DC-DC Converter SIP-Package DBV-1 SERIES, 1WATT, REGULATED WITH 2:1 INPUT RANGE FEATURES: 3 years warranty 1500Vdc isolation voltage Wide (2:1) input voltage range Regulated isolated twin output models Operating temperature range -40°C to +85°C Continuous short circuit protection Model Input voltage (Vdc) Output voltage (Vdc) Output current (mA) Min. Max. Efficiency Typ. DBV1-0501 5, 5 10 100 80% DBV1-0502 9, 9 5.5 55 80% 12, 12 4.0 40 80% DBV1-0504 15, 15 3.3 33 80% DBV1-0505 24, 24 2.1 21 80% DBV1-1201 5, 5 10 100 80% DBV1-1202 9, 9 5.5 55 80% 12, 12 4.0 40 80% DBV1-1204 15, 15 3.3 33 80% DBV1-1205 24, 24 2.1 21 80% DBV1-2401 5, 5 10 100 80% DBV1-2402 9, 9 5.5 55 80% 12, 12 4.0 40 80% DBV1-2404 15, 15 3.3 33 80% DBV1-2405 24, 24 2.1 21 80% DBV1-0503 DBV1-1203 DBV1-2403 5(4.5~9) 12(9~18) 24(18~36) Notes: other input and output models may available on request. ELECTRICAL Line regulation --- ±0.2% Load regulation 10% ~ 100% full load ±0.5% Ripple and noise --- 100mVp-p max. Isolation voltage --- 1500Vdc Short circuit protection --- Continuous short circuit protection Operating temperature range --- -40°C to +85°C MTBF --- 1x106Hrs Notes: All the data in this article are under test with “TA+25°C, humidity<75%, rated input and rated load” mode. www.pairuigroup.com Page: 1/3 Date: 12/13/2013 DC-DC Converter SIP-Package DBV-1 SERIES, 1WATT, REGULATED WITH 2:1 INPUT RANGE MECHANICAL CONNECTION PIN # ISOLATED TWIN 1 GND 2 +Vin 6 +Vo1 7 -Vo1 8 CS 9 -Vo2 10 +Vo2 Note: * Unit is mm(inch). TEMPERATURE PROFILE CAPACITIVE LOADS SELECTION Single Output Cin (Vdc) (μF) 5 4.7-100 5 560 ±5 270 12 4.7-100 9 470 ±9 220 24 4.7-100 12 470 ±12 220 - - 15/24 330 ±15/±24 150/100 www.pairuigroup.com Voltage Cout Dual Output Vin (μF) (Vdc) Page: 2/3 Voltage (Vdc) Cout (μF) Date: 12/13/2013 DC-DC Converter SIP-Package DBV-1 SERIES, 1WATT, REGULATED WITH 2:1 INPUT RANGE NOTES RECOMMENDED TEST AND APPLICATION CIRCUIT In order to ensure the efficiency and dependability of the module, the minimum specified load must be less than 10% of rated load. If the output power is low, we recommend to add an external 10% loading resistor in parallel. FUSE: depends on the actual input current; TVS: depends on the actual input voltage; Recommended capacitor:C1, C2, C5,about 0.1uF; for C6,C7,C9, please check the capacitive load; C3,C4:2KV/1nF. www.pairuigroup.com Page: 3/3 Date: 12/13/2013