GAS DISCHARGE TUBE 8x6mm No. A930/A931/A932 Specifications 2-electrode (10kA/10A) Medium Discharge Current Series This product is not recommended Features for new designs. Please refer to Non-radioactive Littelfuse series SL1011B. Lead Free A930 can be used in holder No. 706 Applications Telecommunication Data Transmission Trigger Circuits Power Line Modules Packaging A930: A931: A932: 00=Bulk (1.000 pcs.) 01=Reel (500 pcs.) 02=Blister Tape (600 pcs.) Materials Housing: Gas: Leads: Ceramic non-radioactive tin plated Arc Voltage @ 1A ~ 15V Transition Glow to Arc @ ~ 0.8A Standard Operating temperature -40°C to +90°C UL-497B complies to ITU-T K.12 (formerly CCITT) complies to DIN 57845/VDE 0845 Climatic Category complies to IEC 60068-1 +40°C, 21 days, <93% humidity Approvals UL-recognized WebLinks Soldering characteristics complies to IEC 60068-2-20 (A931) Further info see: http://www.wickmanngroup.com/ download/orderinfo_surgearr.pdf http://www.wickmanngroup.com/ download/crossref_surgearr.pdf Soldering Heat Resistance complies to IEC 60068-2-58 Marking , Type, Nom. Voltage, Date Unit Weight ca. 1.5g Characteristics Type/ Order Code DC Tolerance Impulse sparkover sparkover voltage voltage (1kV/µs) typ. A930 S0 0090 01 00 A931 S0 0090 01 01 A932 S0 0090 01 02 Glow Insulation Capacitance 8/20µs 8/20µs AC AC Approval Voltage Resistance (@1MHZ) Nominal Single Nominal Alternating (@100 Vdc or Impulse Impulse Discharge Discharge @50Vdc for 90V) Discharge Discharge Current Current Current Current (50Hz; 1s; (50Hz; (10 times) (1 time) (10 times) 9 cycles) UL-rec. 90V +/- 20% <550V ~ 60V > 10GΩ < 1.5 pF 10kA 12kA 10A 65A • A930 S0 0230 01 00 A931 S0 0230 01 01 230V A932 S0 0230 01 02 +/- 20% <600V ~ 60V > 10GΩ < 1.5 pF 10kA 12kA 10A 65A • A930 S0 0350 01 00 A931 S0 0350 01 01 350V A932 S0 0350 01 02 +/- 20% <800V ~ 60V > 10GΩ < 1.5 pF 10kA 12kA 10A 65A • A930 S0 0600 04 00 A931 S0 0600 04 01 600V -10/+20% <1.100V ~ 60V > 10GΩ < 1.5 pF 10kA 12kA 10A 65A • other values on request Specifications are subject to change without notice. Order Example 050915 Qty. OrderNumber WebSite Europe Tel: +49 2302 662-107 www.wickmanngroup.com E-mail: [email protected] Type A930 Failsafe Option Sparkover Volt. S0 0090 Americas Tel: +1 404 699-7820 E-mail: [email protected] Tolerance 01 Asia Tel: +852 26 14-1108 E-mail: [email protected] Packaging 00 China Tel: +86 21 6432 5146 E-mail: [email protected] GAS DISCHARGE TUBE Dimensions (mm) A930/A931/A932 A930 A931 A932 050915 WebSite Europe Tel: +49 2302 662-107 www.wickmanngroup.com E-mail: [email protected] Americas Tel: +1 404 699-7820 E-mail: [email protected] Asia Tel: +852 26 14-1108 E-mail: [email protected] China Tel: +86 21 6432 5146 E-mail: [email protected]