MPD MD105D-05VHI Miniature 1w, sip, very high isolation dc/dc con vert er Datasheet

MD100VHI Series
Miniature 1W, SIP,
Very High Isolation
DC/DC Converters
Electrical Specifications
Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Key Features:
• 1W Output Power
Input
Parameter
Conditions
• Miniature SIP Case
• 5,200 VDC Isolation
Input Voltage Range
• Single & Dual Outputs
• >2.0 MHour MTBF
Input Filter
• -40°C to +85°C Operation
Output
• Industry Standard Pin-Out
Min.
Typ.
Max.
5 VDC Input
4.50
5.0
5.50
Units
12 VDC Input
10.80
12.0
13.20
15 VDC Input
13.50
15.0
16.50
24 VDC Input
21.60
24.0
26.40
Typ.
Max.
±5.0
%
Dual Output, Balanced Loads
±0.1
±1.0
%
For VIN Change of 1%
±1.2
VDC
Internal Capacitor
Parameter
Conditions
Min.
Output Voltage Accuracy
Output Voltage Balance
Line Regulation
Load Regulation, See Note 1
Units
%
See Model Selection Guide
Ripple & Noise (20 MHz), See Note 2
Temperature Coefficient
±0.01
Output Short Circuit
100
mV P - P
±0.02
%/°C
Max.
Units
Momentary (0.5 Sec.)
General
Parameter
Conditions
Isolation Voltage
Min.
60 Seconds
Isolation Resistance
500 VDC
Isolation Capacitance
VDC
10
100 kHz, 1V
Common Mode Transient Immunity
Typ.
5,200
G
7
pF
15
Switching Frequency
kV/µS
100
kHz
Environmental
Parameter
Conditions
Operating Temperature Range
Ambient
Operating Temperature Range
Case
Storage Temperature Range
Min.
Typ.
Max.
Units
-40
+25
+85
°C
-55
Cooling, See Note 3
+100
°C
+125
°C
95
%
Free Air Convection
Humidity
RH, Non-condensing
Physical
Case Size
See Mechanical Drawing (Page 2)
Case Material
Non-Conductive Black Plastic (UL-94V0)
MicroPower Direct
Weight
292 Page Street
Suite D
Stoughton, MA 02072
USA
Reliability Specifications
0.076 Oz (2.4g)
T: (781) 344-8226
F: (781) 344-8481
E: [email protected]
W: www.micropowerdirect.com
Parameter
Parameter
Conditions
MTBF
Min.
MIL HDBK 217F, 25°C, Gnd Benign
Typ.
Max.
2.0
Units
MHours
Absolute Maximum Ratings
Conditions
Min.
5 VDC Input
Input Voltage Surge (1 Sec)
Lead Temperature
Typ.
Max.
-0.7
9.0
12 VDC Input
-0.7
18.0
15 VDC Input
-0.7
20.0
24 VDC Input
-0.7
30.0
1.5 mm From Case For 10 Sec
260
Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings.
www.micropowerdirect.com
Units
VDC
°C
www.micropowerdirect.com
Model Selection Guide
Input
Model
Number
MD105S-03VHI
MD105S-05VHI
MD105S-09VHI
MD105S-12VHI
MD105S-15VHI
MD105D-05VHI
MD105D-09VHI
MD105D-12VHI
MD105D-15VHI
MD112S-03VHI
MD112S-05VHI
MD112S-09VHI
MD112S-12VHI
MD112S-15VHI
MD112D-05VHI
MD112D-09VHI
MD112D-12VHI
MD112D-15VHI
MD115S-03VHI
MD115S-05VHI
MD115S-09VHI
MD115S-12VHI
MD115S-15VHI
MD115D-05VHI
MD115D-09VHI
MD115D-12VHI
MD115D-15VHI
MD124S-03VHI
MD124S-05VHI
MD124S-09VHI
MD124S-12VHI
MD124S-15VHI
MD124D-05VHI
MD124D-09VHI
MD124D-12VHI
MD124D-15VHI
Voltage (VDC)
Nominal
5
5
5
5
5
5
5
5
5
12
12
12
12
12
12
12
12
12
15
15
15
15
15
15
15
15
15
24
24
24
24
24
24
24
24
