AD ADM1041 Secondary-side controller with current share and housekeeping Datasheet

Secondary-Side Controller with
Current Share and Housekeeping
ADM1041
INTERFACE AND INTERNAL FEATURES
PRODUCT FEATURES
SMBus interface (I2C compatible)
Low-drift precision 2.5 V reference
Voltage error amplifier
Differential current sense
Sense resistor or current transformer option
Overvoltage protection
Undervoltage protection
Overcurrent protection
Overtemperature protection
Start-up undervoltage blanking
Programmable digital debounce and delays
352-byte EEPROM available for field data
160-byte EEPROM for calibration
Ground continuity monitoring
Digital calibration via internal EEPROM
Supports SSI specification
Comprehensive fault detection
Reduced component count on secondary side
Standalone or microcontroller control
SECONDARY-SIDE FEATURES
Generates error signal for primary-side PWM
Output voltage adjustment and margining
Current sharing
Current limit adjustment
OrFET control
Programmable soft-start slew rate
Standalone or microcontroller operation
Differential load voltage sense
AC mains undervoltage detection (ac sense)
Overvoltage protection
APPLICATIONS
Network servers
Web servers
Power supply control
OrFET
RS
VOUT
RLOAD
GND
VDD
VDD
BIAS
PWM
CONTROLLER
VDD
ADM1041
VDD
THERMISTOR
VDD
OTP
VDD
FG
CBD
CS–/VLS
FD
SHRO
CS+
SHRS
VDD
VS +
VCMP
VS–
ICT
PULSE AC_OK
MON2 DC_OK
PSON
PEN
ADD0
CCMP
SCMP
SCL
SDA
GND
SHARE BUS
VOUT
VS +
VS–
MICROCONTROLLER
04521-0-031
OPTIONAL
ISOLATION BARRIER
Figure 1. Typical Application Circuit
Rev. A
Information furnished by Analog Devices is believed to be accurate and reliable.
However, no responsibility is assumed by Analog Devices for its use, nor for any
infringements of patents or other rights of third parties that may result from its use.
Specifications subject to change without notice. No license is granted by implication
or otherwise under any patent or patent rights of Analog Devices. Trademarks and
registered trademarks are the property of their respective owners.
One Technology Way, P.O. Box 9106, Norwood, MA 02062-9106, U.S.A.
Tel: 781.329.4700
www.analog.com
Fax: 781.326.8703
© 2004 Analog Devices, Inc. All rights reserved.
ADM1041
TABLE OF CONTENTS
Specifications..................................................................................... 6
Pulse ............................................................................................. 27
Absolute Maximum Ratings.......................................................... 13
ACSENSE.......................................................................................... 27
ESD Caution................................................................................ 13
OrFET Gate Drive ...................................................................... 28
Pin Configuration and Function Descriptions........................... 14
Oscillator and Timing Generators ............................................... 30
Terminology .................................................................................... 17
Logic I/O and Monitor Pins...................................................... 30
Theory of Operation ...................................................................... 19
SMBus Serial Port....................................................................... 33
Power Management.................................................................... 19
Microprocessor Support............................................................ 33
Gain Trimming and Configuration ......................................... 19
Broadcasting................................................................................ 34
Differential Remote Sense Amplifier............................................ 20
SMBus Serial Interface............................................................... 34
Set Load Voltage.......................................................................... 20
General SMBus Timing ............................................................. 34
Load Overvoltage (OV) ............................................................. 20
SMBus Protocols for RAM and EEPROM.............................. 36
Local Voltage Sense .................................................................... 20
SMBus Read Operations ........................................................... 38
Local OverVoltage Protection (OVP)...................................... 20
SMBus Alert Response Address (ARA)................................... 39
Local UnderVoltage Protection (UVP) ................................... 20
Support for SMBus 1.1............................................................... 39
False UV Clamp.......................................................................... 20
Layout Considerations............................................................... 39
Voltage Error Amplifier ............................................................. 21
Power-Up Auto-Configuration ................................................ 39
Main Voltage Reference ............................................................. 21
Extended SMBus Addressing.................................................... 40
Current Sense Amplifier............................................................ 21
Backdoor Access ......................................................................... 40
Current Sensing .......................................................................... 22
Register Listing ............................................................................... 41
Current Transformer Input ....................................................... 22
Detailed Register Descriptions ..................................................... 42
Current Sense Calibration......................................................... 22
Manufacturing Data................................................................... 51
Current Limit Error Amplifier.................................................. 22
Microprocessor Support ................................................................ 52
Overcurrent Protection ............................................................. 22
Trim Table........................................................................................ 54
Current Share .................................................................................. 24
Appendix A—Configuration Table .............................................. 55
Current Share Offset .................................................................. 24
Appendix B—Test Name Table..................................................... 61
ISHARE Drive Amplifier................................................................. 24
Outline Dimensions ....................................................................... 64
Differential Sense Amplifier...................................................... 24
Ordering Guide .......................................................................... 64
ISHARE Error Amplifier................................................................. 24
REVISION HISTORY
ISHARE Clamp................................................................................. 24
3/04-Revision Sp0: Initial Version
Share_ok Detector ...................................................................... 24
5/04-Changed from Rev. Sp0 to Rev. A
Pulse/ACSENSE2................................................................................. 27
Rev. A | Page 2 of 64
ADM1041
are needed to maintain a stable output. To maintain a stable
loop, the ADM1041 uses three main inputs:
GENERAL DESCRIPTION
The ADM1041 is a secondary-side and management IC specifically designed to minimize external component counts and to
eliminate the need for manual calibration or adjustment on the
secondary-side controller. The principle application of this IC is
to provide voltage control, current share, and housekeeping
functions for single output in N+1 server power supplies.
•
•
•
Remote voltage sense
Load current sense
Current sharing information
In this example, a resistor divider senses the output current as a
voltage drop across a sense resistor (RS) and feeds a portion
into the ADM1041. Remote local voltage sense is monitored via
VS+ and VS− pins. Finally, current sharing information is fed
back via the share bus. These three elements are summed
together to generate a control signal (VCMP), which closes the
loop via an optocoupler to the primary side PWM controller.
The ADM1041 is manufactured with a 5 V CMOS process and
combines digital and analog circuitry. An internal EEPROM
provides added flexibility in the trimming of timing and voltage
and selection of various functions. Programming is done via an
SMBus serial port that also allows communication capability
with a microprocessor or microcontroller.
Another key feature of the ADM1041 is its control of an OrFET.
The OrFET causes lower power dissipation across the ORing
diode. The main function of the OrFET is to disconnect the
power supply from the load in the event of a fault occurring
during steady state operation, for example, if a filter capacitor or
rectifier fails and causes a short. This eliminates the risk of
bringing down the load voltage that is supplied by the redundant configuration of other power supplies. In the case of a
short, a reverse voltage is generated across the OrFET. This
reverse voltage is detected by the ADM1041 and the OrFET is
shut down via the FG pin. This intervention prevents any
interruption on the power supply bus. The ADM1041 can then
be interrogated via the serial interface to determine why the
power supply has shut down.
The usual configuration using this IC is on a one per output
basis. Outputs from the IC can be wire-ORed together or bused
in parallel and read by a microprocessor. A key feature on this
IC is support for an OrFET circuit when higher efficiency or
power density is required.
SAMPLE APPLICATION CIRCUIT DESCRIPTION
Figure 1 shows a sample application circuit using the ADM1041.
The primary side is not detailed and the focus is on the secondary side of the power supply.
The ADM1041 controls the output voltage from the power
supply to the designed programmed value. This programmed
value is determined during power supply design and is digitally
adjusted via the serial interface. Digital adjustment of the
current sense and current limit is also calibrated via the serial
interface, as are all of the internal timing specifications.
This application circuit also demonstrates how temperature can
be monitored within a power supply. A thermistor is connected
between the VDD and MON2 pins. The thermistor’s voltage varies
with temperature. The MON2 input can be programmed to trip
a flag at a voltage corresponding to an overheating power supply.
The resulting action may be to turn on an additional cooling
fan to help regulate the temperature within the power supply.
