Vitec MTWA16-S07 15w multi-plug wall mount for i.t. equipment Datasheet

MTWA16 SERIES
15W Multi-Plug Wall Mount for I.T. Equipment






1 Year Warranty
Wide Input Voltage 90 to 264 VAC, 47 to 63Hz
Interchangeable AC plug(USA, UK, Europe, Australia)
Output Voltage Available From 5VDC Thru 48VDC
Single Output
Class II Insulation
Energy Star 2.0, CEC V, and RoHS compliance
Approvals:
Single Output
Product Number
MTWA16-S02
MTWA16-S03
MTWA16-S04
MTWA16-S05
MTWA16-S06
MTWA16-S07
MTWA16-S08
MTWA16-S09
MTWA16-S10
MTWA16-S11
Output Voltage
5 ~ 5.99 VDC
6.5 ~ 8 VDC
8 ~ 11 VDC
11 ~ 13 VDC
13 ~ 16 VDC
16 ~ 21 VDC
21 ~ 27 VDC
27 ~ 33 VDC
33 ~ 40 VDC
40 ~ 48 VDC
Max. Output Current
2.40 ~ 2.00 A
1.85 ~ 1.50 A
1.68 ~ 1.22 A
1.36 ~ 1.15 A
1.15 ~ 0.94 A
0.94 ~ 0.72 A
0.72 ~ 0.55 A
0.55 ~ 0.45 A
0.45 ~ 0.37 A
0.37 ~ 0.32 A
Total Regulation
5%
5%
5%
5%
5%
5%
3%
3%
3%
3%
Maximum Output Power
12W
12W
13.5W
15W
15W
15W
15W
15W
15W
15W
Total Regulation is conditioned by below configuration
(S02~S04: AWG18/4FT output cable)
(S05~S09: AWG20/4FT output cable)
(S10~S11: AWG22/4FT output cable)
Electrical Characteristics
Parameter
Input Voltage
Input Frequency
Output Power Range
Input Current (Low Line)
Input Current (High Line)
Low Line Inrush Current
High Line Inrush Current
Efficiency
Line Regulation
Load Regulation
Over Voltage Protection
Over Current Protection
Transient Response
Hold-Up Time
Start Up Time
Ripple & Noise (Peak to Peak)
Safety Ground Leakage Current
Temperature Coefficient
No-load Power Consumption
Test Conditions
Universal Input Voltage
Operating Voltage
Vin=100 to 240VAC
Io=Full load, Vin=115VAC
Io=Full load, Vin=230VAC
Io=Full load, 25°C, Cool start, Vin=115VAC
Io=Full load, 25°C, Cool start, Vin=230VAC
Io=Full Load, Vin=230VAC
Io=Full Load
Vin=230VAC
Nil But, Output protected to short circuit conditions
Io=Full Load to Half Load, Vin=100VAC
Io=Full Load, Vin=230VAC
Io=Full Load, Vin=100VAC
Full Load, Vin=90VAC
Io=Full Load, Vin=240VAC
All output
No load, Vin=240VAC
Min.
100
90
47
0
74.7
Typ.
25
50
79
0.5
3
Nil
Max.
240
264
63
15
0.4
0.26
50
100
85
1
10
4
12
2
0.5
-0.04
0.25
3
1
0.25
0.04
0.3
Unit
VAC
VAC
Hz
W
A
A
A
A
%
%
%
%
%
mS
mS
S
%
mA
%/°C
W
Conditions
Parameter
Operating Temperature
Storage Temperature
Operating Humidity
Storage Humidity
Operating Temperature at 25°C, Calculated per MIL-HDBK-217F
De-rate linearly from 100 % load at 40°C to 50 % load at 70°C
Test Conditions
Min.
0
-40
0
0
0.1M
Typ.
40
Max.
70
85
95
75
Unit
°C
°C
%
%
Hrs
Min.
Unit
4242
50
B
B
VDC
MΩ
CLASS
CLASS
Approvals and Compliance
Parameter
Dielectric Withstanding Voltage for Primary to secondary
Isolation Resistance
EMI requirements for CISPR-22
EMI requirements for FCC PART-15
Test Conditions
Primary to secondary
Test Voltage= 500VDC
Vin=220VAC
Vin=110VAC
Mechanical and PIN out
Note:
1.
Dimensions are shown in mm.
2.
Weight: 165g approx.
3.
Optional output connector.
Similar pages