ETC2 GT3A-6 Analog timer Datasheet

Timers
GT3A
GT3A
Switches & Pilot Lights
GT3A Series — Analog Timers
Key features:
•
•
•
•
•
4 selectable operation modes on each model
External start, reset, and gate inputs
Panel mount or socket mount
Large variety of timing functions
Power and output status indicating LEDs
Signaling Lights
UL, c-UL Listed
File No. E55996
Specifications
GT3A-1
GT3A-2
Operation
GT3A-3
Multi-mode
Time Range
Multi-mode with inputs (11 pins)
100 to 240V AC, 50/60Hz
12V DC
24V AC, 50/60Hz / 24V DC
125V AC/250V AC, 3A;
30V DC, 1A (resistive load)
Contact Ratings
125V AC/250V AC, 5A;
30V DC, 5A (resistive load)
Minimum Applicable Load
5V, 10mA (reference value)
AF20 (100V AC): 85 to 264V AC
AD24: 20.4 to 26.4V AC/21.6 to 26.4V DC
D12: 10.8 to 13.2V DC
Voltage Tolerance
Error
±10% maximum
Reset Time
60msec maximum
Insulation Resistance
100MW minimum
Between power and output terminals: 2,000V AC, 1 minute
Between contacts of different poles: 2,000V AC, 1 minute
Between contacts of the same pole: 750V AC, 1 minute
Dielectric Strength
Delayed SPDT +
instantaneous SPDT
Delayed DPDT
Delayed DPDT
10.8VA
(200V AC, 60Hz)
13.5VA
(200V AC, 60Hz)
14.4VA
(200V AC, 60Hz)
4.7VA (100V AC, 60Hz),
14.4VA (200V AC, 60Hz)
­—
12VDC/1W
24VDC/0.7W
24VAC/1.2VA
12VDC/1.1W
24VDC/0.6W
24VAC/1.3VA
12VDC/0.8W
24VDC/0.6W
24VAC/1.3VA
Shock Resistance
5,000,000 operations minimum
50,000 operations minimum (rated load)
63g
100,000 operations minimum (rated load)
73g
79g
80g
Terminal Blocks
Vibration Resistance
10,000,000 operations minimum
Contactors
Delayed SPDT
Mechanical Life
Weight (approximate)
Timers
±0.2%, ±10 msec (repeat, voltage, temperature)
Setting Error
Electrical LIfe
Relays & Sockets
0.1s to 180 hours
Rated Voltage
Power Consumption
(approximate)
GT3A-4,-5,-6
100m/sec (approximate 10G)
2
Operating extremes: 100m/sec2 (approximate 10G)
Damage limits: 500m/sec2 (approximate 50G)
Operating Temperature
–10 to +50°C
Operating Humidity
45 to 85% RH
Storage Temperature
–30 to +80°C
Housing Color
800-262-IDEC (4332) • USA & Canada
Circuit Breakers
Breakers
Circuit
Gray
843
Timers
Signaling Lights
Switches & Pilot Lights
GT3A
Part Numbers
GT3A-1, -2, -3
Mode Of
Operation
Rated Voltage Code
Time Range
Output
AF20: 100 to 240V AC (50/60Hz)
A: ON-delay 1
B: Interval 1
C: Cycle 1
D: Cycle 3
AF20: 100 to 240V AC (50/60Hz)
D12: 12V DC
AD24: 24V AC (50/60Hz)/24V DC
Contact
Delayed SPDT
0.1 seconds
to 180 hours
250V AC, 3A,
30V DC, 1A
(resistive load)
240V AC, 5A,
24V DC, 5A
(resistive load)
Delayed SPDT +
Instantaneous SPDT
Delayed DPDT
Complete Part No.
8-Pin
11-Pin
GT3A-1AF20
GT3A-1EAF20
GT3A-2AF20
GT3A-2EAF20
GT3A-2D12
GT3A-2ED12
GT3A-2AD24
GT3A-2EAD24
GT3A-3AF20
GT3A-3EAF20
GT3A-3D12
GT3A-3ED12
GT3A-3AD24
GT3A-3EAD24
1. For wiring schematics and timing diagrams for GT3A-1, -2, -3, see pages page 845 and page 846 respectively.
2. For more details about time ranges, see instructions on page page 850.
3. For socket and accessory part numbers, see page 860.
Mode of
Operation
A: ON-Delay 2
B: Cycle 2
C: Signal ON/OFF-Delay 1
D: Signal OFF-Delay 1
A: Interval 2
B: One-Shot Cycle
C: Signal ON/OFF-Delay 2
D: Signal OFF-Delay 2
A: One-Shot
B: One-Shot ON-Delay
C: One-Shot 2
D: Signal ON/OFF-Delay 3
4.
5.
6.
7.
8.
Rated Voltage Code
Time Range
Output
0.1 seconds
to 180 hours
250V AC, 5A,
24V DC, 5A
(resistive load)
AF20: 100 to 240V AC (50/60Hz)
AD24: 24V AC (50/60Hz)/24V DC
For wiring schematics and timing diagrams GT3A-4,-5,-6, see pages 832, 833, and 833 respectively.
For more details about time ranges, see instructions on page 850.
A (11-pin) and B (11-pin) differ in the way inputs are wired.
For socket and accessory part numbers, see page 860.
For the timing diagrams overview, see page 832.
Circuit Breakers
844
Contact
Input
AF20: 100 to 240V AC (50/60Hz)
D12: 12V DC
AD24: 24V AC (50/60Hz)/24V DC
Terminal Blocks
Contactors
Timers
Relays & Sockets
GT3A-4, -5, -6
www.IDEC.com
Delayed
DPDT
Start
Reset
Gate
Complete Part No.