The control loop consists of a number of elements, notably the
inputs to the loop and the output of the loop. The ADM1041
takes the loop inputs and determines what, if any, adjustments
RSENSE
LOAD
PWM +
PRIMARY
DRIVER
AC PULSE
SENSE
ERROR
AMP
DIFF CURRENT
SENSE
OrFET
CONTROL
CURRENT
SHARE
DIFF LOAD AND LOCAL
VOLTAGE SENSE
VOLT, TEMP MONITOR
AND FAULT DETECTION
ADM1041
SHARE
BUS
SOFT
START
EEPROM AND
RAM AND TRIM
SMBus
Figure 2. Application Block Diagram
Rev. A | Page 3 of 64
(µC OR STANDALONE
OPERATION)
µC
04521-0-002
OPTOCOUPLER
Figure 3. Chip Diagram, Part 1
Rev. A | Page 4 of 64
04521-0-037
CURRENT
TRANSFORMER
TRANSFORMER
CURRENT
SENSE
CONFIGURATON
CCMP
ICT
ACSENSE2
9
4
8
10
PULSE
ACSENSE1
1.5V
40kΩ
GAIN = 10
TRIM
HYSTERESIS
SELECT
ACSENSE
CURRENT SENSE
5.3kΩ
5.3kΩ
0.525V
REG 17h b7
SET GAIN
1 mSec
R
CLK Q
1 Sec
CLK Q
R
R
IRS/
ICT
SQ
R
SQ
SET
CURRENT
SHARE
AC SENSE
AC_OK
PULSEOK
3
VREF
SET CURRENT
LIMIT LEVEL
CURRENT
SHARE
OFFSET
(VSHARE,
IOUT = 0)
2
9R
CURRENT LIMIT
ERROR AMP
R
CS–/FS /VLS
VREF VDD
CS+
CURRENT
6
SHAREOK
FD
REVERSEOK
CURRENT SHARE
50mV
POLARITY
ISHARE
CLAMP
50mV
50kΩ
DIFFERENTIAL
SENSE
ISHARE DRIVE
AMPLIFIER
50kΩ
50kΩ
50kΩ
60µA
ORFET CONTROL
ISHARE ERROR
AMPLIFIER
OrFET OK
TO VOLTAGE ERROR AMP
VREF
REVERSE
VOLTAGE
DETECTOR
PENOK
LOADVOK
V = VOUT + 10V
20
23
24
22
19
VDD
12V
DRAIN
R2
R1
REMOTE
–VE SENSE
1N4148
SHARE BUS
VOUT
GAIN = (R1 + R2)/R2
VS– /SHRS–
SHRS+
SHRO
SCMP
FG
SOURCE
GATE
ADM1041
Figure 4. Chip Diagram, Part 2
Rev. A | Page 5 of 64
ALL POTENTIOMETERS (
ARE DIGITALLY
PROGRAMMBALE
THROUGH REGISTERS
XX
STANDARD I/0 PIN
XX
HIGH VOLTAGE
ANALOG I/O PIN
04521-0-038
3
2
1
NOTES:
REMOTE
SENSE
FROM
LOAD
2
20
21
GND 7
4.4V
4.0V
2.0V
0.2V
SET
LOAD
VOLTAGE
35kΩ
35kΩ
AUXILIARY
REFERENCE
10µs–20µs
gndok_dis
GNDOK
GROUND
MONITOR
OVP
UVLHI
UVLLO
POR
MAIN
BAND GAP
SET UVP
THRESHOLD
SET OVP
THRESHOLD
SET UV CLAMP
THRESHOLD
×1.3
35kΩ
35kΩ
VOLTAGE SENSE
6.0V–6.5V
VS– 20
)
VDD 1
VREF 18
VLS
VS–
VS+
R
S
R
S
Q
Q
Q
UVP
OVP
VDDOV
VDDOK
LOADVOK
POWER MANAGEMENT
INTREFOK
REFERENCE
MONITOR
EXTREFOK
1.25V
2.5V
VREF
1.25V
INTERNAL
REFERENCE
1.5V
FALSE UV
CLAMP
SET LOAD
OVERVOLTAGE
PEN
CBD
DC_OK
AC_OK
PSON
CLOCK
VREF
MON4
MON3
MON2
MON1
MON5
CS
SCL
PEN
STATUS
(READ
REGISTERS)
CONFIGURE
I/Os
CONTROL
LINES SERIAL
INTERFACE
CONFIGURE
WRITE
REGISTERS
PWRON
CONTROL
REGISTERS
VDDOV
VDDOK
RESET
SHAREOK
GENERAL
LOGIC
SHAREOK
AC_OK
PENOK
UVP
OVP
OCP
ORFETOK
AC_OK
PENOK
OCP
1.5V
1.25V
ORFETOK
OCPF
1.25V
2.5V
3V
70µA
VOLTAGE
ERROR AMP
LOGIC AND GPIO
1V
1.5V
VREF
CAPTURE
SOFT START
RAMP UP
VOLTAGE ERROR AMP
CURRENT SHARE
DIFF. VOLTAGE SENSE
CURRENT LIMIT
PEN
CBD/ALERT
DC_OK
AC_OK
VREF
PSON
MON4
MON3
MON2
MON1
OTP/
MON5
VCMP
SCL/
ACONLink
SDA/
PSONLINK
15 ADD0
14
13
12
11
17
18
18
16
17
16
10
9
18
5
ADM1041
ADM1041
SPECIFICATIONS
TA = –40 to +85°C, VDD = 5 V ± 10%, unless otherwise noted.
Table 1.
Parameter
SUPPLIES
VDD
IDD, Current Consumption
Peak IDD, during EEPROM Erase Cycle1, 2
UNDERVOLTAGE LOCKOUT, VDD
Start-Up Threshold
Stop Threshold
Hysteresis
VREF, 2.5 VREFOUT
Output Voltage
Line Regulation
Load Regulation
Temperature Stability2
Long-Term Stability2
Current Limit
Output Resistance2
Load Capacitance
Ripple Due to Autozero2
POWER BLOCK PROTECTION
VDD Overvoltage
VDD Overvoltage Debounce
VREF Overvoltage
VREFOUT Undervoltage
Open Ground
Debounce
POWER-ON RESET
DC Level
DIFFERENTIAL LOAD VOLTAGE SENSE INPUT,
(VS−, VS+)
Min
Typ
Max
Unit
4.5
5.0
6
5.5
10
40
V
mA
mA
4
3.7
4.3
4
0.3
4.5
4.2
V
V
V
2.49
–5
–5
2.50
0
0
±100
±5
10
0.5
1
±5
2.51
+5
+5
V
mV
mV
ppm/°C
mV
mA
Ω
nF
mV p-p
6.2
6.5
20
See Figure 9.
0.35
200
2.75
V
0.5
VDD – 2
1.7 to 2.3
0.10 to 0.14
1.74 –> 3.18
V
V
kΩ
kΩ
V
%
mV
Set Load Overvoltage Trim Range
Set Load Overvoltage Trim Step
105 to 120
0.09
1.6
%
%
mV
Recover from Load OV False to FG True
100
200
300
400
2
µs
µs
µs
µs
µs
Operate Time from Load OV to FG False
5.8
10
20
V
µs
V
V
V
µs
VS− Input Voltage
VS+ Input Voltage
VS− Input Resistance
VS+ Input Resistance
VNOM Adjustment Range
Set Load Voltage Trim Step
Test Conditions/Comments
0.1
100
1.5
2.9
2.1
0.2
2.2
35
500
Rev. A | Page 6 of 64
Reg 0Fh[4:2] = 111. See Table 24.
IREF = 1 mA, TA = 25°C
4.5 V ≤ VDD ≤ 5.5 V
0 mA ≤ IREF ≤ 2 mA
IREF = 1 mA
Over 1,000 hr, TJ = 125°C
VREF = 2.4 V
Recommended for stability
VREF refreshed at 30 kHz
Latching
Internal
External
VGND positive with respect to VS−
VDDOK
VDD rising
See Figure 6. VNOM = (VS+ – VS−)
VNOM is typically 2 V
Voltage on Pin 20
Voltage on Pin 21
1.7 V ≤ VNOM ≤ 2.3 V typ
8 bits, 255 steps
Reg 19h[7:0]. See Table 34
1.7 V ≤ VNOM ≤ 2.3 V min
8 bits, 255 step/s
Reg 08h[7:0]. See Table 17.
VS+ = 2.24 V
Reg 03h[1:0] = 00. See Table 12.
Reg 03h[1:0] = 01. See Table 12.
Reg 03h[1:0] = 10. See Table 12.
Reg 03h[1:0] = 11. See Table 12.
ADM1041
Parameter
LOCAL VOLTAGE SENSE, VLS,
AND FALSE UV CLAMP
Input Voltage Range3
Stage Gain
False UV Clamp, VLS, Input Voltage Nominal,
and Trim Range
Clamp Trim Step
Clamp Trim Step
Min
Typ
Max
Unit
Test Conditions/Comments
See Figure 9.
VDD–2
V
Set by external resistor divider.
At VLS = 1.8 V
1.3
2.3
1.3
1.85
2.1
V
0.2
3.1
Local Overvoltage
Nominal and Trim Range
OV Trim Step
OV Trim Step
1.9
Noise Filter, for OVP Function Only
Local Undervoltage
Nominal and Trim Range
UV Trim Step
UV Trim Step
5
1.3
Noise Filter, for UVP Function Only
VOLTAGE ERROR AMPLIFIER, VCMP
Reference Voltage VREF_SOFT_START
Temperature Stability2
Long-Term Voltage Stability2
Soft-start Period Range
Set Soft-start Period
300
600
µs
1.49
1.51
V
µV/°C
%
ms
µs
ms
ms
ms
MHz
mA/V
µA
µA
Unity Gain Bandwidth, GBW
Transconductance
Source Current
Sink Current
DIFFERENTIAL CURRENT SENSE INPUT,
CS−, CS+
Common-Mode Range
External Divider Tolerance Trim Range
(with respect to input)
External Divider Tolerance Trim Step Size
(with respect to input)
2.4
%
mV
2.85
0.15
3.7
1.7
0.18
3.1
VRANGE
8 bits, 255 steps Reg 0Ah[7:0].
See Table 33.
µs
V
%
mV
VRANGE
8 bits, 255 steps, Reg 09h[7:0].
See Table 18.
−5
V
mV
See Figure 14.
TA = 25°C
−40°C ≤ TA ≤ 85°C
Over 1,000 hr, TJ = 125°C
Ramp is 7 bit, 127 steps
Reg 10h[3:2] = 00. See Table 25.
Reg 10h[3:2] = 01. See Table 25.
Reg 10h[3:2] = 10. See Table 25.
Reg 10h[3:2] = 11. See Table 25.
See Figure 11.
At IVCMP = ±180 µA
At VVCMP > 1 V
At VVCMP < VDD − 1 V
Reg 17h[7] = 0. See Table 18.
ISENSE mode. See Figure 13.
Set by external divider
Reg 16h[5:3] = 000. See Table 31.
−10
−20
5
10
20
20
39
78
mV
mV
mV
mV
mV
µV
µV
µV
Reg 16h[5:3] = 001. See Table 31.
Reg 16h[5:3] = 010. See Table 31.
