Lumileds LXK2-PB14-Q00 The most robust and powerful led Datasheet

Technical Datasheet DS51
power light source
LUXEON K2
®
Introduction
LUXEON® K2 is the most robust and powerful LED available. With
unprecedented thermal, drive current and light output capabilities, it offers
the lighting industry leading lumens per package and the opportunity to
create never before possible lighting solutions. LUXEON K2 is available in
all colors including coolwhite, neutralwhite, warmwhite, blue, royal blue,
green, cyan, redorange, red and amber.
Œ
deliver more useable light
Œ
optimize applications to reduce size and cost
Œ
engineer more robust applications
Œ
reduce thermal management engineering
Œ
utilize standard FR4 PCB technology in addition to MCPCB solutions
Œ
simplify manufacturing through the use of surface mount technology.
LUXEON K2
Technology
Leadership
Œ Highest operating junction
temperature available, 185°C
Œ Industry leading lumen perform
ance, > 140—175 lumens in
6500K white
Œ Highest Drive Currents—1500 mA
Œ Lowest Thermal Resistance—
9°C/W
Œ Industry Best Moisture Sensitivity
level—JEDEC 2a
4 week floor life without recondi
tioning
Œ Lead free reflow solder
JEDEC 020c compatible
Œ RoHS Compliant
Œ Autoclave compliant—
JESD22 A102
Œ Industry Best Lumen
Maintenance—50,000 hours life
at 1000 mA with 70% lumen
maintenance
Table of Contents
Product Nomenclature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
Average Lumen Maintenance Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
Environmental Compliance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
Flux Characteristics for LUXEON K2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
Flux Characteristics for LUXEON K2 Star . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
Optical Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
Electrical Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
Absolute Maximum Ratings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11
JEDEC Moisture Sensitivity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12
Reflow Soldering Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12
Mechanical Dimensions—SMT 4-Lead Gullwing Form . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13
Solder Pad Layout—SMT Lead Form . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14
Mechanical Dimensions—2-Lead Gullwing Form . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15
Solder Pad Design—2-Lead Gullwing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16
Solder Pad Layout—2-Lead Gullwing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16
Pin Out Diagram—Gullwing Form . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16
Mechanical Dimensions—LUXEON K2 Star . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .17
Wavelength Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18
Typical Light Output Characteristics Over Temperature . . . . . . . . . . . . . . . . . . . . . . . . . . . . .20
Typical Forward Current Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .23
Typical Relative Luminous Flux . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .24
Current Derating Curves . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .26
Typical Radiation Patterns . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .30
Emitter Reel Packaging . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .33
White Binning Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .34
LUXEON K2 Cool-White Bin Structure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .35
LUXEON K2 Neutral-White Bin Structure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .37
LUXEON K2 Warm-White Bin Structure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .39
LUXEON K2 Datasheet DS51 (7/07)
2
Product Nomenclature
The LUXEON K2 is available in two configurations, one tested and binned at 350 mA and a second tested and binned at 1000
mA. Due to production distribution and variance it is difficult to accurately correlate product performance across a broad drive
current range. This is one of the reasons Philips Lumileds has elected to offer multiple test current options of the LUXEON K2 to
better service our customers.
The part number designation is explained as follows:
L X K 2 A B C D E F G for LUXEON K2 Emitter
L 2 K 2 A B C D E F G H for LUXEON K2 Star
Where:
A — designates radiation pattern (value P for Lambertian)
B — designates color (see Philips Lumileds AB21)
C — designates color variant (1 for direct colors and CoolWhite, N for NeutralWhite, and W for WarmWhite
D — designates test current (value 2 for 350 mA, value 4 for 1000 mA)
E — designates minimum flux bin for LUXEON K2 Emitter (see Philips Lumileds AB21)
F — designates minimum flux bin for LUXEON K2 Star product (see Philips Lumileds AB21), Reserved for future product offer
ings in LUXEON K2 Emitter
G and H — Reserved for future product offerings.
Products tested and binned at 350 mA follow the part numbering scheme:
L X K 2 x x x 2 x x x (L2K2 xxx2 11 Bxxx for LUXEON K2 Star)
For these products typical performance is also listed for 700 mA operation.
Products tested and binned at 1000 mA follow the part numbering scheme:
L X K 2 x x x 4 x x x (L2K2 xxx4 11 Bxxx for LUNXEON K2 Star)
For these products typical performance is also listed for 1500 mA operation.
Both versions of this product are capable of operation over the entire drive current range, up to 1500 mA for coolwhite,
neutral white, warmwhite, green, cyan, blue and royal blue and up to 700 mA for red, redorange and amber.
In addition, multiple minimum performance levels of both products are available. Digit "E" (Digit "F" for K2 Star Product) in the
partnumbering scheme above, specifying the minimum performance flux bin, designates the performance option.
Average Lumen Maintenance Characteristics
Lifetime for solidstate lighting devices (LEDs) is typically defined in terms of lumen maintenance—the percentage of initial light
output remaining after a specified period of time.
Philips Lumileds projects that white LUXEON K2 products will deliver, on average, 70% lumen maintenance at 50,000 hours of
operation at a forward current of 1000 mA. This projection is based on constant current operation with junction temperature
maintained at or below 120°C. Philips Lumileds projects that green, blue, cyan and royal blue LUXEON K2 products will deliver,
on average, 70% lumen maintenance at 50,000 hours of operation at a forward current of 1000 mA. This projection is based on
constant current operation with junction temperature maintained at or below 150°C. Philips Lumileds projects that red, red
orange and amber LUXEON K2 products will deliver, on average, 70% lumen maintenance at 50,000 hours of operation at a
forward current of 350 mA. This projection is based on constant current operation with junction temperature maintained at or
below 120°C.
This performance is based on independent test data, Philips Lumileds historical data from tests run on similar material systems,
and internal LUXEON reliability testing. Observation of design limits included in this data sheet is required in order to achieve this
projected lumen maintenance.
LUXEON K2 Datasheet DS51 (7/07)
3
Environmental Compliance
Philips Lumileds is committed to providing environmentally friendly products to the solidstate lighting market. The LUXEON K2
is compliant to the European Union directives on the Restriction of Hazardous Substances in electronic equipment, namely the
RoHS directive. Philips Lumileds will not intentionally add the following restricted materials to the LUXEON K2: lead, mercury,
cadmium, hexavalent chromium, polybrominated biphenyls (PBB) or polybrominated diphenyl ethers (PBDE).
