Tantalum Through-Hole Capacitors – Molded Axial T322 and T323 Series MIL–PRF–49137/1 and 5 (CX01 and CX05 Style) Overview The KEMET T322 and T323 Series (CX01 and CX05 Style) offers a complete line of extended range molded solid tantalum capacitors designed specifically for high speed automatic insertion applications. These capacitors offer an extremely high capacitance-to-volume ratio while still maintaining excellent performance characteristics. Supplied in six axial lead tubular case sizes, these capacitors are ideally suited for use in printed wiring boards and all applications requiring a high degree of packaging density and can be supplied in bulk packaging or lead-taped on reels. The 322/T323 Series dimensions and tight lead wire-to-body concentricity permit installation by the same automatic insertion equipment used for diodes and resistors. These capacitors are available in working voltages of 2, 4, 6, 10, 15, 20, 25, 35 and 50 volts. The operating temperature range -55°C to +85°C at full rated voltage and with 2/3 85°C rated voltage at 125°C. The gold color epoxy permits laser marking with outstanding permanency and legibility. T323 Series capacitors are qualified under MIL–PRF–49137/1 and 5 as Military Style CX01 and CX05. Typical applications include decoupling, blocking, bypassing and filtering in commercial computers, data processing, communications, and other electronic equipment. This product is well-suited for decoupling required by high speed computers due to its low ESR/impedance at high frequencies. Benefits Applications • • • • • Typical applications include decoupling, blocking, bypassing and filtering in commercial computers, data processing, communications, and other electronic equipment. This product is well-suited for decoupling required by high speed computers due to its low ESR/impedance at high frequencies. Taped and reeled per EIA Specification RS–296 Laser-marked case Qualified to MIL–PRF–49137/1 and 5 (CX01 and CX05 Style) Capacitance values of 0.1 μF to 330 μF Tolerances of ±5%, ±10% and ±20% (M and K only tolerances available for T323 Series) • Voltage rating of 2 – 50 VDC • Operating temperature range of -55˚C to +85˚C • Case sizes: A, B, C, D, E, F One world. One KEMET © KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 (864) 963-6300 • www.kemet.com T2039_T322_AXIAL_T323 • 9/9/2015 1 Tantalum Through-Hole Capacitors – Molded Axial T322 and T323 Series MIL–PRF 49137/1 & 5 (CX01 and CX05 Style) Ordering Information T Capacitor Class T= Tantalum 32X A 474 Series Case Size Capacitance Code (pF) Capacitance Rated Voltage Failure Rate/Military Tolerance (VDC) Product A, B, C, D, E, F First two digits represent significant figures. Third digit specifies number of zeros to follow. J = ±5% K = ±10% M = ±20% Axial Molded Polar Solid Tantalum. Insert appropriate number to replace letter ""X"" = 322 or 323 (CX01 or CX05). M 035 002 = 2 004 = 4 006 = 6 010 = 10 015 = 15 020 = 20 025 = 25 035 = 35 050 = 50 A Not Applicable T Termination Finish T = 100% tin S = standard (solder-coated nickel) Packaging (When necessary) Reeling per EIA Specification RS296 Blank = Bulk 7200 = Reel MIL–PRF–49137/1/5 (CX01 and CX05 Style) CX 05 D 225 K Capacitor Class Series Rated Voltage (VDC) Capacitance Code (pF) Capacitance Tolerance CX = MIL-PRF 01 = T322 05 = T323 D=6 F = 10 H = 15 J = 20 K = 25 M = 35 N = 50 First two digits represent significant figures. Third digit specifies number of zeros to follow. K = ±10% M = ±20% Performance Characteristics Item Performance Characteristics Operating Temperature Rated Capacitance Range Capacitance Tolerance Rated Voltage Range DF (120 Hz @ 25°C) ESR and Impedance (100 kHz @ 25°C) Leakage Current -55°C to 125°C 0.1 – 330 μF @ 120 Hz/25°C J Tolerance (5%), K Tolerance (10%), M Tolerance (20%) 2 – 50 V Refer to Part Number Electrical Specification Table Refer to Part Number Electrical Specification Table (for reference only) Refer to Part Number Electrical Specification Table (@ rated voltage up to +85°C and 2/3 of rated voltage applied at 125°C) © KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 (864) 963-6300 • www.kemet.com T2039_T322_AXIAL_T323 • 9/9/2015 2 Tantalum Through-Hole Capacitors – Molded Axial