A (11-pin)
B (11-pin)
GT3A-4AF20
GT3A-4EAF20
GT3A-4D12
GT3A-4ED12
GT3A-4AD24
GT3A-4EAD24
GT3A-5AF20
GT3A-5EAF20
GT3A-5AD24
GT3A-5EAD24
GT3A-6AF20
GT3A-6EAF20
GT3A-6AD24
GT3A-6EAD24
Timers
GT3A
Switches & Pilot Lights
Timing Diagrams/Schematics
GT3A-1 Timing Diagrams
Delayed SPDT
Operation
Mode
Selection
MODE
A
Item
Set Time
Power
Delayed
Contact
Terminal Number
Signaling Lights
ON-Delay 1
Operation
T
2 - 7 (8p)
2 - 10 (11p)
5 - 8 (8p)
8 - 11 (11p)
6 - 8 (8p)
9 - 11 (11p)
(NC)
(NO)
POWER
Indicator
Interval 1
MODE
B
Item
Set Time
Power
Delayed
Contact
Terminal Number
Relays & Sockets
OUT
Operation
T
2 - 7 (8p)
2 - 10 (11p)
5 - 8 (8p)
8 - 11 (11p)
6 - 8 (8p)
9 - 11 (11p)
(NC)
(NO)
POWER
Indicator
OUT
MODE
C
Item
Set Time
Power
Delayed
Contact
Terminal Number
2 - 7 (8p)
2 - 10 (11p)
5 - 8 (8p)
8 - 11 (11p)
6 - 8 (8p)
9 - 11 (11p)
Timers
Cycle 1
(OFF first)
Operation
T
T
T
T
(NC)
(NO)
POWER
Indicator
OUT
MODE
D
Item
Set Time
Power
Delayed
Contact
Terminal Number
2 - 7 (8p)
2 - 10 (11p)
5 - 8 (8p)
8 - 11 (11p)
6 - 8 (8p)
9 - 11 (11p)
Contactors
Cycle 3
(ON first)
Operation
(NC)
(NO)
POWER
Indicator
OUT
Terminal Blocks
Circuit Breakers
800-262-IDEC (4332) • USA & Canada
845
Timers
GT3A-3 Timing Diagrams
Delayed DPDT
GT3A-2 Timing Diagrams
Delayed SPDT + Instantaneous SPDT
Operation
Mode
Selection
Operation
Mode
Selection
Signaling Lights
Switches & Pilot Lights
GT3A
ON-Delay 1
MODE
A
Item
Set Time
Power
Delayed
Contact
Instantaneous
Contact
Terminal Number
Operation
T
2 - 7 (8p)
2 - 10 (11p)
5 - 8 (8p)
8 - 11 (11p)
6 - 8 (8p)
9 - 11 (11p)
(NC)
1-4
(NC)
1-3
(NO)
ON-Delay 1
MODE
A
(NO)
Item
Set Time
Power
Delayed
Contact
Terminal Number
Operation
T
2 - 7 (8p)
2 - 10 (11p)
1 -4, 5 - 8 (8p)
(NC)
1 -4, 8 - 11 (11p)
1 -3, 6 - 8 (8p)
(NO)
1 -3, 9 - 11 (11p)
POWER
Indicator
OUT
POWER
Relays & Sockets
Indicator
OUT
Interval 1
MODE
B
Item
Set Time
Power
Delayed
Contact
Instantaneous
Contact
Interval 1
Terminal Number
Operation
T
2 - 7 (8p)
2 - 10 (11p)
5 - 8 (8p)
8 - 11 (11p)
6 - 8 (8p)
9 - 11 (11p)
(NC)
1-4
(NC)
1-3
(NO)
B
OUT
Cycle 1
(OFF first)
MODE
C
MODE
Contactors
C
Power
Delayed
Contact
Instantaneous
Contact
Terminal Number
Item
Set Time
Power
Delayed
Contact
Operation
T
Terminal Number
(NC)
1-4
(NC)
1-3
(NO)
(NO)
Cycle 3
(ON first)
MODE
D
Item
Set Time
Power
Delayed
Contact
2 - 7 (8p)
2 - 10 (11p)
1 -4, 5 - 8 (8p)
(NC)
1 -4, 8 - 11 (11p)
1 -3, 6 - 8 (8p)
(NO)
1 -3, 9 - 11 (11p)
POWER
Terminal Blocks
D
Delayed
Contact
Instantaneous
Contact
Terminal Number
2 - 7 (8p)
2 - 10 (11p)
5 - 8 (8p)
8 - 11 (11p)
6 - 8 (8p)
9 - 11 (11p)
(NC)
1-4
(NC)
1-3
(NO)
OUT
Operation
T
T
(NO)
POWER
Indicator
OUT
Circuit Breakers
Note: Pins 1, 3, and 4 are the instantaneous contacts.
846
T
Terminal Number
Indicator
MODE
T
OUT
OUT
Power
T
POWER
T
Indicator
Item
Set Time
Operation
T
2 - 7 (8p)
2 - 10 (11p)
1 -4, 5 - 8 (8p)
(NC)
1 -4, 8 - 11 (11p)
1 -3, 6 - 8 (8p)
(NO)
1 -3, 9 - 11 (11p)
Indicator
2 - 7 (8p)
2 - 10 (11p)
5 - 8 (8p)
8 - 11 (11p)
6 - 8 (8p)
9 - 11 (11p)
POWER
Cycle 3
(ON first)
Operation
T
POWER
OUT
Item
Set Time
Delayed
Contact
Terminal Number
2 - 7 (8p)
2 - 10 (11p)
1 -4, 5 - 8 (8p)
(NC)
1 -4, 8 - 11 (11p)
1 -3, 6 - 8 (8p)
(NO)
1 -3, 9 - 11 (11p)
Indicator
Indicator
Cycle 1
(OFF first)
Power
(NO)
POWER
Timers
MODE
Item
Set Time
www.IDEC.com
Operation
Timers
GT3A
Switches & Pilot Lights
GT3A-4 Timing Diagrams
Delayed DPDT
Operation
Mode Selection
ON-Delay 2
MODE
2 - 6 (A)
5 - 7 (B)
2 - 7 (A)
6 - 7 (B)
Start
Input
Operation
2 - 10 POWER
Reset
Gate
2 - 5 (A)
1-4
8 - 11
1-3
9 - 11
Delayed
Contact
ON or L
ON or L
ON or L
(NC)
Relays & Sockets
A
Terminal Number
Signaling Lights
Item
Power
(NO)
POWER
Indicator
OUT
Set Time
T
Item
Power
Cycle 2
Terminal Number
T"
Operation
2 - 6 (A)
5 - 7 (B)
2 - 7 (A)
6 - 7 (B)
Reset
Gate
2 - 5 (A)
1-4
8 - 11
1-3
9 - 11
Delayed
Contact
ON or L
ON or L
ON or L
Timers
B
Input
T'
2 - 10 POWER
Start
MODE
Ta
(NC)
(NO)
POWER
Indicator
OUT
Set Time
T
Item
Signal ON/OFF-Delay 1
MODE
C
T
T
T
T
Ta
T
Terminal Number
T
T
T"
T"
T
T
T
T
T
Operation
2 - 10 POWER
2 - 6 (A)
5 - 7 (B)
2 - 7 (A)
6 - 7 (B)
Start
Input
T
Reset
Gate
2 - 5 (A)
1-4
8 - 11
1-3
9 - 11
Delayed
Contact
Contactors
Power
T
ON or L
ON or L
ON or L
(NC)
(NO)
POWER
Indicator
T
Item
Power
Signal OFF-Delay 1
MODE
D
Ta
T