Reg 16h[5:3] = 100. See Table 31.
Reg 16h[5:3] = 101. See Table 31.
Reg 16h[5:3] = 110. See Table 31.
VCM = 2.0 V
8 bits, 255 steps
Reg 14h[7:0]. See Table 29.
±100
±0.2
0
1.9
250
250
V
%
mV
25
2.1
VRANGE
8 bits, 255 steps, Reg 18h[7:0].
See Table 33.
40
300
10
20
40
1
2.7
0
3.5
VDD–2
Rev. A | Page 7 of 64
ADM1041
Parameter
DC Offset Trim Range (with respect to input)
Min
DC Offset Trim Step Size
(with respect to input)
Typ
−8
−15
−30
8
15
30
30
50
120
Max
Unit
mV
mV
mV
mV
mV
mV
µV
µV
µV
CURRENT SENSE CALIBRATION
Total Current Sense Error2
(Gain and Offset)
VCSCM = 2.0V, 0°C ≤ TA ≤ 85 OC SHRS =
SHRO = 2 V. Gain = 230x
Gain Range (ISENSE)
Gain Setting 1 (Reg 16h[2:0] = 000)
Gain Setting 2 (Reg 16h[2:0] = 001)
Gain Setting 3 (Reg 16h[2:0] = 010)
Gain Setting 4 (Reg 16h[2:0] = 100)
Gain Setting 5 (Reg 16h[2:0] = 101)
Gain Setting 6 (Reg 16h[2:0] = 110)
Full Scale (No Offset)
Attenuation Range
Current Share Trim Step (at SHRO)
±3
±6
%
%
65
85
110
135
175
230
V/V
V/V
V/V
V/V
V/V
V/V
2.0
65 to 99
0.4
8
+5
V
%
%
mV
%
Gain Accuracy2, 4, 40 mV at CS+, CS−
−5
Gain Accuracy2, 4, 20 mV at CS+, CS−
−5
±1
+5
%
Gain Accuracy2, 4, 40 mV at CS+, CS–
−2.5
±0.5
+2.5
%
SHARE BUS OFFSET
Current Share Offset Range
1.25
V
Zero Current Offset Trim Step
0.4
5.5
%
mV
4.5
2.57
V/V
V/V
CURRENT TRANSFORMER SENSE INPUT, ICT
Gain Setting 0
Gain Setting 1
CT Input Sensitivity
CT Input Sensitivity
Input Impedance2
Source Current
0.45
0.79
20
Source Current Step Size
Reverse Current for Extended SMBus
Addressing (Source Current) 5
Test Conditions/Comments
Reg 17h[2:0] = 000. See Table 32 .
Reg 17h[2:0] = 001. See Table 32.
Reg 17h[2:0] = 010. See Table 32.
Reg 17h[2:0] = 100. See Table 32.
Reg 17h[2:0] = 101. See Table 32.
Reg 17h[2:0] = 110. See Table 32.
VCM = 2.0 V, VDIFF = 0 V
8 bits, 255 steps
Reg 15h[7:0]. See Table 30.
0.5
1.0
50
2.0
0.68
1.20
170
3.5
5
V
V
kΩ
µA
nA
7
Rev. A | Page 8 of 64
mA
Chopper ON
Chopper OFF
Input voltage range at CS+, CS−
34.0 mV – 44.5 mV. Gain = 65×
26.0 mV – 34.0 mV. Gain = 85×
20.0 mV – 26.0 mV. Gain = 110×
16.0 mV – 20.0 mV. Gain = 135×
12.0 mV – 16.0 mV. Gain = 175×
9.5 mV – 12.0 mV. Gain = 230×
VZO = 0
Reg 06h[7:1]. See Table 15.
SHRS = SHRO = 1 V
7 bits, 127 steps ISHARE slope
0 V ≤ VCSCM ≤ 0.3 V. Gain = 65×
VCSCM = Input Common Mode
VCSCM = 2.0V, 0°C ≤ TA ≤ 85°C
Gain = 135×
VCSCM = 2.0 V, 0°C ≤ TA ≤ 85°C
Gain = 65×
See Figure 13.
Reg 17h[7] = 1. See Table 32.
Reg 17h[5] = 1. See Table 32.
0 ≤ VTRIM ≤ 1.25 V
8 bits, 255 steps, VCT = 1.0 V
Reg 05h[7:0]. See Table 14.
Reg 17h[7] = 1. See Table 32.
Reg 06h = FEh. See Table 15.
Reg 17h[5] = 0, VSHARE = 2 V. Table 31
Reg 17h[5] = 1. See Table 32.
Reg 15h = 05h, approx 1 µA.
See Table 30. VSHARE = 2 V.
Gain setting = 4.5
Gain setting = 2.57
See Current Transformer Input
Section.
15 steps Reg 15h[3:0].
See Table 30.
See Figure 38. See Absolute
Maximum Ratings.
ADM1041
Parameter
CURRENT LIMIT ERROR AMPLIFIER
Current Limit Trim Range2
Current Limit Trim Step
Current Limit Trim Step
Transconductance
Output Source Current
Output Sink Current
CURRENT SHARE DRIVER
Output Voltage6
Short Circuit Source Current
Source Current
Sink Current
CURRENT SHARE DIFFERENTIAL SENSE
AMPLIFIER
VS– Input Voltage
VSHRS Input Voltage
Input Impedance2
Gain
CURRENT SHARE ERROR AMPLIFIER
Transconductance, SHRS to SCMP
Output Source Current
Output Sink Current
Input Offset Voltage
Min
Typ
105
Max
Unit
130
%
%
mV
1.1
26.5
100
200
40
40
300
VDD – 0.4
60
65
100
1.0
100
200
40
40
50
40
Share OK Window Comparator Threshold
(Share Drive Error)
µA/V
µA
µA
Test Conditions/Comments
See Figure 13
After ISHARE calibration
2.0 ≤ VSHARE ≤ 2.8 V typ. 5 bits, 31 steps.
Reg 04h[7:3]. See Table 13.
ICCMP = ±20 µA. See Figure 12.
VCCMP = > 1 V
VCCMP = < VDD – 1 V
See Figure 14.
RL = 1 kΩ, VSHRS ≤ VDD – 2 V
55
15
V
mA
mA
100
µA
0.5
VDD – 2
V
V
kΩ
V/V
Voltage on Pin 20
Voltage on Pin 23
VSHRS = 0.5 V, VS− = 0.5 V
300
µA/V
µA
µA
mV
ISCMP = ±20 µA
VSCMP > 1 V
VSCMP < VDD – 1 V
Master/slave arbitration
mV
mV
mV
mV
SHRS = 2 V ± SHRTHRESH
Reg 04h[1:0] = 00. See Table 13.
Reg 04h[1:0] = 01. See Table 13.
Reg 04h[1:0] = 10. See Table 13.
Reg 04h[1:0] = 11. See Table 13.
60
±100
±200
±300
±400
Current at which VOUT does not drop
by more than 5%
VSHARE = 2.0 V
See Figure 14.
CURRENT LIMIT
Current Limit Control Lower Threshold
Current Limit Control Upper Threshold
CURRENT SHARE CAPTURE
Current Share Capture Range
Capture Threshold
FET OR GATE DRIVE
Output Low Level (On)
Output Leakage Current
REVERSE VOLTAGE COMPARATOR, FS, FD
Common-Mode Range
1.3
0.7
1.4
2.1
2.8
0.6
1
2
3
4
1.0
−5
0.25
2.0
3.5
V
V
1.3
2.6
3.9
5.2
1.4
%
%
%
%
V
0.4
0.8
+5
V
V
µA
VDD – 2
V
Rev. A | Page 9 of 64
Figure 10.
VCCMP = 0.7 V, VS+ = 1.5 V
VS+ = 0 V, VSCMP = 0 V
VSCMP = 3.5 V.
Reg 10h[5:4] = 00. See Table 25.
Reg 10h[5:4] = 01. See Table 25.
Reg 10h[5:4] = 10. See Table 25.
Reg 10h[5:4] = 11. See Table 25.
Open-drain N-channel FET
IIO = 5 mA
IIO = 10 mA
VCS− = FS
Voltage set by CS resistor divider
Voltage on CS− pin. TA = 25°C.
ADM1041
Parameter
Reverse Voltage Detector Turn-Off Threshold
Min
Typ
Max
Unit
100
150
200
250
mV
mV
mV
mV
20
30
40
50
mV
mV
mV
mV
kΩ
kΩ
Reverse Voltage Detector Turn-On Threshold
FD Input Impedance
FS Input Impedance
ACSENSE1/ACSENSE2 COMPARATOR
500
20
Reg 12h[2] = 0
Reg 0Dh[3:2] = 00. See Table 22 .
Reg 12h[2] = 1
Reg 0Eh[7:6] = 00. See Table 23.
(AC or Bulk Sense)
Threshold Voltage
Threshold Adjust Range
1.25
1.10
1.40
V
V
Threshold Trim Step
0.8
10
%
mV
Hysteresis Adjust Range
Hysteresis Trim Step
200−550
50
mV
mV
Noise Filter
PULSE-IN
Threshold Voltage
PULSE_OK On Delay
PULSE_OK Off Delay
OSCILLATOR
OCP
OCP Threshold Voltage2
0.6
0.8
−5
0.3
OCP Shutdown Delay Time (Continuous
Period in Current Limit)
OCP Fast Shutdown Delay Time
MON1, MON2, MON3, MON4
Sense Voltage
Hysteresis
OVP Noise Filter
UVP Noise Filter
OTP (MON5)
Sense Voltage Range
OTP Trim Step
Hysteresis
Test Conditions/Comments
VCS− = 2 V for threshold specs
Reg 03h[7:6] = 00. See Table 12.
