MPD B1513ERU B1500eru sery Datasheet

B1500ERU Series
Ultra-Wide Input 15W
Single & Dual Output
DC/DC Converters
Electrical Specifications
Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Key Features:
Input
• 15W Output Power
• 4:1 Input Voltage Range
• 1,500 VDC Isolation
• Compact 1 x 2 Inch Case
• Single & Dual Outputs
• Remote ON/OFF
• Industry Standard Pin-Out
Parameter
Conditions
Input Start Voltage
Typ.
Max.
24 VDC Input
Min.
8.8
9.0
48 VDC Input
17.8
18.0
Units
VDC
␲ (Pi) Filter
Input Filter
Start-Up Time
10
mS
Output
Parameter
Conditions
Min.
Output Voltage Accuracy
Output Voltage Balance
Line Regulation
Load Regulation
Typ.
Max.
Units
±1.0
±2.0
%
Dual Output , Balanced Loads
±0.5
Vin = Min to Max
±0.2
±0.5
%
Iout = 10% to 100%
±0.5
±1.0
%
Cross Regulation
Ripple & Noise (20 MHz) (Note 1)
55
Output Power Protection
120
Transient Recovery Time (Note 2)
Transient Response Deviation
25% Load Step Change
Temperature Coefficient
Output Short Circuit
%
±5.0
%
75
150
mV P - P
150
%
200
300
µSec
±3.0
±5.0
%
±0.01
±0.02
%/°C
Max.
Units
Continuous (Autorecovery)
General
Parameter
Conditions
Isolation Voltage
Isolation Resistance
Isolation Capacitance
Min.
Typ.
60 Seconds
1,500
VDC
500 VDC
1,000
M⍀
100 kHz, 1V
Switching Frequency
1,000
pF
300
kHz
Environmental
Parameter
Conditions
Operating Temperature Range
Ambient
Storage Temperature Range
Min.
Typ.
Max.
Units
-40
+25
+85
°C
+105
°C
-55
Cooling
Free Air Convection (See Curves on Page 2)
Humidity
RH, Non-condensing
RFI
95
%
Six-Side Shielded Metal Case
Physical
MicroPower Direct
Case Size
292 Page Street
Suite D
Stoughton, MA 02072
USA
Case Material
2.0 x 1.0 x 0.43 Inches (50.8 x 25.4 x 11.0 mm)
Metal with Non-Conductive Base
Weight
1.13 Oz (32g)
Reliability Specifications
Parameter
T: (781) 344-8226
F: (781) 344-8481
E: [email protected]
W: www.micropowerdirect.com
Conditions
MTBF
MIL HDBK 217F, 25°C, Gnd Benign
Min.
Typ.
Max.
700
Units
kHours
Absolute Maximum Ratings
Parameter
Conditions
Input Voltage Surge (1 Sec)
Lead Temperature
Min.
Typ.
Max.
24 VDC Input
-0.7
50.0
48 VDC Input
-0.7
100.0
1.5 mm From Case For 10 Sec
300.0
Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings.
