VISHAY CRCW1206-HP

CRCW-HP e3
www.vishay.com
Vishay Draloric
Pulse Proof, High Power Thick Film Chip Resistors
FEATURES
•
•
•
•
•
Excellent pulse load capability
Enhanced power rating
Double side printed resistor element
Protective overglaze
Pure tin solder contacts on Ni barrier layer
provides compatibility with lead (Pb)-free and
lead containing soldering processes
• AEC-Q200 qualified, rev. C compliant
• Material categorization: For definitions of compliance
please see www.vishay.com/doc?99912
STANDARD ELECTRICAL SPECIFICATIONS
MODEL
CASE
CASE
SIZE
SIZE
INCH METRIC
CRCW0402-HP e3
0402
RR1005
CRCW0603-HP e3
0603
RR1608
CRCW0805-HP e3
0805
RR2012
CRCW1206-HP e3
1206
RR3216
CRCW1210-HP e3
1210
RR3225
CRCW1218-HP e3
1218
RR3246
CRCW2010-HP e3
2010
RR5025
CRCW2512-HP e3
2512
RR6332
POWER RATING
P70
W
LIMITING
ELEMENT
VOLTAGE
Umax. AC/DC
TEMPERATURE
COEFFICIENT
ppm/K
TOLERANCE
%
RESISTANCE
RANGE

SERIES
± 0.5, ± 1
±5
1 to 1M
E24; E96
E24
± 0.5, ± 1
±5
1 to 1M
E24; E96
E24
± 0.5, ± 1
±5
1 to 1M
E24; E96
E24
± 0.5, ± 1
±5
1 to 1M
E24; E96
E24
± 0.5, ± 1
±5
1 to 1M
E24; E96
E24
± 0.5, ± 1
±5
1 to 1M
E24; E96
E24
± 0.5, ± 1
±5
1 to 1M
E24; E96
E24
± 0.5, ± 1
±5
1 to 1M
E24; E96
E24
± 100
± 200
Zero-Ohm-Resistor: Rmax. = 0.010 , Imax. = 3 A
± 100
0.25
75
± 200
Zero-Ohm-Resistor: Rmax. = 0.008 , Imax. = 5 A
± 100
0.33
150
± 200
Zero-Ohm-Resistor: Rmax. = 0.005 , Imax. = 6 A
± 100
0.5
200
± 200
Zero-Ohm-Resistor: Rmax. = 0.005 , Imax. = 10 A
± 100
0.75
200
± 200
Zero-Ohm-Resistor: Rmax. = 0.004 , Imax. = 12 A
± 100
1.5
200
± 200
Zero-Ohm-Resistor: Rmax. = 0.004 , Imax. = 20 A
± 100
1.0
400
± 200
Zero-Ohm-Resistor: Rmax. = 0.005 , Imax. = 12 A
± 100
1.5
500
± 200
Zero-Ohm-Resistor: Rmax. = 0.005 , Imax. = 16 A
0.125 (1)
50
Notes
• These resistors do not feature a limited lifetime when operated within the permissible limits. However, resistance value drift increasing over
operating time may result in exceeding a limit acceptable to the specific application, thereby establishing a functional lifetime.
• Marking: See document “Surface Mount Resistor Marking” (document number 20020).
• Power rating depends on the max. temperature at the solder point, the component placement density and the substrate material.
(1) CRCW0402-HP resistors feature a single side printed resistive layer only.
