ACDC 400/600 Watts CCH400600 Series xppower.com • Baseplate Cooled • High Efficiency up to 90% • 40 °C to +70 °C Operation • Industrial & MILSTD461E EMC Compliance • Power Fail, Inhibit, Overtemp & Current Share • 5V Standby Output • 3 Year Warranty Specification Input General • 90-264 VAC • 47-400 Hz(1) • CCH400: 4.3/2.1 A typ. at 115/230 VAC, CCH600: 6.3/3.1 A typ. at 115/230 VAC, full load Inrush Current • 60 A max at 230 VAC, 25 °C cold start Power Factor • >0.9 Earth Leakage Current • 0.7/1.1 mA at 115/230 VAC at 60/50 Hz Input Protection • Internal F10 A/250 V fuse Input Voltage Input Frequency Input Current Switching Frequency Signals MTBF • 89% typical • 3000 VAC Input to Output, 1500 VAC Input to Ground, 500 VDC Output to Ground • 30-333 kHz PFC, 51.1 kHz main and 138 kHz standby converter • Power Fail, Inhibit, Current Share, Overtemperature Warning and 5 V Standby • 300 kHrs to MIL-HDBK-217F at 25 °C, GB Environmental Output Output Voltage Output Voltage Trim Initial Set Accuracy Minimum Load Start Up Delay Start Up Rise Time Hold Up Time Drift Line Regulation Load Regulation Over/Undershoot Transient Response • • • • • • • • • • • • Ripple & Noise • Overvoltage Protection • Overload Protection • Short Circuit Protection • Temperature Coefficient Overtemp. Protection Remote Sense Remote On/Off Efficiency Isolation • 12-48 VDC ±10% ±1% V1, ±3% V2 No minimum load required Typically 1 s 50 ms typical 20 ms min ±0.2% after 20 min warm up ±0.5% max ±1% V1, ±5% V2 max 1% typical 4% max. deviation, recovery to within 1% in 500 µs for a 50-75-50% load change Typically 1% pk-pk V1, V2 2%, 20 MHz bandwidth 110-140% Vnom, recycle input to reset 105-140% V1 only Continuous, approximately constant current 0.05%/˚C • Fitted • Compensates for 0.5 V total voltage drop • Uncommitted isolated optocoupler diode, powered diode inhibits V1 Notes 1. Safety approvals cover frequency 47-63 Hz. Operating Temperature • -40 ˚C to +70 ˚C ambient. Baseplate must be maintained ≤+85 °C, see thermal considerations Cooling • Baseplate, conduction cooling Operating Humidity • 95% RH, non-condensing Storage Temperature • -40 ˚C to +85 ˚C Operating Altitude • 3000 m Shock • MIL-STD 810F Clause 516.5 proc 1 Vibration • MIL-STD 810F figure 514.5C-17 EMC & Safety Low Voltage PSU EMC • EN61204-3, high severity level Emissions • EN55022 level B conducted, level A radiated, MIL-STD 461D-F, CE102 Harmonic Currents • EN61000-3-2, class A Voltage Flicker • EN61000-3-3 Radiated Immunity • EN61000-4-3, level 3 Perf Criteria A EFT/Burst • EN61000-4-4, level 3 Perf Criteria A Surge • EN61000-4-5, installation class 3 Perf Criteria A Conducted Immunity • EN61000-4-6, level 3 Perf Criteria A, MIL-STD 461 CS114 Dips & Interruptions • EN61000-4-11, 30% 10 ms, 60% 100 ms, 100% 5000 ms, Perf Criteria A, B, B Safety Approvals • IEC60950-1 CB report, UL60950-1, TUV EN60950-1 Equipment Protection • Class I Class Output Power 411 W 411 W 409 W 411 W 603 603 605 603 W W W W ACDC CCH400/600 Models and Ratings Output Voltage V1 12.0 VDC 24.0 VDC 28.0 VDC 48.0 VDC 12.0 24.0 28.0 48.0 Output Current V1 34.0 A 17.0 A 14.5 A 8.5 A VDC VDC VDC VDC 50.0 25.0 21.5 12.5 Standby Supply V2 5.0 V/0.5 A 5.0 V/0.5 A 5.0 V/0.5 A 5.0 V/0.5 A A A A A 5.0 5.0 5.0 5.0 V/0.5 V/0.5 V/0.5 V/0.5 Model Number CCH400PS12 CCH400PS24 CCH400PS28 CCH400PS48 A A A A CCH600PS12 CCH600PS24 CCH600PS28 CCH600PS48 Mechanical Details 8.43 (214.00) - Voltage Adjust. Pin 1 2 3 4 5 6 7 8 9 10 Output Terminals (M4) Torque 8 in-lb (0.9 Nm) max Signals Connector Exploded View Signal Connector Function Current Share Inhibit Overtemp. Warning Power Fail +Sense -Sense -Standby -Standby +Standby +Standby Pin 2 Pin 1 Pin 10 Pin 9 4.02 (102.00) 0.30 (7.72) Input Connector 3 Way AMP/Tyco Input Connector Connector: 10 WAY 2mm pitch p/n MOLEX 87833-1031 Mating half: p/n MOLEX 51110-1056 Contact: p/n MOLEX 50394-8100 Pin 1 2 3 + 1.69 (43.00) Input Connector Function Earth Neutral Line Pin 3 Pin 2 Pin 1 7.84 (199.00) 4.21 (107.00) 0.59 (15.00) M4 fixings in 6 positions Max. screw penetration to be 0.16 (4.0) from bottom face of baseplate Torque 13.2 in-lb (1.5 Nm) max Connector: 3 way AMP/Tyco type MATE-N-LOK 1-350943-0 0.177 Ø (4.50) thru in 4 positions Mates with MATE-N-LOK 350766-1 3.48 (88.4) 2.83 (72.00) Notes 1.18 (30.00) 1. All dimensions in inches (mm). 2. Tolerance .xx = ±0.02 (0.50); .xxx = ±0.01 (0.25) 3. Weight 3.3 lbs (1.5 kg) 4. Connector kit available, order part no. ‘CCH CONKIT’ 0.20 (5.00) 0.27 (6.80) 8.23 (209.00) Thermal Considerations The baseplate must be maintained below 85 °C and therefore a suitable heatsink must be selected to remove the heat from the power supply. Details of the heatsink calculations and other considerations can be found in the longform datasheet. 50 0 -40 Some specification parameters may not be met Output Load (%) 100 -20 0 +70 Ambient Temperature (ºC) 23-Jul-13