GS120 120W AC-DC Single Output Desktop series Features : Universal AC input / Full range 3 pole AC inlet IEC320-C14 Built-in active PFC function, PF>0.97 Protections: Short circuit / Overload / Over voltage / Over temperature Fully enclosed plastic case Approvals: UL / CUL / PSE / TUV / BSMI / CCC / CB / FCC / CE Class power (with earth pin) LED indicator for power on No load power consumption<0.5W ErP step2 compliant NRCan compliant Meet EISA 2007 (Energy Independence and Security Act) 2 years warranty (except for 48V) SPECIFICATION ORDER NO. SAFETY MODEL NO. DC VOLTAGE OUTPUT GS120A20=R7B,P1M GS120A24=R7B,P1M GS120A48=R7B,P1M GS120A12 12V GS120A15 15V GS120A20 20V GS120A24 24V GS120A48 48V 2.5A 8.5A 7A 6A 5A 0 ~ 7A 0 ~ 6A 0 ~ 5A 0 ~ 2.5A RATED POWER (max.) 102W 105W 120W 120W 120W 120mVp-p 150mVp-p 180mVp-p 240mVp-p RIPPLE & NOISE (max.) Note.2 80mVp-p VOLTAGE TOLERANCE Note.3 5.0% 5.0% 5.0% 3.0% 2.0% LINE REGULATION 1.0% 1.0% 1.0% 1.0% 1.0% 5.0% 5.0% 4.0% 3.0% 2.0% Note.4 SETUP, RISE TIME Note.6 2000ms, 30ms / 230VAC HOLD UP TIME (Typ.) VOLTAGE RANGE Note.7 85 ~ 264VAC 20ms / 230VAC EFFICIENCY (Typ.) 2500ms, 30ms / 115VAC at full load 20ms / 115VAC at full load 120 ~ 370VDC 47 ~ 63Hz PF>0.97 / 230VAC PF>0.99 / 115VAC at full load R7B 87.5% 89% 89% 90% 91% P1M ----- ----- 88.5% 89.5% 90.5% AC CURRENT INRUSH CURRENT (max.) LEAKAGE CURRENT(max.) OVERLOAD PROTECTION OVER VOLTAGE 1.4A / 115VAC 0.7A / 230VAC 70A / 230VAC 0.75mA / 240VAC 105 ~ 160% rated output power Protection type : Hiccup mode, recovers automatically after fault condition is removed 105 ~ 135% rated output voltage Protection type : Shut down o/p voltage, re-power on to recover OVER TEMPERATURE RTH2 100 10 Protection type : Shut down o/p voltage, re-power on to recover WORKING TEMP. WORKING HUMIDITY -30 ~ +70 (Refer to "Derating Curve") 20% ~ 90% RH non-condensing ENVIRONMENT STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION SAFETY STANDARDS SAFETY & WITHSTAND VOLTAGE ISOLATION RESISTANCE EMC (Note. 5) EMC EMISSION NOTE GS120A15-R7B 0 ~ 8.5A POWER FACTOR (Typ.) CONNECTOR GS120A12-R7B CURRENT RANGE FREQUENCY RANGE OTHERS geprUfre Sicherheit RATED CURRENT LOAD REGULATION INPUT TUV Rheinland Product Safety -40 ~ +85 , 10 ~ 95% RH 0.03% / (0~50 ) 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes UL60950-1, TUV EN60950-1, BSMI CNS14336, CCC GB4943, J60950-1(except for 48V) approved I/P-O/P: 3KVAC I/P-O/P:100M Ohms / 500VDC / 25 / 70% RH Compliance to EN55022(CISPR22) ,EN61204-3 class B, CNS13438 class B, GB9254-1 class B, FCC PART 15, EN61000-3-2,3, GB17625.1 EMC IMMUNITY Compliance to EN61000-4-2,3,4,5,6,8,11, light industry level, criteria A MTBF DIMENSION PACKING PLUG 400.7Khrs min. MIL-HDBK-217F(25 ) 167*67*35mm (L*W*H) 0.62Kg; 20pcs/13.4Kg/0.9CUFT See page 2 ; Other type available by customer requested CABLE See page 2 ; Other type available by customer requested 1.All parameters are specified at 230VAC input, rated load, 25 70% RH ambient. 2.Ripple & noise are measured at 20MHz by using a 12" twisted pair terminated with a 0.1uf & 47uf capacitor. 3.Tolerance: includes set up tolerance, line regulation, load regulation. 4.Line regulation is measured from low line to high line at rated load. 5.The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. 6. Length of set up time is measured at first cold start. Turning ON/OFF the power supply may lead to increase of the set up time. 7. Derating may be needed under low input voltage. Please check the derating curve for more details. File Name:GS120-SPEC 2012-03-06 GS120 120W AC-DC Single Output Desktop Mechanical Specification Case No.GS120A 35 series Unit:mm UL2464 18AWGx4C 1200 50mm 167 30 3mm 67 23 14 POWER LED 35 UL2464 16AWGx2C 1200 50mm 167 30 3mm 67 11 Outside C"+" Inside POWER LED Plug Assignment Standard plug(For 20V,24V,48V only) Standard plug (all models) 11 PIN NO. OUTPUT 2 1 3 4 C"+" P1M R7B 1,4 +V 2,3 -V P/N OUTPUT CENTER + ID 2.5 x OD 5.5 Outside AC FG Inside -V connected to AC FG -V connected to AC FG Derating Curve Static Characteristics 100 100 230VAC 85 80 80 70 100VAC LOAD (%) LOAD (%) 60 50 40 20 -30 10 20 30 40 45 50 60 AMBIENT TEMPERATURE ( ) 70 (HORIZONTAL) 60 50 40 85 95 100 110 120 140 160 180 200 220 240 264 INPUT VOLTAGE (VAC) 60Hz File Name:GS120-SPEC 2012-03-06