LUXEON K2 Datasheet DS51 (7/07)
4
Flux Characteristics for LUXEON K2
Junction Temperature, TJ = 25°C
Table 1.
Performance at Test Currents
Typical Performance
at Indicated Current
Color
Part Number
Minimum Luminous
Flux (lm) or
Radiometric
Power (mW)
ΦV [1] [3]
CoolWhite
LXK2PW12R00
LXK2PW12S00
LXK2PW14T00
LXK2PW14U00
LXK2PW14V00
39.8
51.7
80
87.4
113.6
45
60
85
100
120
350
350
1000
1000
1000
75
100
110
130
140
700
700
1500
1500
1500
Neutral
White
LXK2PWN2Q00
LXK2PWN2R00
LXK2PWN2S00
LXK2PWN4T00
LXK2PWN4U00
LXK2PWN4V00
30.6
39.8
51.7
67.2
87.4
113.6
35
45
60
80
100
120
350
350
350
1000
1000
1000
60
75
100
105
130
140
700
700
700
1500
1500
1500
Warm
White
LXK2PWW2Q00
LXK2PWW2R00
LXK2PWW4T00
LXK2PWW4U00
30.6
39.8
67.2
87.4
35
45
80
100
350
350
1000
1000
60
75
105
130
700
700
1500
1500
Green
LXK2PM12R00
LXK2PM12S00
LXK2PM14U00
39.8
51.7
87.4
45
60
100
350
350
1000
75
100
130
700
700
1500
Cyan
LXK2PE12Q00
LXK2PE12R00
LXK2PE12S00
LXK2PE14T00
LXK2PE14U00
30.6
39.8
51.7
67.2
87.4
35
45
60
80
100
350
350
350
1000
1000
60
75
100
105
130
700
700
700
1500
1500
Blue
LXK2PB12K00
LXK2PB12L00
LXK2PB12M00
LXK2PB14N00
LXK2PB14P00
LXK2PB14Q00
8.2
10.7
13.9
18.1
23.5
30.6
9.5
12.5
16
21
27
35
350
350
350
1000
1000
1000
16
21
27
35
35
46
700
700
700
1500
1500
1500
Royal Blue
LXK2PR12L00
LXK2PR12M00
LXK2PR14Q00
LXK2PR14R00
LUXEON K2 Datasheet DS51 (7/07)
175
225
435
515
mW
mW
mW
mW
Typical Luminous
Flux (lm) or
Radiometric
Power (mW)
ΦV [2] [3]
Test
Current
(mA)
200
290
475
575
mW
mW
mW
mW
5
350
350
1000
1000
Typical Luminous
Flux (lm) or
Radiometric
Power (mW)
ΦV [2] [3]
330
480
620
750
mW
mW
mW
mW
Drive
Current
(mA)
700
700
1500
1500
Flux Characteristics for LUXEON K2, Continued
Junction Temperature, TJ = 25°C
Table 1 Continued .
Performance at Test Currents
Typical Performance
at Indicated Current
Color
Part Number
Minimum Luminous
Flux (lm) or
Radiometric
Power (mW)
ΦV [1] [3]
Typical Luminous
Flux (lm) or
Radiometric
Power (mW)
ΦV [2] [3]
Test
Current
(mA)
Typical Luminous
Flux (lm) or
Radiometric
Power (mW)
ΦV [2] [3]
Red
LXK2PD12Q00
LXK2PD12R00
LXK2PD12S00
30.6
39.8
51.7
35
45
60
350
350
350
60
75
100
700
700
700
Red
Orange
LXK2PH12R00
LXK2PH12S00
39.8
51.7
45
60
350
350
75
100
700
700
Amber
LXK2PL12P00
LXK2PL12Q00
LXK2PL12R00
23.5
30.6
39.8
27
35
45
350
350
350
46
60
75
700
700
700
Drive
Current
(mA)
Flux Characteristics for LUXEON K2 Star,
Junction Temperature, TJ = 25°C
Table 2.
Performance at Test Currents
Typical Performance
at Indicated Current
Color
Flux Bin
Minimum Luminous
Flux (lm) or
Radiometric
Power (mW)
ΦV [1] [3]
Typical Luminous
Flux (lm) or
Radiometric
Power (mW)
ΦV [2] [3]
Test
Current
(mA)
Typical Luminous
Flux (lm) or
Radiometric
Power (mW)
ΦV [2] [3]
Drive
Current
(mA)
CoolWhite
L2K2MW1211BR00
L2K2MW1211BS00
L2K2MW1411BT00
L2K2MW1411BU00
L2K2MW1411BV00
39.8
51.7
80
87.4
113.6
45
60
85
100
120
350
350
1000
1000
1000
75
100
110
130
140
700
700
1500
1500
1500
Neutral
White
L2K2MWN211BQ00
L2K2MWN211BR00
L2K2MWN211BS00
L2K2MWN411BT00
L2K2MWN411BU00
L2K2MWN411BV00
30.6
39.8
51.7
67.2
87.4
113.6
35
45
60
80
100
120
350
350
350
1000
1000
1000
60
75
100
105
130
140
700
700
700
1500
1500
1500
Warm
White
L2K2MWW211BQ00
L2K2MWW211BR00
L2K2MWW411BT00
L2K2MWW411BU00
30.6
39.8
67.2
87.4
35
45
80
100
350
350
1000
1000
60
75
105
130
700
700
1500
1500
Notes for Table 1 and Table 2:
1. Minimum luminous flux or radiometric power performance guaranteed within published operating conditions.
Philips Lumileds maintains a tolerance of ± 10% on flux and power measurements.
2. Typical luminous flux or radiometric power performance when device is operated within published operating conditions.
3. LUXEON K2 products with even higher luminous flux and radiometric power levels will become available in the future.
Please consult Philips Lumileds or Future Electronics for more information.
4. Radiation Pattern for all LUXEON K2 Star products is Lambertian.
LUXEON K2 Datasheet DS51 (7/07)
6
Optical Characteristics
LUXEON K2 at Test Current[1]
Junction Temperature, TJ = 25°C
Table 3.
Color
Cool White
Dominant Wavelength [2] λD,
Peak Wavelength [3] λP,
or Color Temperature [4]
CCT
Min.
Typ.
Max.
