MACOM GTCX36-900M-R05 Gas discharge tube Datasheet

Gas Discharge Tubes
GTCX36-XXXM-R05 Series
Raychem Circuit Protection 6mm 3Pole GDTs
(ceramic gas discharge tubes), are commonly used
to help protect sensitive telecom equipment such
as communication lines, signal lines and data
transmission lines from damage caused by
transient surge voltages that typically result from
lightning strikes and equipment switching
operations.
Raychem Circuit Protection GDTs offer a high
level of surge protection, low capacitance and a
broad array of breakover voltage levels, making
them suitable for applications such as MDF (Main
Distribution Frame) modules, high data-rate
telecom applications (e.g. ADSL, VDSL), and
surge protection on power lines. Raychem Circuit
Protection GDTs can help equipment meet the
most stringent regulatory standards.
Benefits:
Features:
• Compact, small form factor suitable for efficient
assembly
• 3Pole, 6mm devices
• Broad voltage range from 75V-600V
• Helps provide overvoltage fault protection against
high energy surges
• Various form factors: surface-mount, leaded, no
leads
• Suitable for high-frequency applications
• Optional fail-short mechanism on some devices
• Low capacitance and insertion loss
• Crowbar overvoltage protection
• UL 497B recognized
• RoHS compliant
• Devices tested per ITU K.12 recommendations
• Non-radioactive materials
Applications:
• Telecommunications
• Industrial and consumer electronics, such as
- MDF modules, xDSL equipment, RF system
- Surge protectors
protection, antenna, base station
- Alarm system
Gas Discharge Tubes
© 2009 Tyco Electronics Corporation. All rights reserved.
1
Document: SCD 27698
Status: Released
Rev: A
Date: JULY 23, 2009
Gas Discharge Tubes
GTCX36-XXXM-R05
Series
GTCX35-XXX-R05
Series
Device Voltage Ratings and Part Marking
Part Number
DC Holdover
Voltage
Impulse
Sparkover
DC Sparkover
On-State Voltage
Nominal
(@ 1A)
(V)
@100V/s
±20% Tolerance
(V)
@100 Vµs (V)
@1000 Vµs (V)
GTCX36-750M-R05
75
450
550
<52
20
GTCX36-900M-R05
90
450
550
<52
20
GTCX36-141M-R05
140
500
600
<80
20
GTCX36-151M-R05
150
500
600
<80
20
GTCX36-201M-R05
200
600
700
<135
20
GTCX36-231M-R05
230
600
700
<135
20
GTCX36-251M-R05
250
600
700
<135
20
GTCX36-261M-R05
260
700
800
<135
20
GTCX36-301M-R05
300
800
900
<150
20
GTCX36-351M-R05
350
900
1000
<150
20
GTCX36-401M-R05
400
900
1000
<150
20
GTCX36-421M-R05
420
900
1000
<150
20
GTCX36-471M-R05
470
1050
1150
<150
20
GTCX36-501M-R05
500
1100
1200
<150
20
GTCX36-551M-R05
550
1300
1400
<150
20
GTCX36-601M-R05
600
1300
1400
<150
20
Per ITU K.12
(<150ms)
(V)
Device Surge Rating, Capacitance, Insulation Resistance, UL
Part Number
GTCX36-XXXM-R05
Impulse
Life
AC
Discharge
Current
(1sec duration;
10 hits)
Capacitance
Insulation
Resistance
UL
Rating
8x20µs
10 hits
10x1000µs
300 hits
@50 Hz
@1Mhz
@100V*
UL497B
#E179610
5kA
200A
5Arms
<1pF
10,000 (MΩ)
All Devices
Impulse
Discharge
Current
* Devices <=150V measured @ 50V.
Devices >= 500V measured @ 250V
Gas Discharge Tubes
© 2009 Tyco Electronics Corporation. All rights reserved.
2
Document: SCD 27698
Status: Released
Rev: A
Date: JULY 23, 2009
Gas Discharge Tubes
GTCX36-XXXM-R05
Series
GTCX35-XXX-R05
Series
Product Dimensions
DIMENSIONS = MILLIMETERS [INCHES]
Axial Leaded with- FT (GTCA36-XXXM-R05-FT)
Axial Leaded (GTCA36-XXXM-R05)
Radial Leaded with- FT (GTCR36-XXXM-R05-FT)
Radial Leaded (GTCR36-XXXM-R05)
Gas Discharge Tubes
© 2009 Tyco Electronics Corporation. All rights reserved.