Ta
Terminal Number
T
T
T
T"
Ta
Operation
2 - 10 POWER
Start
Input
T
Terminal Blocks
OUT
Set Time
Reset
Gate
2 - 6 (A)
5 - 7 (B)
2 - 7 (A)
6 - 7 (B)
2 - 5 (A)
Delayed
Contact
ON or L
ON or L
(NC)
(NO)
Circuit Breakers
1-4
8 - 11
1-3
9 - 11
ON or L
POWER
Indicator
OUT
Set Time
T
Ta
Ta
T
T
T
T = Set time Ta = Shorter than set time
T = T' + T"
800-262-IDEC (4332) • USA & Canada
847
Timers
GT3A-5 Timing Diagrams
Delayed DPDT
Operation
Mode Selection
Signaling Lights
Switches & Pilot Lights
GT3A
Item
Power
Interval 2
2 - 6 (A)
5 - 7 (B)
2 - 7 (A)
6 - 7 (B)
Start
MODE
A
Relays & Sockets
Terminal Number
Input
Operation
2 - 10 POWER
Reset
Gate
2 - 5 (A)
1-4
8 - 11
1-3
9 - 11
Delayed
Contact
ON or L
ON or L
ON or L
(NC)
(NO)
POWER
Indicator
OUT
Set Time
T
Item
Power
One-Shot Cycle
Timers
MODE
B
T'
Terminal Number
T"
Operation
2 - 10 POWER
2 - 6 (A)
5 - 7 (B)
2 - 7 (A)
6 - 7 (B)
Start
Input
Ta
Reset
Gate
2 - 5 (A)
1-4
8 - 11
1-3
9 - 11
Delayed
Contact
ON or L
ON or L
ON or L
(NC)
(NO)
POWER
Indicator
OUT
Set Time
T
Contactors
Item
Power
Signal ON/OFF-Delay 2
MODE
C
T
Ta
Terminal Number
T'
T"
T
Operation
2 - 10 POWER
2 - 6 (A)
5 - 7 (B)
2 - 7 (A)
6 - 7 (B)
Start
Input
T
Reset
Gate
2 - 5 (A)
1-4
8 - 11
1-3
9 - 11
Delayed
Contact
ON or L
ON or L
ON or L
(NC)
(NO)
POWER
Terminal Blocks
Indicator
OUT
Set Time
T
Item
Power
Signal OFF-Delay 2
MODE
Circuit Breakers
D
Ta
T
Terminal Number
Ta
Ta
T
T'
T"
Operation
2 - 10 POWER
Start
Input
T
Reset
Gate
2 - 6 (A)
5 - 7 (B)
2 - 7 (A)
6 - 7 (B)
2 - 5 (A)
1-4
8 - 11
1-3
9 - 11
Delayed
Contact
ON or L
ON or L
ON or L
(NC)
(NO)
POWER
Indicator
OUT
Set Time
T
Ta
Ta
T = Set time Ta = Shorter than set time
T = T' + T"
848
www.IDEC.com
T
T'
T"
Ta
Timers
GT3A
Switches & Pilot Lights
GT3A-6 Timing Diagrams
Delayed DPDT
Operation
Mode Selection
One-Shot 1
MODE
2 - 6 (A)
5 - 7 (B)
2 - 7 (A)
6 - 7 (B)
Start
Input
Operation
2 - 10 POWER
Reset
Gate
2 - 5 (A)
1-4
8 - 11
1-3
9 - 11
Delayed
Contact
ON or L
ON or L
ON or L
(NC)
Relays & Sockets
A
Terminal Number
Signaling Lights
Item
Power
(NO)
POWER
Indicator
OUT
Set Time
Ta
Item
Power
One-Shot ON-Delay
MODE
Ta
T'
Terminal Number
T"
Operation
2 - 6 (A)
5 - 7 (B)
2 - 7 (A)
6 - 7 (B)
Reset
Gate
2 - 5 (A)
1-4
8 - 11
1-3
9 - 11
Delayed
Contact
ON or L
ON or L
ON or L
Timers
B
T
2 - 10 POWER
Start
Input
Ta
(NC)
(NO)
POWER
Indicator
OUT
Set Time
T
Item
One-Shot 2
MODE
C
T
T
T'
Terminal Number
T"
Operation
2 - 10 POWER
2 - 6 (A)
5 - 7 (B)
2 - 7 (A)
6 - 7 (B)
Start
Input
Ta
Reset
Gate
2 - 5 (A)
1-4
8 - 11
1-3
9 - 11
Delayed
Contact
Contactors
Power
T
ON or L
ON or L
ON or L
(NC)
(NO)
POWER
Indicator
T
Item
Power
Signal ON/OFF-Delay 3
MODE
D
T
T'
Terminal Number
T"
Operation
2 - 10 POWER
Start
Input
Ta
Terminal Blocks
OUT
Set Time
Reset
Gate
2 - 6 (A)
5 - 7 (B)
2 - 7 (A)
6 - 7 (B)
2 - 5 (A)
Delayed
Contact
ON or L
ON or L
(NC)
(NO)
Circuit Breakers
1-4
8 - 11
1-3
9 - 11
ON or L
POWER
Indicator
OUT
Set Time
T
T
Ta
T'
T"
Ta
Ta
T
T = Set time Ta = Shorter than set time
T = T' + T"
800-262-IDEC (4332) • USA & Canada
849
Timers
GT3A
Switches & Pilot Lights
Instructions: Setting GT3A Series Timers
Timed OUT Indicator
POWER Indicator (flashes
during time-delay period)
Signaling Lights
m Setting Knob
j Operator Mode Selector
A, B, C, D
l Time Range Selector
1S, 10S, 10M, 10H
Step 1.
Select the desired mode
of operation.
Circuit Breakers
Terminal Blocks
Contactors
Timers
Relays & Sockets
k Dial Selector
0-1, 0-3, 0-6, 0-18
Step 2.
Select the time range
that contains the desired
time period.
Desired Mode of Operation
For Timers
Mode of Operation
ON-delay 1
GT3A-1
Interval 1
GT3A-2
Cycle 1
GT3A-3
Cycle 3
ON-delay 2
Cycle 2
GT3A-4
Signal ON/OFF-delay 1
Signal OFF-delay 1
Interval 2
One-shot cycle
GT3A-5
Signal ON/OFF-delay 2
Signal OFF-delay 2
One-shot 1
One-shot ON-delay
GT3A-6
One-shot 2
Signal ON/OFF-delay 3
Desired Time Range
Time Ranges
0.1 seconds to 1 second
0.1 seconds to 3 seconds
0.1 seconds to 6 seconds
0.15 seconds to 18 seconds
0.1 seconds to 10 seconds
0.3 seconds to 30 seconds
0.6 seconds to 60 seconds
1.8 seconds to 180 seconds
6 seconds to 10 minutes
18 seconds to 30 minutes
36 seconds to 60 minutes
108 seconds to 180 minutes
6 minutes to 10 hours
18 minutes to 30 hours
36 minutes to 60 hours
108 minutes to 180 hours
Step 3.