Reg 03h[7:6] = 01. See Table 12.
Reg 03h[7:6] = 10. See Table 12.
Reg 03h[7:6] = 11. See Table 12.
VCS− = 2 V for threshold specs
Reg 03h[5:4] = 00. See Table 12.
Reg 03h[5:4] = 01. See Table 12.
Reg 03h[5:4] = 10. See Table 12.
Reg 03h[5:4] = 11. See Table 12.
1
0.525
1
1
0.5
ms
1.2
+5
V
µs
s
%
0.7
V
1
s
2
3
4
s
s
s
ms
0
1.21
1.2
100
1.25
0.1
1.29
5
300
25
600
2.2
2.45
Min: DAC = 0
Max: DAC = Full Scale
1.10 ≤ VTRIM ≤ 1.4 V
5 bits, 31 steps
Reg 0Ch[7:3]. See Table 21.
VACSENSE > 1 V, RTHEVENIN = 909R
200 ≤ VTRIM ≤ 550 mV. 7 steps
Reg 0Ch[2:0]. See Table 21.
Unless otherwise specified
Force CCMP for drop in VCMP
Reg 11h[2] = 0. See Table 26.
Reg 12h[4:3] = 00. See Table 27.
Reg 12h[4:3] = 01. See Table 27.
Reg 12h[4:3] = 10. See Table 27.
Reg 12h[4:3] = 11. See Table 27.
Reg 11h[2] = 1. See Table 26.
VCCMP = 1.5 V
V
V
µs
µs
Reg 0Fh[4:2] = 01x or 10x. Table 24.
24
100
130
160
Rev. A | Page 10 of 64
V
mV
µA
2.1 ≤ VTRIM ≤ 2.45 V
4 bits, 15 steps, Reg 0Bh[7:4].
See Table 20.
VOTP = 2 V
ADM1041
Parameter
OVP Noise Filter
Min
5
UVP Noise Filter
300
PSON7
Input Low Level8
Input High Level8
Debounce
PEN7, DC_OK7, CBD, AC_OK
Open-Drain N-Channel Option
Output Low Level = On8
Open-Drain P-Channel
Output High Level = On8
Leakage Current
DC_OK7
DC_OK, On Delay (Power-On and OK Delay)
Max
25
Unit
µs
600
µs
0.8
V
V
ms
ms
ms
ms
2.0
80
0
40
160
2.4
−5
0.4
V
+5
V
µA
400
200
800
1600
2
0
1
4
DC_OK, Off Delay (Power-Off Early Warning)
SMBus, SDL/SCL
Input Voltage Low8
Input Voltage High8
Output Voltage Low8
Pull-Up Current
Leakage Current
ADD0, HARDWIRED ADDRESS BIT
ADD0 Low Level8
ADD0 Floating
ADD0 High8
SERIAL BUS TIMING
Clock Frequency
Glitch Immunity, tSW
Bus Free Time, tBUF
Start Setup Time, tSU;STA
Start Hold Time, tHD;STA
SCL Low Time, tLOW
SCL High Time, tHIGH
SCL, SDA Rise Time, tR
SCL, SDA Fall Time, tF
Data Setup Time, tSU;DAT
Data Hold Time, tHD;DAT
EEPROM RELIABILITY
Endurance9
Data Retention10
Typ
ms
ms
ms
ms
ms
ms
ms
ms
0.8
2.2
0.4
350
+5
100
−5
0.4
VDD/2
VDD − 0.5
Test Conditions/Comments
Reg 0Fh[4:2] = 010 or 100.
See Table 24.
Reg 0Fh[4:2] = 011 or 101.
See Table 24.
Reg 0Eh[4:2] = 00x. See Table 23.
Reg 0Fh[1:0] = 00. See Table 24.
Reg 0Fh[1:0] = 01. See Table 24.
Reg 0Fh[1:0] = 10. See Table 24.
Reg 0Fh[1:0] = 11. See Table 24.
ISINK = 4 mA
VOH_PEN
ISOURCE = 4 mA
Reg 0Fh[7:5] = 00x. See Table 24.
Reg 0Eh[1:0] = 00. See Table 23.
Reg 0Eh[1:0] = 01.See Table 23.
Reg 0Eh[1:0] = 10. See Table 23.
Reg 0Eh[1:0] = 11. See Table 23.
Reg 10h[7:6] = 00. See Table 25.
Reg 10h[7:6] = 01. See Table 25.
Reg 10h[7:6] = 10. See Table 25.
Reg 10h[7:6] = 11. See Table 25.
V
V
V
µA
µA
VDD = 5 V, ISINK = 4 mA
V
V
V
Floating
See Figure 5.
400
50
4.7
4.7
4
4.7
4
1000
300
250
300
100
100
250
Rev. A | Page 11 of 64
kHz
ns
µs
µs
µs
µs
µs
ns
ns
ns
ns
k cycles
Years
ADM1041
1
This specification is a measure of IDD during an EEPROM page erase cycle. The current is a dynamic. Refer to Figure 29 for a typical IDD plot during an EEPROM page
erase.
2
Specification is not production tested, but is supported by characterization data at initial product release.
3
Four external divider resistors are the same ration, which is selected to produce 2.0 V nominal at Pin 21 while at zero load current. Recommended values are
RTOP
RBOTTOM
3.3 V
680R
1K
5.0 V
1K.5
1K
12 V
5K1
1K
4
Chopper off.
The maximum specification here is the maximum source current of Pin 8 as specified by the Absolute Maximum Ratings.
6
All internal amplifiers accept inputs with common range from GND to VDD − 2 V. The output is rail to rail but the input is limited to GND to VDD − 2 V. See Figure 6.
7
These pins can be configured as open-drain N-channel or P-channel, (except PSON) and as normal or inverted logic polarity. Refer to Table 45.
8
A logic true or false is defined strictly according to the signal name. Low and high refer to the pin or signal voltages.
9
Endurance is qualified to 100,000 cycles as per JEDEC std. 22 method A117, and measured at −40°C, +25°C, and +85°C. Typical endurance at 25°C is 250,000 cycles.
10
Retention lifetime equivalent at junction temperature (TJ) = 55°C as per JEDEC std. 22 method A117. Retention lifetime based on an activation energy of 0.6 V. Derates
with junction temperature.
5
tLOW
tR
tF
tHD:STA
SCL
tHD:DAT
tHIGH
tSU:STA
tSU:DAT
tSU:STO
SDA
tBUF
S
S
P
Figure 5. Serial Bus Timing Diagram
SHRO
VA
VA = VDD – 0.4V
R1
SHRS+
VB
VB = VDD – 2V
R1
SHRS–
R1 + R2 ≥ 1kΩ
04521-0-004
P
Figure 6. Amplifier Inputs and Outputs
Rev. A | Page 12 of 64
04521-0-005
tHD:STA
ADM1041
ABSOLUTE MAXIMUM RATINGS
Table 2.
Parameter
Supply Voltage (Continuous), VDD
Data Pins SDA, SCL, VDATA
Continuous Power at 25°C, PD-QSOP24
Operating Temperature, TAMB
Junction Temperature, TJ
Storage Temperature, TSTG
Lead Temperature
(Soldering, 10 Seconds), TL
ESD Protection on All Pins, VESD
Thermal Resistance, Junction to Air, θJA
ICT Source Current1
1
Thermal Characteristics
Rating
6.5 V
VDD + 0.5 V,
GND − 0.3 V
450 mW
−40°C to +85°C
150°C
−60°C to +150°C
300°C
24-Lead QSOP Package:
θJA = 150°C/W
Stresses above those listed under Absolute Maximum Ratings
may cause permanent damage to the device. This is a stress
rating only; functional operation of the device at these or any
other conditions above those indicated in the operational
section of this specification is not implied. Exposure to absolute
maximum rating conditions for extended periods may affect
device reliability.
2 kV
150°C/W
7 mA
This is the maximum current that can be sourced out from Pin 8 (ICT pin).
ESD CAUTION
ESD (electrostatic discharge) sensitive device. Electrostatic charges as high as 4000 V readily accumulate on
the human body and test equipment and can discharge without detection. Although this product features
proprietary ESD protection circuitry, permanent damage may occur on devices subjected to high energy
electrostatic discharges. Therefore, proper ESD precautions are recommended to avoid performance
degradation or loss of functionality.
Rev. A | Page 13 of 64
ADM1041
PIN CONFIGURATION AND FUNCTION DESCRIPTIONS
VDD 1
24
SHRO
VLS/CS–/FS 2
23
SHRS+
CS+ 3
22
SCMP
CCMP 4
21
VS+
VCMP 5
20
VS–/SHRS–
FD 6
ADM1041
19 FG
TOP VIEW
18 VREF/AC_OK/OTP/MON5
(Not to Scale)
17 DC_OK/MON4
ICT 8
PULSE/ACSENSE1/MON1 9
16
PSON/MON3
ACSENSE2/MON2 10
15
ADD0
CBD/ALERT 11
14
SDA/PSONLINK
PEN 12
13
SCL/AC_OKLink
04521-0-030
GND 7
Figure 7. Pin Configuration
Table 3. Pin Function Descriptions
Pin No.
1
2
Mnemonic
VDD
VLS/CS–/FS
3
CS+
4
CCMP
5
VCMP
6
FD
7
GND
8
ICT
9
PULSE/ACSENSE1/MON1
Description
Positive Supply for the ASIC. Normal range is 4.5 V to 5.5 V. Absolute maximum rating is 6.5 V.