3
Document: SCD 27698
Status: Released
Rev: A
Date: JULY 23, 2009
Gas Discharge Tubes
GTCX36-XXXM-R05
Series
GTCX35-XXX-R05
Series
No Leads with- FT (GTCN36-XXXM-R05-FT)
No Leads (GTCN36-XXXM-R05)
Surface-mount (GTCS36-XXXM-R05)
Gas Discharge Tubes
© 2009 Tyco Electronics Corporation. All rights reserved.
4
Document: SCD 27698
Status: Released
Rev: A
Date: JULY 23, 2009
Gas Discharge Tubes
GTCX36-XXXM-R05
Series
GTCX35-XXX-R05
Series
Pad Layout – Surface-mount Devices (GTCS36-XXXM-R05)
mm:
in*:
X
NOM
7.0
(0.276)
Y1
NOM
3.6
(0.142)
Y2
NOM
3.6
(0.142)
Z1
NOM
2.5
(0.098)
Z2
NOM
2.0
(0.079)
General Characteristics
No Radioactive Material
Storage Temperature: -40ºC to +90ºC
Operating Temperature: -40ºC to +90ºC
Body: Nickel Plated
Leads: Surface-mount, Radial and Axial Devices: Tin Plated
Devices with no leads: Nickel Plated
Soldering Notes: Devices with no leads: non-solderable; suitable for insertion into a magazine clip
Materials Information
RoHS Compliant
ELV Compliant
Packaging Information
Part Description
Tray / Reel
Standard Package
No Leaded:
GTCN36-XXXM-R05
With Leads:
GTCA36-XXXM-R50/GTCR36-XXXM-R05
Surface-mount: GTCS36-XXXM-R05
Surface-mount (T&R): GTCS36-XXXM-R05-2
100pcs (Tray)
100pcs (Tray)
100pcs (Tray)
750pcs
2,500pcs
1,000pcs
2,500pcs
6000pcs
Gas Discharge Tubes
© 2009 Tyco Electronics Corporation. All rights reserved.
5
Document: SCD 27698
Status: Released
Rev: A
Date: JULY 23, 2009
Gas Discharge Tubes
GTCX36-XXXM-R05
Series
GTCX35-XXX-R05
Series
Part Numbering System
Example Part Number: GTCX36-351M-R05-FT
GT =
C=
X=
3=
6=
351 =
M=
R=
05 =
FT =
Gas Tube
Ceramic
Lead Configuration: N= No leads; A= Axial Leads; S= Surface-mount; R= Radial Leads
3 Electrode device
6mm Diameter
DC Spark Over Voltage of 350V (at 100V/s)
Tolerance of 20% on DC Spark Over Voltage
Product Family Designator
Surge rating: 8x20µs 5kA 10 times
With Fail-Short mechanism
Part Marking Reference
Example Part Marking:
=
35 =
R05 =
GN =
35 R05 GN
Manufacture Mark
Voltage Designator (35 = 350V)
Product Family Designator + Surge Current 5kA (8x20µs 10 hits)
Year and Week of Manufacture
308 Constitution Drive, MS R21/2A
Menlo Park, CA USA 94025-1164
Tel (800) 227-7040
(650) 361-6900
Fax (650) 361-2508
www.circuitprotection.com
www.circuitprotection.com.hk (Chinese)
www.circuitprotection.jp (Japanese)
Raychem, TE Logo and Tyco Electronics are trademarks.
Information furnished is believed to be accurate and reliable. However, users should independently evaluate the suitability of and test each product
selected for their own applications. Tyco Electronics reserves the right to change or update, without notice, any information contained in this publication;
to change, without notice, the design, construction, processing, or specification of any product; and to discontinue or limit production or distribution of
any product. This publication supersedes and replaces all information previously supplied. Without expressed or written consent by an officer of Tyco
Electronics, Tyco Electronics does not authorize the use of any of its products as components in nuclear facility applications, aerospace, or in critical life
support devices or systems. Tyco Electronics expressly disclaims all implied warranties regarding the information contained herein, including, but not
limited to, any implied warranties of merchantability or fitness for a particular purpose. Tyco Electronics’ only obligations are those in the Tyco
Electronics Standard Terms and Conditions of Sale and in no case will Tyco Electronics be liable for any incidental, indirect, or consequential damages
arising from the sale, resale, use, or misuse of its products.
Gas Discharge Tubes
© 2009 Tyco Electronics Corporation. All rights reserved.
6
Document: SCD 27698
Status: Released
Rev: A
Date: JULY 23, 2009
Similar pages