Set the precise period of time desired by using the m Setting Knob.
850
Selection
j Operation Mode Selector
A
B
C
D
A
B
C
D
A
B
C
D
A
B
C
D
Selection
k Dial Selector
l Time Range Selector
0-1
0-3
1S
0-6
0-18
0-1
0-3
10S
0-6
0-18
0-1
0-3
10M
0-6
0-18
0-1
0-3
10H
0-6
0-18
Selection
www.IDEC.com
Remarks
The desired operation mode can be selected from
the A, B, C, and D modes using the Operation Mode
Selector. Change the operation mode from A to B, C,
and D in turn by turning the operation mode selector
clockwise using a flat screwdriver which is a maximum
of 0.156” (4mm) wide. The selected mode is displayed
in the window.
Remarks
The desired time range is selected by setting both
k Dial Selector and
l Time Range Selector.
Timers
GT3F
Switches & Pilot Lights
GT3F Series — True Power OFF Delay Timers
Key features:
•
•
•
•
“True” power OFF-delay up to 10 minutes
No external control switch necessary
Available with reset inputs
Mountable in sockets or flush panel
Signaling Lights
UL, c-UL Listed
File No. E55996
Specifications
GT3F-1
Operation
GT3F-2
True power OFF-delay
Time Range
100 to 240V AC, 50/60Hz
24V AC/DC
Rated Voltage
Contact Rating
250V AC/30V DC, 5A
(resistive load)
250V AC/30V DC, 3A
(resistive load)
Contact Form
SPDT
DPDT
Minimum Power Application Time
Voltage Tolerance
1 second
AF20: 100 to 240V AC
AD24: 21.6 to 26.4VDC, 20.4 to 26.4VAC
±0.2%, ±10 msec
Voltage Error
±0.2%, ±10 msec
Temperature Error
±0.2%, ±10 msec
Setting Error
±10% maximum
Insulation Resistance
Timers
Repeat Error
100MW minimum
Power Consumption
AF20: 3.7VA (200V AC, 60Hz)
AD24: 0.8W (DC), 1.2VA (AC)
20,000,000 operations minimum
Electrical Life
100,000 operations minimum
Vibration Resistance
100m/sec2 (approximate 10G)
Operating extremes:
100 m/sec2 (approximate 10G)
Damage limits: 500 m/sec2 (approximate 50G)
Operating Temperature
–10 to +50°C
Storage Temperature
–30 to +80°C
Operating Humidity
45 to 85% RH
Weight (approximate)
Terminal Blocks
Shock Resistance
Contactors
Dielectric Strength
Between power and output terminals:
2,000V AC, 1 minute (SPDT)
1,500V AC, 1 minute (DPDT)
Between contacts on different poles:
1,000V AC, 1 minute (DPDT)
Between contacts of the same pole:
750V AC, 1 minute
Mechanical Life
Relays & Sockets
0.1 seconds to 600 seconds
77g
79g
800-262-IDEC (4332) • USA & Canada
Circuit Breakers
1. An inrush current flows during the minimum power application time. AF20: approximate 0.4A,
AD24: approximate 1.2A
2. GT3F does not read the preset time range shown on the knob after power is turned off. Note that minimizing
the preset time, by turning the knob to zero, does not shorten the delay time after power is removed.
851
Timers
Switches & Pilot Lights
GT3F
Part Numbering List
GT3F
Mode of
Operation
Time Range
AF20: 100 to
240VAC (50/60Hz)
True-Power
OFF-delay
Signaling Lights
Rated
Voltage Code
AD24: 24V AC/DC
Output
Contact
250V AC, 5A,
0.1 seconds to
600 seconds
30V DC, 5A (resistive load)
250V AC, 3A,
30V DC, 3A (resistive load)
Complete Part Number
Optional Input
Delayed SPDT
Reset
Delayed DPDT
None (8p)
Reset (11p)
8-Pin
GT3F-1AF20
GT3F-1EAF20
GT3F-1AD24
GT3F-1EAD24
GT3F-2AF20
GT3F-2EAF20
GT3F-2AD24
GT3F-2EAD24
Optional reset input resets the contact to the OFF state before time out.
Timing Diagrams/Schematics
GT3F-1 Timing Diagrams
GT3F-1 (8-pin)
Relays & Sockets
Timers
Item
Power
Reset
Input
Delayed
Contact
Indicator
Set Time
Terminal Number
2 - 7 (8p)
2 - 10 (11p)
1 - 4 (8p)
ON or L
6 - 7 (11p)
5 - 8 (8p)
1 - 4 (11p)
(NC)
6 - 8 (8p)
1 - 3 (11p)
(NO)
Operation
POWER
Tr
T = Set time
Ta = Shorter than set time
Ts = 1 Second
Tr = Minimum Power Application Time
GT3F-1: 1 Second
T
Ta
Ts
Circuit Breakers
852
T
1. For time ranges, see page page 854.
2. For sockets and accessory part numbers, see page page 860.
3. When power is applied, the NO output contact closes. When power is removed, the timing period
begins. When time has elapsed, the NO contact opens.
4. For the timing diagram overview, see page page 832.
Terminal Blocks
Contactors
GT3F-1E (11-pin)
Delayed SPDT Output, with Reset Input
www.IDEC.com
11-Pin
Timers
GT3F
GT3F-2 (8-pin)
Switches & Pilot Lights
GT3F-2 Timing Diagrams
GT3F-2E (11-pin)
Delayed DPDT Output
(Contact Input)
m n
Reset
j q
POWER
Item
8-Pin Type
Terminal Number
(NC)
(NO)
11-Pin Type
POWER
T
Terminal Number
Tr
T
Operation
2 - 10
6 - 7 (11p)
1-4
8 - 11
1-3
9 - 11
Delayed
Contact
Indicator
Relays & Sockets
1-4
5-8
1-3
6-8
Power
Reset
Input
POWER
Operation
Set Time
Item
POWER
2-7
Delayed
Contact
Indicator
no p
q
m
r
l
s
k
(-)
(+)
j
Reset
o
p (+)
Power
no p
q
m
r
l
s
k
(-)
(+)
j
Signaling Lights
l
(-) k
(Transistor Input)
ON or L
(NC)
(NO)
POWER
Tr
T
Ta
Ts
Timers
Set Time
T
When power is applied, the NO contact closes. When power is removed, the timing period begins. When time has elapsed, the NO contact opens. Optional reset
input will return contacts to original state before time elapses.