Inverting Differential Current Sense Input, Local Voltage Sense Pin, and OrFET Source. These three
functions are served by a common divider. The local voltage sense input is used for local overvoltage
and undervoltage sensing. This pin also provides an input to the false UV clamp that prevents
shutdown during an external load overvoltage condition. When supporting an OrFET circuit, this pin
represents the FET source and is the inverting input of a differential amplifier looking for the presence
of a reverse voltage across the FET, which might indicate a failure mode.
Noninverting Differential Current Sense Input. The differential sensitivity of CS+ and CS– is normally
around 10 mV to 40 mV at the input to the ASIC. Nulling any external divider offset is achieved by
injecting a trimmable amount of current into either the inverting or noninverting input of the second
stage of the current sense amplifier. A compensation circuit is used to ensure the amount of current
for zero-offset tracks the common-mode voltage. Nulling of any amplifier offset is done in a similar
manner except that it does not track the common-mode voltage.
Current Error Amplifier Compensation. This pin is the output of the current limit transconductance
error amplifier. A series resistor and a capacitor to ground are required for loop compensation.
Voltage Error Amplifier Compensation. This is the output of a voltage error transconductance
amplifier. Compensate with a series capacitor and resistor to ground. An external emitter-follower or
buffer is typically used to drive an optocoupler. Output voltage positioning may be obtained by
placing a second resistor directly to ground. Refer to Analog Devices applications notes on voltage
positioning.
A divider from the OrFET drain is connected here. A differential amplifier is then used to detect the
presence of a reverse voltage across the FET, which indicates a fault condition and causes the OrFET
gate to be pulled low.
Ground. This pin is double bonded for extra reliability. If the ground pin goes positive with respect to
the remote sense return (VS–) for a sustained period indicating that the negative remote sense line is
disconnected, PEN will be disabled.
Input for Current Transformer. The sensitivity of this pin is suitable for the typical 0.5 V to 1 V signal
that is normally available. If this function is enabled, the CS+ amplifier is disabled. This pin is also used
for extended SMBus addressing, i.e., pulled below ground to allow additional SMBus addresses.
Pulse Present, AC/Bulk Sense 1, or Monitor 1 Input.
PULSE: This tells the OrFET circuit that the voltage from the power transformer is normal. A peak hold
allows the OrFET circuit to pass through the pulse skipping that occurs with very light loads but turns
off the circuit about one second after the last pulse is recognized.
ACSENSE1: This sense function also uses the peak voltage on this pin to measure the bulk capacitor
voltage. If too low, AC_OK and DC_OK can warn of an imminent loss of power. Threshold level and
hysteresis can be trimmed. When not selected, ACSENSE1 defaults to true.
MON1: When MON1 is selected for this pin, its input is compared against a 1.25 V comparator that
could be used for monitoring a post regulated output; includes overvoltage, undervoltage, and
overtemperature conditions.
Rev. A | Page 14 of 64
ADM1041
Pin No.
10
Mnemonic
ACSENSE2/MON2
11
CBD/ALERT
12
PEN
13
SCL/AC_OKLink
14
SDA/PSONLINK
15
ADD0
16
PSON/MON3
17
DC_OK/MON4
18
VREF/AC_OK/OTP/MON5
19
FG
20
VS–/SHRS–
Description
AC/Bulk Sense Input 2 or Monitor 2 Input.
ACSENSE2: This alternative ACSENSE input can be used when the ACSENSE source must be different from
that used for the OrFET. It also allows dc and opto-coupled signals that are not suitable for the OrFET
control.
MON2: When MON2 is selected for this pin, its input is compared against a 1.25 V comparator that
could be used for monitoring a post regulated output; includes overvoltage, undervoltage, and
overtemperature conditions.
CBD: The crowbar drive pin allows implementation of a fast shutdown in case of a load overvoltage
fault. The pin can be configured as an open-drain N-channel or P-channel and is suitable for driving a
sensitive gate SCR crowbar. An external transistor is required if a high gate current is needed. Either
polarity may be selected.
ALERT: This pin can be configured to provide an ALERT function in microprocessor-supported
applications whereby any of several ICs in a redundant system that detects a problem can interrupt
and shut down the power supply. An alternative use is as a general-purpose logic output signal.
Power Enable. This pin can be configured as an open-drain N-channel or P-channel that typically
drives the PEN optocoupler. Providing that the PSON pin has been asserted to turn the output on, and
that there are no faults, this pin drives an optocoupler on enabling the primary PWM circuit. Either
polarity may be selected.
SCL: SMBus Serial Clock Input.
AC_OKLink: In non-microprocessor applications, this pin can be programmed to give the status of
ACSENSE to all the ICs on the same bus. The main effect is to turn on undervoltage blanking whenever
the sense circuit monitoring ac or bulk dc detects a low voltage.
SDA: SMBus Serial Data Input and Output.
PSONLINK: In non-microprocessor applications, this pin can be programmed to provide the PSON
status to other ICs. This allows just one IC to be the PSON interface to the host system, or the PSONLINK
itself can be the PSON interface.
Chip Address Pin. There are three addresses possible using this pin, which are achieved by tying ADD0
to ground, tying to VDD, or being left to float. One address bit is available via programming at the
device/daughter card level so the total number of addressable ICs can be increased to six.
PSON: In non-microprocessor configurations, this is power supply on. As a standard I/O, this pin is
rugged enough for direct interface with a customer’s system. Either polarity may be selected.
MON3: When MON3 is selected for this pin, its input is compared against a 1.25 V comparator that
could be used for monitoring a post-regulated output; includes overvoltage, undervoltage, and
overtemperature conditions.
DC_OK: This pin is the output of a general-purpose digital I/O that can be configured as open-drain
N-channel or open-drain P-channel suitable for wire-ORing with other ICs and direct interfacing with a
customer’s system. Either polarity may be selected.
MON4: When MON4 is selected for this pin, its input is compared against a 1.25 V comparator that
could be used for overtemperature protection and for monitoring a post-regulated output; includes
overvoltage, undervoltage, and overtemperature conditions.
Voltage Reference, Buffered Output, Overtemperature Protection, or Monitor 5.
VREF: This is a 2.5 V precision reference voltage capable of sourcing 2 mA. This function is continuously
monitored, and if the voltage falls below 2.0 V, PEN is disabled. Forcing this pin's voltage does not
affect the integrity of the internal reference.
AC_OK: This option can be configured as N-channel or P-channel and as normal or inverted polarity.
At system level, a true AC_OK is used to indicate that the primary bulk voltage is high enough to
support the system, and when false, that dc output is about to fail.
MON5: A further option is to configure this as an analog input, MON5, with a flexible hysteresis and
trimmable 2.5 V reference that makes this pin particularly suitable for overtemperature protection
(OTP) sensing. Since hysteresis uses a switched 100 µA current source, hysteresis can be adjusted via
the source impedance of the external circuit. It can also be used for overvoltage and undervoltage
functions.
FET Gate Enable. When supporting an OrFET circuit, this is the gate drive pin. Since the open-drain
voltage on the chip is limited to VDD, an external level shifter is required to drive the higher gate
voltages suitable for the OrFET. This pin is configured as an open-drain N-channel. Either output
polarity, low = on or low = off, may be selected.
This pin is used as the ground input reference for the current share and load voltage sense circuits. It
should be tied to ground at the common remote sense location. The input impedance is about 35 kΩ
to ground.
Rev. A | Page 15 of 64
ADM1041
Pin No.
21
Mnemonic
VS+
22
SCMP
23
SHRS+
24
SHRO
Description
This pin is the positive remote load voltage sense input and is normally divided down from the power
supply output voltage to 2.0 V at no load using an external voltage divider. The input impedance is
high.
Output of the Current Share Transconductance Error Amplifier. Compensation is a series capacitor and
resistor to ground. While VDD is normal and PEN is false, this pin is clamped to ground. When the
converter is enabled (PEN true) and the clamp is released, the compensation capacitor charges
providing a slow walk-in. The error amplifier input has a built-in bias so that all slaves in a parallel
supply system do not compete with the master for control of the share bus.
Current Share Sense. This is the noninverting input of a differential sense amplifier looking at the
voltage on the share bus. For testing purposes, this pin is normally connected to SHRO. Calibration
always expects this pin to be at 2.0 V with respect to SHRS–/VS–. If a higher share voltage is required, a
resistor divider from SHRO or an additional gain stage, as shown in the application notes, must be
used.
Current Share Output. This output is capable of driving the share bus of several power supplies
between 0 V and VDD – 0.4 V (10 kΩ bus pull-down in each supply). Where a higher share bus voltage is
required, an external amplifier is necessary. The current share output from the supply which, when
bused with the share output of other power supplies working in parallel, allows each of the supplies
to contribute essentially equal currents to the load.
Table 4. Default Pin States during EEPROM Download
Pin No.
11
Mnemonic
CBD
12
PEN
17
DC_OK
18
AC_OK
19
FG
State
High impedance (Hi-Z) at power-up and until the end of the EEPROM download (approximately 20 ms).
This pin is reconfigured at the end of the EEPROM download.
High impedance (Hi-Z) at power-up and until the end of the EEPROM download (approximately 20 ms).
This pin is reconfigured at the end of the EEPROM download.
Active low (low if DC_OK true) at power-up.
This pin is reconfigured during the EEPROM download.
Active low (low if DC_OK true) at power-up.
This pin is reconfigured during the EEPROM download.
High impedance (Hi-Z) at power-up and until the end of the EEPROM download (approximately 20 ms).
This pin is reconfigured at the end of the EEPROM download.
Rev. A | Page 16 of 64
ADM1041
TERMINOLOGY
Table 5.
