MTBF
Vibration
Safety Standards
Conditions
Min.
Typ.
Max.
MIL HDBK 217F, 25°C, Gnd Benign
1.0
10 - 55 Hz, 10G, 30 Min, on X, Y & Z Axis
UL 60950, EN 60950 (Pending)
Units
MHours
Absolute Maximum Ratings
Parameter
Input Voltage Surge (1 Sec)
Lead Temperature
Conditions
24 VDC Input
48 VDC Input
1.5 mm From Case for 10 Sec
Min.
Typ.
Max.
50.0
100.0
300
Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings.
www.micropowerdirect.com
Units
VDC
°C
www.micropowerdirect.com
Model Selection Guide
Input
Model
Number
MB2024S-03ERW
MB2024S-05ERW
MB2024S-09ERW
MB2024S-12ERW
MB2024S-15ERW
MB2024S-24ERW
MB2024D-05ERW
MB2024D-09ERW
MB2024D-12ERW
MB2024D-15ERW
MB2048S-03ERW
MB2048S-05ERW
MB2048S-09ERW
MB2048S-12ERW
MB2048S-15ERW
MB2048S-24ERW
MB2048D-05ERW
MB2048D-12ERW
MB2048D-15ERW
Voltage (VDC)
Nominal
24
24
24
24
24
24
24
24
24
24
48
48
48
48
48
48
48
48
48
Output
Current (mA)
Voltage
Range
Full-Load No-Load (VDC)
18.0 - 36.0
799
40
3.3
18.0 - 36.0
969
40
5.0
18.0 - 36.0
947
6
9.0
18.0 - 36.0
947
6
12.0
18.0 - 36.0
947
6
15.0
18.0 - 36.0
947
6
24.0
18.0 - 36.0
969
40
±5.0
18.0 - 36.0
947
6
±9.0
18.0 - 36.0
947
6
±12.0
18.0 - 36.0
947
6
±15.0
36.0 - 75.0
400
25
3.3
36.0 - 75.0
485
25
5.0
36.0 - 75.0
474
9
9.0
36.0 - 75.0
474
9
12.0
36.0 - 75.0
474
9
15.0
36.0 - 75.0
474
9
24.0
36.0 - 75.0
485
25
±5.0
36.0 - 75.0
474
9
±12.0
36.0 - 75.0
474
9
±15.0
Notes:
1. The specified maximum capacitive load is for each output.
2. Start up time is measured at nominal input and with a constant resistive load.
3. For ±5 and ±9 VOUT models, the output accuracy is specified as ±5%.
4. Cross regulation is measured with the main output set at 50% load. The second output is varied from
10% to 100% load.
5. When measuring output ripple, it is recommended that an external ceramic capacitor (approx 10 µF)
be placed from the +VOUT to the -VOUT pins.
6. Transient recovery is measured to within a 1% error band for a load step change of 25%.
7. Short circuit protection is provided by a “hiccup mode” circuit.
8. The control input (pin 6) is referenced to the -VIN (pin 2) input. If it is grounded, the unit will shut off.
9. Operation at no-load will not damage the unit, but they may not meet all specifications.
10. These units should not be operated over +85°C. Exceeding +85°C may damage the unit.
11. It is recommended that a fuse be used on the input of a power supply for protection. See the Model
Selection table above for the correct rating.
Current
Current
(mA, Max)
(mA, Min)
5,000
4,000
2,222
1,667
1,333
834
±2,000
±1,111
±834
±667
5,000
4,000
2,222
1,667
1,333
834
±2,000
±834
±667
Fuse Rating
Efficiency Capacitive
Load
Slow-Blow
(%, Typ)
0.0
0.0
0.0
0.0
0.0
0.0
±0.0
±0.0
±0.0
±0.0
0.0
0.0
0.0
0.0
0.0
0.0
±0.0
±0.0
±0.0
(µF, Max)
(mA)
10,000
10,000
4,700
1,600
1,000
500
4,800
1,000
800
625
10,000
10,000
4,700
1,600
1,000
500
4,800
800
625
2,000
2,000
2,000
2,000
2,000
2,000
2,000
2,000
2,000
2,000
1,000
1,000
1,000
1,000
1,000
1,000
1,000
1,000
1,000
86
90
89
89
90
90
86
88
88
88
86
90
89
89
90
90
86
88
89
Derating Curve
External Trim
External Trim Notes:
On single output units, an external resistor can be used to adjust the converter
output up/down by about 10%. The connection is shown in the diagram at left. The
required resistor value is calculated by the formulas:
Trim UP = RTRIM = A $-R2 - R3
R2 A
Trim Down = RTRIM = A $-R1 - R3
R1 A
Where A =
VREF
$ R1
VTRIM - VREF
Where A = VTRIM VREF $ R2
VREF
Where RTRIM = The value of the external trim resistor
VTRIM = The amount of voltage adjustment required
The value of R1, R2, R3 and VREF are given in the table below.