Contactors
T = Set time
Ta = Shorter than set time
Ts = 1 Second
Tr = Minimum Power Application Time
GT3F-1: 1 Second
Terminal Number
Reset
Input
Set Time
Operation
2 - 10
6 - 7 (11p)
Delayed
Contact
Indicator
Terminal Blocks
Item
Power
ON or L
1-4
8 - 11
(NC)
1-3
9 - 11
(NO)
POWER
T
Ta
800-262-IDEC (4332) • USA & Canada
Ts
T
Circuit Breakers
Tr
853
Timers
GT3F
Switches & Pilot Lights
Instructions: Setting GT3F Series Timers
POWER Indicator
Signaling Lights
l Setting Knob
j Dial Selector
0-1, 0-3, 0-6, 0-18, 0-60
Select a time
range that
contains the
desired period
of time.
Desired Operation
Selection
Base Time Ranges
j Dial Selector
0.1s to 1s
0 to 1
0.1s to 3s
0 to 3
0.1s to 6s
0 to 6
0.1s to 10s
0 to 1
0.3s to 30
0 to 3
0.6s to 60
0 to 6
1.8s to 180s
0 to 18
6s to 600s
0 to 60
Remarks
k Time Range Selector
1s
Time range can be selected from 1S and 10S using a flat screwdriver and five
different dials of 0 to 1, 0 to 3, 0 to 6, 0 to 18, and 0 to 60 are displayed in the six
windows by turning the Dial Selector, allowing for selecting the best suited scale.
Note that the switch does not turn infinitely.
10s
Step 2
Timers
Relays & Sockets
Step 1
k Time Range Selector
1S, 10S
Remarks
Setting Examples:
The set time is selected by turning the l Setting Knob.
1. When the Setting Knob l is set at 2.5, with Dial Selector j 0 to 3 and Time
Range Selector k 1S selected, then the set time is 2.5 seconds.
Circuit Breakers
Terminal Blocks
Contactors
2. When the Setting Knob l is set at 5.0,
with Dial Selector j 0 to 60 and Time Range Selector k 10S selected, then the
set time is 500 seconds.
854
www.IDEC.com
Timers
GT3F
Switches & Pilot Lights
Instructions: Wiring Inputs
Inputs of GT3F
To avoid electric shock, do not touch the input signal terminal during power voltage application.
Never apply the input signals to two or more GT3F timers using the same contact or transistor.
[Incorrect]
GT3 Series
Timer
Input
Contact or Transistor
[correct]
Input
Terminal
Input
Terminal
2
10
2
Power
Power
10
2
Signaling Lights
2
10
Input
Terminal
Input
Terminal
10
In a transistor circuit for controlling input signals, with its primary and secondary power circuits isolated, do not ground the secondary circuit.
GT3 Series
Timer
Input
Terminal
Insulating Transformer
On the GT3F timers, connect the input signals to terminal No.1 and 4 only on the 8-pin type; connect the input signals to terminal No. 6 and 7 only on the 11-pin type.
Never apply voltage to other terminals; otherwise, the internal circuit may be damaged.
Relays & Sockets
Circuit
Rectifier
Circuit
Power
Input signal lines must be made as short as possible and installed away from power cables and power lines. Use shielded wires or a separate conduit for input wiring.
Timers
The GT3F, consisting of a high-impedance circuit, may not be reset due to the influence of an inductive voltage or residual voltage caused by a leakage current. If not
reset, connect an RC filter or bleeder resistor between power terminals so that the voltage between power terminals can be reduced to less than 15% of the rated
voltage.
Contactors
Terminal Blocks
Circuit Breakers
800-262-IDEC (4332) • USA & Canada
855
Timers
GT3W Series — Dual Time Range Timers
Key features:
• Sequential start, sequential interval, on-delay, recycler,
and interval ON timing functions
• 2 time settings in one timer
• 8 selectable operation modes on each model
• Mountable in sockets or flush panel
• Power and output status indicating LEDs
• Time ranges up to 300 hours
Signaling Lights
Switches & Pilot Lights
GT3W
UL, c-UL Listed
File No. E55996
Relays & Sockets
General Specifications
Contact Ratings
Operation System
Solid state CMOS Circuit
Allowable Contact Power
960VA/120W
Operation Type
Multi-Mode
Allowable Voltage
250V AC/150V DC
Time Range
1: 0.1sec to 6 hours, 3: 0.1sec to 300 hours
Allowable Current
5A
Pollution Degree
2 (IE60664-1)
Over Voltage Category
III (IE60664-1)
Maximum permissible
operating frequency
1800 cycles per hour
Rated Operational Voltage
Terminal Blocks
Contactors
Timers
Voltage Tolerance
100-240V AC(50/60Hz)
AD24
24V AC(50/60Hz)/24V DC
D12
12V DC
AF20
85-264V AC(50/60Hz)
AD24
20.4-26.4V AC(50/60Hz)/21.6-26.4V DC
D12
10.8-13.2V DC
Rated Voltage x10% minimum
-10 to +50ºC (without freezing)
Range of Ambient Storage
and Transport Temperature
-30 to +75ºC (without freezing)
Range of Relative Humidity
35 to 85%RH (without condensation)
Atmospheric Pressure
80kPa to 110kPa (Operating), 70kPa to 110kPa (Transport)
Reset Time
60msec maximum
Repeat Error
±0.2%, ±10msec*
Voltage Error
±0.2%, ±10msec*
Temperature Error
±0.6%, ±10msec*
Setting Error
±10% maximum
Insulation Resistance
100MΩ minimum (500V DC)
Dielectric Strength
Between power and output terminals: 2000V AC, 1 minute
Between contacts of different poles: 2000V AC, 1 minute
Between contacts of the same pole:750V AC, 1 minute
Vibration Resistance
10 to 55Hz amplitude 0.75mm2 hours in each of 3 axes
Shock Resistance
Operating extremes: 98m/sec2 (approx.10G)
Damage limits: 490m/sec2 (approx. 50G)
3 times in each of 3 axes
Power Consumption
(Approx.)
IP40 (enclosure), IP20 (socket) (IEC60529)
AF20
2.3VA
200V AC/60Hz
4.6VA
AD24 (AC/DC)
1.8VA/0.9W
Mounting Position
Free
Dimensions
40Hx 36W x 70 mm
Weight (Approx.)
72g
* For the value of the error against a preset time, whichever the largest applies.
856
www.IDEC.com
5A, 120V AC/30V DC
(Resistive)
Conditional Short Circuit
Life
Range of Ambient Operating Temperature
100V AC/60Hz
3A, 240V AC (Resistive)
Rated Load
Disengaging Value of Input Voltage
Degree of Protection
Circuit Breakers
1/8HP, 240V AC
AF20
Fuse 5A, 250V
Electrical
100,000 op. minimum
(Resistive)
Mechanical
20,000,000 op. minimum
Timers
GT3W
Switches & Pilot Lights
Part Number List
Part Numbers
Mode of Operation
Output
Contact
Time Range*
Rated Voltage
100 to 240V AC
(50/60Hz)
3A, 240V AC
5A, 120V AC/30V DC
(Resistive Load)
Delayed
SPDT
+
Delayed
SPDT
1: 0.1sec - 6 hours
*(See Time Range Settings for details.)