Mnemonic
POR
UVL
CVMode
CCMode
UVP
OVP
OCP
OTP
UVB
DC_OK
AC_OK
DC_OKondelay
DC_OKoffdelay
Debounce Digital Noise Filter
ACSENSE1
Description
Power-On Reset. When VDD is initially applied to the ASIC, the POR function clears all latches and puts
the logic into a state that allows a clean start-up.
Undervoltage Lockout. This is used on VDD to prevent spurious modes of operation that might occur if
VDD is below a specific voltage.
Constant Voltage Mode. This is the normal mode of operation of the power supply main output. The
output voltage remains constant over the whole range of current specified.
Constant Current Mode. This mode of operation occurs when the output is overloaded until or unless
a shutdown event is triggered. The output current control level remains constant down to 0 V.
Undervoltage Protection. If the output being monitored is detected as going under voltage, the UVP
function sends a fault signal. After a delay, PEN goes false, the output is disabled, and either latch-off
or an auto-restart occurs, depending on the mode selected. The DC_OK output also goes false
immediately to show that the output is out of tolerance.
Overvoltage Protection. If the output being monitored is detected as going over voltage, the OVP
function latches and sends a fault signal, PEN goes false, and CBD goes true. The DC_OK output also
goes false immediately. OVP faults are always latching and require the cycling of PSON or VDD or
SMBus command to reset the latch.
Overcurrent Protection. If the output being monitored is detected as going over current for a certain
time, the OCP function sends out a fault signal that triggers a shutdown that can be latched or
allowed to auto-restart, depending on the mode selected. Prior to shutting down, the DC_OK output
goes false warning the system that output will be lost. The latch is the same one used for OVP. For
auto-restart, the OCP time out period is configurable.
Overtemperature Protection. If the temperature being sensed is detected as going over the selected
limit, the OTP function sends out a fault signal that triggers a shutdown that can be latched or allowed
to auto-restart depending on the mode selected. Prior to shutting down, the DC_OK output goes false
warning the system that output will be lost. The latch is the same one used for OVP.
Undervoltage Blanking. The UVP function is blanked (disabled) during power-up or if the ACSENSE
function is false (ac line voltage is low). When in constant current mode, UVB is disabled. The status of
ACSENSE must be known to the IC, either by virtue of the on-board ACSENSE or communicated by the
SMBus with the help of an external microprocessor or by using AC_OKLink. When in constant current
mode, due to an overload, UVB is applied for the overcurrent ride through period.
The DC_OK function advises the system on the status of the power supply. When it is false, the system
is assured of at least 1 ms of operation if ac power is lost for any reason. Other turn-off modes provide
more warning time. This pin is an open-drain output. It can be configured as a P-channel pull-up or an
N-channel pull-down. It may also be configured as positive or negative (inverted) logic.
The AC_OK function advises the system whether or not sufficient bulk voltage is present to allow
reliable operation. The system may choose to shut down if this pin is false. The power supply normally
tries to maintain normal operation as long as possible, although DC_OK goes false when only a
millisecond or so of operation time is left. This pin is an open-drain output. It can be configured as a
P-channel pull-up or an N-channel pull-down. It may also be configured as positive or negative
(inverted) logic.
The DC_OK output is kept false for typically 100 ms to 900 ms during power-up.
When the system is to be shut down in response to PSON going low, or in response to an OCP or OTP
event, a signal is first sent to the DC_OK output to go false as a warning that power is about to be lost.
PEN is signaled false typically 2 ms later (configurable).
All of the inputs to the logic core are first debounced or digitally filtered to improve noise immunity.
The debounce period for OV events is in the order of 16 µs, for UV events it is 450 µs, and for PSON it is
typically 80 ms (configurable).
A voltage from the secondary of the power transformer, which can provide an analog of the bulk
supply, is rectified and lightly filtered and measured by the ac sense function. At start-up, if this
voltage is adequate, this function signals the end user system that it is okay to start. If a brown-out
occurs or ac power is removed, this function can provide early warning that power is about to be lost
and allow the system to shut down in an orderly manner. While ACSENSE is low, UVB is enabled, which
means undervoltage protection is not initiated. If ac power is so low that the converter cannot
continue to operate, other protection circuits on the primary side normally shut down the converter.
When an adequate voltage level is resumed, a power-up cycle is initiated.
Rev. A | Page 17 of 64
ADM1041
Mnemonic
Pulse_OK
AC Hysteresis
ACSENSE2
Soft-start
VDD–OVP
VDD–UVL
AutoRestart Mode
VREF–MON
GND–MON
Description
As well as providing ac sense, the preceding connection to the transformer is used to gate the
operation of the OrFET circuit. If the output of the transformer is good and has no problems, the
OrFET circuit allows gate drive to the OrFET.
AC Sense Hysteresis. Configurable voltage on the ac sense input allows the ac sense upper and lower
threshold to be adjusted to suit different amounts of low frequency ripple present on the bulk
capacitor.
An alternate form of ac sense can be accepted by the ASIC. This may in the form of an opto-coupled
signal from the primary side where the actual level sensing might be done. As with the above, while
ac is low and UVB is disabled, AC_OK is false and DC_OK is true. Any brownout protection that might
be required on the primary is done on the primary side.
At start-up, the voltage reference to the voltage error amplifier is brought up slowly in approximately
127 steps to provide a controlled rate of rise of the output voltage.
An OVP fault on the auxiliary supply to the ASIC causes a standard OVP operation (see the OVP
function).
A UVL fault on the auxiliary supply to the IC causes a standard UVP operation (see the UVP function).
In this mode, the housekeeping circuit attempts to restart the supply after an undervoltage event at
about 1 second intervals. No other fault can initiate auto-restart.
The internal precision reference is monitored by a separate reference for overvoltage and allows truly
redundant OVP. The externally available reference is also monitored for an undervoltage that would
indicate a short on the pin.
The internal ASIC ground is constantly monitored against the remote sense negative pin. If the chip
ground goes positive with respect to this pin, it indicates that the chip ground is open-circuit either
inside the ASIC or the external wiring. The ASIC would be latched off, similar to an OV event.
Rev. A | Page 18 of 64
ADM1041
THEORY OF OPERATION
POWER MANAGEMENT
This block contains VDD undervoltage lockout circuitry and a
power-on/reset function. It also provides precision references
for internal use and a buffered reference voltage, VREF. If VREF is
configured to an output pin, overloading, shorting to ground, or
shorting to VDD do not effect the internal references. See Figure 8.
During power-on, VREF does not come up until VDD exceeds the
upper UVL threshold. Housekeeping functions in this block
include reference voltage monitors, VDD overvoltage, and a
ground fault detector.
The ground fault detector monitors ADM1041 ground with
respect to the remote sense pin VS−. If GND becomes positive
with respect to VS− an on-chip signal, VDDOK, goes false. VDDOK
is true only when all the following conditions are met: ground is
negative with respect to VS−, INTREF and EXTREF are operating
normally, VDD > UVLHI, and VDD < VDD OVP threshold.
GAIN TRIMMING AND CONFIGURATION
The various gain settings and configurations throughout the
ADM1041 are digitally set up via the SMBus after it has been
loaded onto its printed circuit board. There is no need for
external trim potentiometers. An initial adjustment process
should be carried out in a test system. Other adjustments such
as current sense and voltage calibration should be carried out in
the completed power supply.
VREF 18
VDD 1
INTERNAL
REFERENCE
2.5V
MAIN
BAND GAP
1.25V
EXTREFOK
REFERENCE
MONITOR
INTREFOK
AUXILIARY
REFERENCE
2.0V
POR
4.0V
UVLLO
RESET
S
4.4V
VDDOK
UVLHI
6.0V–6.5V
R
Q
S
Q
R
Q
OVP
VDDOV
10µs–20µs
GROUND
MONITOR
GNDOK
04521-0-006
0.2V
VS– 20
GND 7
gndok_dis
Figure 8. Block Diagram of Power Management Section
Rev. A | Page 19 of 64
ADM1041
DIFFERENTIAL REMOTE SENSE AMPLIFIER
LOCAL OVERVOLTAGE PROTECTION (OVP)
This amplifier senses the load voltage and is the main voltage
feedback input. A differential input is used to compensate for
the voltage drop on the negative output cable of the power
supply. An external voltage divider should be designed to set the
VS+ pin to approximately 2.0 V with respect to VS–. The amplifier
gain is 1.0. See Figure 9.
This is the main overvoltage detection for the power supply. It is
detected locally so that only the faulty power supply shuts down
in the event of an OVP condition in an N+1 redundant power
system. This occurs only after a load OV event. The local OVP
threshold may be trimmed via the SMBus. See Figure 9.
SET LOAD VOLTAGE
This is the main undervoltage detection for the power supply. It
is also detected locally so that a faulty power supply can be
detected in an N+1 redundant power system. The local UVP
threshold may be trimmed via the SMBus. See Figure 9.
LOCAL UNDERVOLTAGE PROTECTION (UVP)
The load voltage may be trimmed via the SMBus by a trim stage
at the output of the differential remote sense amplifier. The
voltage at the output of the trimmer is 1.50 V when the voltage
loop is closed. See Figure 9.
FALSE UV CLAMP
LOAD OVERVOLTAGE (OV)
If a faulty power supply causes an OVP condition on the system
bus, the control loops in the good power supplies is driven to
zero output. Therefore, a means is required to prevent the good
power supplies from indicating an undervoltage, and they must
recover quickly after the faulty power supply has shut down.
The false UV clamp achieves this by clamping the output voltage
just above the local UVP threshold. It may be trimmed via the
SMBus. The OCPF signal disables the clamp during overcurrent
faults. See Figure 9.