4500 K
6500 K
Typical
Spectral
Halfwidth
(nm)
Δλ1/2
10000 K
[6]
Typical
Temperature
Coefficient of
Dominant
Wavelength
(nm/oC)
ΔλD/ ΔTJ
Typical
Total
Included
Angle [7]
(degrees)
θ0.90V
Typical
Viewing
Angle [8]
(degrees)
2θ 1/2
160
140
Neutral White
3500K
4100K
4500K
160
140
Warm White
2650K
3000K
3500K
160
140
Green
520 nm
530 nm
550 nm
35
0.04
160
140
Cyan
490 nm
505 nm
520 nm
30
0.04
160
140
Blue
460 nm
470 nm
490 nm
25
0.04
160
140
Royal Blue[3]
440 nm
455 nm
460 nm
20
0.04
160
140
Red
620.5 nm
627 nm
645 nm
20
0.05
160
140
RedOrange
613.5 nm
617 nm
620.5 nm
20
0.06
160
140
Amber
584.5 nm
590 nm
597 nm
14
0.09
160
140
Notes for Table 3:
1.
Test current is 350 mA for all LXK2 xxx2 xxx (L2K2 xxx2 11 xxxx for K2 Star) products, and 1000 mA for all
LXK2 xxx4 xxx products (L2K2 xxx4 11 xxxx for K2 Star).
2. Dominant wavelength is derived from the CIE 1931 Chromaticity diagram and represents the perceived color. Philips
Lumileds maintains a tolerance of ± 0.5 nm for dominant wavelength measurements.
3. Royal blue product is binned by radiometric power and peak wavelength rather than photometric lumens and dominant
wavelength. Philips Lumileds maintains a tolerance of ± 2nm for peak wavelength measurements.
4. CCT ±5% tester tolerance
5. Typical CRI (Color Rendering Index) for CoolWhite product is 70, NeutralWhite is 75, and WarmWhite is 80.
6. Spectral width at ½ of the peak intensity.
7. Total angle at which 90% of total luminous flux is captured.
8. Viewing angle is the off axis angle from lamp centerline where the luminous intensity is ½ of the peak value.
9. All white, green, cyan, blue and royal blue products are built with Indium Gallium Nitride (InGaN).
10. All red, redorange and amber products are built with Aluminum Indium Gallium Phosphide (AlInGaP).
11. Blue and royal blue power light sources represented here are IEC825 class 2 for eye safety.
LUXEON K2 Datasheet DS51 (7/07)
7
Electrical Characteristics
Electrical Characteristics at 350mA
Part Numbers LXK2xxx2xxx, Junction Temperature, TJ = 25ºC
Table 4.
Typical
Dynamic
Resistance
(Ω)
RD
Forward Voltage Vf [1]
(V)
Min.
Typ.
Max.
Color
CoolWhite[4]
[2]
Typical Temperature
Coefficient of
Forward
Voltage [3]
(mV/oC)
ΔVF / ΔTJ
Typical
Thermal
Resistance
Junction to
Case (oC/W)
RθJC
2.79
3.42
4.23
1.0
2.0
9 (13 for Star)
NeutralWhite
2.79
3.42
4.23
1.0
2.0
9 (13 for Star)
WarmWhite[4]
2.79
3.42
4.23
1.0
2.0
9 (13 for Star)
2.79
3.42
4.23
1.0
2.0
9
2.79
3.42
4.23
1.0
2.0
9
2.79
3.42
4.23
1.0
2.0
9
Royal Blue
2.79
3.42
4.23
1.0
2.0
9
[4]
[4]
Green
Cyan
[4]
Blue[4]
[4]
Red
2.31
2.95
3.51
2.4
2.0
12
RedOrange
2.31
2.95
3.51
2.4
2.0
12
Amber
2.31
2.95
3.51
2.4
2.0
12
Notes for Table 4:
1. Philips Lumileds maintains a tolerance of ±0.06V on forward voltage measurements.
2. Dynamic resistance is the inverse of the slope in linear forward voltage model for LEDs. See figures 14 and 15.
3. Measured between 25°C = TJ = 110°C at If = 350 mA.
4. The forward voltage of the LUXEON K2 LED will reduce by up to 0.30V at 350mA during the first few hours of operation
after SMT reflow. Due to this effect, Philips Lumileds recommends current source drive for consistent and reliable perform
ance. Cross connected series/parallel arrays or voltage drivers which could result in current hogging or variation in drive
current are not recommended. Please consult your Philips Lumileds authorized distributor or Philips Lumileds Sales
Representative for further information.
LUXEON K2 Datasheet DS51 (7/07)
8
Typical Electrical Characteristics at 700mA
Part Numbers LXK2xxx2xxx, Junction Temperature, TJ = 25ºC
Table 5.
Color
Typical Forward Voltage Vf [1]
(V)
CoolWhite
3.60
NeutralWhite
3.60
WarmWhite
3.60
Green
3.60
Cyan
3.60
Blue
3.60
Royal Blue
3.60
Red
3.60
RedOrange
3.60
Amber
3.60
Notes for Table 5:
1. Philips Lumileds maintains a tolerance of +/0.06V on forward voltage measurements.
2. Dynamic resistance is the inverse of the slope in linear forward voltage model for LEDs. See figures 14 and 15.
3
Measured between 25°C = TJ = 110°C at If = 700 mA.
LUXEON K2 Datasheet DS51 (7/07)
9
Electrical Characteristics at 1000mA
Part Numbers LXK2xxx4xxx, Junction Temperature, TJ = 25ºC
Table 6.
Typical
Dynamic
Resistance
(Ω)
RD
Forward Voltage Vf [1]
(V)
Min.
Typ.
Max.
Color
CoolWhite[4]
[2]
Typical Temperature
Coefficient of
Forward
Voltage [3]
(mV/oC)
ΔVF / ΔTJ
Typical
Thermal
Resistance
Junction to
Case (oC/W)
RθJC
3.03
3.72
4.95
0.6
2.0
9 (13 for Star)
3.03
3.72
4.95
0.6
2.0
9 (13 for Star)
WarmWhite
3.03
3.72
4.95
0.6
2.0
9 (13 for Star)
Green[4]
3.03
3.72
4.95
0.6
2.0
9
3.03
3.72
4.95
0.6
2.0
9
3.03
3.72
4.95
0.6
2.0
9
3.03
3.72
4.95
0.6
2.0
9
[4]
NeutralWhite
[4]
Cyan
Blue
[4]
[4]
[4]
Royal Blue
Notes for Table 6:
1. Philips Lumileds maintains a tolerance of ±0.06V on forward voltage measurements
2. Dynamic resistance is the inverse of the slope in linear forward voltage model for LEDs. See figure 14.
3. Measured between 25°C = TJ = 110°C at If = 1000 mA.
4. The forward voltage of the LUXEON K2 LED will reduce by up to 0.50V at 1000mA during the first few hours of operation
after SMT reflow. Due to this effect, Philips Lumileds recommends current source drive for consistent and reliable perform
ance. Cross connected series/parallel arrays or voltage drivers which could result in current hogging or variation in drive
current are not recommended. Please consult your Philips Lumileds authorized distributor or Philips Lumileds Sales
Representative for further information.