New Part Numbers
8 pin
GT3W-A11AF20N
11 pin
GT3W-A11EAF20N
8 pin
GT3W-A11AD24N
11 pin
GT3W-A11EAD24N
8 pin
GT3W-A11D12N
11 pin
GT3W-A11ED12N
24V AC/DC
Signaling Lights
A: Sequential Start
B: On-delay with course and fine
C: Recycler and instaneous
D: Recycler outputs (OFF Start)
E: Recycler outputs (ON Start)
F: Interval ON
G: Interval ON Delay
H: Sequential
Interval
Pin Configuration
12V DC
GT3W-A33AF20N
8 pin
24V AC/DC
Relays & Sockets
3: 0.1sec - 300 hours
100 to 240V AC
(50/60Hz)
GT3W-A33AD24N
1. For timing diagrams and schematics, see page 858.
2. For socket and accessory part number information, see page 860.
3. 8- and 11-pin models differ only in the number of pins (extra pins are not used).
4. For the timing diagram overview, see page 832.
5. *For details on setting time ranges, see the instructions on page 859.
Time Range Table
Time Range Code: 1
Scale
1S
10S
Time Range
0.1 sec - 1 sec
1S
Scale
Time Range
0.1 sec - 3 sec
0.3 sec - 10 sec
1M
10M
15 sec - 10 min
1H
3 min - 3 hours
1S
0.1 sec - 6 sec
1S
0.6 sec - 30 sec
10S
1 sec - 60 sec
1M
6 sec - 6 min
1H
0-6
10M
1 min - 60 min
1H
6 min - 6 hours
10H
0-3
3 sec - 3 min
36 sec - 30 min
0 - 30
36min - 30 hours
Contactors
1M
0-1
Time Range Code: 3
Time Range
Selector
Timers
Time Range
Selector
6 hours - 300 hours
Terminal Blocks
Circuit Breakers
800-262-IDEC (4332) • USA & Canada
857
Timers
GT3W
Operation Chart
Power
2-7
Delayed
Contact
Ry2
Indicator
1-4
(NC)
1-3
(NO)
5-8
(NC)
6-8
(NO)
Description
ON after T1
ON after T1 + T2
OUT1
OUT2
Contactors
C: Recycler and instantaneous
Timers
B: On-delay with course and fine
Set Time
T1
D: Recycler outputs (OFF Start)
Delayed
Contact
Ry2
Indicator
ON after T1 + T2
OUT1
Delayed
Contact
Ry2
Indicator
Set Time
T1
Item
Terminal
No.
2-7
Delayed
Contact
Ry1
Delayed
Contact
Ry2
Indicator
Operation
Description
Instantaneous ON
OFF during T1
ON during T2
OUT1
2-7
Delayed
Contact
Ry1
Delayed
Contact
Ry2
Indicator
Terminal
No.
Power
2-7
Delayed
Contact
Ry1
Delayed
Contact
Ry2
Indicator
Operation
Description
T2
Operation
1-4
(NC)
1-3
(NO)
5-8
(NC)
6-8
(NO)
Description
ON during T1
ON after T1 + T2
OUT1
OFF during T1
ON during T2
OFF during T1
ON during T2
OUT1
T1
Item
Terminal
No.
Power
2-7
Delayed
Contact
Ry1
Delayed
Contact
Ry2
Indicator
OUT2
T2
Operation
1-4
(NC)
1-3
(NO)
5-8
(NC)
6-8
(NO)
ON after T1,
during T2
OUT2
T1
T2
www.IDEC.com
Description
ON during T1 + T2
OUT1
Set Time
Circuit Breakers
858
ON after T1,
during T2
T1
Set Time
T2
1-4
(NC)
1-3
(NO)
5-8
(NC)
6-8
(NO)
Set Time
ON during T1
OUT2
T1
Terminal
No.
Description
OUT1
Item
OUT2
Item
Operation
1-4
(NC)
1-3
(NO)
5-8
(NC)
6-8
(NO)
Set Time
T2
1-4
(NC)
1-3
(NO)
5-8
(NC)
6-8
(NO)
Power
T2
OUT2
OUT2
Power
ON during T1
OFF during T2
T1
Delayed
Contact
Ry1
ON after T1 + T2
ON during T1
OFF during T2
OUT2
1-4
(NC)
1-3
(NO)
5-8
(NC)
6-8
(NO)
Description
Description
OUT1
2-7
Operation
Operation
1-4
(NC)
1-3
(NO)
5-8
(NC)
6-8
(NO)
Power
Set Time
Terminal Blocks
Delayed
Contact
Ry1
2-7
Power
Indicator
2-7
Terminal
No.
Terminal
No.
Delayed
Contact
Ry2
Item
Power
Item
Item
Delayed
Contact
Ry1
Operation Chart
Terminal
No.
Set Time
T2
F: Interval ON
Delayed
Contact
Ry1
Operation
Mode
E: Recycler outputs (ON Start)
Item
Terminal
No.
G: Interval ON Delay
Relays & Sockets
A: Sequential Start
Mode
H: Sequential Interval
Signaling Lights
Switches & Pilot Lights
Timing Diagrams/Schematics
T1
T2
Timers
GT3W
T2 Setting Knob
T2 Time Range Selector
Operation Mode Selector
2. Since changing the setting during timer operation my cause malfunction,
turn power off before changing.
Special expertise is required to use Electronic Timers.
Caution
• All Electronic Timer modules are manufactured under IDEC’s rigorous quality
control system, but users must add a backup or fail safe provision to the
control system when using the Electronic Timer in applications where heavy
damage or personal injury may occur should the Electronic Timer fail.
Caution notices are used where inattention might cause personal injury or damage to equipment.
• Install the Electronic Timer according to instructions described in this catalog.
• In these directions, safety precautions are categorized in order of importance
to Warning and Caution.
• The Electronic Timer is designed for installation in equipment. Do not install
the Electronic Timer outside equipment.
• Install the Electronic Timer in environments described in the specifications. If
the Electronic Timer is used in places where it will be subjected to high-temperature, high-humidity, condensation, corrosive gases, excessive vibrations,
or excessive shocks, then electrical shocks, fire hazard, or malfunction could
result.
Timers
• Make sure that the operating conditions are as described in the specifications. If you are uncertain about the specifications, contact IDEC in advance.
