Diodes HD03-T 0.8a surface mount glass passivated bridge rectifier Datasheet

HD01 – HD06
0.8A SURFACE MOUNT GLASS PASSIVATED BRIDGE RECTIFIER
Features and Benefits
Mechanical Data
•
•
•
•
•
•
•
•
•
Glass Passivated Die Construction
Low Forward Voltage Drop
Surge Overload Rating to 30A Peak
Ideally Suited for Automated Assembly
Miniature Package Saves Space on PC Boards
UL Listed Under Recognized Component Index, File Number
E94661
Lead Free Finish, RoHS Compliant (Note 1)
Case: MiniDIP
Case Material: Molded Plastic. UL Flammability Classification
Rating 94V-0
Moisture Sensitivity: Level 1 per J-STD-020
Terminals: Finish ⎯ Tin. Plated Leads, Solderable per MIL-STD202, Method 208
Polarity: As Marked on Case
Marking: Type Number, Date Code & Polarity Markings
Weight: 0.125 grams (approximate)
•
•
•
•
•
Equivalent Circuit
Ordering Information (Note 2)
Device*
HDxx-T
Packaging
MiniDIP
Shipping
3K/Tape & Reel, 13-inch
*xx = Device type, e.g. HD02-T or HD04-T, etc.
Notes:
1. EU Directive 2002/95/EC (RoHS). All applicable RoHS exemptions applied, see EU Directive 2002/95/EC Annex Notes
2. For packaging details, visit our website at http://www.diodes.com.
Marking Information
YM
HDxx
Month
Code
Jan
1
Feb
2
HD01 – HD06
Document number: DS17003 Rev. 13 - 2
Mar
3
Apr
4
HDxx = Product Type Marking Code (ex: HD04)
YM = Date Code Marking
Y = Last Digit of the Year
M = See Month/Code Table Below
May
5
Jun
6
1 of 4
www.diodes.com
Jul
7
Aug
8
Sep
9
Oct
O
Nov
N
Dec
D
December 2010
© Diodes Incorporated
HD01 – HD06
Maximum Ratings @TA = 25°C unless otherwise specified
Single phase, half wave, 60Hz, resistive or inductive load.
For capacitive load, derate current by 20%.
Characteristic
Peak Repetitive Reverse Voltage
Working Peak Reverse Voltage
DC Blocking Voltage
Symbol
VRMM
VRWM
VDC
VRMS
IO
RMS Reverse Voltage
Average Forward Rectified Current (Note 3) @TA = 40°C
Non-Repetitive Peak Forward Surge Current, 8.3 ms
Single Half Sine-Wave Superimposed on Rated Load
HD01
HD02
HD04
HD06
Unit
100
200
400
600
V
70
140
280
420
0.8
V
A
30
A
IFSM
Thermal Characteristics
Characteristic
Typical Thermal Resistance, Junction to Ambient (Note 3)
Operating and Storage Temperature Range
Symbol
RθJA
TJ, TSTG
Value
75
-55 to +150
Unit
°C/W
°C
Value
1.0
5.0
500
10
Unit
V
Electrical Characteristics @TA = 25°C unless otherwise specified
Characteristic
Instantaneous Voltage Drop @ 0.4A (per element)
Peak Reverse Current at Rated @TA = 25°C
DC Blocking Voltage (per element) @TA = 125°C
Typical Total Capacitance (per element) (Note 4)
IR
CT
0.8
IF(AV), AVERAGE FORWARD CURRENT (A)