Typical Electrical Characteristics at 1500mA
Part Numbers LXK2xxx4xxx, Junction Temperature, TJ = 25ºC
Table 7.
Color
Typical Forward Voltage Vf [1]
(V)
CoolWhite
3.85
NeutralWhite
3.85
WarmWhite
3.85
Green
3.85
Cyan
3.85
Blue
3.85
Royal Blue
3.85
Notes for Table 7:
1. Philips Lumileds maintains a tolerance of +/0.06V on forward voltage measurements.
LUXEON K2 Datasheet DS51 (7/07)
10
Absolute Maximum Ratings
Table 8.
CoolWhite/NeutralWhite/
WarmWhite
Value
Green/Cyan
Blue/Royal Blue
Value
Red/RedOrange
/Amber
Value
DC Forward Current (mA)
1500
1500
700
Peak Pulsed Forward Current (mA)
1500
1500
700
Average Forward Current (mA)
1500
1500
700
2,000 V HBM
Class 2 JESD22A114B
2,000 V HBM
Class 2 JESD22A114B
2,000 V HBM
Class 2 JESD22A114B
LED Junction Temperature
150°C
185°C
150°C
Max Case Temperature
135°C
170°C
135°C
Parameter
ESD Sensitivity
Storage Temperature
40°C 185°C
40°C 185°C
40°C 185°C
K2 Star AluminumCore
PCB Temperature
105°C
N/A
N/A
Soldering Temperature
JEDEC 020c 260°C
JEDEC 020c 260°C
JEDEC 020c 260°C
Allowable Reflow Cycles
3
3
3
Autoclave Conditions
121°C at 2 ATM,
100% RH for 72 hours max
121°C at 2 ATM,
100% RH for 72 hours max
121°C at 2 ATM,
100% RH for 72 hours max
Reverse Voltage (Vr)
See Note 2
See Note 2
See Note 2
Notes for Table 8:
1. Proper current derating must be observed to maintain junction temperature below the maximum.
2. LEDs are not designed to be driven in reverse bias.
3. Stresses in excess of the absolute maximum ratings can cause damage to the emitter. Maximum Rating limits apply to
each parameter in isolation, all parameters having values within the Current Derating Curve. It should not be assumed that
limiting values of more than one parameter can be applied to the product at the same time. Exposures to the absolute
maximum ratings for extended periods can adversely affect device reliability. See Current Derating Curves in this document
for more details.
LUXEON K2 Datasheet DS51 (7/07)
11
JEDEC Moisture Sensitivity
Table 9.
Soak Requirements
Level
2a
Floor Life
Time
Conditions
4
weeks
≤ 30°C /
60% RH
Standard
Time
Conditions
(hours)
Accelerated Environment
Time
Conditions
(hours)
696 [1]
+ 5/0
120
+1/0
30°C / 60%
RH
60°C / 60%
RH
Notes for Table 9:
1. The standard soak time includes a default value of 24 hours for semiconductor manufacturer's exposure time (MET)
between bake and bag and includes the maximum time allowed out of the bag at the distributor's facility.
Reflow Soldering Characteristics
JEDEC 020c
Table 10.
Profile Feature
Lead Free Assembly
Average RampUp Rate (Tsmax to Tp)
3°C / second max
Preheat Temperature Min (Tsmin)
150°C
Preheat Temperature Max (Tsmax)
200°C
Preheat Time (tsmin to tsmax)
60 180 seconds
Temperature (TL)
217°C
Time Maintained Above Temperature (TL)
60 150 seconds
Peak / Classification Temperature (TP)
260°C
Time Within 5°C of Actual Peak Temperature (TP)
20 40 seconds
Ramp Down Rate
6°C / second max
Time 25°C to Peak Temperature
8 minutes max
Notes for Table 10:
1. All temperatures refer to topside of the package, measured on the package body surface.
LUXEON K2 Datasheet DS51 (7/07)
12
Mechanical Dimensions—SMT 4Lead Gullwing Form
Figure 1. 4lead Gullwing Package Outline Drawing.
Notes for Figure 1:
1. The anode side of the device is denoted by the chamfer on the part body. Electrical insulation between the case and the
board is required—slug of the device is not electrically neutral. Do not electrically connect either the anode or cathode to
the slug.
2. Do not handle the device by the lens except as described in Philips Lumileds document AB29.
3. Drawings not to scale.
4. All dimensions are in millimeters.
5. All dimensions without tolerances are for reference only.
6. Recommended solder paste thickness of 0.15mm.
LUXEON K2 Datasheet DS51 (7/07)
13
Solder Pad Design—SMT Lead Form
Conductive Pad
Conductive
Pad
Conductive
Pad
Soldermask
Package
Outline
Figure 2. 4Lead Gullwing Solder Pad Design.
Notes for Figure 2:
1. Electrical isolation is required between signal leads and hexagonal heat slug contact.
2. For optimal thermal performance, maximize board metallization at hexagonal heat slug contact.
Solder Pad Layout—SMT Lead Form
Figure 3. 4Lead Gullwing Package Solder Pad Layout.
Pin Out Diagram
Figure 4. 4Lead Gullwing Pin Out Diagram.
LUXEON K2 Datasheet DS51 (7/07)
14
Mechanical Dimensions—2Lead Gullwing Form[8]
Figure 5. 2Lead Gullwing Package Outline Drawing.
Notes for Figure 5:
1. The anode side of the device is denoted by the chamfer on the part body. Electrical insulation between the case and the board
is required—slug of the device is not electrically neutral. Do not electrically connect either the anode or cathode to the slug.
2. Do not handle the device by the lens except as described in Philips Lumileds document AB29—care must be taken to
avoid damage to the lens or the interior of the device that can be damaged by excessive force to the lens.
3. Drawings not to scale.
4. All dimensions are in millimeters.
5. All dimensions without tolerances are for reference only.
6. Recommended solder paste thickness of 0.15mm.
7. Available as a custom part number, contact your local Future Lumileds representative for more information.
8. The 2Lead Gullwing part is not recommended for use in solder reflow systems. Mount these parts with a thermal
adhesive and hot bar soldering. For conventional reflow surfacemounting, use 4Lead Gullwing Form.