24
Output
Current (mA)
Voltage Current
Range
Full-Load No-Load (VDC) (mA, Max)
4.5 - 5.5
286
35
3.3
303
4.5 - 5.5
286
35
5.0
200
4.5 - 5.5
266
35
9.0
111
4.5 - 5.5
261
35
12.0
84
4.5 - 5.5
254
35
15.0
66
4.5 - 5.5
282
35
±5.0
±100
4.5 - 5.5
269
35
±9.0
±56
4.5 - 5.5
262
35
±12.0
±42
4.5 - 5.5
254
35
±15.0
±33
10.8 - 13.2
117
17
3.3
303
10.8 - 13.2
117
17
5.0
200
10.8 - 13.2
110
17
9.0
111
10.8 - 13.2
108
17
12.0
84
10.8 - 13.2
104
17
15.0
66
10.8 - 13.2
116
17
±5.0
±100
10.8 - 13.2
111
17
±9.0
±56
10.8 - 13.2
108
17
±12.0
±42
10.8 - 13.2
104
17
±15.0
±33
13.5 - 16.5
95
16
3.3
303
13.5 - 16.5
95
16
5.0
200
13.5 - 16.5
89
16
9.0
111
13.5 - 16.5
90
16
12.0
84
13.5 - 16.5
84
16
15.0
66
13.5 - 16.5
94
16
±5.0
±100
13.5 - 16.5
90
16
±9.0
±56
13.5 - 16.5
86
16
±12.0
±42
13.5 - 16.5
84
16
±15.0
±33
21.6 - 26.4
60
12
3.3
303
21.6 - 26.4
60
12
5.0
200
21.6 - 26.4
56
12
9.0
111
21.6 - 26.4
53
12
12.0
84
21.6 - 26.4
52
12
15.0
66
21.6 - 26.4
59
12
±5.0
±100
21.6 - 26.4
56
12
±9.0
±56
21.6 - 26.4
55
12
±12.0
±42
21.6 - 26.4
53
12
±15.0
±33
Notes:
1. Output load regulation is specified for a load change of 20% to 100%.
2. When measuring output ripple & noise, it is recommended that an external ceramic capacitor
(0.33 µF typ.) be placed from the +VOUT to the -VOUT pins for single output units and from
each output to common for dual output models.
3. Free air convection is typically 20 LFM. The units should not be operated in still air (0 LFM).
4. Operation at no load will not damage these units, however, they may not meet all specifications.
5. It is recommended that a fuse be used on the input of a power supply for protection.
See the table above for the correct rating.
Output
Load
Fuse Rating
Capacitive Efficiency
Regulation
Slow-Blow
Load
(%, Typ)
(% Typ)
(mA)
(µF Max)
20.0
15.0
10.0
10.0
10.0
15.0
10.0
10.0
10.0
20.0
15.0
10.0
10.0
10.0
15.0
10.0
10.0
10.0
20.0
15.0
10.0
10.0
10.0
15.0
10.0
10.0
10.0
20.0
15.0
10.0
10.0
10.0
15.0
10.0
10.0
10.0
1,000
470
470
220
220
±220
±220
±100
±100
1,000
470
470
220
220
±220
±220
±100
±100
1,000
470
470
220
220
±220
±220
±100
±100
1,000
470
470
220
220
±220
±220
±100
±100
70
70
75
77
78
71
75
77
78
71
71
76
78
79
72
76
78
79
70
70
75
75
79
71
75
78
79
70
70
75
78
80
71
75
77
78
600
600
600
600
600
600
600
600
600
250
250
250
250
250
250
250
250
250
200
200
200
200
200
200
200
200
200
125
125
125
125
125
125
125
125
125
Mechanical Dimensions
Derating Curve
Pin Connections
Pin
1
2
5
Single
+VIN
-VIN
-VOUT
Dual
+VIN
-VIN
-VOUT
Pin
6
7
Single
No Pin
+VOUT
Dual
Common
+VOUT
MicroPower Direct
Notes:
• All dimensions are typical in inches (mm)
• Tolerance x.xx = ±0.01 (±0.25)
• Pin 1 is marked by a “dot” or indentation on the unit
We Power Your Success - For Less!
292 Page Street Ste D Stoughton, MA 02072
•
TEL: (781) 344-8226
•
FAX: (781) 344-8481
•
E-Mail: [email protected]
Similar pages