AIMTEC AME2-15SAZ Optional 90-528vac, 47-440hz, or 130-745 vdc Datasheet

Click on Series name for product info on aimtec.com
Series AME2-AZ
2Watt | AC-DC Converter
FEATURES:
•
•
•
•
•
Models
Single output
I/O Isolation 3000VAC
Operating Temp: -40°C to +70°C
Input: 90-305VAC, 47-440Hz, or 130-430 VDC
Optional 90-528VAC, 47-440Hz, or 130-745 VDC
Over load, Short Circuit Protection
Input
Voltage
(VAC/Hz)
Input
Voltage
(VDC)
AME2-3.3SAZ
AME2-5SAZ
AME2-12SAZ
AME2-15SAZ
AME2-24SAZ
90-305/47-440
90-305/47-440
90-305/47-440
90-305/47-440
90-305/47-440
130-430
130-430
130-430
130-430
130-430
-40 to
-40 to
-40 to
-40 to
-40 to
AME2-3.3SBAZ
AME2-5SBAZ
AME2-12SBAZ
AME2-15SBAZ
AME2-24SBAZ
90-528/47-440
90-528/47-440
90-528/47-440
90-528/47-440
90-528/47-440
130-745
130-745
130-745
130-745
130-745
-40 to
-40 to
-40 to
-40 to
-40 to
Model
Input Specifications
Parameters
Current (full load)
Inrush current <2ms (cold start)
Leakage current
External fuse
Input Dissipation (No Load)
Output Specifications
Parameters
Voltage accuracy
Line regulation
Load regulation (single output)
Transient Recovery Time
Transient Response Deviation
Minimum load
• RoHS compliant
• Energy Star compliant
• Ultra small package
Output
Voltage
(V)
Output
Current max
(mA)
Maximum
capacitive
Load
(µF)
+70
+70
+70
+70
+70
3.3
5
12
15
24
600
400
166
133
83
+70
+70
+70
+70
+70
3.3
5
12
15
24
600
400
166
133
83
Temperature
range
(ºC)
Conditions
Typical
115 VAC
230 VAC
277 VAC
480VAC
115 VAC
230 VAC
277 VAC
480 VAC
Efficiency
(%)
115
230
277
480
VAC
VAC
VAC
VAC
2200
1100
680
560
470
64
67
75
78
81
63
66
72
74
81
61
63
69
71
79
2200
1100
680
560
470
57
63
68
68
67
57
63
68
67
67
56
62
66
66
65
Maximum
40
20
20
15
10
15
20
30
0.15
Recommended slow blow type
Conditions
Maximum
±5
±1.5
±5
200
25% load step
±2
0
3.3/5 VAC With 560µF E/C
200
Ripple & Noise
12/15 VAC With 220µF E/C
400
24 VAC With 220µF E/C
500
*Ripple & Noisemeasured at 20MHz bandwidth with 0.1µF and 115/230/277/480 VAC( Typical input ) with Full Load
Isolation Specifications
Parameters
Tested I/O voltage
Isolation Resistance
www.aimtec.com
F 052e R8.I
Full load (typical)*
LL-HL, Full Load
0-100% load (typical)*
Conditions
Typical
60 sec
>1000
Tel: +1 514 620 2722
1 of 3
Units
mA
mA
mA
mA
A
A
A
A
mA
A
W
1
≦0.3
Typical
50
56
53
57
58
Units
%
%
%
µs
% of Vout
%
mV p-p
mV p-p
mV p-p
Rated
Units
3000
VAC
MΩ
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AME2-AZ
2Watt | AC-DC Converter
General Specifications
Parameters
Conditions
Typical
Maximum
Units
Switching frequency
100
KHz
Over Load protection
Auto recovery
>125%
Short circuit protection
Auto recovery
o
Operating temperature
Without derating
-40 to +70
C
o
Storage temperature
-40 to +85
C
o
Maximum Case temperature
100
C
Humidity
Non condensing
20 ~ 95
% RH
Case material
Plastic resin + Fiberglass (flammability to UL 94V-0)
Weight
25
g
Dimensions (L x W x H)
1.40 x 0.92 x 0.76 (35.60 x 23.31 x 19.32mm)
MTBF
> 400 000 hrs (MIL-HDBK -217F, t=+25oC)
NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load
unless otherwise specified.