T322 and T323 Series MIL–PRF 49137/1 & 5 (CX01 and CX05 Style) Dimensions – Millimeters (Inches) Metric will govern Case Size D Maximum L Maximum W A 0.095 (2.41) 0.260 (6.6) 0.020 (.51) B 0.110 (2.79) 0.290 (7.37) 0.020 (.51) C 0.180 (4.57) 0.345 (8.76) 0.020 (.51) D 0.180 (4.57) 0.420 (10.67) 0.020 (.51) E 0.280 (7.11) 0.530 (13.46) 0.025 (.64) F 0.300 (7.62) 0.710 (18.03) 0.025 (.64) © KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 (864) 963-6300 • www.kemet.com T2039_T322_AXIAL_T323 • 9/9/2015 3 Tantalum Through-Hole Capacitors – Molded Axial T322 and T323 Series MIL–PRF 49137/1 & 5 (CX01 and CX05 Style) Table 1 – Ratings & Part Number Reference Rated Voltage Rated Cap VDC µF 2 2 2 2 2 2 2 2 2 2 2 2 2 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6.8 8.2 10.0 12.0 15.0 18.0 22.0 27.0 33.0 39.0 47.0 56.0 68.0 4.7 5.6 6.8 8.2 10.0 12.0 15.0 18.0 22.0 27.0 33.0 39.0 47.0 56.0 68.0 3.3 3.9 4.7 4.7 4.7 5.6 5.6 5.6 6.8 6.8 6.8 8.2 8.2 8.2 10.0 10.0 10.0 12.0 12.0 12.0 15.0 15.0 15.0 18.0 22.0 27.0 33.0 33.0 VDC µF Rated Voltage Rated Cap Case Code/ Case Size KEMET Part Number DC Leakage DF A A A B B B B B B C C C C A A A B B B B B B C C C C D D A A A A A B B B B B B B B B B B B B B B B B B C C C C C (See below for part options) T322A685(1)002A(2) T322A825(1)002A(2) T322A106(1)002A(2) T322B126(1)002A(2) T322B156(1)002A(2) T322B186(1)002A(2) T322B226(1)002A(2) T322B276(1)002A(2) T322B336(1)002A(2) T322C396(1)002A(2) T322C476(1)002A(2) T322C566(1)002A(2) T322C686(1)002A(2) T322A475(1)004A(2) T322A565(1)004A(2) T322A685(1)002A(2) T322B825(1)004A(2) T322B106(1)004A(2) T322B126(1)004A(2) T322B156(1)004A(2) T322B186(1)004A(2) T322B226(1)004A(2) T322C276(1)004A(2) T322C336(1)004A(2) T322C396(1)004A(2) T322C476(1)004A(2) T322D566(1)004A(2) T322D686(1)004A(2) T322A335(1)006A(2) T322A395(1)006A(2) T322A475J006A(2) T322A475K006A(2) T322A475M006A(2) T322B565J006A(2) T322B565K006A(2) T322B565M006A(2) T322B685J006A(2) T322B685K006A(2) T322B685M006A(2) T322B825J006A(2) T322B825K006A(2) T322B825M006A(2) T322B106J006A(2) T322B106K006A(2) T322B106M006A(2) T322B126J006A(2) T322B126K006A(2) T322B126M006A(2) T322B156J006A(2) T322B156K006A(2) T322B156M006A(2) T322C186(1)006A(2) T322C226(1)006A(2) T322C276(1)006A(2) T322C336J006A(2) T322C336K006A(2) (see below for part options) µA @ 25°C Max/5 Minimum 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.6 0.8 0.9 1.1 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.6 0.7 0.9 1.1 1.2 1.5 1.8 2.2 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.6 0.6 0.6 0.7 0.7 0.7 0.9 1.1 1.3 1.5 1.5 µA @ 25°C Max/5 Minimum % @ 25°C 120 Hz Maximum 10 10 10 10 10 10 10 10 10 10 10 10 10 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 4 4 4 4 4 4 4 4 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 % @ 25°C 120 Hz Maximum KEMET Part Number DC Leakage DF Case Code/ Case Size CX01 & CX05 Capacitors per MIL–PRF–49137/1 & 5 Military Part Number KEMET Part Number CX05D475K CX05D475M T323A475K006A(2) T323A475M006A(2) CX01D565K CX01D565M T323B565K006A(2) T323B565M006A(2) CX01D685K CX01D685M T323B685K006A(2) T323B685M006A(2) CX01D825K CX01D825M T323B825K006A(2) T323B825M006A(2) CX01D106K CX01D106M T323B106K006A(2) T323B106M006A(2) CX01D126K CX01D126M T323B126K006A(2) T323B126M006A(2) CX05D156K CX05D156M T323B156K006A(2) T323B156M006A(2) CX05D336K T323C336K006A(2) Military Part Number KEMET Part Number CX01 & CX05 Capacitors per MIL–PRF–49137/1 & 5 (1) To complete KEMET part number, insert M for ±20%, K for ±10% or J for 5%. Designates capacitance tolerance. (2) To complete KEMET part number, insert T = 100% Matte Tin (Sn) Plated, S = Standard Solder coated (SnPb 5% Pb minimum). Designates termination finish. © KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 (864) 963-6300 • www.kemet.com T2039_T322_AXIAL_T323 • 9/9/2015 4 Tantalum Through-Hole Capacitors – Molded Axial T322 and T323 Series MIL–PRF 49137/1 & 5 (CX01 and CX05 Style) Table 1 – Ratings & Part Number Reference cont'd Rated Voltage Rated Cap VDC µF 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 15 15 33.0 39.0 47.0 47.0 47.0 56.0 68.0 82.0 100.0 120.0 150.0 180.0 220.0 270.0 330.0 2.2 2.7 3.3 3.3 3.3 3.9 4.7 5.6 6.8 8.2 10.0 10.0 10.0 12.0 15.0 18.0 