www.micropowerdirect.com
Units
VDC
°C
www.micropowerdirect.com
Model Selection Guide
Input
Model
Number
Voltage (VDC)
Nominal
Range
24
24
24
24
24
24
24
48
48
48
48
48
48
48
9.0 - 36.0
9.0 - 36.0
9.0 - 36.0
9.0 - 36.0
9.0 - 36.0
9.0 - 36.0
9.0 - 36.0
18.0 - 75.0
18.0 - 75.0
18.0 - 75.0
18.0 - 75.0
18.0 - 75.0
18.0 - 75.0
18.0 - 75.0
B1501ERU
B1502ERU
B1503ERU
B1504ERU
B1505ERU
B1506ERU
B1507ERU
B1511ERU
B1512ERU
B1513ERU
B1514ERU
B1515ERU
B1516ERU
B1517ERU
Output
Reflected
Ripple
Current
Current Voltage Current
Full-Load No-Load (mA, Typ) (VDC) (mA, Max) (mA, Min)
Current (mA)
528
762
744
744
762
735
735
264
381
372
372
381
368
368
25
25
25
25
25
25
25
15
15
15
15
15
15
15
40
40
40
40
40
40
40
30
30
30
30
30
30
30
3.3
5.0
12.0
15.0
±5.0
±12.0
±15.0
3.3
5.0
12.0
15.0
±5.0
±12.0
±15.0
4,000
3,000
1,250
1,000
±1,500
±625
±500
4,000
3,000
1,250
1,000
±1,500
±625
±500
400.0
300.0
125.0
100.0
±150.0
±62.5
±50.0
400.0
300.0
125.0
100.0
±150.0
±62.5
±50.0
Efficiency
(%, Typ)
Capacitive
Load
(µF Max)
Fuse Rating
Slow-Blow
(mA)
78
82
84
84
82
85
85
78
82
84
84
82
85
85
10,200
4,020
1,035
705
±1,020
±495
±165
10,200
4,020
1,035
705
±1,020
±495
±165
2,500
2,500
2,500
2,500
2,500
2,500
2,500
1,250
1,250
1,250
1,250
1,250
1,250
1,250
Derating Curve
Notes:
1. When measuring output ripple, it is recommended that an external 4.7 µF ceramic capacitor
be placed from the +Vout pin to the -Vout pin for single output units and from each output to
common for dual output units.
2. These converters are specified for operation without external components. However, in some
applications the addition of input/ouput capacitors will enhance stability and reduce output
ripple. Recommended capacitor values are 100 µF for CIN and 100 - 220 µF for COUT.
3. Transient recovery is measured to within a 1% error band for a load step change of 75% to
100%.
4. The maximum control current at the on/off pin (pin 6) during a logic high is 50 µA. The maximum
control current to the on/off pin at logic low (-0.7V to 0.8V) is 1 mA. If the on/off pin is left open,
the unit operates. If it is grounded, the unit will shut off.
5. Operation at no-load will not damage these units. However, they may not meet all specifications.
6. Dual output units may be connected to provide a 10 VDC, 24 VDC or 30 VDC output. To do this,
connect the load across the positive (+Vout) and negative (-Vout) outputs and float the output
common.
7. It is recommended that a fuse be used on the input of a power supply for protection. See the
table above for the correct rating.
Remote ON/OFF
Parameter
Min
Max
Units
Supply On
3.5 12.0 or Open VDC
Supply Off
Grnd
1.2
VDC
Control Common Referenced to Gnd
Mechanical Dimensions
Remote ON/OFF Notes:
1. Maximum sink current at the on/off pin (pin 6) during a logic
low is 100 µA.
2. Maximum allowable leakage current of a switch connected to
the on/off terminal (Pin 6) at logic high (2.5V to 100V) is 5 µA.
External Trim
A simple external circuit may be used to
adjust the converter output (single output
models only). To adjust the output DOWN,
connect a 5%, 3W resistor between the
plus output pin and the Vout trim pin. To
adjust the output UP, connect a 5%, 3W
resistor between the minus utput pin and
the Vout trim pin.
For UP/Down trimming capability, connect
a 10 kW potentiometer between the plus
and minus outputs with the wiper arm
connected to the Vout trim pin.
The trim range is ±10%.
Pin Connections
Pin Single
1
+Vin
2
-Vin
3
+Vout
Dual
+Vin
-Vin
+Vout
Pin Single
Dual
4
Trim
Comm.
5
-Vout
-Vout
6 ON/OFF ON/OFF
MicroPower Direct
Mechanical Notes:
• All dimensions are typical in inches (mm)
• Tolerance x.xx = ±0.01 (±0.25)
We Power Your Success - For Less!
292 Page Street Ste D Stoughton, MA 02072
•
TEL: (781) 344-8226
•
FAX: (781) 344-8481
•
E-Mail: [email protected]