Technical Sales United States (866) 531-6285 [email protected] Requirements and Compatibility | Ordering Information | Detailed Specifications For user manuals and dimensional drawings, visit the product page resources tab on ni.com. Last Revised: 2010-02-09 14:44:16.0 4-Channel, 14 S/s, 24-Bit, ±80 mV C Series Thermocouple Input Module NI 9211 4 thermocouple or ±80 mV analog inputs Hot-swappable operation -40 to 70 °C operating range NIST-traceable calibration 24-bit resolution; 50/60 Hz noise rejection Overview The NI 9211 C Series thermocouple input module for use with NI CompactDAQ and CompactRIO chassis includes a 24-bit delta-sigma ADC, antialiasing filters, open-thermocouple detection, and cold-junction compensation for high-accuracy thermocouple measurements. It contains NIST-traceable calibration and a channel-to-earth ground double-isolation barrier for safety, noise immunity, and high common-mode voltage range. Back to Top Requirements and Compatibility OS Information Driver Information Software Compatibility Real-Time OS NI-DAQmx LabVIEW Windows NI-RIO LabWindows/CVI Measurement Studio SignalExpress Visual Basic Visual C# Visual C++ Visual Studio Visual Studio .NET Back to Top Comparison Tables Thermocouple Module Channels Sample Rate Resolution Feature NI 9213 16 1,200 S/s 24-bit Lowest cost/channel NI 9219 4 50 S/s/ch 24-bit Channel-to-channel isolation NI 9211 4 14 S/s 24-bit Low-channel count Back to Top Application and Technology 1/9 www.ni.com Application and Technology High-accuracy C Series analog input modules for NI CompactDAQ and CompactRIO provide high-performance measurements for a wide variety of industrial, in-vehicle, and laboratory sensors and signal types. Each module includes built-in signal conditioning and an integrated connector with screw terminal or cable options for flexible and low-cost signal wiring. All modules feature CompactRIO Extreme Industrial Certifications and Ratings. C Series Compatibility The C Series hardware family features more than 50 measurement modules and several chassis and carriers for deployment. With this variety of modules, you can mix and match measurements such as temperature, acceleration, flow, pressure, strain, acoustic, voltage, current, digital, and more to create a custom system. Install the modules in one of several carriers to create a single module USB, Ethernet, or Wi-Fi system, or combine them in chassis such as NI CompactDAQ and CompactRIO to create a mixed-measurement system with synchronized measurements. You can install up to eight modules in a simple, complete NI CompactDAQ USB data acquisition system to synchronize all of the analog output, analog input, and digital I/O from the modules. For a system without a PC, CompactRIO holds up to eight modules and features a built-in processor, RAM, and storage for an embedded data logger or control unit. For higher-speed control, CompactRIO chassis incorporate a field-programmable gate array (FPGA) that you can program with NI LabVIEW software to achieve silicon-speed processing on I/O data from C Series modules. Advanced Features When used with CompactRIO, C Series analog input modules connect directly to reconfigurable I/O (RIO) FPGA hardware to create high-performance embedded systems. The reconfigurable FPGA hardware within CompactRIO provides a variety of options for custom timing, triggering, synchronization, filtering, signal processing, and high-speed decision making for all C Series analog modules. For instance, with CompactRIO, you can implement custom triggering for any analog sensor type on a per-channel basis using the flexibility and performance of the FPGA and the numerous arithmetic and comparison function blocks built into the LabVIEW FPGA Module. Key Features High-accuracy, high-performance analog measurements for any CompactRIO embedded system, R Series expansion chassis, or NI CompactDAQ chassis Screw terminals, BNC, D-Sub, spring terminals, strain relief, high voltage, cable, solder cup backshell, and other connectivity options Available channel-to-earth ground double-isolation barrier for safety, noise immunity, and high common-mode voltage range CompactRIO Extreme Industrial Certifications and Ratings Built-in signal conditioning for direct connection to sensors and industrial devices Visit ni.com/compactrio or ni.com/compactdaq for up-to-date information on module availability, example programs, application notes, and other developer tools. Connectivity Accessories NI CompactDAQ and CompactRIO systems are designed to provide flexible options for low-cost field wiring and cabling. Most C Series modules have a unique connector block option that offers secure connections to your C Series system. Table 2 contains all of the connector blocks available for C Series I/O modules. Table 3 lists the recommended connector block accessories for each C Series analog input module. The NI 9932 kit provides strain relief and operator protection from high-voltage signals for any 10-position screw-terminal module. 