Environment Approval
Parameters
Conditions
Wave form: Half sine wave
Acceleration amplitude: 5gn
Shock
Bump duration: 30 ms
Number of bumps: 18 (3 in each direction for every axis)
Converter operation before and after test, body mounted (on chassis)
Test mode: Sweep sine
10-100Hz, speed 0.05Hz/s
Displacement: 1mm
Vibrations
Acceleration: 3g
3 loops 30min one cycle, 3h total, every axis tested
Converter operation before and after test, body mounted (on chassis)
Safety Specifications
Parameters
Agency approvals
Standards
cULus, CE, CB, FCC
Information technology Equipment
EMI - Conducted and radiated emission
Harmonic Current Emissions
Voltage fluctuations and flicker
Electrostatic Discharge Immunity
RF, Electromagnetic Field Immunity
Electrical Fast Transient/Burst Immunity
Surge Immunity (1KV)
RF, Conducted Disturbance Immunity
Power frequency Magnetic Field Immunity
Voltage dips, Short Interruptions Immunity
IEC/EN/UL 60950-1:2006+A11:2009
EN55022, class B (* see note)
IEC/EN 61000-3-2, Class A
IEC/EN 61000-3-3, (EN60555-3)
IEC 61000-4-2
IEC 61000-4-3
IEC 61000-4-4
IEC 61000-4-5(SAZ: Level 2,SBAZ: Level 1)
IEC 61000-4-6
IEC 61000-4-8
IEC 61000-4-11
FCC part 15 Subpart B, Class B, ANSI C63.4 :2003
* Note: for 528VAC models to meet the EN55022 class B spec an external 0.33uF X capacitor is needed to be installed between AC L and AC N as close
as possible to the input of the power supply itself
Pin Out Specifications*
Pin
Single
1*
2*
3
4
AC Input (N) or (L1)
AC Input (L) or (L2)
-V Output
+V Output
* Note: Input Pins 1 and 2 can be “N” and "L" respectively when the input voltage is supplied from a single phase.
Input Pins 1 and 2 can be “L1” and "L2" respectively when the input voltage is supplied from 3 phase line to line voltage 208-480Vac (208 Y/ 120V 3-phase,
240 Y/ 120V 3-phase, 400 Y/ 230V 3-phase or 480 Y/ 277V 3-phase).
www.aimtec.com
F 052e R8.I
Tel: +1 514 620 2722
2 of 3
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AME2-AZ
2Watt | AC-DC Converter
Derating
Free Air Convection
70 ºC
Output Power %
100
80
60
Safe Operating Area
40
20
70
0
-40
-20
0
20
40
60
80
100
Ambient Temperature º C
Dimensions
17.80
(0.70)
35.60
(1.40)
Top Vi ew
1
15.24
1
3
Top View
(0.60)
7.60
(0.29)
4
Temperaturem easuring point
3
11.655
(0.46)
23.31
4
(0.92)
2
2
28.00
DIV: 5.00(0.20)
(1.10)
Ø 10.0 ( Ø 0.40)
Ø 0.60 ( Ø 0.02)
19.32
Side View
(0.76)
Dimensions mm (inch)
Case Tolerance ±0.50 (±0.02)
Pin Diameter ±0.05 (±0.002)
Pin Pitch Tolerance ±0.50 (±0.02)
6.00
(0.24)
0.60
(0.02)
NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled
by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the
date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of 25°C, humidity<75%,
nominal input voltage and at rated output load unless otherwise specified. 5. Aimtec may not have conducted destructive testing or chemical analysis on all internal components
and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 6. This
product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate
specific safety and regulatory standards other the ones listed in this datasheet. 7. Warranty is in accordance with Aimtec’s standard Terms of Sale available at www.aimtec.com.
www.aimtec.com
F 052e R8.I
Tel: +1 514 620 2722
3 of 3
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only