Rosenberger LU1-054-500 Cable assembly - standardportfolio Datasheet

Technical Data Sheet
Cable assembly - Standardportfolio
LU1-054-XXX
RF_35/05.10/6.0
Dieses Dokument ist urheberrechtlich geschützt ● This document is protected by copyright ● Rosenberger Hochfrequenztechnik GmbH & Co. KG
RPC-2.92 Plug / RPC-2.92 Plug RA– RTK 106
All dimensions are in mm; tolerances according to ISO 2768 c-H
Available variants
Type
“A”
(mm)
“C”
(mm)
“D”
(mm)
“E”
(mm)
Insertion loss
≤ (dB) at 40 GHz
LU1-054-500
500
20±3
30±2
25±2
2.00
LU1-054-1000
1000
20±3
30±2
25±2
3.40
LU1-054-1500
1500
20±3
30±2
25±2
4.80
LU1-054-2000
2000
20±3
30±2
25±2
6.20
Marking
ROSENBERGER
WW/YY
XXX
LU1-054-500
ROSENBERGER
WW/YY
XXX
LU1-054-1000
ROSENBERGER
WW/YY
XXX
LU1-054-1500
ROSENBERGER
WW/YY
XXX
LU1-054-2000
Weight
(g) / pce
36
54
73
90
WW - week
YY - year
XXX – serial no.
Documents
Technical data sheet connectors
Technical data sheet cable
RPC-2.92 plug
RPC-2.92 plug right angle
RTK 106
02S121-2U1S3
02S221-2U1S3
RPC-2.92 plug
RPC-2.92 plug right angle
RTK 106
02S121-2U1S3
02S221-2U1S3
Assembly parts
Connector left
Connector right
Cable
Rosenberger Hochfrequenztechnik GmbH & Co. KG
P.O.Box 1260
D-84526 Tittmoning
Germany
www.rosenberger.de
Tel. : +49 8684 18-0
Fax : +49 8684 18-499
Email : [email protected]
Page
1/2
Technical Data Sheet
Cable assembly - Standardportfolio
LU1-054-XXX
RPC-2.92 Plug / RPC-2.92 Plug RA– RTK 106
Electrical data
50 Ω
DC to 40 GHz
≥ 15.6 dB, DC to 40 GHz
see table available variants
≥ 100 dB up to 1 GHz
RF_35/05.10/6.0
Dieses Dokument ist urheberrechtlich geschützt ● This document is protected by copyright ● Rosenberger Hochfrequenztechnik GmbH & Co. KG
Impedance
Frequency
Return loss
Insertion loss
RF-leakage
Mechanical data
Minimum bend radius:
Single
Multiple
6.35 mm
38.4 mm
Environmental data
Temperature range
2002/95/EC (RoHS)
-40°C to +85°C
compliant
Packing
1 pce in box
Standard
While the information has been carefully compiled to the best of our knowledge, nothing is intended as representation or warranty on
our part and no statement herein shall be construed as recommendation to infringe existing patents. In the effort to improve our
products, we reserve the right to make changes judged to be necessary.
Draft
Date
Approved
Date
Rev.
Engineering change number
Name
Date
Martin Moder
03/02/12
Roland Neuhauser
22/02/12
a00
12-s045
Maik Knoll
22/02/12
Rosenberger Hochfrequenztechnik GmbH & Co. KG
P.O.Box 1260
D-84526 Tittmoning
Germany
www.rosenberger.de
Tel. : +49 8684 18-0
Fax : +49 8684 18-499
Email : [email protected]
Page
2/2