TECHNICAL SPECIFICATIONS
PARAMETER
UNIT
CRCW
CRCW
CRCW
CRCW
CRCW
CRCW
CRCW
CRCW
0402-HP 0603-HP 0805-HP 1206-HP 1210-HP 1218-HP 2010-HP 2512-HP
Rated dissipation P70 (2)
W
0.125
0.25
0.33
0.5
0.75
1.5
1.0
1.5
Limiting element voltage Umax. AC/DC
V
50
75
150
200
200
200
400
500
Insulation voltage Uins. (1 min)
V
> 75
> 100
> 200
> 300
> 300
> 300
> 300
> 300
Insulation resistance

31
25.5
42
Category temperature range
°C
Weight
mg
> 109
- 55 to + 155
0.65
2
5.5
10
18
Note
(2) The power dissipation on the resistors generates a temperature rise against the local ambient, depending on the heat flow support of the
printed-circuit board (thermal resistance). The rated dissipation applies only if the permitted film temperature of 155 °C is not exceeded.
Revision: 21-Mar-13
Document Number: 20043
1
For technical questions, contact: [email protected]
THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT
ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000
CRCW-HP e3
www.vishay.com
Vishay Draloric
PART NUMBER AND PRODUCT DESCRIPTION
Part Number: CRCW0603562RFKEAHP (1)
C
R
C
W
MODEL/SIZE
CRCW0402
CRCW0603
CRCW0805
CRCW1206
CRCW1210
CRCW1218
CRCW2010
CRCW2512
0
6
0
3
VALUE
R = Decimal
K = Thousand
M = Million
0000 = Jumper
5
6
2
TOLERANCE
D = ± 0.5 %
F=±1%
J=±5%
Z = Jumper
R
F
K
E
A
H
P
TCR
K = ± 100 ppm/K
N = ± 200 ppm/K
0 = Jumper
PACKAGING
EA
EB
EC
ED
EE
EF
EG
EH
EK
SPECIAL
Up to 2 digits
HP = Pulse proof,
high power
Product Description: CRCW0603-HP 100 562R 1 % ET1 e3
CRCW0603-HP
100
562R
1%
ET1
e3
MODEL
CRCW0402-HP
CRCW0603-HP
CRCW0805-HP
CRCW1206-HP
CRCW1210-HP
CRCW1218-HP
CRCW2010-HP
CRCW2512-HP
TCR
± 100 ppm/K
± 200 ppm/K
RESISTANCE VALUE
10R = 10 
562R = 562 
10K = 10 k
1M = 1 M
0R0 = Jumper
TOLERANCE
± 0.5 %
±1%
±5%
PACKAGING
ET1
ET5
ET6
ET7
EF4
EG1
E02
E67
E82
ET9
LEAD (Pb)-FREE
e3 = Pure tin
termination
finish
Note
(1) Preferred way for ordering products is by use of the PART NUMBER.
PACKAGING
MODEL
PAPER TAPE ON REEL
ACC. TO IEC 60286-3, TYPE I
UNIT
BLISTER TAPE ON REEL
ACC. TO IEC 60286-3, TYPE II
QUANTITY PART NUMBER PRODUCT DESC. QUANTITY PART NUMBER PRODUCT DESC.
10 000
50 000
ED
EE
ET7
EF4
180 mm/7"
CRCW0603-HP 285 mm/11.25"
330 mm/13"
5000
10 000
20 000
EA
EB
EC
ET1
ET5
ET6
180 mm/7"
CRCW0805-HP 285 mm/11.25"
330 mm/13"
5000
10 000
20 000
EA
EB
EC
ET1
ET5
ET6
180 mm/7"
CRCW1206-HP 285 mm/11.25"
330 mm/13"
5000
10 000
20 000
EA
EB
EC
ET1
ET5
ET6
180 mm/7"
CRCW1210-HP 285 mm/11.25"
330 mm/13"
5000
10 000
20 000
EA
EB
EC
ET1
ET5
ET6
CRCW0402-HP
180 mm/7"
330 mm/13"
CRCW1218-HP
180 mm/7"
4000
EK
ET9
CRCW2010-HP
180 mm/7"
4000
EF
E02
CRCW2512-HP
180 mm/7"
2000
4000
EG
EH
E67
E82
