Mean Well DKE10B-24 10w dc-dc regulated dual output converter Datasheet

DKE10
10W DC-DC Regulated Dual Output Converter
series
Features :
2:1 wide input range
4:1 wide input range(option)
1000VDC I/O isolation
3000VDC I/O isolation(option)
Built-in EMI filter
Protections: Short circuit / Overload
Cooling by free air convection
Six-sided shield metal case
100% burn-in test
Low cost / High reliability
Approvals: FCC / CE
2 years warranty
SPECIFICATION
ORDER NO.
DKE10A- DKE10B- DKE10C- DKE10A- DKE10B- DKE10C- DKE10A- DKE10B- DKE10C- DKE10A- DKE10B- DKE10C05
05
05
12
12
12
15
15
15
24
24
24
5V
12V
15V
24V
DC VOLTAGE
CURRENT RANGE
100 ~ 1000mA
OUTPUT
RIPPLE & NOISE (max.) Note.2 50mVp-p
LINE REGULATION
Note.3
0.3%
LOAD REGULATION
Note.4
0.5%
DC CURRENT
60mVp-p
80mVp-p
Full load
A: 1100mA B: 530mA
C: 270mA
No load
A: 30mA
C: 8mA
B: 16mA
83%
82%
80%
80%
FILTER
PROTECTION
Pi network
Fuse recommended
OVER CURRENT
160% ~ 250% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
PROTECTION
82%
81%
85%
All output equipped with short circuit
SHORT CIRCUIT
Protection type : Hiccup mode, recovers automatically after fault condition is removed
WORKING TEMP.
-25 ~ +71
WORKING HUMIDITY
20% ~ 90% RH non-condensing
(Refer to output load derating curve)
-25 ~ +105 , 10 ~ 95% RH
0.03% / (0 ~ 50 )
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
ENVIRONMENT STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
WITHSTAND VOLTAGE
SAFETY & ISOLATION RESISTANCE
OTHERS
60mVp-p
A: 9 ~ 18VDC B: 18 ~ 36VDC C: 36 ~ 72VDC
80%
78%
82%
80%
81%
EFFICIENCY (Typ.)
EMC
21 ~ 210mA
250KHz min.
SWITCHING FREQUENCY
VOLTAGE RANGE
(Note. 5)
33.3 ~ 333mA
2.0%
VOLTAGE ACCURACY
INPUT
42 ~ 420mA
10W
RATED POWER
I/P-O/P:1KVDC
I/P-O/P: 100M Ohms / 500VDC / 25
/ 70% RH
EMI CONDUCTION & RADIATION
EMS IMMUNITY
MTBF
DIMENSION
Compliance to EN55022 Class B, FCC part 15 Class B
Compliance to EN61000-4-2,3,4,5,6,8, light industry level, criteria A
500Khrs min. MIL-HDBK-217F(25 )
WEIGHT
32g
50.8*25.4*11.2mm or 2"*1"*0.44" inch (L*W*H)
Derating Curve
Pin Configuration
Mechanical Specification
Unit: mm
50.8
11.27
4
2
5
2.5
BOTTOM VIEW
10.2 10.2
5.1 10.1
25.4
3
1
1.0
5.8
Pin No.
Output
1
2
3
4
5
+ Vi n
- Vi n
+ Vo u t
COM
- Vo u t
100
LOAD (%)
20.3
2.5
15.3
80
+ 0.2/-0.1
-25
0
25
50 60 71
Ta (
NOTE
100
)
1.All parameters are specified at normal input, rated load, 25 70% RH Ambient.
2.Ripple & noise are measured at 20MHz by using a 12" twisted pair terminated with a 0.1uf & 47uf capacitor.
3.Line regulation is measured from low line to high line at rated load.
4.Load regulation is measured from 10% to 100% rated load.
5.Please prevent the converter from operating in overload or short circuit condition for more than 30 seconds.
File Name:DKE10-SPEC 2008-05-20