22.0 22.0 22.0 27.0 27.0 27.0 33.0 33.0 33.0 39.0 39.0 39.0 47.0 47.0 47.0 56.0 68.0 82.0 100.0 120.0 150.0 180.0 220.0 1.5 1.8 VDC µF Rated Voltage Rated Cap Case Code/ Case Size KEMET Part Number DC Leakage DF C D D D D D D E E E E E E F F A A A A A B B B B B B B B C C C C C C D D D D D D D D D D D D E E E E E E F F A A (See below for part options) T322C336M006A(2) T322D396(1)006A(2) T322D476J006A(2) T322D476K006A(2) T322D476M006A(2) T322D566(1)006A(2) T322D686(1)006A(2) T322E826(1)006A(2) T322E107(1)006A(2) T322E127(1)006A(2) T322E157(1)006A(2) T322E187(1)006A(2) T322E227(1)006A(2) T322F277(1)006A(2) T322F337(1)006A(2) T322A225(1)010A(2) T322A275(1)010A(2) T322A335J010A(2) T322A335K010A(2) T322A335M010A(2) T322B395(1)010A(2) T322B475(1)010A(2) T322B565(1)010A(2) T322B685(1)010A(2) T322B825(1)010A(2) T322B106J010A(2) T322B106K010A(2) T322B106M010A(2) T322C126(1)010A(2) T322C156(1)010A(2) T322C186(1)010A(2) T322C226J010A(2) T322C226K010A(2) T322C226M010A(2) T322D276J010A(2) T322D276K010A(2) T322D276M010A(2) T322D336J010A(2) T322D336K010A(2) T322D336M010A(2) T322D396J010A(2) T322D396K010A(2) T322D396M010A(2) T322D476J010A(2) T322D476K010A(2) T322D476M010A(2) T322E566(1)010A(2) T322E686(1)010A(2) T322E826(1)010A(2) T322E107(1)010A(2) T322E127(1)010A(2) T322E157(1)010A(2) T322F187(1)010A(2) T322F227(1)010A(2) T322A155(1)015A(2) T322A185(1)015A(2) (see below for part options) µA @ 25°C Max/5 Minimum 1.5 1.9 2.3 2.3 2.3 2.7 3.3 3.9 4.8 5.0 5.0 8.6 10.0 10.0 10.0 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.7 0.8 0.8 0.8 1.0 1.2 1.4 1.5 1.5 1.5 2.2 2.2 2.2 2.6 2.6 2.6 3.1 3.1 3.1 3.8 3.8 3.8 4.4 5.0 5.0 8.0 9.6 10.0 10.0 10.0 0.5 0.5 µA @ 25°C Max/5 Minimum % @ 25°C 120 Hz Maximum 6 6 6 6 6 6 6 8 8 8 8 8 8 8 8 4 4 4 4 4 4 4 4 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 4 6 6 6 6 6 6 6 6 8 8 8 8 8 8 4 4 % @ 25°C 120 Hz Maximum KEMET Part Number DC Leakage DF Case Code/ Case Size CX01 & CX05 Capacitors per MIL–PRF–49137/1 & 5 Military Part Number KEMET Part Number CX05D336M T323C336M006A(2) CX05D476K CX05D476M T323D476K006A(2) T323D476M006A(2) CX05F335K CX05F335M T323A335K010A(2) T323A335M010A(2) CX05F106K CX05F106M T323B106K010A(2) T323B106M010A(2) CX05F226K CX05F226M T323C226K010A(2) T323C226M010A(2) CX05F276K CX05F276M T323D276K010A(2) T323D276M010A(2) CX05F336K CX05F336M T323D336K010A(2) T323D336M010A(2) CX05F396K CX05F396M T323D396K010A(2) T323D396M010A(2) CX05F476K CX05F476M T323D476K010A(2) T323D476M010A(2) Military Part Number KEMET Part Number CX01 & CX05 Capacitors per MIL–PRF–49137/1 & 5 (1) To complete KEMET part number, insert M for ±20%, K for ±10% or J for 5%. Designates capacitance tolerance. (2) To complete KEMET part number, insert T = 100% Matte Tin (Sn) Plated, S = Standard Solder coated (SnPb 5% Pb minimum). Designates termination finish. © KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 (864) 963-6300 • www.kemet.com T2039_T322_AXIAL_T323 • 9/9/2015 5 Tantalum Through-Hole Capacitors – Molded Axial T322 and T323 Series MIL–PRF 49137/1 & 5 (CX01 and CX05 Style) Table 1 – Ratings & Part Number Reference cont'd Rated Voltage Rated Cap VDC µF 15 15 15 15 15 15 15 15 15 15 15 15 15 15 15 15 15 15 15 15 15 15 15 15 15 15 15 15 15 15 15 15 15 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 2.2 2.2 2.2 2.7 3.3 3.9 4.7 5.6 6.8 6.8 6.8 8.2 10.0 12.0 15.0 15.0 15.0 18.0 22.0 22.0 22.0 27.0 33.0 33.0 33.0 39.0 47.0 56.0 68.0 82.0 100.0 120.0 150.0 1.0 1.2 1.5 1.5 1.5 1.8 2.2 2.7 3.3 3.9 4.7 4.7 4.7 5.6 6.8 8.2 10.0 12.0 12.0 12.0 15.0 15.0 15.0 VDC µF Rated Voltage Rated Cap Case Code/ Case Size KEMET Part Number DC Leakage DF A A A B B B B B B B B C C C C C C D D D D D D D D E E E E E E F F A A A A A B B B B B B B B C C C C D D D D D D (See below for part