μA
pF
3. Mounted on PC Board.
4. Measured at 1.0 MHz and applied reverse voltage of 4.0V.
IF, INSTANTANEOUS FORWARD CURRENT (A)
Notes:
Symbol
VF
0.6
0.4
0.2
10
1.0
0.1
0.01
0
0
40
80
120
TA, AMBIENT TEMPERATURE (° C)
Fig. 1 Output Current Derating Curve
HD01 – HD06
Document number: DS17003 Rev. 13 - 2
160
0.2
0.4
0.6
0.8
1.0
1.2
1.4
1.6
VF, INSTANTANEOUS FORWARD VOLTAGE (V)
Fig. 2 Typical Forward Characteristics (per element)
2 of 4
www.diodes.com
December 2010
© Diodes Incorporated
HD01 – HD06
100
Tj = 25°C
f = 1.0MHz
30
CT, TOTAL CAPACITANCE (pF)
IFSM, PEAK FORWARD SURGE CURRENT (A)
35
20
10
10
1
0
1
1.0
10
100
NUMBER OF CYCLES AT 60 Hz
Fig. 3 Maximum Peak Forward Surge Current (per element)
10
100
VR, REVERSE VOLTAGE (V)
Fig. 4 Typical Total Capacitance (per element)
100
Tj = 125°C
10
1.0
T j = 25° C
0.1
0.01
0
40
20
60
80
100
120
140
PERCENT OF RATED PEAK REVERSE VOLTAGE (%)
Fig. 5 Typical Reverse Characteristics (per element)
Package Outline Dimensions
L
G
A
H
B
D
E
C
J
MiniDIP
Dim
Min
Max
A
5.43
5.75
B
3.6
4.0
C
0.15
0.35
D
0.05
0.20
E
7.0
⎯
G
0.70
1.10
H
4.5
4.9
J
2.3
2.7
K
2.3
2.7
L
0.50
0.80
All Dimensions in mm
K
HD01 – HD06
Document number: DS17003 Rev. 13 - 2
3 of 4
www.diodes.com
December 2010
© Diodes Incorporated
HD01 – HD06
IMPORTANT NOTICE
DIODES INCORPORATED MAKES NO WARRANTY OF ANY KIND, EXPRESS OR IMPLIED, WITH REGARDS TO THIS DOCUMENT,
INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE
(AND THEIR EQUIVALENTS UNDER THE LAWS OF ANY JURISDICTION).
Diodes Incorporated and its subsidiaries reserve the right to make modifications, enhancements, improvements, corrections or other changes
without further notice to this document and any product described herein. Diodes Incorporated does not assume any liability arising out of the
application or use of this document or any product described herein; neither does Diodes Incorporated convey any license under its patent or
trademark rights, nor the rights of others. Any Customer or user of this document or products described herein in such applications shall assume
all risks of such use and will agree to hold Diodes Incorporated and all the companies whose products are represented on Diodes Incorporated
website, harmless against all damages.
Diodes Incorporated does not warrant or accept any liability whatsoever in respect of any products purchased through unauthorized sales channel.
Should Customers purchase or use Diodes Incorporated products for any unintended or unauthorized application, Customers shall indemnify and
hold Diodes Incorporated and its representatives harmless against all claims, damages, expenses, and attorney fees arising out of, directly or
indirectly, any claim of personal injury or death associated with such unintended or unauthorized application.
Products described herein may be covered by one or more United States, international or foreign patents pending. Product names and markings
noted herein may also be covered by one or more United States, international or foreign trademarks.
LIFE SUPPORT
Diodes Incorporated products are specifically not authorized for use as critical components in life support devices or systems without the express
written approval of the Chief Executive Officer of Diodes Incorporated. As used herein:
A. Life support devices or systems are devices or systems which:
1. are intended to implant into the body, or
2. support or sustain life and whose failure to perform when properly used in accordance with instructions for use provided in the
labeling can be reasonably expected to result in significant injury to the user.
B. A critical component is any component in a life support device or system whose failure to perform can be reasonably expected to cause the
failure of the life support device or to affect its safety or effectiveness.
Customers represent that they have all necessary expertise in the safety and regulatory ramifications of their life support devices or systems, and
acknowledge and agree that they are solely responsible for all legal, regulatory and safety-related requirements concerning their products and any
use of Diodes Incorporated products in such safety-critical, life support devices or systems, notwithstanding any devices- or systems-related
information or support that may be provided by Diodes Incorporated. Further, Customers must fully indemnify Diodes Incorporated and its
representatives against any damages arising out of the use of Diodes Incorporated products in such safety-critical, life support devices or systems.
Copyright © 2010, Diodes Incorporated
www.diodes.com
HD01 – HD06
Document number: DS17003 Rev. 13 - 2
4 of 4
www.diodes.com
December 2010
© Diodes Incorporated
Similar pages