LUXEON K2 Datasheet DS51 (7/07)
15
Solder Pad Design—2Lead Gullwing
Figure 6. 2Lead Gullwing Package Solder Pad Layout.
Notes for Figure 6:
1. Electrical isolation is required between signal leads and hexagonal heat slug contact.
2. For optimal thermal performance, maximize board metallization at hexagonal heat slug contact.
Solder Pad Layout—2Lead Gullwing
Figure 7. Solder Pad Layout 2Lead Gullwing.
Pin Out Diagram—Gullwing Form
PIN
NC (TRIMMED)
2
ANODE
3
NC (TRIMMED)
4
CATHODE
Figure 8. 2Lead Gullwing Pin Out Diagram.
LUXEON K2 Datasheet DS51 (7/07)
16
FUNCTION
1
Mechanical Dimensions—LUXEON K2 Star
LABEL
FORMAT
CATCODE
FLUX. COLOR. VF BIN
SERIAL NUMBER
SERIAL NUMBER
DATECODE
PRODUCTION WEEK & YEAR
PART NUMBER
PART NUMBER
BACK VIEW
PIN OUT DIAGRAM
PIN FUNCTION
1
NC
2
ANODE
3
NC
4
CATHODE
Figure 9. K2 Star Package Outline Drawing.
Notes for Figure 9:
1. Slots in aluminum core PCB for M3 or #4 mounting screw.
2. Electrical interconnection pads labeled on the aluminum core PCB with "+" and "" to denote positive and negative,
respectively. All positive pads are interconnected, as are all negative pads, allowing for flexibility in array interconnection.
3. Drawings not to scale.
4. All dimensions are in millimeters.
LUXEON K2 Datasheet DS51 (7/07)
17
Wavelength Characteristics
Green, Cyan, Blue, Royal Blue, Red, RedOrange and Amber at
Test Current
Junction Temperature, TJ = 25°C
Relative Spectral Power
Distribution
Cyan
Royal
Blue
RedOrange
Green
Blue
Amber
Red
Wavelength (nm)
Figure 10. Relative intensity vs. wavelength.
CoolWhite at Test Current
Junction Temperature, TJ = 25°C
Relative Specrtal Powerr
Distribution
1.0
0.8
0.6
0.4
0.2
0.0
350
400
450
500
550
600
650
700
750
800
Wavelength (nm)
Figure 11a. CoolWhite color spectrum of typical CCT part, integrated measurement.
LUXEON K2 Datasheet DS51 (7/07)
18
Wavelength Characteristics, Continued
Distribution
SpectraRelative
l PoweSpectral
r DistribPower
ution
NeutralWhite at Test Current
Junction Temperature, TJ = 25°C
350
400
450
500
550
600
650
700
750
800
Wavelength (nm )
Wavelength (nm)
Figure 11b. NeutralWhite color spectrum of typical CCT part, integrated measurement.
Distribution
Spectral
SpectRelative
ral Pow
er DiPower
stribution
WarmWhite at Test Current
Junction Temperature, TJ = 25°C
350
400
450
500
550
600
650
700
750
800
Wavelength (nm )
Wavelength (nm)
Figure 11c. WarmWhite color spectrum of typical CCT part, integrated measurement.
LUXEON K2 Datasheet DS51 (7/07)
19
Typical Light Output Characteristics Over Temperature
CoolWhite, NeutralWhite and WarmWhite at Test Current
150%
Relative Light Output (%)
Relative
Light Output (%)
140%
White Photometric
130%
120%
110%
100%
90%
80%
70%
60%
50%
-15
5
25
45
65
85
105
125
145
Junction TTemperature,
emperature, TJ = °TCJ (°C)
Junction
Figure 12a. Relative light output vs. junction temperature for white.
Green at Test Current
150%
Relative Light Output (%)
Relative Light Output (%)
140%
Green Photometric
130%
120%
110%
100%
90%
80%
70%
60%
50%
-15
5
25
45
65
85
105
125
Junction TTemperature,
emperature, TJ = °TCJ (°C)
Junction
Figure 12b. Relative light output vs. junction temperature for green.
LUXEON K2 Datasheet DS51 (7/07)
20
145
165
185
Typical Light Output Characteristics Over Temperature, Continued
Cyan at Test Current
150%
Relative Light Output (%)
Relative Light Output (%)
140%
Cyan Photometric
130%
120%
110%
100%
90%
80%
70%
60%
50%
-15
5
25
45
65
85
105
125
145
165
185
Junction
Junction TTemperature,
emperature, TJ = °T
C J (°C)
Figure 12c. Relative light output vs. junction temperature for cyan.
Blue at Test Current
150%
Relative Light Output (%)
Relative Light Output (%)
140%
Blue Photometric
130%
120%
110%
100%
90%
80%
70%
60%
50%
-15
5
25
45
65
85
105
125
145
Junction TTemperature,
emperature, TJ =T°CJ (°C)
Junction
Figure 12d. Relative light output vs. junction temperature for blue.
LUXEON K2 Datasheet DS51 (7/07)
21
165
185
Typical Light Output Characteristics Over Temperature, Continued
Royal Blue at Test Current
150%
Relative Light Output (%)
Relative
Light Output (%)
140%
Royal Blue Radiometric
130%
120%
110%
100%
90%
80%
70%
60%
50%
-15
5
25
45
65
85
105
125
145
165
Junction T
emperature, TJ =T°CJ (°C)
Junction
Temperature,
Figure 12e. Relative light output vs. junction temperature for royal blue.
Red, RedOrange and Amber at Test Current
200%
175%
Relative Light Output (%)
Relative Light Output (%)
Red Photometric
150%
Red-Orange Photometric
Amber Photometric
125%
100%
75%
50%
25%
0%
-20
0
20
40
60
80
100
120
140
o
JunctionTemperature,
Temperature, TTJJ=( °C)
C
Junction
Figure 13. Relative light output vs. junction temperature for red, redorange and amber.
LUXEON K2 Datasheet DS51 (7/07)
22
185
Typical Forward Current Characteristics
If - Forwrd Current (mA)
CoolWhite, NeutralWhite, WarmWhite, Green, Cyan, Blue
and Royal Blue, Junction Temperature, TJ = 25°C
1600
1500
1400
1300
1200
1100
1000
900
800
700
600
500
400
300
200
100
0
3.1
3.2
3.3
3.4
3.5
3.6
3.7
3.8
3.9
Vf - Forward Voltage (Volts)
Figure 14. Forward current vs. forward voltage for white, green, cyan, blue and royal blue.
