L P V- 6 0 60W Single Output Switching Power Supply series Features : Constant voltage design Universal AC input / Full range Withstand 300VAC surge input for 5 seconds Protections: Short circuit / Overload / Over voltage Cooling by free air convection Fully encapsulated with IP67 level (Note.8) Fully isolated plastic case Class power unit, no FG Class 2 power unit Pass LPS Suitable for LED lighting and moving sign applications (Note.7) 100% full load burn-in test Low cost, high reliability 2 years warranty LPS IP67 SPECIFICATION MODEL OUTPUT LPV-60-5 LPV-60-12 LPV-60-15 LPV-60-24 LPV-60-36 5V 12V 15V 24V 36V 48V RATED CURRENT 8A 5A 4A 2.5A 1.67A 1.25A CURRENT RANGE 0 ~ 8A 0 ~ 5A 0 ~ 4A 0 ~ 2.5A 0 ~ 1.67A 0 ~ 1.25A RATED POWER 40W 60W 60W 60W 60W 60W 120mVp-p 120mVp-p 150mVp-p 150mVp-p 150mVp-p RIPPLE & NOISE (max.) Note.2 80mVp-p VOLTAGE TOLERANCE Note.3 8.0% LINE REGULATION 1.0% SETUP, RISE TIME VOLTAGE RANGE 5.0% 6.0% 2.0% 50ms/230VAC Note.4 90 ~ 264VAC 16ms/115VAC at full load 127 ~ 370VDC FREQUENCY RANGE 47 ~ 63Hz EFFICIENCY (Typ.) 76% AC CURRENT (Typ.) INRUSH CURRENT(max.) 1.2A/115VAC 1A/230VAC COLD START 30A/115VAC LEAKAGE CURRENT 0.25mA / 240VAC OVERLOAD PROTECTION OVER VOLTAGE WORKING TEMP. WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION SAFETY STANDARDS 83% 83% 86% Protection type : Hiccup mode, recovers automatically after fault condition is removed 5.75 ~ 6.75V 13.8 ~ 16.2V 17.25 ~ 20.25V 27.6 ~ 32.4V PACKING NOTE 55.2 ~ 64.8V -30 ~ +70 (Refer to "Derating Curve") 20 ~ 90% RH non-condensing -40 ~ +80 , 10 ~ 95% RH 0.03%/ (0 ~ 50 ) 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes UL879(except for LPV-60-5), UL1310(except for LPV-60-5), CSA C22.2 No. 207-M89(except for LPV-60-5, LPV-60-48), CAN/CSA C22.2 No. 223-M91(except for LPV-60-5,LPV-60-48), IP67 approved ; design refer to TUV EN60950-1 I/P-O/P:>100M Ohms / 500VDC / 25 / 70% RH Compliance to EN55022 (CISPR22) Class B, EN61000-3-2 Class A, EN61000-3-3 DIMENSION 41.4 ~ 48.6V Protection type : Shut down o/p voltage, re-power on to recover I/P-O/P:3KVAC MTBF 86% 110 ~ 150% rated output power EMC ISOLATION RESISTANCE 86% 60A/230VAC SAFETY & WITHSTAND VOLTAGE EMC EMISSION EMC IMMUNITY LPV-60-48 Note.6 500ms, 20ms / 230VAC 500ms, 20ms / 115VAC at full load(for 5~36V) ; 500ms, 30ms / 230VAC 500ms, 30ms / 115VAC at full load(for 48V) HOLD UP TIME (Typ.) OTHERS ( except for 5V,48V ) DC VOLTAGE LOAD REGULATION INPUT ( for 48V only) Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, light industry level, criteria A 732Khrs min. MIL-HDBK-217F (25 ) 162.5*42.5*32mm (L*W*H) 0.4Kg; 32pcs/13.8Kg/0.56CUFT 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. Derating may be needed under low input voltage. Please check the static characteristics for more details. 5. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again. 6. Length of set up time is measured at first cold start. Turning ON/OFF the power supply may lead to increase of the set up time. 7. The unit might not be suitable for lighting applications in EU countries. Please check with your local authorities for the possible use of the unit. 8. Suitable for indoor use or outdoor use without direct sunlight exposure. Please avoid immerse in the water over 30 minute. File Name:LPV-60-SPEC 2012-03-20 L P V- 6 0 60W Single Output Switching Power Supply Mechanical Specification Case No. 976A 162.5 600 30 series Unit:mm 600 30 3.5 3.6 42.5 15 UL1015 18AWG AC/N(Blue) AC/L(Brown) 3.6 81.5 T case 3.5 3.5 UL1007 16AWG +V(Red) -V(Black) 3.5 32 T case: Max. Case Temperature. Recommend Mounting Direction Block Diagram fosc : 65KHz EMI FILTER & RECTIFIERS I/P RECTIFIERS & FILTER POWER SWITCHING O.L.P. +V -V DETECTION CIRCUIT PWM CONTROL O.V.P. Derating Curve Static Characteristics 100 100 230VAC 90 80 80 70 115VAC LOAD (%) LOAD (%) 60 40 20 -30 -15 0 15 30 40 50 AMBIENT TEMPERATURE ( ) 60 70 (HORIZONTAL) 60 50 40 90 100 125 135 145 155 165 175 180 200 230 264 INPUT VOLTAGE (V) 60Hz File Name:LPV-60-SPEC 2012-03-20