Parameter
Output Voltage (VDC)
3.3
5.0
9.0
12
15
24
R1 (k)
4.801
2.883
7.500
11.000
14.494
24.872
R2 (k)
2.870
2.870
2.870
2.870
2.870
2.870
R3 (k)
12.40
10.00
15.00
15.00
15.00
17.80
VREF (V)
1.24
2.50
2.50
2.50
2.50
2.50
If not used, the Trim pin (pin 4) should be left open. Please contact the factory for more information.
MicroPower Direct
•
292 Page Street Ste D Stoughton, MA 02072
• TEL: (781) 344-8226 • FAX: (781) 344-8481 • E-Mail: [email protected]
www.micropowerdirect.com
EMC Specifications
Parameter
Radiated Emissions
Conducted Emissions
ESD
RS
EFT
Surge
CS
Voltage Dips
Standard
See Note 1
EN 55022
See Note 1
EN 55022
EN 61000-4-2
EN 61000-4-3
See Note 2
EN 61000-4-4
See Note 3
EN 61000-4-5
EN 61000-4-6
EN 61000-4-29
Class A
Class A
Criteria B; ±4 kV Contact
Criteria A; 10V/m
Criteria B; ±2 kV
Criteria B; ±2 kV
Criteria A; 3 Vrms
Criteria B; 0% - 70%
Notes:
1. All units are rated for EN 55022 (CE/RE) class A without external components.
They will meet class B with the addition of the MDCFM-xxW (or a similar discrete
filter circuit). Contact the factory for more information.
2. To meet the requirements of EN 61000-4-4 (±2 kV), external components are
needed. This can be done discretely, or with the addition of the MDCFM-xxW.
Contact the factory for more information.
3. To meet the requirements of EN 61000-4-5 (±2 kV line to line), external
components are needed. This can be done discretely, or with the addition of the
MDCFM-xxW. Contact the factory for more information.
Typical Connection
6. In many applications simply
The diagram above illustrates a typical connection of the MB2000ERW 4. Recommended values for components are:
Vin
Input
Vout
Output
adding input/output capaciseries for applications that require meeting EMC standards. The units do not Component
(VDC) Capacitor (VDC) Capacitor
48 VIN
24 VIN
tors will enhance the input
require external components to operate as specified. Some notes on this
MOV
S20K30
S14K60
3.3
470 µF
surge protection and reduce
diagram (starting with the input circuit) are:
24
100 µF
5.0
470 µF
C1
330 µF/50V
330 µF/100V
output ripple sufficiently. The
1. It is recommended that an external fuse be used. The recommended fuse
input capacitor C1 and output
9.0
220 µF
is shown in the model chart on page 2.
C2
1.0 µF/50V
1.0 µF/100V
48
100
µF
capacitor C3 shown in the
2. An external MOV is recommended on the input to protect the unit in the
12
220 µF
L1
4.7 µH
4.7 µH
typical connection diagram
event of a surge. A recommended value is given in the table at right.
15
220 µF
CY1, CY2
1,000 pF/2 kV
1,000 pF/2 kV
above illustrate their connec3. The output filtering capacitor (C3) is a high frequency, low resistance
24
100 µF
tion. Recommended capacitor
electrolytic capacitor. Care must be taken in choosing this capacitor not 5. Input noise and surge suppression modules are available for a
±5
±220 µF
values
are
given
in
the
table
to exceed the capacitive load specification for the unit. The board layout
number of MPD DC/DC power supplies. For pricing or full techni±9
±100 µF
at right.
illustration below shows a connection for dual output units. Voltage derating
cal information on these modules please contact the factory.
