DB Lectro JQX-102FAZ20BDC48V0.9 Used in household appliance like air conditioning , heater and instruments etc. Datasheet

JQX- 102F
CH0064847—2001
30.5×16.0×23.5
R2133344
30.5×16.0×26.5
Features
Can be welded directly onto PCB.
Used in household appliance like air conditioning , heater and instruments etc.
Ordering Information
JQX-102F A Z 20 b DC12V 0.9
1
2
3
4
5
6
1 Part number:JQX-102F
2 Contact arrangement:A:1A
3 Enclosure:Z: Dust cover
7
4 Contact rating:Resistive:20A/250VAC;
5 Terminal:b:PC type;NIL:PC type and QC type
6 Coil rated Voltage(V):DC:5,12,24,48
7 Coil power consumption:0.9:0.9W
Contact Data
Contact Arrangement
Contact Material
Contact Rating( Resistive)
Max. Switching Power
Max. Switching Voltage
Contact Resistance or Voltage drop
Operation
Electrical
life
Mechanical
1ASPSTNO
AgSnO2
20A/250VAC
5000VA
300VAC
አ30m (at 1A/14VDC)
105
2106
Max. Switching Current:20A
Item 3.12 of IEC255-7
Item 3.30 of IEC255-7
Item 3.31 of IEC255-7
Coil Parameter
Dash
numbers
Coil voltage
VDC
Coil
resistance
±10%
Pickup
voltage
VDC(max)
(70%of rated
voltage )
release
voltage
VDC(min)
(10% of
rated
voltage)
Rated
Max.
005-900
5
6
27.8
3.5
0.5
012-900
12
14.4
160
8.4
1.2
024-900
24
28.8
640
16.8
2.4
048-500
48
57.6
2560
33.6
4.8
Coil power
consumption
W
Operate
Time
ms
Release
Time
ms
0.9
20
10
CAUTION: 1.The use of any coil voltage less than the rated coil voltage will compromise the operation of the relay.
2.Pickup and release voltage are for test purposes only and are not to be used as design criteria.
99
www.dblectro.com
JQX-102F
Operation condition
Insulation Resistance
Dielectric Strength
Between contacts
Between contact and coil
Shock resistance
Vibration resistance
Terminals strength
Solderability
Ambient Temperature
Relative Humidity
Mass
1000M
min (at 500VDC)
Item 7 of IEC255-5
50Hz 1500V
50Hz 4500V
surge voltage:10kV
Functional:200m/s2
11ms
Survival:1000 m/s2 11ms
10~55Hz
double amplitude Functional 1.5mm
double amplitude Survival 2.0mm
10N 8N
2352 30.5s
-25~55
85% (at 40)
23g
Item 6
Item 6
Item 8
of IEC255-5
of IEC255-5
of IEC255-5
IEC68-2-27 Test Ea
IEC68-2-6 Test Fc
IEC68-2-6 Test Fc
IEC68-2-21 Test Ua1 and Ua2
IEC68-2-20 Test Ta method 1
IEC68-2-3Test Ca
Qualification inspection:
Perform the qualification test as specified in the table of IEC255-19-1 and minimum sample size 24.
Safety approvals
Safety approval
Load
CCEE
20A/250VAC
TüV
20A/250VAC COS=0.9
Dimensions (Unit: mm)
×
×0.8
×
×0.8
Dimensions
Mounting (Bottom views)
Wiring diagram
(Bottom views)
mm
0.3
0.5
0.8
1.4
1.5
1.8
2
3.2
3.4
3.5
5.2
6.2
6.3
6.4
8.3
8.4
9.4
10
10.2
12
16
18.4
22
23.5
26.5
27.6
30.5
NOTES 1).Dimensions are in millimeter.
2).Inch equivalents are given for general information only.
www.dblectro.com
>àçÇá
0.012
0.020
0.031
0.055
0.059
0.071
0.079
0.126
0.134
0.138
0.205
0.244
0.248
0.252
0.327
0.331
0.370
0.394
0.402
0.472
0.630
0.724
0.866
0.925
1.043
1.087
1.201
Similar pages