2/9 www.ni.com The NI 9936 consists of 10-position screw-terminal plugs for any 10-position screw-terminal module. Visit ni.com/compactrio or ni.com/compactdaq for up-to-date information on accessories. Back to Top Ordering Information For a complete list of accessories, visit the product page on ni.com. Products Part Number Recommended Accessories Part Number No accessories required. Back to Top Software Recommendations LabVIEW Professional Development System for Windows Advanced software tools for large project development Automatic code generation using DAQ Assistant and Instrument I/O Assistant Tight integration with a wide range of hardware Advanced measurement analysis and digital signal processing Open connectivity with DLLs, ActiveX, and .NET objects Capability to build DLLs, executables, and MSI installers Back to Top Support and Services System Assurance Programs NI system assurance programs are designed to make it even easier for you to own an NI system. These programs include configuration and deployment services for your NI PXI, CompactRIO, or Compact FieldPoint system. The NI Basic System Assurance Program provides a simple integration test and ensures that your system is delivered completely assembled in one box. When you configure your system with the NI Standard System Assurance Program, you can select from available NI system driver sets and application development environments to create customized, reorderable software configurations. Your system arrives fully assembled and tested in one box with your software preinstalled. When you order your system with the standard program, you also receive system-specific documentation including a bill of materials, an integration test report, a recommended maintenance plan, and frequently asked question documents. Finally, the standard program reduces the total cost of owning an NI system by providing three years of warranty coverage and calibration service. Use the online product advisors at ni.com/advisor to find a system assurance program to meet your needs. 3/9 www.ni.com Calibration NI measurement hardware is calibrated to ensure measurement accuracy and verify that the device meets its published specifications. To ensure the ongoing accuracy of your measurement hardware, NI offers basic or detailed recalibration service that provides ongoing ISO 9001 audit compliance and confidence in your measurements. To learn more about NI calibration services or to locate a qualified service center near you, contact your local sales office or visit ni.com/calibration. Technical Support Get answers to your technical questions using the following National Instruments resources. Support - Visit ni.com/support to access the NI KnowledgeBase, example programs, and tutorials or to contact our applications engineers who are located in NI sales offices around the world and speak the local language. Discussion Forums - Visit forums.ni.com for a diverse set of discussion boards on topics you care about. Online Community - Visit community.ni.com to find, contribute, or collaborate on customer-contributed technical content with users like you. Repair While you may never need your hardware repaired, NI understands that unexpected events may lead to necessary repairs. NI offers repair services performed by highly trained technicians who quickly return your device with the guarantee that it will perform to factory specifications. For more information, visit ni.com/repair. Training and Certifications The NI training and certification program delivers the fastest, most certain route to increased proficiency and productivity using NI software and hardware. Training builds the skills to more efficiently develop robust, maintainable applications, while certification validates your knowledge and ability. Classroom training in cities worldwide - the most comprehensive hands-on training taught by engineers. On-site training at your facility - an excellent option to train multiple employees at the same time. Online instructor-led training - lower-cost, remote training if classroom or on-site courses are not possible. Course kits - lowest-cost, self-paced training that you can use as reference guides. Training memberships and training credits - to buy now and schedule training later. Visit ni.com/training for more information. Extended Warranty NI offers options for extending the standard product warranty to meet the life-cycle requirements of your project. In addition, because NI understands that your requirements may change, the extended warranty is flexible in length and easily renewed. For