Red, RedOrange and Amber, Junction Temperature, TJ = 25°C
IF - Average Forward Current (mA)
800
700
600
500
400
300
200
100
0
-100
2.0
2.2
2.4
2.6
2.8
3.0
3.2
3.4
3.6
3.8
VF - Forward Voltage (Volts)
Figure 15. Forward current vs. forward voltage for red, redorange and amber.
Notes for Figures 14 & 15:
Driving these high power devices at currents less than the test conditions (350 mA or 1000 mA) may produce unpre
dictable results and may be subject to variation in performance. Pulse width modulation (PWM) is recommended for
dimming effects.
LUXEON K2 Datasheet DS51 (7/07)
23
Typical Relative Luminous Flux
Normalized Luminous Flux
Relative Luminous Flux vs. Forward Current for CoolWhite,
NeutralWhite, WarmWhite, Green, Cyan, Blue and Royal Blue
Junction Temperature, TJ = 25°C
3.0
2.8
2.6
2.4
2.2
2.0
1.8
1.6
1.4
1.2
1.0
0.8
0.6
0.4
0.2
0.0
0
200
400
600
800
1000
1200
1400
1600
If - Forward Current (mA)
Figure 16. Relative luminous flux or radiometric power vs. forward current for white, green, cyan, blue
and royal blue at TJ = 25ºC maintained, test current 350 mA.
Normalized Luminous Flux
1.4
1.2
1.0
0.8
0.6
0.4
0.2
0.0
0
200
400
600
800
1000
1200
1400
1600
If - Forward Current (mA)
Figure 17. Relative luminous flux or radiometric power vs. forward current for white, green, cyan, blue
and royal blue at TJ = 25ºC maintained, test current 1000 mA.
Notes for Figures 16 & 17:
Driving these high power devices at currents less than the test conditions (350 mA or 1000 mA) may produce unpre
dictable results and may be subject to variation in performance. Pulse width modulation (PWM) is recommended for
dimming effects.
LUXEON K2 Datasheet DS51 (7/07)
24
Normalized
LuminousFlu
Flux
Normalized Luminous
Relative Luminous Flux vs. Forward Current for Red, RedOrange
and Amber, Junction Temperature, TJ = 25°C
2.0
1.8
1.6
1.4
1.2
1.0
0.8
0.6
0.4
0.2
0.0
0
100
200
300
400
500
600
700
800
If - Forward Current (mA)
Figure 18: Relative luminous flux or radiometric power vs. forward current for red, redorange and amber
at TJ = 25ºC maintained, test current 350 mA.
Note for Figure 18:
Driving these high power devices at currents less than the test conditions (350 mA or 1000 mA) may produce
unpredictable results and may be subject to variation in performance. Pulse width modulation (PWM) is recommended
for dimming effects.
LUXEON K2 Datasheet DS51 (7/07)
25
Current Derating Curves
Current Derating Curve for 350 mA Drive Current
CoolWhite, NeutralWhite, WarmWhite
IF - Forward Current (mA)
400
350
300
250
200
=50oºC/W
C/W
RRθJ-A
=50
JA
oºC/W
=
4
0
C/W
RRθJ-A
=40
JA
RRθJ-A
=30
=30oºC/W
C/W
JA
150
100
50
0
50
75
100
125
150
175
Temperature
TA -TAmbient
Temperature
(ºC)( C)
A - Ambient
`
Figure 19: Maximum forward current vs. ambient temperature, based on TJMAX = 150ºC.
Current Derating Curve for 350 mA Drive Current
Green, Cyan, Blue and Royal Blue
IF - Forward Current (mA)
400
350
300
250
200
RRθJJ-A
50oºC/W
C/W
=50
A =
o
=40 C/W
RRθJJ-A
A =40 ºC/W
150
R
o
J-A=30 C/W
RθJA=30ºC/W
100
50
0
50
75
100
125
150
175
TA T
- AAmbient
Temperature
(ºC)( C)
- Ambient
Temperature
`
Figure 20: Maximum forward current vs. ambient temperature, based on TJMAX = 185ºC.
LUXEON K2 Datasheet DS51 (7/07)
26
200
Current Derating Curve for 350 mA Drive Current
Red, RedOrange and Amber
IF - Forward Current (mA)
400
350
300
250
200
RθJA=50 ºC/W
RθJA=40 ºC/W
RθJA=30 ºC/W
150
100
50
0
50
75
100
125
150
175
°
TA - T
Ambient
Temperature (ºC)
A - Ambient Temperature ( C)
Figure 21: Maximum forward current vs. ambient temperature, based on TJMAX = 150ºC.
Current Derating Curve for 700 mA Drive Current
CoolWhite, NeutralWhite, WarmWhite
IF - Forward Current (mA)
800
700
600
500
400
=40oC/W
ºC/W
RRθJ-A
=40
JA
=30oC/W
ºC/W
RRθJ-A
=30
JA
=25oC/W
ºC/W
RRθJ-A
=25
JA
RRθJ-A
=20
=20oC/W
ºC/W
JA
RRθJ-A
=15oC/W
JA =15 ºC/W
300
200
100
0
0
25
50
75
100
125
150
Temperature
A - Ambient
TA -TAmbient
Temperature
(ºC) ( C)
ð
Figure 22: Maximum forward current vs. ambient temperature, based on TJMAX = 150ºC.
LUXEON K2 Datasheet DS51 (7/07)
27
175
Current Derating Curve for 700 mA Drive Current
Green, Cyan, Blue and Royal Blue
IF - Forward Current (mA)
800
700
600
500
400
RθJA=50 ºC/W
RθJA=40 ºC/W
RθJA=30 ºC/W
RθJA=25 ºC/W
RθJA=20 ºC/W
RθJA=15 ºC/W
300
200
100
0
0
25
50
75
100
125
150
175
200
TA - Ambient
Temperature
(ºC)
TA - Ambient
Temperature
( C)
Figure 23: Maximum forward current vs. ambient temperature, based on TJMAX = 175ºC.
Current Derating Curve for 700 mA Drive Current
Red, RedOrange and Amber
IF - Forward Current (mA)
800
700
600
500
400
RθJA=30 ºC/W
RθJA=25 ºC/W
RθJA=20 ºC/W
RθJA=15 ºC/W
300
200
100
0
0
25
50
75
100
≅
T A - Ambient
Temperature
( C)
TA - Ambient
Temperature
(ºC)
Figure 24: Maximum forward current vs. ambient temperature, based on TJMAX = 100ºC.
