MPD A501RW Wide input range, 5w single & dual output dc/dc converter Datasheet

A500RW Series
Wide Input Range, 5W
Single & Dual Output
DC/DC Converters
Electrical Specifications
Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Key Features:
• 5W Output Power
• UL Approved (File E245422)
• 2:1 Input Voltage Range
• 1,500 VDC Isolation
• Meets EN55022 Class “A”
• Compact DIP Case
• Single & Dual Outputs
• 1.0 MH MTBF
• Industry Standard Pin-Out
RoHS Compliant
Input
Parameter
Input Start Voltage
Input Filter
Reverse Polarity Input Current
Short Circuit Input Power
Conditions
Min.
Typ.
Max.
5 VDC Input
3.0
3.5
4.4
12 VDC Input
4.5
6.0
8.0
24 VDC Input
8.0
12.0
16.0
48 VDC Input 16.0
24.0
32.0
π (Pi) Filter (Complies with EN55022 Class “A”)
1.0
1,000 3,000
Units
VDC
A
mW
Output
Parameter
Output Voltage Accuracy
Output Voltage Balance
Line Regulation
Load Regulation
Ripple & Noise (20 MHz) (Note 1)
Ripple & Noise (20 MHz)
Ripple & Noise (20 MHz)
Output Power Protection
Transient Recovery Time (Note 2)
Transient Response Deviation
Temperature Coefficient
Output Short Circuit
Conditions
Min.
Dual Output , Balanced Loads
Vin = Min to Max
Iout = 20% to 100%
Typ.
±0.5
±0.5
±0.1
±0.3
50
Max.
±1.0
±2.0
±0.3
±1.0
75
100
15
150
±2.0
±0.01
300
±6.0
±0.02
Typ.
Max.
380
300
500
Over Line, Load & Temp.
120
25% Load Step Change
Units
%
%
%
%
mV P - P
mV P - P
mV rms
%
μSec
%
%/ºC
Continuous
General
Parameter
Isolation Voltage
Isolation Resistance
Isolation Capacitance
Switching Frequency
Conditions
60 Seconds
500 VDC
100 kHz, 1V
Min.
1,500
1,000
Units
VDC
MΩ
pF
kHz
Environmental
MicroPower Direct
292 Page Street
Suite D
Stoughton, MA 02072
USA
T: (781) 344-8226
F: (781) 344-8481
E: [email protected]
W: www.micropowerdirect.com
Parameter
Operating Temperature Range
Operating Temperature Range
Storage Temperature Range
Cooling
Humidity
RFI
Conducted EMI
Conditions
Min.
Typ.
-40
+25
-40
-40
Free Air Convection
RH, Non-condensing
Six-Side Shielded Metal Case
EN55022 Class “A”
Ambient
Case
Max.
+71
+90
+125
Units
ºC
ºC
ºC
95
%
Physical
Case Size
Case Material
Weight
1.25 x 0.80 x 0.40 Inches (31.8 x 20.3 x 10.2 mm)
Metal with Non-Conductive Base (UL94-V0)
0.42 Oz (12g)
Reliability Specifications
Parameter
MTBF
Safety Standards
Safety Approvals
Conditions
Min.
Typ.
MIL HDBK 217F, 25ºC, Gnd Benign
1.0
UL 1950, EN 60950, IEC 60950
UL, cUL; File No. E245422
Max.
Units
MHours
Max.
10.0
25.0
50.0
100.0
260
2,500
Units
Absolute Maximum Ratings
Parameter
Input Voltage Surge (1 Sec)
Lead Temperature
Internal Power Dissipation
Conditions
5 VDC Input
12 VDC Input
24 VDC Input
48 VDC Input
1.5 mm From Case For 10 Sec
All Models
Min.
-0.7
-0.7
-0.7
-0.7
Typ.
VDC
ºC
mW
Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings.