options) T322A225J015A(2) T322A225K015A(2) T322A225M015A(2) T322B275(1)015A(2) T322B335(1)015A(2) T322B395(1)015A(2) T322B475(1)015A(2) T322B565(1)015A(2) T322B685J015A(2) T322B685K015A(2) T322B685M015A(2) T322C825(1)015A(2) T322C106(1)015A(2) T322C126(1)015A(2) T322C156J015A(2) T322C156K015A(2) T322C156M015A(2) T322D186(1)015A(2) T322D226J015A(2) T322D226K015A(2) T322D226M015A(2) T322D276(1)015A(2) T322D336J015A(2) T322D336K015A(2) T322D336M015A(2) T322E396(1)015A(2) T322E476(1)015A(2) T322E566(1)015A(2) T322E686(1)015A(2) T322E826(1)015A(2) T322E107(1)015A(2) T322F127(1)015A(2) T322F157(1)015A(2) T322A105(1)020A(2) T322A125(1)020A(2) T322A155J020A(2) T322A155K020A(2) T322A155M020A(2) T322B185(1)020A(2) T322B225(1)020A(2) T322B275(1)020A(2) T322B335(1)020A(2) T322B395(1)020A(2) T322B475J020A(2) T322B475K020A(2) T322B475M020A(2) T322C565(1)020A(2) T322C685(1)020A(2) T322C825(1)020A)2) T322C106(1)020A(2) T322D126J020A(2) T322D126K020A(2) T322D126M020A(2) T322D156J020A(2) T322D156K020A(2) T322D156M020A(2) (see below for part options) µA @ 25°C Max/5 Minimum 0.5 0.5 0.5 0.5 0.5 0.5 0.6 0.7 0.8 0.8 0.8 1.0 1.2 1.4 1.5 1.5 1.5 2.2 2.6 2.6 2.6 3.2 4.0 4.0 4.0 4.7 5.0 6.7 8.2 9.8 10.0 10.0 10.0 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.6 0.8 0.8 0.8 0.9 1.1 1.3 1.6 1.9 1.9 1.9 2.4 2.4 2.4 µA @ 25°C Max/5 Minimum % @ 25°C 120 Hz Maximum 4 4 4 4 4 4 4 4 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 8 8 8 8 4 4 4 4 4 4 4 4 4 4 4 4 4 4 6 6 6 6 6 6 6 6 6 % @ 25°C 120 Hz Maximum KEMET Part Number DC Leakage DF Case Code/ Case Size CX01 & CX05 Capacitors per MIL–PRF–49137/1 & 5 Military Part Number KEMET Part Number CX05H225K CX05H225M T323A225K015A(2) T323A225M015A(2) CX05H685K CX05H685M T323B685K015A(2) T323B685M015A(2) CX05H156K CX05H156M T323C156K015A(2) T323C156M015A(2) CX06H226K CX06H226M T323D226K015A(2) T323D226M015A(2) CX05H336K CX05H336M T323D336K015A(2) T323D336M015A(2) CX05J155K CX05J155M T323A155K020A(2) T323A155M020A(2) CX05J475K CX05J475M T323B475K020A(2) T323B475M020A(2) CX05J126K CX05J126M T323D126K020A(2) T323D126M020A(2) CX05J156K CX05J156M T323D156K020A(2) T323D156M020A(2) Military Part Number KEMET Part Number CX01 & CX05 Capacitors per MIL–PRF–49137/1 & 5 (1) To complete KEMET part number, insert M for ±20%, K for ±10% or J for 5%. Designates capacitance tolerance. (2) To complete KEMET part number, insert T = 100% Matte Tin (Sn) Plated, S = Standard Solder coated (SnPb 5% Pb minimum). Designates termination finish. © KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 (864) 963-6300 • www.kemet.com T2039_T322_AXIAL_T323 • 9/9/2015 6 Tantalum Through-Hole Capacitors – Molded Axial T322 and T323 Series MIL–PRF 49137/1 & 5 (CX01 and CX05 Style) Table 1 – Ratings & Part Number Reference cont'd Rated Voltage Rated Cap VDC µF 20 20 20 20 20 20 20 20 20 20 25 25 25 25 25 25 25 25 25 25 25 25 25 25 25 25 25 25 25 25 25 25 25 25 25 25 25 25 25 25 25 25 25 25 25 25 25 25 25 25 25 35 35 35 35 35 18.0 22.0 27.0 33.0 39.0 47.0 56.0 68.0 82.0 100.0 0.47 0.56 0.68 0.82 1.0 1.0 1.0 1.2 1.5 1.5 1.5 1.8 1.8 1.8 2.2 2.2 2.2 2.7 3.3 3.3 3.3 3.9 4.7 5.6 6.8 6.8 6.8 8.2 10.0 10.0 10.0 12.0 15.0 18.0 22.0 27.0 33.0 39.0 47.0 56.0 68.0 0.1 0.12 0.15 0.18 0.22 VDC µF Rated Voltage Rated Cap Case Code/ Case Size KEMET Part Number DC Leakage DF D D E E E E E E F F A A A A A A A B B B B B B B B B B B B B B C C C C C C C C C C D D E E E E E E F F A A A A A (See below for part options) T322D186(1)020A(2) T322D226(1)020A(2) T322E276(1)20A(2) T322E336(1)020A(2) T322E396(1)020A(2) T322E476(1)20A(2) T322E566(1)020A(2) T322E686(1)020A(2) T322F826(1)020A(2) T322F107(1)020A(2) T322A474(1)025A(2) T322A564(1)025A(2) T322A684(1)025A(2) T322A824(1)025A(2) T322A105J025A(2) T322A105K025A(2) T322A105M025A(2) T322B125(1)025A(2) T322B155J025A(2) T322B155K025A(2) T322B155M025A(2) T322B185J025A(2) T322B185K025A(2) T322B185M025A(2) T322B225J025A(2) T322B225K025A(2) T322B225M025A(2) T322B275(1)025A(2) T322B335J025A(2) T322B335K025A(2) T322B335M025A(2) T322C395(1)025A(2) T322C475(1)025A(2) T322C565(1)025A(2) T322C685J025A(2) T322C685K025A(2) T322C685M025A(2) T322C825(1)025A)2) T322C106J025A(2) T322C106K025A(2) T322C106M025A(2) T322D126(1)025A(2) T322D156(1)025A(2) T322E186(1)025A(2) T322E226(1)025A(2) T322E276(1)025A(2) T322E336(1)025A(2) T322E396(1)025A(2) T322E476(1)025A(2) T322F566(1)025A(2) T322F686(1)025A(2) T322A104(10035A(2) T322A124(1)035A(2) T322A154(1)035A(2) T322A184(1)035A(2) T322A224(1)035A(2) (see below for part options) µA @ 25°C Max/5 Minimum 2.9 3.5 4.3 5.0 6.2 7.5 8.9 10.0 10.0 10.0 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.7 0.7 0.7 0.8 0.9 1.1 1.4 1.4 1.4 1.4 1.5 1.5 1.5 2.4 3.0 3.6 4.4 5.4 6.6 7.9 9.4 10.0 10.0 0.5 0.5 