LUXEON K2 Datasheet DS51 (7/07)
28
125
Current Derating Curve for 1000 mA Drive Current
CoolWhite, NeutralWhite, WarmWhite, Green, Cyan, Blue and Royal Blue
IF - Forward Current (mA)
1200
1000
800
600
RθJA=30 ºC/W
RθJA=25 ºC/W
RθJA=20 ºC/W
RθJA=15 ºC/W
400
200
0
0
25
50
75
100
125
150
175
TA - Ambient
Temperature (ºC)
(°C)
TA - Ambient
Temperature
Figure 25: Maximum forward current vs. ambient temperature, based on TJMAX = 150ºC.
Current Derating Curve for 1500 mA Drive Current
CoolWhite, NeutralWhite, WarmWhite, Green, Cyan, Blue and Royal Blue
IF - Forward Current (mA)
1800
1500
1200
900
600
RθJA=20 ºC/W
RθJA=15 ºC/W
300
0
0
25
50
75
100
125
150
Temperature (°C)
TA - TAmbient
Temperature
(ºC)
A - Ambient
Figure 26: Maximum forward current vs. ambient temperature, based on TJMAX = 150ºC.
LUXEON K2 Datasheet DS51 (7/07)
29
175
Typical Radiation Patterns
Typical Representative Spatial Radiation Pattern
for White Lambertian
100%
90%
Relative Intensity (%)
80%
70%
60%
50%
40%
30%
20%
10%
0%
-100
-80
-60
-40
-20
0
20
40
60
80
100
Angular Displacement (Degrees)
Figure 27: Typical Representative Spatial Radiation Pattern for White Lambertian.
Typical Polar Radiation Pattern for White Lambertian
0º
- 30º
30º
- 60º
60º
- 90º
0
20% 40% 60%
Figure 28: Typical Polar Radiation Pattern for White Lambertian.
LUXEON K2 Datasheet DS51 (7/07)
30
80%
90º
100%
Typical Representative Spatial Radiation Pattern
for Green, Cyan, Blue and Royal Blue Lambertian
100%
90%
Relative Intensity (%)
80%
70%
60%
50%
40%
Typical Upper Bound
Typical Lower Bound
30%
20%
10%
0%
-100
-80
-60
-40
-20
0
20
40
60
80
100
Angular Displacement (Degrees)
Figure 29: Typical Representative Spatial Radiation Pattern for Green, Cyan, Blue and Royal Blue Lambertian.
Typical Polar Radiation Pattern
for Green, Cyan, Blue and Royal Blue Lambertian
0º
30º
- 30º
- 60º
60º
- 90º
0
20% 40% 60%
80%
90º
100%
Typical Upper Bound
Typical Lower Bound
Figure 30: Typical Polar Radiation Pattern for Green, Cyan, Blue and Royal Blue Lambertian.
LUXEON K2 Datasheet DS51 (7/07)
31
Typical Representative Spatial Radiation Pattern
for Red, RedOrange and Amber Lambertian
100%
90%
Relative Intensity (%)
80%
70%
60%
50%
40%
30%
20%
10%
0%
-100
-80
-60
-40
-20
0
20
40
60
80
Angular Displacement (Degrees)
Figure 31: Typical Representative Spatial Radiation Pattern for Red, Red_Orange and Amber Lambertian.
Typical Polar Radiation Pattern
for Red, RedOrange and Amber Lambertian
0º
30º
- 30º
- 60º
60º
- 90º
0
20% 40% 60%
80%
90º
100%
Figure 32: Typical Polar Radiation Pattern for Red, RedOrange and Amber Lambertian.
LUXEON K2 Datasheet DS51 (7/07)
32
100
Emitter Reel Packaging
LUXEON K2 Datasheet DS51 (7/07)
33
White Binning Information
Figure 33: White Binning Structure
LUXEON K2 Datasheet DS51 (7/07)
34
LUXEON K2 CoolWhite Bin Structure
Figure 34: CoolWhite Bin Structure
LUXEON K2 Datasheet DS51 (7/07)
35
LUXEON K2 CoolWhite Bin Structure, Continued
CoolWhite LUXEON K2 Emitters are tested and binned by x,y coordinates.
19 Color Bins, CCT Range 10,000K to 4,500K
Table 11.
Cool White Bin Structure
Bin Code
Y0
YA
XM
XN
X0
XP
WM
WN
W0
WP
X
Y
0.274238
0.303051
0.307553
0.282968
0.282968
0.307553
0.311163
0.289922
0.300667
0.332708
0.310778
0.283772
0.283772
0.310778
0.293192
0.270316
0.301093
0.313617
0.314792
0.303051
0.342244
0.354992
0.344438
0.332708
0.303051
0.314792
0.316042
0.305170
0.332708
0.344438
0.333222
0.322386
0.305170
0.316042
0.317466
0.307553
0.322386
0.333222
0.320438
0.310778
0.307553
0.317466
0.319597
0.311163
0.310778
0.320438
0.301303
0.293192
0.313617
0.328636
0.328823
0.314792
0.354992
0.368952
0.356917
0.344438
0.314792
0.328823
0.329006
0.316042
0.344438
0.356917
0.345092
0.333222
0.316042
0.329006
0.329220
0.317466
0.333222
0.345092
0.331331
0.320438
0.317466
0.329220
0.329393
0.318606
0.320438
0.331331
0.320211
0.310201
Typical CCT
(K)
Bin Code
8000
WQ
8000
VM
6700
VN
6700
V0
6700
VP
6700
UM
6000
UN
6000
U0
6000
UP
X
Y
0.318606
0.329393
0.329544
0.319597
0.328636
0.348147
0.346904
0.328823
0.310201
0.320211
0.310495
0.301303
0.368952
0.385629
0.371742
0.356917
0.328823
0.346904
0.345781
0.329006
0.356917
0.371742
0.359190
0.345092
0.329006
0.345781
0.344443
0.329220
0.345092
0.359190
0.344232
0.331331
0.329220
0.344443
0.343352
0.329393
0.331331
0.344232
0.332034
0.320211
0.348147
0.367294
0.364212
0.346904
0.385629
0.400290
0.382878
0.371742
0.346904
0.364212
0.362219
0.345781
0.371742
0.382878
0.371616
0.359190
0.345781
0.362219
0.359401
0.344443
0.359190
0.371616
0.355699
0.344232
0.344443
0.359401
0.357079
0.343352
0.344232
0.355699
0.342581
0.332034
6000
Note for Table 11:
1. Philips Lumileds maintains a tester tolerance of ± 0.005 on x, y color coordinates.
LUXEON K2 Datasheet DS51 (7/07)
36
Typical CCT
(K)
6000
5300
5300
5300
5300
4750
4750
4750
4750
LUXEON K2 NeutralWhite Bin Structure
Figure 35: NeutralWhite Bin Structure.