A comparator at the output of the load voltage trim stage
detects load overvoltage. The load OV threshold can be
trimmed via the SMBus. The main purpose is to turn off the
OrFET when the load voltage rises to an intermediate overvoltage level that is below the local OVP level. This circuit is not
latching. See Figure 9.
LOCAL VOLTAGE SENSE
This amplifier senses the output voltage of the power supply just
before the OrFET. Its input is derived from one of the pins used
for current sensing and is set to 2.0 V by an external voltage
divider. The amplifier gain is 1.3. See Figure 9.
VS–
21
REMOTE
SENSE
FROM
LOAD
35kΩ
35kΩ
70µA
20
35kΩ
VS+
CURRENT LIMIT
35kΩ
SET LOAD
VOLTAGE
25kΩ
DIFF. VOLTAGE SENSE
CURRENT SHARE
1V
3V
VOLTAGE
ERROR AMP
CAPTURE
VCMP
5
SET LOAD
OVERVOLTAGE
LOADVOK
VLS 2
VREF
1.5V
1.25V
×1.3
OCPF
SOFTSTART
RAMP UP
FALSE UV
CLAMP
SET UV CLAMP
THRESHOLD
SET OVP
THRESHOLD
OVP
TO
GENERAL
LOGIC
UVP
TO
GENERAL
LOGIC
1.5V
NOTE:
ALL POTENTIOMETERS (
04521-0-032
SET UVP
THRESHOLD
) ARE DIGITALLY PROGRAMMABLE THROUGH REGISTERS.
Figure 9. Block Diagram of Voltage Sense Amplifier
Rev. A | Page 20 of 64
ADM1041
70
VOLTAGE ERROR AMPLIFIER
60
CURRENT (µA)
50
40
30
20
0
04521-0-039
10
0
1
2
VOLTAGE (V)
3
4
Figure 10. Current Limit
MAIN VOLTAGE REFERENCE
2.75
A 1.5 V reference is connected to the inverting input of the
voltage error amplifier. This 1.5 V reference is the output voltage
of the soft-start circuit. Under closed-loop conditions, the
voltage at the noninverting input is also controlled to 1.5 V.
During start-up, the output voltage should be ramped up in a
linear fashion at a rate that is independent of the load current.
This is achieved by digitally ramping up the reference voltage by
using a counter and a DAC. The ramp rate is configurable via
the SMBus. See Figure 14.
2.50
2.25
2.00
GM (mA/V)
1.75
1.50
1.25
1.00
0.75
04521-0-040
0.50
0.25
0
1
10
100
1k
10k
100k
BANDWIDTH
1M
10M
100M
10M
100M
Figure 11. VCMP Transconductance
220
200
180
160
120
100
80
60
40
04521-0-041
GM (µA/V)
140
20
0
This is a high gain transconductance amplifier that takes its
input from the load voltage trim stage described previously. The
amplifier requires only the output pin for loop compensation,
which typically consists of a series RC network-to-common. A
parallel resistor may be added to common to reduce the openloop gain and thereby provide some output voltage droop as
output current increases. The output of the amplifier is typically
connected to an emitter follower that drives an optocoupler,
which in turn controls the duty of the primary side PWM. The
emitter follower should have a high gain to minimize loading
effects on the amplifier. Alternatively, an op amp voltage
follower may be used. See Figure 9, Figure 10, and Figure 11.
1
10
100
1k
10k
100k
BANDWIDTH
1M
Figure 12. CCMP and SCMP Transconductance
CURRENT SENSE AMPLIFIER
This is a two-stage differential amplifier that achieves low offset
and accuracy. The amplifier has the option to be chopped to
reduce offset or left as a linear amplifier without chopping.
Refer to the Register Listing for more details. Its gain may be
selected from three ranges. It is followed by a trim stage and
then by a low gain buffer stage that can be configured with a
gain of 1.0 or 2.1. The result is a total of six overlapping gain
ranges (65 to 230), one of which must be selected via the SMBus.
This gives ample adjustment to compensate for the poor initial
tolerance of the resistance wires typically used for current
sensing. It also allows selecting a higher sensitivity for better
efficiency or a lower sensitivity for better accuracy (lower offset).
The amplifier offset voltage is trimmed to zero in a once-off
operation via the SMBus and uses a voltage controlled current
source at the output of the first gain stage. A second controlled
current source is used to trim out the additional offset due to
the mismatch of the external divider resistors. This offset trim is
dynamically adjusted according to the common-mode voltage
present at the top of the voltage dividers. Six ranges are selectable
according to the magnitude and polarity of this offset component.
Because the offset compensation circuit itself has some inaccuracies, the best overall current sense accuracy is obtained by
using more closely matched external dividers and then selecting
a low compensation range. See Figure 14.
Rev. A | Page 21 of 64
ADM1041
CURRENT SENSING
CURRENT SENSE CALIBRATION
Current is typically sensed by a low value resistor in series with
the positive output of the power supply, just before the OrFET
or diode. For high voltages (12 V and higher), this resistor is
usually placed in the negative load. A pair of closely matched
voltage dividers connected to Pins 2 and 3 divide the commonmode voltage down to approximately 2.0 V. The divider ratio
must be the same as used in the local and remote voltage sense
circuits. Alternatively, current may be sensed by a current
transformer (CT) connected to Pin 8. The ADM1041 must be
configured via the SMBus to select one or the other. See
Figure 13.
Regardless of which means is used to sense the current, the end
result of the calibration process should produce the standard
current share signal between Pins 20 and 23, that is, 2.0 V at
100% load, excluding any additional share signal offset that
might be configured.
CURRENT TRANSFORMER INPUT
The ADM1041 can also be configured to sense current by using
a current transformer (CT) connected to Pin 8. In this case, the
resistive current sense is disabled. A separate single-ended
amplifier has two possible sensitivities that are selected via the
SMBus. If the CT option is selected, the gain of the 1.0, 2.1
buffer that follows the gain trim stage is no longer configurable
and is fixed at 1.0.
The share driver amplifier has a total of 100 mV positive offset
built into it. In order to use the ADM1041 in CT mode, it is
necessary to compensate for this additional 100 mV offset. This
is achieved by adding in a positive offset on the CT input. This
also allows any negative amplifier offsets in the CT chain to be
nulled out.
This offset cancellation is achieved by sourcing a current
through a resistance on the ICT pin. The resistor value is 40 kΩ
and so for 100 mV of offset cancellation a current of 2.5 µA is
required. It is possible to fine trim this current via Register 15h,
Bits 4–0, step size 170 nA. For example, 2.5 µA ≈ 15 × 170 nA;
so the code for Register 15h is decimal 15 or 0Fh. Refer to the
Current Transformer parameter in the Specifications table for
more details. See Figure 13.
CURRENT LIMIT ERROR AMPLIFIER
This is a low gain transconductance amplifier that takes its
input from one of the calibrated current stages described
previously. The amplifier requires only the output pin for loop
compensation, which typically consists of a series RC network
to common. A trimmable reference provides a wide range of
adjustment for the current limit. When the current signal
reaches the reference voltage, the output of the error amplifier
comes out of saturation and begins to drive a controlled current
source. The control threshold is nominally 1.0 V. This current
flows through a resistor in series with the trimmed voltage loop
signal and thereby attempts to increase the voltage signal above
the 1.5 V reference for that loop. The closed voltage loop reacts
by reducing the power supply’s output voltage and this results in
constant current operation. See Figure 13.
OVERCURRENT PROTECTION
When the current limit threshold is reached, the OCP
comparator detects when the current error amplifier comes out
of saturation. Its threshold is nominally 0.5 V. This starts a timer
that, when it times out, causes an OCP condition to occur and
the power supply to shut down. If the current limit disappears
before the time has expired, the timer is reset. The time period
is configurable via the SMBus. Undervoltage blanking is applied
during the timer operation. See Figure 14.
Rev. A | Page 22 of 64
Figure 13. Current Sense
Rev. A | Page 23 of 64
04521-0-033
CURRENT
TRANSFORMER
TRANSFORMER
CURRENT
SENSE
CONFIGURATION
CS+
CCMP
ICT
CS–/FS
CURRENT
4
8
2
3
40kΩ
GAIN = 10
OrFET SOURCE
OrFET GATE
REG 17h b7
SET GAIN
IRS/ICT
0.5V
1.25V
SET
CURRENT
SHARE
OCP
COMPARATOR
R
VDD
VREF
VREF
SET CURRENT
LIMIT LEVEL
CURRENT
SHARE
OFFSET
(VSHARE,
IOUT = 0)
CURRENT
LIMIT TO
VOLTAGE
ERROR AMP
OCP
CURRENT
ERROR AMP
9R
TO CURRENT
SHARE DRIVE
AMPLIFIER
ADM1041
ADM1041
CURRENT SHARE
The current share method is the master–slave type, which
means that the power supply with the highest output current
automatically becomes the master and controls the share bus
signal. All other power supplies become slaves, and the share
bus signal causes them to increase their output voltages slightly
until their output currents are almost equal to that of the master.
This scheme has two major advantages. A failed master power
supply simply allows one of the slaves to become the new
master. A short circuited share signal disables current sharing,
but all power supplies default to their normal voltage setting,
allowing a certain degree of passive sharing. Because this chip
uses a low voltage process, an external bidirectional amplifier is
needed for most existing share bus signal levels. The voltage
between Pins 20 and 23 is always controlled to 2.0 V full scale,
ignoring any offset. By connecting Pins 20 and 23 together, the
chip can produce a 2.0 V share signal directly without any external circuits. To improve accuracy, the share signal is referenced
to remote voltage sense negative.