Revision: 21-Mar-13
Document Number: 20043
2
For technical questions, contact: [email protected]
THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT
ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000
CRCW-HP e3
www.vishay.com
Vishay Draloric
DIMENSIONS in millimeters
b
l
a
SIZE
SOLDER PAD DIMENSIONS
DIMENSIONS
REFLOW SOLDERING
WAVE SOLDERING
INCH
METRIC
L
W
H
T1
T2
a
b
l
0402
1005
1.0 ± 0.05
0.5 ± 0.05
0.3 ± 0.1
0.25 ± 0.1
0.2 ± 0.1
0.4
0.6
0.5
a
b
l
0603
1608
1.6 ± 0.1
0.85 ± 0.1
0.45 ± 0.1
0.3 ± 0.2
0.3 ± 0.2
0.5
0.9
1.0
0.9
0.9
1.0
0805
2012
2.0 ± 0.15
1.25 ± 0.15
0.50 ± 0.1
0.4 ± 0.2
0.35 ± 0.2
0.7
1.3
1.2
0.9
1.3
1.3
1206
3216
3.1 ± 0.2
1.6 ± 0.15
0.50 ± 0.15
0.5 ± 0.2
0.45 ± 0.2
0.9
1.7
2.0
1.1
1.7
2.3
1210
3225
3.2 ± 0.2
2.5 ± 0.2
0.6 ± 0.1
0.45 ± 0.2
0.4 ± 0.2
0.9
2.5
2.0
1.1
2.5
2.2
1218
3246
3.1 ± 0.2
4.6 ± 0.2
0.6 ± 0.1
0.45 ± 0.2
0.4 ± 0.2
1.05
4.9
1.9
1.25
4.8
1.9
2010
5025
5.0 ± 0.15
2.5 ± 0.15
0.6 ± 0.1
0.6 ± 0.2
0.6 ± 0.2
1.0
2.5
3.9
1.2
2.5
3.9
2512
6332
6.3 ± 0.2
3.15 ± 0.15
0.6 ± 0.1
0.6 ± 0.2
0.6 ± 0.2
1.0
3.2
5.2
1.2
3.2
5.2
FUNCTIONAL PERFORMANCE
Pulse Load Pmax. (W)
Single Pulse
10 000
2512
1218
2010
1210
1206
0805
0603
0402
1000
100
10
1
0.1
0.01
0.000001 0.00001 0.0001
0.001
0.01
0.1
1
10
100
Pulse Duration ti (s)
Maximum pulse load, single pulse; applicable if P  0 and n < 1000 and Û  Ûmax.;
for permissible resistance change equivalent to 8000 h operation
Revision: 21-Mar-13
Document Number: 20043
3
For technical questions, contact: [email protected]
THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT
ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000
CRCW-HP e3
www.vishay.com
Vishay Draloric
Continuous Pulse Load Pmax. (W)
Continuous Pulse
10 000
2512
1218
2010
1210
1206
0805
0603
0402
1000
100
10
1
0.1
0.01
0.000001 0.00001 0.0001
0.001
0.01
0.1
1
10
100
Pulse Duration ti (s)
Maximum pulse load, continuous pulses; applicable if P P (amb) and Û  Ûmax.;
for permissible resistance change equivalent to 8000 h operation
Pulse Voltage Ûmax. (V)
Pulse Voltage
2000
1800
2512
1600
1400
2010
1200
1000
800
1206/1210/1218
600
400
0805
0603
200
0402
0
0.000001 0.00001
0.0001
0.001
0.01
0.1
1
10
Pulse Duration ti (s)
Maximum pulse voltage, single and continuous pulses; applicable if Pˆ  Pˆ max . ;
for permissible resistance change equivalent to 8000 h operation
Fraction of Rated Dissipation in %
DERATING
120
100
80
60
40
20
0
- 55
Revision: 21-Mar-13
- 25
0
25
50
75
70
100
125
155 175
Ambient Temperature in °C
Document Number: 20043
4
For technical questions, contact: [email protected]
THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT
ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000
CRCW-HP e3
www.vishay.com
Vishay Draloric
TEST PROCEDURES AND REQUIREMENTS
EN
60115-1
CLAUSE
IEC
60068-2
TEST
METHOD
TEST
PROCEDURE
STABILITY CLASS 2 OR BETTER
Stability for product types:
CRCW-HP e3
4.5
-
Resistance
-
4.7
-
Voltage proof
U = 1.4 x Uins; 60 s
4.13
-
REQUIREMENTS PERMISSIBLE
CHANGE (R)
Short time overload
U = 2.5 x
1  to 1 M
± 0.5 %, ± 1 %, ± 5 %
P 70 x R
 2 × Umax.; duration: According to style
± (0.5 % R + 0.05 )
Solder bath method; Sn60Pb40;
non-activated flux; (235 ± 5) °C; (2 ± 0.2) s
Good tinning ( 95 % covered)
no visible damage
Solder bath method; Sn96.5Ag3Cu0.5;
non-activated flux; (245 ± 5) °C; (3 ± 0.3) s
Good tinning ( 95 % covered)
no visible damage
4.17.2
58 (Td)
Solderability
4.8.4.2
-
Temperature coefficient
(20/- 55/20) °C and (20/125/20) °C
± 100 ppm/K, ± 200 ppm/K
No visible damage
4.32
21 (UU3)
Shear (adhesion)
RR 1608 and smaller: 9 N
RR 2012 and larger: 45 N
4.33
21 (UU1)
Substrate bending
Depth 2 mm; 3 times
No visible damage,
no open circuit in bent position
± (0.25 % R + 0.05 )
4.19
14 (Na)
Rapid change of temperature
30 min. at - 55 °C; 30 min at 125 °C
5 cycles
1000 cycles
± (0.5 % R + 0.05 )
± (1 % R + 0.05 )
-
Dry heat
-
4.23.2
4.23
2 (Ba)
Damp heat, cyclic
125 °C; 16 h
55 °C;  90 % RH; 24 h; 1 cycle
4.23.3
30 (Db)
cold
4.23.4
1 (Aa)
Low air pressure
- 55 °C; 2 h
4.23.5
13 (M)
-
1 kPa; (25 ± 10) °C; 1 h
4.23.6
30 (Db)
Damp heat, cyclic
55 °C;  90 % RH; 24 h; 5 cycle
4.23.7
-
D.C. load
4.25.1
-
Endurance at 70 °C
4.18.2
U =
U =
± (2 % R + 0.1 )
P 70 x R
P 70 x R  U max.
1.5 h on; 0.5 h off;
70 °C; 1000 h
70 °C; 8000 h
± (2 % R + 0.1 )
± (4 % R + 0.1 )
58 (Td)
Resistance to soldering heat
Solder bath method; (260 ± 5) °C; (10 ± 1) s
± (0.5 % R + 0.05 )
4.35
-
Flammability, needle flame test
IEC 60695-15-5; 10 s
No burning after 30 s
4.24
78 (Cab)
Damp heat, steady state
(40 ± 2) °C; (93 ± 3) % RH; 56 days
± (1 % R + 0.05 )
4.25.3
-
Endurance at
upper category temperature
155 °C; 1000 h
± (2 % R + 0.1 )
4.40
-
Electrostatic discharge
(human body model)
IEC 61340-3-1; 3 positive and 3 negative
discharges; ESD voltage according to size
± (1 % R + 0.05 )
4.29
45 (XA)
Component solvent resistance
Isopropyl alcohol; 50 °C; method 2
No visible damage
Marking legible,
no visible damage
± (0.5 % R + 0.05 )
4.30
45 (XA)
Solvent resistance of marking
Isopropyl alcohol; 50 °C; method 1;
toothbrush
4.22
6 (Fc)
Vibration, endurance by sweeping
f = 10 Hz to 2000 Hz; x, y, z  1.5 mm;
A  200 m/s2; 10 sweeps per axis
4.37
-
Periodic electric overload
4.27
-
Single pulse high voltage overload,
10 μs/700 μs
U =
15 x P 70 x R  2 x U max.