0.5 0.5 0.5 µA @ 25°C Max/5 Minimum % @ 25°C 120 Hz Maximum 6 6 6 6 6 6 6 6 8 8 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 4 4 4 4 4 4 4 4 4 4 4 6 6 6 6 6 6 6 6 3 3 3 3 3 % @ 25°C 120 Hz Maximum KEMET Part Number DC Leakage DF Case Code/ Case Size CX01 & CX05 Capacitors per MIL–PRF–49137/1 & 5 Military Part Number KEMET Part Number CX05K105K CX05K105M T323A105K025A(2) T323A105M025A(2) CX05K155K CX05K155M T323B155K025A(2) T323B155M025A(2) CX05K185K CX05K185M T323B185K025A(2) T323B185M025A(2) CK05K225K CK05K225M T323B225K025A(2) T323B225M025A(2) CX05K335K CX05K335M T323B335K025A(2) T323B335M025A(2) CX05K685K CX05K685M T323C685K025A(2) T323C685M025A(2) CX05K106K CX05K106M T323C106K025A(2) T323C106M025A(2) Military Part Number KEMET Part Number CX01 & CX05 Capacitors per MIL–PRF–49137/1 & 5 (1) To complete KEMET part number, insert M for ±20%, K for ±10% or J for 5%. Designates capacitance tolerance. (2) To complete KEMET part number, insert T = 100% Matte Tin (Sn) Plated, S = Standard Solder coated (SnPb 5% Pb minimum). Designates termination finish. © KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 (864) 963-6300 • www.kemet.com T2039_T322_AXIAL_T323 • 9/9/2015 7 Tantalum Through-Hole Capacitors – Molded Axial T322 and T323 Series MIL–PRF 49137/1 & 5 (CX01 and CX05 Style) Table 1 – Ratings & Part Number Reference cont'd Rated Voltage Rated Cap VDC µF 35 35 35 35 35 35 35 35 35 35 35 35 35 35 35 35 35 35 35 35 35 35 35 35 35 35 35 35 35 35 35 35 35 35 35 35 35 35 35 35 35 35 35 35 35 35 35 35 35 35 35 35 35 35 50 50 0.27 0.33 0.33 0.33 0.39 0.47 0.47 0.47 0.56 0.56 0.56 0.68 0.68 0.68 0.82 0.82 0.82 1.0 1.0 1.0 1.2 1.2 1.2 1.5 1.5 1.5 1.8 2.2 2.7 3.3 3.3 3.3 3.9 3.9 3.9 4.7 4.7 4.7 5.6 6.8 6.8 6.8 8.2 10.0 10.0 10.0 12.0 15.0 18.0 22.0 27.0 33.0 39.0 47.0 0.1 0.1 VDC µF Rated Voltage Rated Cap Case Code/ Case Size KEMET Part Number DC Leakage DF A A A A A A A A B B B B B B B B B B B B B B B B B B C C C C C C C C C C C C D D D D D D D D E E E E E E F F A A (See below for part options) T322A274(1)035A(2) T322A334J035A(2) T322A334K035A(2) T322A334M035A(2) T322A394(1)035A(2) T322A474J035A(2) T322A474K035A(2) T322A474M035A(2) T322B564J035A(2) T322B564K035A(2) T322B564M035A(2) T322B684J035A(2) T322B684K035A(2) T322B684M035A(2) T322B824J035A(2) T322B824K035A(2) T322B824M035A(2) T322B105J035A(2) T322B105K035A(2) T322B105K035A(2) T322B125J035A(2) T322B125K035A(2) T322B125M035A(2) T322B155J035A(2) T322B155K035A(2) T322B155M035A(2) T322C185(1)035A(2) T322C225(1)035A(2) T322C275(1)035A(2) T322C335J035A(2) T322C335K035A(2) T322C335M035A(2) T322C395J035A(2) T322C395K035A(2) T322C395M035A(2) T322C475J035A(2) T322C475K035A(2) T322C475M035A(2) T322C565M035A(2) T322D685J035A(2) T322D685K035A(2) T322D685M035A(2) T322D825(1)035A(2) T322D106J035A(2) T322D106K035A(2) T322D106M035A(2) T322E126(1)035A(2) T322E156(1)035A(2) T322E186(1)035A(2) T322E226(1)035A(2) T322E276(1)035A(2) T322E336(1)035A(2) T322F396(1)035A(2) T322F476(1)035A(2) T322A104J050A(2) T322A104K050A(2) (see below for part options) µA @ 25°C Max/5 Minimum 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.6 0.8 0.9 0.9 0.9 1.1 1.1 1.1 1.3 1.3 1.3 1.6 1.9 1.9 1.9 2.3 2.8 2.8 2.8 3.3 4.2 5.0 6.2 7.5 9.2 10.0 10.0 0.5 0.5 µA @ 25°C Max/5 Minimum % @ 25°C 120 Hz Maximum 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 6 6 6 6 6 6 6 3 3 % @ 25°C 120 Hz Maximum KEMET Part Number DC Leakage DF Case Code/ Case Size CX01 & CX05 Capacitors per MIL–PRF–49137/1 & 5 Military Part Number KEMET Part Number CX05M334K CX05M334M T323A334K035A(2) T323A334M035A(2) CX05M474K CX05M474K T323A474K035A(2) T323A474K035A(2) CX01M564K CX01M564M T323B564K035A(2) T323B564M035A(2) CX01M684K CX01M684M T322B684K035A(2) T322B684M035A(2) CX01M824K CX01M824M T323B824K035A(2) T323B824M035A(2) CX01M105K CX01M105M T323B105K035A(2) T323B105M035A(2) CX01M125K CX01M125M T323B125K035A(2) T323B125M035A(2) CX05M155K CX05M155M T323B155K035A(2) T323B155M035A(2) CX05M335K CX05M335M T323C335K035A(2) T323C335M035A(2) CX05M395K CX05M395M T323C395K035A(2) T323C395M035A(2) CX05M475K CX05M475M T323C475K035A(2) T322C475M035A(2) CX05M685K CX05M685M T323D685K035A(2) T323D685M035A(2) CX05M106K CX05M106M T323D106K035A(2) T323D106M035A(2) CX05N104K