Rosenberger LU8-005-600 Cable assembly Datasheet

Technical Data Sheet
Cable assembly
LU8-005-XXX
RF_35/09.14/6.2
Dieses Dokument ist urheberrechtlich geschützt ● This document is protected by copyright ● Rosenberger Hochfrequenztechnik GmbH & Co. KG
RPC-2.40 JACK – RTK 125 Cable – RPC-2.40 PLUG
All dimensions are in mm; tolerances: ± 3mm for A ≤ 300 mm; ± 1% for A > 300 mm
Available variants
Type
max. Insertion loss at 50 GHz
Weight (g) / pce
LU8-005-XXX
≤ 0.00397 dB/mm * A mm + 0.70 dB
0.206 g/mm * A mm + 150 g
XXX – length in mm = A
- Standard lengths are 600, 800 and 1000mm. The smallest possible length is 400mm. -
Assembly parts
Connector left
Connector right
Cable
Armour
Electrical data
Impedance
Frequency
Return loss
Insertion loss
After 90° bending
Straight after 3x90° bending
Amplitude stability
Return loss stability
Shielding Effectiveness
RPC-2.40 ruggedized jack
09KR123-2U8S3
RPC-2.40 plug
09S123-2U8S3
RTK 125
Metal tubing with fixed bending rate and protection braid
50 Ω
DC to 50 GHz
≥ 26 dB, DC to 4 GHz
≥ 17 dB, 4 GHz to 50 GHz
see table available variants
≤ 1.3°, DC to 4 GHz
≤ 7.0°, 4 GHz to 50 GHz
≤ 1.0°, DC to 4 GHz
≤ 4.5°, 4 GHz to 50 GHz
≤ 0.03 dB, DC to 4 GHz
≤ 0.08 dB, 4 GHz to 50 GHz
≥ 45 dB, DC to 4 GHz
≥ 35 dB, 4 GHz to 50 GHz
≥ 100 dB up to 1 GHz
Individual testing and documentation:
Measurement plot with all 4 S-Parameters (S11; S22; S21; S12) is included with the cable assembly and on the
backside the care and handling instruction is printed.
Rosenberger Hochfrequenztechnik GmbH & Co. KG
P.O.Box 1260
D-84526 Tittmoning
Germany
www.rosenberger.de
Tel. : +49 8684 18-0
Email : [email protected]
Page
1/2
Technical Data Sheet
Cable assembly
LU8-005-XXX
RF_35/09.14/6.2
Dieses Dokument ist urheberrechtlich geschützt ● This document is protected by copyright ● Rosenberger Hochfrequenztechnik GmbH & Co. KG
RPC-2.40 JACK – RTK 125 Cable – RPC-2.40 PLUG
Mechanical data
Minimum bend radius:
60 mm
Environmental data
Temperature range
RoHS
-40°C to +85°C
compliant
While the information has been carefully compiled to the best of our knowledge, nothing is intended as representation or warranty on
our part and no statement herein shall be construed as recommendation to infringe existing patents. In the effort to improve our
products, we reserve the right to make changes judged to be necessary.
Draft
Date
Approved
Date
Rev.
Engineering change number
Name
Date
Martin Moder
18.08.14
Herbert Babinger
08.06.16
g00
16-0803
K. Mitterer
08.06.16
Rosenberger Hochfrequenztechnik GmbH & Co. KG