Relays & Sockets
Safety Precautions
Signaling Lights
T1 Setting Knob
T1 Time Range Selector
1. The switches should be securely turned using a flat screwdriver 4mm
wide (maximum). Note that incorrect setting may cause malfunction.
The switches, which do not turn infinitely, should not be turned beyond
their limits.
Switches & Pilot Lights
Instructions: Setting GT3W Timer
• Use an IEC60127-approved fuse and circuit breaker on the power and output
line outside the Electronic Timer.
Warning
Warning notices are used to emphasize that improper operation may cause sever
personal injury or death.
• Do not disassemble, repair, or modify the Electronic Timer.
• When disposing of the Electronic Timer, do so as industrial waste.
Contactors
• Turn power off to the Electronic timer before starting installation, removal,
Wiring, maintenance, and inspection on the Electronic Timer.
• Failure to turn power off may cause electrical shocks or fire hazard.
• Emergency stop and interlocking circuits must be configured outside the
Electronic timer. If such a circuit is configured inside the Electronic Timer,
failure of the Electronic timer may cause malfunction of the control system, or
an accident.
Terminal Blocks
Circuit Breakers
800-262-IDEC (4332) • USA & Canada
859
Timers
Switches & Pilot Lights
GT3 Series Accessories
GT3 Series
Accessories
DIN Rail Mounting Accessories
DIN Rail/Surface Mount Sockets and Hold-Down Springs
DIN Rail Mount Socket
Applicable Hold-Down Springs
Appearance
Use with Timers
Part No.
8-Pin Screw Terminal
(dual tier)
GT3A-1, 2, 3 (8-pin)
GT3F-1, 2 (8-pin)
GT3W (8-pin)
SR2P-05
11-Pin Screw Terminal
(dual tier)
GT3A-1, 2, 3 (11-pin)
GT3A-4, 5, 6
GT3F-1, 2 (11-pin)
GT3W (11-pin)
SR3P-05
Appearance
Part No.
SFA-203
8-Pin Fingersafe Socket
GT3A-1, 2, 3 (8-pin)
GT3F-1, 2 (8-pin)
GT3W (8-pin)
SR2P-05C
11-Pin Fingersafe Socket
GT3A-1, 2, 3 (11-pin)
GT3A-4, 5, 6
GT3F-1, 2 (11-pin)
GT3W (11-pin)
SR3P-05C
8-Pin Screw Terminal
GT3A-1, 2, 3 (8-pin)
GT3F-1, 2 (8-pin)
GT3W (8-pin)
SR2P-06
Timers
Relays & Sockets
Signaling Lights
Style
Terminal Blocks
Contactors
SFA-202
11-Pin Screw Terminal
GT3A-1, 2, 3 (11-pin)
GT3A-4, 5, 6
GT3F-1, 2 (11-pin)
GT3W (11-pin)
SR3P-06
DIN Mounting Rail
Length 1000mm
—
BNDN1000
Installation of Hold-Down Springs
DIN Rail Mount Socket
Panel Mount Socket
Insert the springs into the outer
slots with the projections
facing inside.
Hold-down Spring
SFA-402
Insert the springs
into the slots.
Circuit Breakers
Insert
Socket SR2P-05
Socket SR2P-06
860 Hold-down Spring (sold separately)
SFA-202 (use two springs)
Hold-down Spring (sold separately)
SFA-203 (use two springs)
www.IDEC.com
8-pin Socket
SR2P-51
Timers
GT3 Series Accessories
Switches & Pilot Lights
Panel Mounting Accessories
Panel Mount Sockets and Hold-Down Springs
Panel Mount Socket
Style
Appearance
Applicable HD Springs
Use with Timers
GT3A- (8-pin)
GT3W- (8-pin)
GT3F- (8-pin)
8-Pin Solder Terminal
Part No.
Appearance
Part No.
SR2P-51
Signaling Lights
SFA-402
GT3A- (11-pin)
GT3W- (11-pin)
GT3F- (11-pin)
11-Pin Solder Terminal
SR3P-51
Relays & Sockets
For information on installing the hold-down springs, see page 860.
Flush Panel Mount Adapter and Sockets that use an Adapter
Description
Appearance
Use with Timers
Part No.
Panel Mount Adapter
Adaptor for flush panel mounting GT3 timers
All GT3 timers
RTB-G01
8-pin screw terminal
All 8-pin timers
SR6P-M08G
All 11-pin timers
SR6P-M11G
8-pin solder terminal
All 8-pin timers
SR6P-S08
11-pin solder terminal
All 11-pin timers
SR6P-S11
Timers
Accessory
Contactors
(Shown: SR6P-M08G for Wiring Socket Adapter)
11-pin screw terminal
Sockets for use with
Panel Mount Adapter
Terminal Blocks
Circuit Breakers
No hold down springs are available for flush panel mounting.
800-262-IDEC (4332) • USA & Canada
861
Timers
Switches & Pilot Lights
GT3 Series Instructions
Instructions: Wiring Inputs for GT3 Series
Inputs
To avoid electric shock, do not touch the input signal terminal during power voltage application.
When connecting the input signal terminals of two or more GT3A timers to the same contact or transistor, the input terminals of the same number should be connected. (Connect Terminals No.2 in common.)
[Incorrect]
GT3 Series
Timer
Input
Contact or Transistor
[correct]
Input
Terminal
Signaling Lights
Input
Terminal
2
10
2
Power
Power
Input
Terminal
Input
Terminal
2
10
2
10
10
In a transistor circuit for controlling input signals, with its primary and secondary power circuits isolated, do not ground the secondary circuit.
GT3 Series
Timer
Input
Terminal
Circuit
Insulating Transformer
Connect the input signal terminals of the GT3A timers to Terminal No.2 only. Never apply voltage to other terminals; otherwise, the internal circuit may be damaged.
5, 6, and 7
Input Terminal
2
RY
10
Power
Input signal lines must be made as short as possible and installed away from power cables and power lines. Use shielded wires or a separate conduit for
input wiring.
Circuit Breakers
Terminal Blocks
Contactors
Timers
Rectifier
Circuit
Relays & Sockets
Power
862 www.IDEC.com
Timers
GT3 Series Instructions
Switches & Pilot Lights
Inputs Instructions, continued
For contact input, use gold-plated contacts to make sure that the residual voltage is less than 1V when the contacts are closed.
6
Gate Input
Start Input
Reset Input
5
7
4
8
3
9
2
10
1
11
Power
Signaling Lights
For transistor input, use transistors with the following specifications; VCE = 40V, VCES = 1V or less, IC = 50 mA or more, and ICBO = 50µA or less. The resistance
should be less than 1kΩ when the transistor is on. When the output transistor switches on, a signal is input to the timer.