±12
±100 µF
of capacitors should be 80% or above.
±15
±100 µF
Efficiency vs Input Voltage: (FL, 24 VIN)
Efficiency vs Input Voltage: (FL, 48 VIN)
Efficiency vs Output Load: (24 VIN)
Efficiency vs Output Load: (48 VIN)
MicroPower Direct
•
292 Page Street Ste D Stoughton, MA 02072
• TEL: (781) 344-8226 • FAX: (781) 344-8481 • E-Mail: [email protected]
Mechanical Dimensions
www.micropowerdirect.com
Pin Connections
Pin
1
2
3
4
5
6
Single Output
+VIN
-VIN
+VOUT
Trim
-VOUT
Remote On/Off
Pin
1
2
3
4
5
6
Dual Output
+VIN
-VIN
+VOUT
Common
-VOUT
Remote On/Off
Notes:
• All dimensions are typical in inches (mm)
• Tolerance x.xx = ±0.02 (±0.50)
• Weight (Typ) = 0.92 Oz (26g)
Mechanical Dimensions: With Optional Heatsink
For the heatsink option, add suffix “H” to the
model number (i.e. MB2024S-05ERW-H)
Notes:
• All dimensions are typical in inches (mm)
• Tolerance x.xx = ±0.02 (±0.50)
• Weight (Typ) = 1.20 Oz (34g)
MicroPower Direct
•
292 Page Street Ste D Stoughton, MA 02072
• TEL: (781) 344-8226 • FAX: (781) 344-8481 • E-Mail: [email protected]
Mechanical Dimensions: A2 Chassis Mount Adapter
www.micropowerdirect.com
Notes:
• All dimensions are typical in inches (mm)
• Tolerance x.xx = ±0.02 (±0.50)
• Weight (Typ) = 1.69 Oz (48g)
Mechanical Dimensions: A4 DIN Rail Adapter
Pin Connections
Pin
1
2
3
4
5
6
Notes:
• All dimensions are typical in inches (mm)
• Tolerance x.xx = ±0.02 (±0.50)
• Weight (Typ) = 2.40 Oz (68g)
MicroPower Direct
•
292 Page Street Ste D Stoughton, MA 02072
Single Output
Dual Output
Remote On/Off
-VIN
-VIN
+VIN
+VIN
-VOUT
-VOUT
Trim (•)
Common
+VOUT
+VOUT
For the chassis mount option, add suffix “A2” to the
model number (i.e. MB2024D-09ERW-A2)
For the DIN rail mount option, add suffix “A4” to the
model number (i.e. MB2024D-09ERW-A4)
• TEL: (781) 344-8226 • FAX: (781) 344-8481 • E-Mail: [email protected]
Mechanical Dimensions: A2 Chassis Mount Adapter
www.micropowerdirect.com
icropowerdirect.com
Notes:
• All dimensions are typical in inches (mm)
• Tolerance x.xx = ±0.02 (±0.50)
• Weight (Typ) = 1.98 Oz (56g)
Mechanical Dimensions: A4 DIN Rail Adapter
Notes:
• All dimensions are typical in inches (mm)
• Tolerance x.xx = ±0.02 (±0.50)
• Weight (Typ) = 2.68 Oz (76g)
Pin Connections
Pin
1
2
3
4
5
6
MicroPower Direct
We Power Your Success - For Less!
292 Page Street Ste D Stoughton, MA 02072
•
TEL: (781) 344-8226
•
Single Output
Dual Output
Remote On/Off
-VIN
-VIN
+VIN
+VIN
-VOUT
-VOUT
Trim (•)
Common
+VOUT
+VOUT
For the chassis mount option, add suffix “A2” to the
model number (i.e. MB2048S-12ERW-A2 -H)
For the DIN rail mount option, add suffix “A4” to the
model number (i.e. MB2048S-12ERW-A4-H)
FAX: (781) 344-8481
•
E-Mail: [email protected]