LUXEON K2 Datasheet DS51 (7/07)
37
LUXEON K2 NeutralWhite Bin Structure, Continued
NeutralWhite LUXEON K2 Emitters are tested and binned by x,y coordinates.
12 Color Bins, CCT Range 4,500K to 3,500K
Table 12.
NeutralWhite Bin Structure
Bin Code
TM
TN
T0
TP
SM
SN
X
Y
0.367294
0.385953
0.381106
0.364212
0.364212
0.381106
0.378264
0.362219
0.400290
0.412995
0.393747
0.382878
0.382878
0.393747
0.382458
0.371616
0.362219
0.378264
0.374075
0.359401
0.371616
0.382458
0.365822
0.355699
0.359401
0.374075
0.370582
0.357079
0.355699
0.365822
0.351953
0.342581
0.385953
0.402270
0.396279
0.381106
0.412995
0.422776
0.403508
0.393747
0.381106
0.396279
0.392368
0.378264
0.393747
0.403508
0.390932
0.382458
Typical CCT
(K)
Bin Code
4300
S0
4300
SP
4300
RM
4300
RN
3950
R0
3950
RP
X
Y
0.378264
0.392368
0.387071
0.374075
0.374075
0.387071
0.382598
0.370582
0.382458
0.390932
0.373899
0.365822
0.365822
0.373899
0.359515
0.351953
0.402270
0.420940
0.414776
0.396279
0.422776
0.432618
0.416097
0.403508
0.396279
0.414776
0.408593
0.392368
0.403508
0.416097
0.399525
0.390932
0.392368
0.408593
0.402113
0.387071
0.390932
0.399525
0.382156
0.373899
0.387071
0.402113
0.396564
0.382598
0.373899
0.382156
0.367284
0.359515
Note for Table 12:
1.
Philips Lumileds maintains a tester tolerance of ± 0.005 on x, y color coordinates.
LUXEON K2 Datasheet DS51 (7/07)
38
Typical CCT
(K)
3950
3950
3650
3650
3650
3650
LUXEON K2 WarmWhite Bin Structure
Figure 36: WarmWhite Bin Structure.
LUXEON K2 Datasheet DS51 (7/07)
39
LUXEON K2 WarmWhite Bin Structure, Continued
WarmWhite LUXEON K2 Emitters are tested and binned by x,y coordinates.
16 Color Bins, CCT Range 3,500K to 2,670K
Table 13.
WarmWhite Bin Structure
Bin Code
QM
QN
Q0
QP
PM
PN
P0
PP
X
Y
0.420940
0.438458
0.431186
0.414776
0.414776
0.431186
0.423956
0.408593
0.432618
0.440399
0.423386
0.416097
0.416097
0.423386
0.406472
0.399525
0.408593
0.423956
0.416487
0.402113
0.399525
0.406472
0.389001
0.382156
0.402113
0.416487
0.409996
0.396564
0.382156
0.389001
0.373814
0.367284
0.438458
0.453820
0.445639
0.431186
0.440399
0.445980
0.428680
0.423386
0.431186
0.445639
0.437578
0.423956
0.423386
0.428680
0.411632
0.406472
0.423956
0.437578
0.429373
0.416487
0.406472
0.411632
0.394281
0.389001
0.416487
0.429373
0.422124
0.409996
0.389001
0.394281
0.378952
0.373814
Typical CCT
(K)
Bin Code
3375
NM
3375
NN
3375
N0
3375
NP
3150
MM
3150
MN
3150
M0
3150
MP
X
Y
0.453820
0.470507
0.461404
0.445639
0.445639
0.461404
0.452512
0.437578
0.445980
0.450832
0.433334
0.428680
0.428680
0.433334
0.416241
0.411632
0.437578
0.452512
0.443600
0.429373
0.411632
0.416241
0.399111
0.394281
0.429373
0.443600
0.435591
0.422124
0.394281
0.399111
0.383714
0.378952
0.470507
0.486648
0.476733
0.461404
0.450832
0.454191
0.436634
0.433334
0.461404
0.476733
0.467132
0.452512
0.433334
0.436634
0.419632
0.416241
0.452512
0.467132
0.457663
0.443600
0.416241
0.419632
0.402866
0.399111
0.443600
0.457663
0.448994
0.435591
0.399111
0.402866
0.387515
0.383714
Note for Table 13:
1.
Philips Lumileds maintains a tester tolerance of ± 0.005 on x, y color coordinates.
LUXEON K2 Datasheet DS51 (7/07)
40
Typical CCT
(K)
2950
2950
2950
2950
2760
2760
2760
2760
Company Information
Philips Lumileds Lighting Company is a world class supplier of Light
Emitting Diodes (LEDs) and produces billions of LEDs annually. Philips
Lumileds is a fully integrated supplier producing core LED material in
all three base colors (red, green, blue) and white. Philips Lumileds has
R&D centers in San Jose, California and in The Netherlands as well as
Philips Lumileds may make process or
materials changes affecting the perform
ance or other characteristics of our
products. These products supplied after
such changes will continue to meet
published specifications, but may not
be identical to products supplied as
samples or under prior orders.
production capabilities in San Jose, Penang Malaysia and Singapore.
Founded in 1999, Philips Lumileds is the highflux LED technology
leader and is dedicated to bridging the gap between solidstate LED
technology and the lighting world. Philips Lumileds technologies,
LEDs and systems are enabling new applications and markets in the
lighting world.
www.luxeon.com
www.lumiledsfuture.com
For technical assistance or the
location of your nearest sales
office contact any of the
following:
North America:
1 888 589 3662
[email protected]
Europe:
00 800 443 88 873
[email protected]
Asia Pacific:
800 5864 5337
[email protected]
©2007 Philips Lumileds Lighting Company. All rights reserved. Product specifications are subject to
change without notice. Luxeon is a registered trademark of the Philips Lumileds Lighting Company in
the United States and other countries.
Japan:
800 5864 5337
[email protected]
Similar pages