Model Selection Guide
Model
Number
Input
Current (mA)
Voltage (VDC)
Nominal
Range
Full-Load
12
12
12
12
12
12
12
24
24
24
24
24
24
24
48
48
48
48
48
48
48
5
5
5
5
5
5
5
9.0 - 18.0
9.0 - 18.0
9.0 - 18.0
9.0 - 18.0
9.0 - 18.0
9.0 - 18.0
9.0 - 18.0
18.0 - 36.0
18.0 - 36.0
18.0 - 36.0
18.0 - 36.0
18.0 - 36.0
18.0 - 36.0
18.0 - 36.0
36.0 - 75.0
36.0 - 75.0
36.0 - 75.0
36.0 - 75.0
36.0 - 75.0
36.0 - 75.0
36.0 - 75.0
4.5 - 7.0
4.5 - 7.0
4.5 - 7.0
4.5 - 7.0
4.5 - 7.0
4.5 - 7.0
4.5 - 7.0
429
514
595
595
514
595
595
209
251
291
291
251
291
291
104
126
145
145
126
145
145
1,056
1,265
1,463
1,463
1,265
1,463
1,463
Output
Reflected
Efficiency
Current
Ripple Voltage Current
(%, Typ)
(VDC) (mA, Max) (mA, Min)
No-Load Current
Fuse Rating
Slow-Blow
(mA)
(mA, Typ)
A501RW
A502RW
A503RW
A504RW
A505RW
A506RW
A507RW
A511RW
A512RW
A513RW
A514RW
A515RW
A516RW
A517RW
A521RW
A522RW
A523RW
A524RW
A525RW
A526RW
A527RW
A551RW
A552RW
A553RW
A554RW
A555RW
A556RW
A557RW
20
20
20
20
20
20
20
5
5
5
5
5
5
5
3
3
3
3
3
3
3
70
70
70
70
70
70
70
25
25
25
25
25
25
25
15
15
15
15
15
15
15
10
10
10
10
10
10
10
100
100
100
100
100
100
100
3.3
5.0
12.0
15.0
±5.0
±12.0
±15.0
3.3
5.0
12.0
15.0
±5.0
±12.0
±15.0
3.3
5.0
12.0
15.0
±5.0
±12.0
±15.0
3.3
5.0
12.0
15.0
±5.0
±12.0
±15.0
Notes:
1. When measuring output ripple, it is recommended that an external 0.47 μF ceramic capacitor be placed from the +Vout pin to the -Vout pin for single output
units and from each output to common for dual output units. For noise sensitive
applications, the use of 3.3 μF capacitors will reduce the output ripple.
2. Transient recovery is measured to within a 1% error band for a load step change
of 75% to 100%.
3. Operation at no-load will not damage these units. However, they may not meet
all specifications.
4. Dual output units may be connected to provide a 10 VDC, 24 VDC or 30 VDC
output. To do this, connect the load across the positive (+Vout) and negative
(-Vout) outputs and float the output common.
5. The converter should be connected to a low ac-impedance source. An input source
with a highly inductive impedance may affect the stability of the converter. In
applications where the converter output loading is high and input power is supplied over long lines, it may be necessary to use a capacitor on the input to insure
start-up.
In this case, it is recommended that a low ESR (ESR <1.0Ω at 100 kHz) capacitor
be mounted close to the converter. For 5V input units a 10 μF is recommended,
for 12V input units, a 3.3 μF; and for 24V & 48V units a 2.2 μF.
6. It is recommended that a fuse be used on the input of a power supply for protection. See the table above for the correct rating.
1,200.0
1,000.0
500.0
400.0
±500.0
±250.0
±200.0
1,200.0
1,000.0
500.0
400.0
±500.0
±250.0
±200.0
1,200.0
1,000.0
500.0
400.0
±500.0
±250.0
±200.0
1,200.0
1,000.0
500.0
400.0
±500.0
±250.0
±200.0
60.0
50.0
25.0
20.0
±25.0
±12.5
±10.0
60.0
50.0
25.0
20.0
±25.0
±12.5
±10.0
60.0
50.0
25.0
20.0
±25.0
±12.5
±10.0
60.0
50.0
25.0
20.0
±25.0
±12.5
±10.0
77
81
84
84
81
84
84
79
83
86
86
83
86
86
79
83
86
86
83
86
86
75
79
82
82
79
82
82
1,500
1,500
1,500
1,500
1,500
1,500
1,500
700
700
700
700
700
700
700
350
350
350
350
350
350
350
3,000
3,000
3,000
3,000
3,000
3,000
3,000
Derating Curve
Mechanical Dimensions
Pin Connections
Pin
Single
Dual
Pin
Single
Dual
2, 3
9
11
-Vin
No Pin
NC
-Vin
Common
-Vout
14
16
22, 23
+Vout
-Vout
+Vin
+Vout
Common
+Vin
NC: No Connection
Capacitive Load
Single Output
Dual Output
6,800 μF Max
±1,000 μF Max
Mechanical Notes:
• All dimensions are typical in inches (mm)
• Tolerance x.xx = ±0.01 (±0.25)
• Leads are gold plated for improved
solderability.
MicroPower Direct
www.micropowerdirect.com
292 Page Street Ste D Stoughton, MA 02072
•
TEL: (781) 344-8226
•
FAX: (781) 344-8481
•
E-Mail: [email protected]
Similar pages