T323A104K050A(2) Military Part Number KEMET Part Number CX01 & CX05 Capacitors per MIL–PRF–49137/1 & 5 (1) To complete KEMET part number, insert M for ±20%, K for ±10% or J for 5%. Designates capacitance tolerance. (2) To complete KEMET part number, insert T = 100% Matte Tin (Sn) Plated, S = Standard Solder coated (SnPb 5% Pb minimum). Designates termination finish. © KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 (864) 963-6300 • www.kemet.com T2039_T322_AXIAL_T323 • 9/9/2015 8 Tantalum Through-Hole Capacitors – Molded Axial T322 and T323 Series MIL–PRF 49137/1 & 5 (CX01 and CX05 Style) Table 1 – Ratings & Part Number Reference cont'd Rated Voltage Rated Cap VDC µF 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 0.1 0.12 0.15 0.15 0.15 0.18 0.22 0.22 0.22 0.27 0.33 0.33 0.33 0.39 0.39 0.39 0.47 0.47 0.47 0.56 0.68 0.68 0.68 0.82 1.0 1.0 1.0 1.2 1.5 1.5 1.5 1.8 2.2 2.2 2.2 2.7 3.3 3.3 3.3 3.9 4.7 4.7 4.7 5.6 6.8 8.2 10.0 12.0 15.0 18.0 22.0 VDC µF Rated Voltage Rated Cap Case Code/ Case Size KEMET Part Number DC Leakage DF A A A A A A A A A A B B B B B B B B B B B B B B B B B C C C C C C C C D D D D D D D D E E E E F F F F (See below for part options) T322A104M050A(2) T322A124(1)050A(2) T322A154J050A(2) T322A154K050A(2) T322A154M050A(2) T322A184(1)050A(2) T322A224J050A(2) T322A224K050A(2) T322A224M050A(2) T322A274(1)050A(2) T322B334J050A(2) T322B334K050A(2) T322B334M050A(2) T322B394J050(2) T322B394K050A(2) T322B394M050A(2) T322B474J050A(2) T322B474K050A(2) T322B474M050A(2) T322B564(1)050A(2) T322B684J050A(2) T322B684K050A(2) T322B684M050A(2) T322B824(1)050A(2) T322B105J050A(2) T322B105K050A(2) T322B105M050A(2) T322C125(1)050A(2) T322C155J050A(2) T322C155K050A(2) T322C155M050A(2) T322C185(1)050A(2) T322C225J050A(2) T322C225K050A(2) T322C225M050A(2) T322D275(1)050A(2) T322D335J050A(2) T322D335K050A(2) T322D335M050A(2) T322D395(1)050A(2) T322D475J050A(2) T322D475K050A(2) T322D475M050A(2) T322E565(1)050A(2) T322E685(1)050A(2) T322E825(1)050A(2) T322E106(1)050A(2) T322F126(1)050A(2) T322F156(1)050A(2) T322F186(1)050A(2) T322F226(1)050A(2) (see below for part options) µA @ 25°C Max/5 Minimum 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.6 0.6 0.6 0.7 0.9 0.9 0.9 1.1 1.3 1.3 1.3 1.6 1.9 1.9 1.9 2.2 2.7 3.2 4.0 4.8 6.0 7.2 8.8 µA @ 25°C Max/5 Minimum % @ 25°C 120 Hz Maximum 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 6 6 6 6 6 % @ 25°C 120 Hz Maximum KEMET Part Number DC Leakage DF Case Code/ Case Size CX01 & CX05 Capacitors per MIL–PRF–49137/1 & 5 Military Part Number KEMET Part Number CX05N104M T323A104M050A(2) CX05N154K CX05N154M T323A154K050A(2) T323A154M050A(2) CX05N224K CX05N224M T323A224K050A(2) T323A224M050A(2) CX05N334K CX05N334M T323B334K050A(2) T323B334M050A(2) CX05N394K CX05N394M T323B394K050A(2) T323B394M050A(2) CX05N474K CX05N474M T323B474K050A(2) T323B474M050A(2) CX05N684K CX05N684M T323B684K050A(2) T323B684M050A(2) CX05N105K CX05N105M T323B105K050A(2) T323B105M050A(2) CX05N155K CX05N155M T323C155K050A(2) T323C155M050A(2) CX05N225K CX05N225M T323C225K050A(2) T323C225M050A(2) CX05N335K CX05N335M T323D335K050A(2) T323D335M050A(2) CX05N475K CX05N475M T323D475K050A(2) T323D475M050A(2) Military Part Number KEMET Part Number CX01 & CX05 Capacitors per MIL–PRF–49137/1 & 5 (1) To complete KEMET part number, insert M for ±20%, K for ±10% or J for 5%. Designates capacitance tolerance. (2) To complete KEMET part number, insert T = 100% Matte Tin (Sn) Plated, S = Standard Solder coated (SnPb 5% Pb minimum). Designates termination finish. © KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 (864) 963-6300 • www.kemet.com T2039_T322_AXIAL_T323 • 9/9/2015 9 Tantalum Through-Hole Capacitors – Molded Axial T322 and T323 Series MIL–PRF 49137/1 & 5 (CX01 and CX05 Style) Recommended Voltage Derating Guidelines 85°C to 125°C VR 66% of VR 120% 100% % Working Voltage % Change in Working DC Voltage with Temperature -55°C to 85°C 80% % Change in Working DC Voltage with Temperature 60% 67% 40% 20% 0% -55 25 45 85 Temperature (°C) 105 125 Ripple Current/Ripple Voltage Permissible AC ripple voltage and current are related to equivalent series resistance (ESR) and the power dissipation capabilities of the device. Permissible AC ripple voltage that may be applied is limited by following criteria: 1. Dissipated power must not exceed the limits specified for the Series. 