6
Gate Input
Start Input
Reset Input
5
7
4
8
3
9
2
10
1
11
Relays & Sockets
Power
Inputs: GT3A-1, -2, -3
Transistor output equipment such as proximity switches and photoelectric switches can input signals if they are voltage/current output type, with power voltage
ranges from 18 to 30V and have1V. When the signal voltage switches from H to L, a signal is input to the timer
6
Gate Input
Start Input
Reset Input
5
7
4
8
3
9
2
10
1
11
Power
Timers
Inputs: GT3A-4, -5, -6
The start input initiates a time-delay operation and controls
output status.
Reset Input
When the reset input is activated, the time is reset, and
contacts return to original state.
Gate Input
The time-delay operation is suspended while the gate input
is on (pause).
No-voltage contact inputs and NPN open collector transistor inputs are applicable.
24V DC, 1mA maximum
Contactors
Start Input
Input response time: 50msec maximum
Terminal Blocks
Circuit Breakers
800-262-IDEC (4332) • USA & Canada
863
Timers
GT3 Series Dimensions
Switches & Pilot Lights
Dimensions
36.0
70.0
N40.0
5.6
Unit: mm
Analog GT3 Timer, 11-Pin with SR3P-06
(When using DIN Rail)
When using BAA/BAP: 99 maximum
Analog Setting Type
60
40
36
8
64.2
Holddown
spring
(SFA-202)
DIN Rail
1
18
13
22
36
Analog GT3 Timer, 11-Pin with SR3P-05
Analog Setting Type
(When using DIN Rail)
BAA or BAP: 105.5 maximum
DIN Rail
(BAA/BAP/BADA)
52
33
40
ø27
101.5 maximum
Contactors
Hold-down
Spring (SFA-203)
36
8
64.2
16.5
20
13
3
Timers
1.7
31.7
60
1.7
95 maximum
Holddown
spring
(SFA-202)
28.5
Panel Mount Adapter
Analog GT3 Timer, 8-Pin and 11-Pin
with SR6P-S08 or SR6P-S11
98 maximum
42.5
1.7
Panel Thickness 0.8 to 5mm
48
Terminal Blocks
(When using DIN Rail)
When using BAA/BAP: 99 maximum
95 maximum
31.7
Analog Setting Type
40
Relays & Sockets
Analog GT3 Timer, 8-Pin with SR2P-06
11
61.2
Back Wiring Socket
Circuit Breakers
48
864 www.IDEC.com
8
64.2
13
DIN Rail
18
22
1
Signaling Lights
NOTE: GT3W series are UL Listed when used in combination
with following IDEC’s sockets:
GT3W-A11, A33:
SR2P-06* pin type socket.
GT3W-A11E:
SR3P-05* pin type socket.
(*-May be followed by A,B,C or U)
The socket to be used with these timers are rated:
-Conductor Temperature Rating 60ºC min.
-Use 14AWG max.(2mm2max.) Copper conductors only
-Terminal Torque 1.0 to 1.3 N-m
Timers
GT3 Series Dimensions
45
Tolerance: +0.5 to 0
N: No. of timers mounted
Horizontal Close Mounting
48N--3
GT3 Timer, 8-Pin with SR6P-M08G
GT3 Timer, 11-Pin with SR6P-M11G
8-M3.5 Terminal Screw
Panel Thickness 0.8 to 5mm
3.5 max.
4
5
2
1
8
7
5.6 min.
ø3.6 min.
6
30.4
44.6
3
2
6.9 max.
5
4
1
3
11 7
8
6
9 10
3.5 max.
Signaling Lights
11-M3.5 Teminal Screws
45
16.7
44.6
45
45
34
45
Single
Mounting
Switches & Pilot Lights
Mounting Hole Layout
5.8 min.
ø3.6 min.
6.9 max.
7
80.5
30.5
9.8 × 3
92
7
8.5 × 4
Relays & Sockets
Timers
Contactors
Terminal Blocks
Circuit Breakers
800-262-IDEC (4332) • USA & Canada
865
Timers
General Instructions for All Timer Series
Load Current
Vibration and Shock
With inductive, capacitive, and incandescent lamp loads, inrush current more
than 10 times the rated current may cause welded contacts and other undesired
effects. The inrush current and steady-state current must be taken into consideration when specifying a timer.
Excessive vibration or shocks can cause the output contacts to bounce, the
timer should be used only within the operating extremes for vibration and shock
resistance. In applications with significant vibration or shock, use of hold down
springs or clips is recommended to secure a timer to its socket.
Contact Protection
Time Setting
Switching an inductive load generates a counter-electromotive force (back EMF)
in the coil. The back EMF will cause arcing, which may shorten the contact life
and cause imperfect contact. Application of a protection circuit is recommended
to safeguard the contacts.
The time range is calibrated at its maximum time scale; so it is desirable to use
the timer at a setting as close to its maximum time scale as possible. For a more
accurate time delay, adjust the control knob by measuring the operating time
with a watch before application.
Temperature and Humidity
Input Contacts
Use the timer within the operating temperature and operating humidity ranges
and prevent freezing or condensation. After the timer has been stored below
its operating temperature, leave the timer at room temperature for a sufficient
period of time to allow it to return to operating temperatures before use.
Use mechanical contact switch or relay to supply power to the timer. When
driving the timer with a solid-state output device (such as a two-wire proximity
switch, photoelectric switch, or solid-state relay), malfunction may be caused by
leakage current from the solid-state device. Since AC types comprise a capacitive load, the SSR dielectric strength should be two or more times the power
voltage when switching the timer power using an SSR.
Environment
Avoid contact between the timer and sulfurous or ammonia gases, organic solvents (alcohol, benzine, thinner, etc.), strong alkaline substances, or strong acids.
Do not use the timer in an environment where such substances are prevalent. Do
not allow water to run or splash on the timer.
Timers
Relays & Sockets
Signaling Lights
Switches & Pilot Lights
General Instructions
Generally, it is desirable to use mechanical contacts whenever possible to apply
power to a timer or its signal inputs. When using solid state devices, be cautious
of inrushes and back-EMF that may exceed the ratings on such devices. Some
timers are specially designed so that signal inputs switch at a lower voltage
than is used to power the timer (models designated as “B” type).
Timing Accuracy Formulas
Contactors
Timing accuracies are calculated from the following formulas:
Repeat Error
= ± 1 x Maximum Measured Value – Minimum Measured Value x 100%
2 Maximum Scale Value
Voltage Error
= ± Tv - Tr x 100%
Tr
Tv: Average of measured values at voltage V
Tr: Average of measured values at the rated voltage
Temperature Error
= ± Tt - T20 x 100%
T20
Setting Error
= ± Average of Measured Values - Set Value x 100%
Maximum Scale Value
Circuit Breakers
Terminal Blocks
Tt: Average of measured values at °C
T20: Average of measured values at 20°C
880 www.IDEC.com