more information, visit ni.com/warranty. OEM NI offers design-in consulting and product integration assistance if you need NI products for OEM applications. For information about special pricing and services for OEM customers, visit ni.com/oem. Alliance Our Professional Services Team is comprised of NI applications engineers, NI Consulting Services, and a worldwide National Instruments Alliance Partner program of more than 700 independent consultants and integrators. Services range from start-up assistance to turnkey system integration. Visit ni.com/alliance. Back to Top Detailed Specifications The following specifications are typical for the range –40 to 70 °C unless otherwise noted. Input Characteristics Number of channels 4 thermocouple channels, 1 internal autozero channel, 1 internal cold-junction compensation channel ADC resolution 24 bits Type of ADC Delta-Sigma Sampling mode Scanned Voltage measurement range ±80 mV Works over temperature ranges defined by NIST (J, K, T, E, N, B, R, S thermocouple types) 70 ms per channel; 420 ms total for all channels including the autozero and cold-junction channels Temperature measurement ranges Conversion time Common-mode voltage range Channel-to-COM ±1.5 V COM-to-earth ground ±250 V Common-mode rejection ratio (0 to 60 Hz) Channel-to-COM 95 dB 4/9 www.ni.com COM-to-earth ground >170 dB Input bandwidth (–3 dB) 15 Hz Noise rejection (at 50 and 60 Hz) 85 dB min Overvoltage protection ±30 V between any input and COM Differential input impedance 20 MΩ Input current 50 nA Input noise 1 μVrms Gain error 0.05% max at 25 °C, 0.06% typ at –40 to 70 °C, 0.1% max at –40 to 70 °C Offset error (with autozero channel on) 15 μV typ, 20 μV max Gain error from source impedance Add 0.05 ppm per Ω when source impedance >50 Ω Offset error from source impedance Add 0.05 μV typ, 0.07 μV max per Ω source impedance >50 Ω Cold-junction compensation sensor accuracy 0 to 70 °C 0.6 °C typ, 1.3 °C max –40 to 70 °C 1.7 °C max 633,012 hours at 25 °C; Bellcore Issue 2, Method 1, Case 3, Limited Part Stress Method MTBF Note Contact NI for Bellcore MTBF specifications at other temperatures or for MIL-HDBK-217F specifications. Temperature Measurement Accuracy Measurement sensitivity 1 With autozero channel on Types J, K, T, E, N <0.07 °C Types B <0.25 °C Types R, S <0.60 °C With autozero channel off Types J, K, T, E, N <0.05 °C Types B <0.20 °C Types R, S <0.45 °C The following figures show the typical and maximum errors for each thermocouple type when used with the NI 9211 over the full temperature range. The figures also display the maximum errors for the thermocouple types with the NI 9211 at room temperature, which is 15 to 35 °C. The figures account for gain errors, offset errors, differential and integral nonlinearity, quantization errors, noise errors, and isothermal errors. The figures do not account for the accuracy of the thermocouple itself. Thermocouple Types J and N Errors Thermocouple Type K Errors 5/9 www.ni.com Thermocouple Types T and E Errors Thermocouple Type B Errors Thermocouple Types R and S Errors 6/9 www.ni.com Power Requirements Power consumption from chassis Active mode 170 mW max Sleep mode 4 mW max Thermal dissipation (at 70 °C) Active mode 170 mW max Sleep mode 4 mW max Physical Characteristics If you need to clean the module, wipe it with a dry towel. Note For two-dimensional drawings and three-dimensional models of the C Series module and connectors, visit ni.com/dimensions and search by module number. Screw-terminal wiring 12 to 24 AWG wire with 10 mm (0.39 in.) of insulation stripped from the end Torque for screw terminals 0.5 to 0.6 N · m (4.4 to 5.3 lb · in.) Ferrules 0.25 mm2 to 2.5 mm2 Weight 150 g (5.3 oz) Safety Safety Voltages Connect only voltages that are within the following limits. Channel-to-COM ±30 V max Isolation Channel-to-channel None Channel-to-earth ground Continuous 250 Vrms, Measurement Category II Withstand 2,300 Vrms, verified by a 5 s dielectric withstand test Measurement Category II is for measurements performed on circuits directly connected to the electrical distribution system (MAINS 2 ). This category refers to local-level electrical distribution, such as that provided by a standard wall outlet (for example, 115 AC voltage for U.S. or 230 AC voltage for Europe). Examples of Measurement Category II are measurements performed on household appliances, portable tools, and similar hardware. Caution Do not connect the NI 9211 to signals or use for measurements within Measurement Categories III or IV. Hazardous Locations U.S. (UL) Class I, Division 2, Groups A, B, C, D, T4; Class I, Zone 2, AEx nC IIC T4 Canada (C-UL) Class I, Division 2, Groups A, B, C, D, T4; Class I, Zone 2, Ex nC IIC T4 Europe (DEMKO) EEx nC IIC T4 Safety Standards This product is designed to meet the requirements of the following standards of safety for electrical equipment for measurement, control, and laboratory use: IEC 61010-1, EN 61010-1 UL 61010-1, CSA 61010-1 Note For UL and other safety certifications, refer to the product label or the Online Product Certification section. 