2. The positive peak AC voltage plus the DC bias voltage, if any, must not exceed the DC voltage rating of the capacitor. 3. The negative peak AC voltage in combination with bias voltage, if any, must not exceed the allowable limits specified for reverse voltage. Thermal capacities for the various case sizes have been determined empirically and are listed below. The “ripple voltage” permissible may be calculated from the impedance and ESR data shown in the respective product section. Temperature Compensation Multipliers for Maximum Power Dissipation T ≤ 25°C 1.00 T ≤ 85°C 0.90 T ≤ 125°C 0.40 T= Environmental Temperature Maximum allowable rms ripple voltage or current may be determined as follows: I(max) = √P max/R E(max) = √P max/R I = rms ripple current (amperes) E = rms ripple voltage (volts) P max = Maximum power dissipation (watts) R = ESR at specified frequency (ohms) Case Size Maximum Power Dissipation (Pmax) Watts @ 25°C A B C D E F 0.060 0.070 0.080 0.090 0.100 0.110 © KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 (864) 963-6300 • www.kemet.com T2039_T322_AXIAL_T323 • 9/9/2015 10 Tantalum Through-Hole Capacitors – Molded Axial T322 and T323 Series MIL–PRF 49137/1 & 5 (CX01 and CX05 Style) Optimum Solder Wave Profile Capacitor Marking 105 M + 25 K 1535 Capacitance Code, Tolerance Polarity, Voltage & KEMET trademark DateCode (YY/WW) © KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 (864) 963-6300 • www.kemet.com T2039_T322_AXIAL_T323 • 9/9/2015 11 Tantalum Through-Hole Capacitors – Molded Axial T322 and T323 Series MIL–PRF 49137/1 & 5 (CX01 and CX05 Style) Storage Tantalum hermetically sealed capacitors should be stored in normal working environments. While the capacitors themselves are quite robust in other environments, solderability will be degraded by exposure to high temperatures, high humidity, corrosive atmospheres, and long term storage. In addition, packaging materials will be degraded by high temperature– reels may soften or warp and tape peel force may increase. KEMET recommends that maximum storage temperature not exceed 40ºC and maximum storage humidity not exceed 60% relative humidity. Temperature fluctuations should be minimized to avoid condensation on the parts and atmospheres should be free of chlorine and sulphur bearing compounds. For optimized solderability capacitors stock should be used promptly, preferably within three years of receipt. Tape & Reel Packaging Information KEMET offers standard reeling of Solid Tantalum Capacitors for automatic insertion or lead forming machines per EIA Specification RS-296E. Table 2 – Packaging Quantity Case Size Standard Bulk Standard Reel Reel C-Spec Quantity Quantity Ammo Pack Quantity Ammo Pack C-Spec A 300 4500 2000 C-7293 B 250 4000 2000 Class I C 100 2500 1000 C-7442 D 100 2500 1000 Class II E 100 500 250 C-7443 F 100 500 250 Class III C-7200 © KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 (864) 963-6300 • www.kemet.com T2039_T322_AXIAL_T323 • 9/9/2015 12 Tantalum Through-Hole Capacitors – Molded Axial T322 and T323 Series MIL–PRF 49137/1 & 5 (CX01 and CX05 Style) Figure 2 Figure 3 12" (30.48cm) * 0.059" to 0.315" Greater Than Component Length White (+) (Anode) Blue ( –) (Cathode) 0.047" Maximum (1.20) Hub 0.655" ±0.010 Hole (15.9 ±0.25) * 3 1 /4 " (82.6) 1/ " 8 (3.18) See Table 3 "B" See Table 3 "A" 0.250" Nominal (6.35) Table 3 – Tape Dimensions Component Body Diameter Component Pitch "A" Inside Tape Spacing "B" ±1.5 mm (0.059") 0.020" or (±0.5 mm) I II III 0" (0 mm) to 0.197" (5 mm) 0.200" or (5 mm) 2.062" 2.500" 2.874" 0.197" (5.01 mm) to 0.394" (10 mm) 0.400 or (10 mm) (52.4 mm) (63.5 mm) (73 mm) Capacitors are reeled so that positive leads are oriented as shown in Figure 3. Kraft paper (50lb. test minimum) is inserted between the layers of capacitors wound on reels for component pitch ≤ 0.200" sizes and corrugated paper (70 lb. test minimum), single faced is inserted for component pitch ≥ 0.400" sizes. Capacitor lead length may extend only a maximum of .031" (0.8 mm) beyond the tape’s edges. Capacitors are centered in a row between the two tapes and will