0.1 s “ON”; 2.5 s “OFF”; 1000 cycles
Û = 10 x
P 70 x R  2 x U max.
10 pulses
± (1 % R + 0.05 )
± (1 % R + 0.05 )
All tests are carried out in accordance with the following specifications:
• EN 60115-1, generic specification
• EN 140400, sectional specification
• EN 140401-802, detail specification
• IEC 60068-2, environmental test procedures
Packaging of components is done in paper or blister tapes according to IEC 60286-3.
Revision: 21-Mar-13
Document Number: 20043
5
For technical questions, contact: [email protected]
THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT
ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000
Legal Disclaimer Notice
www.vishay.com
Vishay
Disclaimer
ALL PRODUCT, PRODUCT SPECIFICATIONS AND DATA ARE SUBJECT TO CHANGE WITHOUT NOTICE TO IMPROVE
RELIABILITY, FUNCTION OR DESIGN OR OTHERWISE.
Vishay Intertechnology, Inc., its affiliates, agents, and employees, and all persons acting on its or their behalf (collectively,
“Vishay”), disclaim any and all liability for any errors, inaccuracies or incompleteness contained in any datasheet or in any other
disclosure relating to any product.
Vishay makes no warranty, representation or guarantee regarding the suitability of the products for any particular purpose or
the continuing production of any product. To the maximum extent permitted by applicable law, Vishay disclaims (i) any and all
liability arising out of the application or use of any product, (ii) any and all liability, including without limitation special,
consequential or incidental damages, and (iii) any and all implied warranties, including warranties of fitness for particular
purpose, non-infringement and merchantability.
Statements regarding the suitability of products for certain types of applications are based on Vishay’s knowledge of typical
requirements that are often placed on Vishay products in generic applications. Such statements are not binding statements
about the suitability of products for a particular application. It is the customer’s responsibility to validate that a particular
product with the properties described in the product specification is suitable for use in a particular application. Parameters
provided in datasheets and/or specifications may vary in different applications and performance may vary over time. All
operating parameters, including typical parameters, must be validated for each customer application by the customer’s
technical experts. Product specifications do not expand or otherwise modify Vishay’s terms and conditions of purchase,
including but not limited to the warranty expressed therein.
Except as expressly indicated in writing, Vishay products are not designed for use in medical, life-saving, or life-sustaining
applications or for any other application in which the failure of the Vishay product could result in personal injury or death.
Customers using or selling Vishay products not expressly indicated for use in such applications do so at their own risk. Please
contact authorized Vishay personnel to obtain written terms and conditions regarding products designed for such applications.
No license, express or implied, by estoppel or otherwise, to any intellectual property rights is granted by this document or by
any conduct of Vishay. Product names and markings noted herein may be trademarks of their respective owners.
Material Category Policy
Vishay Intertechnology, Inc. hereby certifies that all its products that are identified as RoHS-Compliant fulfill the
definitions and restrictions defined under Directive 2011/65/EU of The European Parliament and of the Council
of June 8, 2011 on the restriction of the use of certain hazardous substances in electrical and electronic equipment
(EEE) - recast, unless otherwise specified as non-compliant.
Please note that some Vishay documentation may still make reference to RoHS Directive 2002/95/EC. We confirm that
all the products identified as being compliant to Directive 2002/95/EC conform to Directive 2011/65/EU.
Vishay Intertechnology, Inc. hereby certifies that all its products that are identified as Halogen-Free follow Halogen-Free
requirements as per JEDEC JS709A standards. Please note that some Vishay documentation may still make reference
to the IEC 61249-2-21 definition. We confirm that all the products identified as being compliant to IEC 61249-2-21
conform to JEDEC JS709A standards.
Revision: 02-Oct-12
1
Document Number: 91000