7/9 www.ni.com Electromagnetic Compatibility This product is designed to meet the requirements of the following standards of EMC for electrical equipment for measurement, control, and laboratory use: EN 61326 (IEC 61326): Class A emissions; Industrial immunity EN 55011 (CISPR 11): Group 1, Class A emissions AS/NZS CISPR 11: Group 1, Class A emissions FCC 47 CFR Part 15B: Class A emissions ICES-001: Class A emissions Note For the standards applied to assess the EMC of this product, refer to the Online Product Certification section. Note For EMC compliance, operate this device with double-shielded cables. CE Compliance This product meets the essential requirements of applicable European Directives, as amended for CE marking, as follows: 2006/95/EC; Low-Voltage Directive (safety) 2004/108/EC; Electromagnetic Compatibility Directive (EMC) Note For the standards applied to assess the EMC of this product, refer to the Online Product Certification section. Online Product Certification Refer to the product Declaration of Conformity (DoC) for additional regulatory compliance information. To obtain product certifications and the DoC for this product, visit ni.com/certification, search by module number or product line, and click the appropriate link in the Certification column. Shock and Vibration To meet these specifications, you must panel mount the system and either affix ferrules to the ends of the terminal wires or use the NI 9932 backshell kit to protect the connections. Operating vibration Random (IEC 60068-2-64) 5 grms, 10 to 500 Hz Sinusoidal (IEC 60068-2-6) 5 g, 10 to 500 Hz Operating shock (IEC 60068-2-27) 30 g, 11 ms half sine, 50 g, 3 ms half sine, 18 shocks at 6 orientations Environmental National Instruments C Series modules are intended for indoor use only but may be used outdoors if installed in a suitable enclosure. Refer to the manual for the chassis you are using for more information about meeting these specifications. Operating temperature (IEC 60068-2-1, IEC 60068-2-2) –40 to 70 °C Storage temperature (IEC 60068-2-1, IEC 60068-2-2) –40 to 85 °C Ingress protection IP 40 Operating humidity (IEC 60068-2-56) 10 to 90% RH, noncondensing Storage humidity (IEC 60068-2-56) 5 to 95% RH, noncondensing Maximum altitude 2,000 m Pollution Degree (IEC 60664) 2 Environmental Management National Instruments is committed to designing and manufacturing products in an environmentally responsible manner. NI recognizes that eliminating certain hazardous substances from our products is beneficial not only to the environment but also to NI customers. For additional environmental information, refer to the NI and the Environment Web page at ni.com/environment. This page contains the environmental regulations and directives with which NI complies, as well as other environmental information not included in this document. Waste Electrical and Electronic Equipment (WEEE) EU Customers At the end of their life cycle, all products must be sent to a WEEE recycling center. For more information about WEEE recycling centers and National Instruments WEEE initiatives, visit ni.com/environment/weee.htm. Calibration You can obtain the calibration certificate for this device at ni.com/calibration. Calibration interval 1 year 8/9 www.ni.com 1 Measurement sensitivity represents the smallest change in temperature that a sensor can detect. It is a function of noise. The values assume the full measurement range of the standard thermocouple sensor according to ASTM E230-87. 2 MAINS is defined as a hazardous live electrical supply system that powers hardware. Suitably rated measuring circuits may be connected to the MAINS for measuring purposes. Back to Top ©2010 National Instruments. All rights reserved. CompactRIO, CVI, FieldPoint, LabVIEW, Measurement Studio, National Instruments, National Instruments Alliance Partner, NI, ni.com, NI CompactDAQ, and SignalExpress are trademarks of National Instruments. The mark LabWindows is used under a license from Microsoft Corporation. Windows is a registered trademark of Microsoft Corporation in the United States and other countries. Other product and company names listed are trademarks or trade names of their respective companies. A National Instruments Alliance Partner is a business entity independent from National Instruments and has no agency, partnership, or joint-venture relationship with National Instruments. My Profile | RSS | Privacy | Legal | Contact NI © 2012 National Instruments Corporation. All rights reserved. 9/9 www.ni.com