TOKO LL2012-F220NJ Wirewound chip inductor Datasheet

TYPE
Wirewound Chip Inductors
LLQ2012
Meeting Your Needs
Dimensions
1.42 max.
1.70 max.
Recommended
Footprint
1.02
0.76
0.51
1.02
1.03
2.29 max.
The TOKO LLQ2012 Series is a wirewound ceramic chip inductor
that conforms to the EIA standard 0805 footprint and delivers
superb Q and SRF performance with high inductance tolerance.
0.51
24
1.27
0.70
1.78
Unit: mm
Tolerance: ±0.1mm
Part Numbering
Features
• Inductance tolerance: ±2%, ±5%, ±10%
• EIA standard 0805 footprint (2.0mm x 1.2mm)
• Lead-free terminations
• High Q
• High self-resonant frequency
• Operating temperature: –40°C to +125°C
• Packaged on tape and reel in 3,000 piece quantity
• Reflow solderable
LLQ 2012 - F 2N7 J
Tolerance
(G=±2%, J=±5%, K=±10%)
Inductance
Material
Dimensions (LxW)
Type Name
ELECTRICAL CHARACTERISTICS
Q vs Frequency
120
6N8
100
47N
Q
80
60
22N
R12
40
20
0
10
1000
100
10000
Frequency (MHz)
Inductance vs Frequency
1000
Inductance (nH)
R12
47N
100
22N
10
1
10
6N8
1000
100
10000
Frequency (MHz)
1.800.PIK.TOKO
www.tokoam.com
1.847.297.0070
R-LOG1104A
TYPE
LLQ2012 25
Wirewound Chip Inductors
Meeting Your Needs
STANDARD PARTS SELECTION GUIDE
TYPE LLQ2012
Lo
(nH)
Tolerance
Test Freq.
(MHz)
Q
(min.)
Test Freq.
(MHz)
Self Resonant
Frequency
(MHz)
min.
LLQ2012-F2N7_*
2.7
J, K
250
80
1500
7900
0.06
800
LLQ2012-F3N0_*
3.0
J, K
250
65
1500
7900
0.06
800
LLQ2012-F3N3_*
3.3
J, K
250
50
1500
7900
0.08
600
LLQ2012-F5N6_*
5.6
J, K
250
65
1000
5500
0.08
600
LLQ2012-F6N8_*
6.8
J, K
250
50
1000
5500
0.11
600
LLQ2012-F7N5_*
7.5
J, K
250
50
1000
4500
0.14
600
LLQ2012-F8N2_*
8.2
G, J, K
250
50
1000
4700
0.12
600
LLQ2012-F10N_*
10
G, J, K
250
60
500
4200
0.10
600
LLQ2012-F12N_*
12
G, J, K
250
50
500
4000
0.15
600
LLQ2012-F15N_*
15
G, J, K
250
50
500
3400
0.17
600
LLQ2012-F18N_*
18
G, J, K
250
50
500
3300
0.20
600
LLQ2012-F22N_*
22
G, J, K
250
55
500
2600
0.22
500
LLQ2012-F24N_*
24
G, J, K
250
50
500
2000
0.22
500
LLQ2012-F27N_*
27
G, J, K
250
55
500
2500
0.25
500
LLQ2012-F33N_*
33
G, J, K
250
60
500
2050
0.27
500
LLQ2012-F36N_*
36
G, J, K
250
55
500
1700
0.27
500
LLQ2012-F39N_*
39
G, J, K
250
60
500
2000
0.29
500
LLQ2012-F43N_*
43
G, J, K
200
60
500
1650
0.34
500
LLQ2012-F47N_*
47
G, J, K
200
60
500
1650
0.31
500
LLQ2012-F56N_*
56
G, J, K
200
60
500
1550
0.34
500
LLQ2012-F68N_*
68
G, J, K
200
60
500
1450
0.38
500
LLQ2012-F82N_*
82
G, J, K
150
65
500
1300
0.42
400
TOKO
Part Number
Inductance
Q
DC
Resistance
( Ω ) max.
IDC
(mA)
max.
LLQ2012-F91N_*
91
G, J, K
150
65
500
1200
0.48
400
LLQ2012-FR10_*
100
G, J, K
150
65
500
1200
0.46
400
LLQ2012-FR11_*
110
G, J, K
150
50
250
1000
0.48
400
LLQ2012-FR12_*
120
G, J, K
150
50
250
1100
0.51
400
LLQ2012-FR15_*
150
G, J, K
100
50
250
920
0.56
400
LLQ2012-FR18_*
180
G, J, K
100
50
250
870
0.64
400
LLQ2012-FR22_*
220
G, J, K
100
50
250
850
0.70
400
LLQ2012-FR24_*
240
G, J, K
100
44
250
690
1.00
350
LLQ2012-FR27_*
270
G, J, K
100
48
250
650
1.00
350
LLQ2012-FR33_*
330
G, J, K
100
48
250
600
1.40
310
LLQ2012-FR39_*
390
G, J, K
100
48
250
560
1.50
290
LLQ2012-FR47_*
470
J, K
50
33
100
375
1.76
250
LLQ2012-FR56_*
560
J, K
25
23
50
340
1.90
230
LLQ2012-FR68_*
680
J, K
25
23
50
188
2.20
190
LLQ2012-FR82_*
820
J, K
25
23
50
215
2.35
180
* Add tolerance to part number: G = ±2%, J = ±5%, K = ±10%
Testing Conditions: L,Q: Agilent 4287A (Test fixture Agilent 16193A).
R-LOG1104A
SRF: Agilent 8720ES.
1.800.PIK.TOKO
RDC: Agilent 34420A.
IDC: Agilent 34401A
www.tokoam.com
1.847.297.0070