deviate only ±0.031" (0.79 mm) from the row center. Figures 1 and 2 show the KEMET standard chipboard tape reel. A minimum of 36" (91.5 cm) leader tape is provided at each end of the reeled capacitors. Universal splicing clips are used to connect the tape. © KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 (864) 963-6300 • www.kemet.com T2039_T322_AXIAL_T323 • 9/9/2015 13 Tantalum Through-Hole Capacitors – Molded Axial T322 and T323 Series MIL–PRF 49137/1 & 5 (CX01 and CX05 Style) KEMET Corporation World Headquarters Europe Asia Southern Europe Sasso Marconi, Italy Tel: 39-051-939111 Northeast Asia Hong Kong Tel: 852-2305-1168 Mailing Address: P.O. Box 5928 Greenville, SC 29606 Skopje, Macedonia Tel: 389-2-55-14-623 Shenzhen, China Tel: 86-755-2518-1306 www.kemet.com Tel: 864-963-6300 Fax: 864-963-6521 Central Europe Landsberg, Germany Tel: 49-8191-3350800 Corporate Offices Fort Lauderdale, FL Tel: 954-766-2800 Kamen, Germany Tel: 49-2307-438110 North America Northern Europe Wyboston, United Kingdom Tel: 44-1480-273082 Taipei, Taiwan Tel: 886-2-27528585 Espoo, Finland Tel: 358-9-5406-5000 Southeast Asia Singapore Tel: 65-6701-8033 2835 KEMET Way Simpsonville, SC 29681 Northeast Wilmington, MA Tel: 978-658-1663 Southeast Lake Mary, FL Tel: 407-855-8886 Central Novi, MI Tel: 248-994-1030 Beijing, China Tel: 86-10-5877-1075 Shanghai, China Tel: 86-21-6447-0707 Seoul, South Korea Tel: 82-2-6294-0550 Penang, Malaysia Tel: 60-4-6430200 Bangalore, India Tel: 91-806-53-76817 Irving, TX Tel: 972-915-6041 West Milpitas, CA Tel: 408-433-9950 Mexico Guadalajara, Jalisco Tel: 52-33-3123-2141 Note: KEMET reserves the right to modify minor details of internal and external construction at any time in the interest of product improvement. KEMET does not assume any responsibility for infringement that might result from the use of KEMET Capacitors in potential circuit designs. KEMET is a registered trademark of KEMET Electronics Corporation. © KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 (864) 963-6300 • www.kemet.com T2039_T322_AXIAL_T323 • 9/9/2015 14 Tantalum Through-Hole Capacitors – Molded Axial T322 and T323 Series MIL–PRF 49137/1 & 5 (CX01 and CX05 Style) Disclaimer All product specifications, statements, information and data (collectively, the “Information”) in this datasheet are subject to change. The customer is responsible for checking and verifying the extent to which the Information contained in this publication is applicable to an order at the time the order is placed. All Information given herein is believed to be accurate and reliable, but it is presented without guarantee, warranty, or responsibility of any kind, expressed or implied. Statements of suitability for certain applications are based on KEMET Electronics Corporation’s (“KEMET”) knowledge of typical operating conditions for such applications, but are not intended to constitute – and KEMET specifically disclaims – any warranty concerning suitability for a specific customer application or use. The Information is intended for use only by customers who have the requisite experience and capability to determine the correct products for their application. Any technical advice inferred from this Information or otherwise provided by KEMET with reference to the use of KEMET’s products is given gratis, and KEMET assumes no obligation or liability for the advice given or results obtained. Although KEMET designs and manufactures its products to the most stringent quality and safety standards, given the current state of the art, isolated component failures may still occur. Accordingly, customer applications which require a high degree of reliability or safety should employ suitable designs or other safeguards (such as installation of protective circuitry or redundancies) in order to ensure that the failure of an electrical component does not result in a risk of personal injury or property damage. Although all product–related warnings, cautions and notes must be observed, the customer should not assume that all safety measures are indicted or that other measures may not be required. © KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 (864) 963-6300 • www.kemet.com T2039_T322_AXIAL_T323 • 9/9/2015 15