ISHARE ERROR AMPLIFIER
To satisfy some customer specifications, the current share signal
can be offset by a fixed amount by using a trimmable current
generator and a series resistor. The offset is added on top of the
2.0 V full-scale current share output signal. See Figure 14.
This is a low gain transconductance amplifier that measures the
difference between the internal current share voltage and the
signal voltage on the external share bus. If two power supplies
have almost identical current share signals, a 50 mV voltage
source on the inverting input helps arbitrate which power
supply becomes the master and prevents “hunting” between
master and slave roles. The amplifier requires only the output
pin for loop compensation, which typically consists of a series
RC network to common. When the power supply is a slave, the
output of the error amplifier comes out of saturation and begins
to drive a controlled current sink. The control threshold is
nominally 1.0 V. This current flows from a resistor in series with
the trimmed voltage loop signal and thereby attempts to decrease
the voltage signal below the 1.5 V reference for that loop. The
closed voltage loop reacts by increasing the power supply’s
output voltage until current share is achieved. The maximum
current sink is limited so that the power supply voltage can be
increased only a small amount, which is usually limited to be
within the customer’s specified voltage regulation limit. This
small voltage increase also limits the control range of the current
share circuit and is called the capture range. The capture range
may be set via the SMBus to one of four values, from 1% to 4%
nominal. See Figure 14.
ISHARE DRIVE AMPLIFIER
ISHARE CLAMP
This amplifier is a buffer with enough current source capability
to drive the current share circuits of several slave power supplies.
It has negligible current sink capability. Refer to the Differential
Sense Amplifier section that follows.
This clamp keeps the current share-loop compensation capacitor
discharged when the current share is not required to operate.
The clamp is released during power-up when the voltage reference and therefore the output voltage of the power supply has
risen to either 75% or 88% of its final value. This is configurable
via the SMBus. When the clamp is released, the current share
loop slowly “walks in” the current share and helps to avoid
output voltage spikes during hot swapping. See Figure 14.
CURRENT SHARE OFFSET
DIFFERENTIAL SENSE AMPLIFIER
This amplifier has unity gain and senses the difference between
the share bus voltage and the remote voltage sense negative pin.
When the power supply is the master, it forms a closed loop
with the ISHARE drive amplifier described above, and therefore it
causes the share bus voltage between Pins 20 and 23 to equal the
current share signal at the noninverting input of the ISHARE drive
amplifier. When the power supply is a slave, the output of the
differential sense amplifier exceeds the internal current share
signal, which causes the ISHARE drive amplifier to be driven into
cutoff. Because it is not possible to trim out negative offsets in
the op amps in the current share chain, a 50 mV voltage source
is used to provide a known fixed positive offset. The share bus
offset controlled current source must be trimmed via the
SMBus to take out the resulting overall offset. See Figure 14.
Share_OK DETECTOR
Incorrect current sharing is a useful early indicator that there is
some sort of non-catastrophic problem with one of the power
supplies in a parallel system. Two comparators are used to detect
an excessive positive or negative error voltage at the input of the
ISHARE error amplifier, which indicates that the current share
loop has lost control. One of four possible error levels must be
configured via the SMBus. See Figure 14.
Rev. A | Page 24 of 64
04521-0-034
FROM
CURRENT
SENSE
R
VDD
VREF
VREF
SET CURRENT
LIMIT LEVEL
CURRENT
SHARE
OFFSET
(VSHARE,
IOUT = 0)
CURRENT
ERROR AMP
9R
SHAREOK
Rev. A | Page 25 of 64
Figure 14. Current Share Circuit and Soft-start
CURRENT SHARE
DIFF. VOLTAGE SENSE
CURRENT LIMIT
50mV
3V
70µA
VREF
ISHARE
CLAMP
60µA
VOLTAGE
ERROR AMP
SOFT
START
RAMP UP
CAPTURE
1V
50mV
DIFFERENTIAL
SENSE
ISHARE DRIVE
AMPLIFIER
ISHARE ERROR
AMPLIFIER
TO VOLTAGE ERROR AMP
5
20
23
24
22
+12V
VCMP
GAIN = (R1+R2)/R2
VS–/SHRS–
SHRS+
SHRO
SCMP
R2
R1
REMOTE
–VE SENSE
1N4148
GAIN = (R1 + R2)/R2
SHARE BUS
ADM1041
ADM1041
3V
2V
VSHARE
1V
0
20
40 60
IOUT
80 100%
04521-0-010
OFFSET
0
Figure 15. Load Share Characteristic
Rev. A | Page 26 of 64
ADM1041
PULSE/ACSENSE2
When configured, PULSE and ACSENSE monitor the output of
the power main transformer. See Figure 16.
PULSE
Providing the output of the pulse function (PULSE_OK) is
high, the FET in the ORing circuit can be turned on. If the
pulses stop for any reason, about 1 second later the PULSE_OK
goes low and the OrFET drive is disabled. This delay allows
passage of all expected pulse skipping modes that might occur
in no load or very light load situations. See Figure 16.
ACSENSE
This is rarely used to measure directly the ac input to the supply.
ACSENSE1 or ACSENSE2 are usually used to indirectly measure the
voltage across the bulk capacitor so that the system can be
signaled that power is normal. Also if power is actually lost,
ACSENSE represents when just enough energy is left for an orderly
shutdown of the power supply. See Figure 16.
The ac sense function monitors the amplitude of the incoming
pulse and, if sufficiently high, generates a flag to indicate ac, or
strictly speaking, the voltage on the bulk capacitor, is okay. Since
the envelope of the pulse has a considerable amount of 100 Hz
ripple, hysteresis is available on this input pin. Internally there is
a 20 µA to 80 µA current sink. With a 909R external thevenin
resistance, this current range translates to a voltage hysteresis of
200 mV to 500 mV. The internal hysteresis current is turned off
when the voltage exceeds the reference on the comparator. This
form of hysteresis allows simple scaling to be implemented by
changing the source impedance of the pulse conditioning
circuit. Some trimming of hysteresis and threshold voltage is
provided. The ac sense function can be configured to be derived
from ACSENSE2 rather than ACSENSE1. This allows a separate dc
input from various locations to be used to generate AC_OK for
better flexibility or accuracy.
TO OrFET SOURCE
TO CURRENT
SENSE RESISTOR
AND OrFET GATE
0.525V
S
9
PULSE
ACSENSE1
5.3kΩ
R
CLK
Q
1 SEC
Q
PULSEOK
R
SELECT
ACSENSE
AC_OK
1.5V
S
5.3kΩ
R
CLK
Q
1 mS
TRIM
HYSTERESIS
Figure 16. Pulse In and AC Sense Circuit
Rev. A | Page 27 of 64
Q
R
04521-0-035
ACSENSE2 10
ADM1041
OrFET GATE DRIVE
When configured, this block provides a signal to turn on/off an
OrFET used in the output of paralleled power supplies. The gate
drive voltage of one of these FETs is typically 6 V to 10 V above
the output voltage. Since the output voltage of the ADM1041 is
limited, an external transistor needs to be used. The block
diagram shows an example of this approach. See Figure 21.
A differential amplifier monitors the voltage across the OrFET
and has two major functions. First, during start-up, it allows the
OrFET to turn on with almost 0 V across it to avoid voltage
glitches on the bus. This applies to a hot bus or a cold bus. The
internal threshold can be configured from 20 mV to 50 mV
(negative), which is scaled up by the external voltage dividers.
TTOTAL = 330ns
64%
TDELAY = 218ns T = 112ns
04521-0-042
The FG output is an open-drain, N-channel MOSFET and is
normally high, which holds the OrFET off. When all the startup conditions are correct, Pin 19 is pulled low, which allows the
OrFET to turn on. The logic can also be configured as inverted
if a noninverting drive circuit is used.
Figure 17. OrFET Turn-Off Time (Default Polarity)
Second, if a rectifier or filter capacitor fails during steady state
operation, it detects the resulting reverse voltage across the
OrFET’s on-resistance and turns off the OrFET before a voltage
dip appears on the bus. The internal threshold can be configured
from 100 mV to 250 mV (negative), which is also scaled up by
the external voltage dividers. A slightly larger filter capacitor
may be used on the voltage divider at Pin 6 to speed up this
function.
Figure 19 and Figure 20 show the OrFET turn-off time and
turn-on time when the FG pin polarity is inverted. As can be
seen, to turn off the OrFET, the VFG pin now transitions from
high to low. Also, its corresponding turn-on event occurs from a
low-to-high transition. The circuit in Figure 21 is used to
generate these plots.
Rev. A | Page 28 of 64
TTOTAL = 506ns
04521-0-013
Figure 17 shows the typical response time of the ADM1041 to
such an event. In the plot, VFD is ramped down and the response
time of the FG pin to a reverse voltage event on the FD pin is
seen. This simulates the rectifier or filter capacitor failure
during steady state operation. When the FD voltage is below
1.9 V (2 V minus 100 mV threshold), the FG pin reacts. As can
be seen, the response time is approx 330 nsecs. This extremely
fast turn-off is vital in an n+1 power supply system configuration.
It ensures that the damaged power supply removes itself from
the system quickly. Figure 18 is the equivalent response time to
turn on the OrFET. As can be seen, there is a delay of approximately 500 ns before the FG pin ramps down to turn on the
OrFET, and therefore allow the power supply to contribute to the
system. This propagation delay is due mainly to internal amplifier
response limitations. The circuit in Figure 21 is used to generate
these plots. In this case, the resistor to VDD from the FG pin is
2 kΩ.
Figure 18. OrFET Turn-On Time (Default Polarity)
ADM1041
TTOTAL = 618ns
04521-0-043
TTOTAL = 222ns
TDELAY = 506ns
04521-0-044
64%
T = 112ns
Figure 20. OrFET Turn-On Time (Inverse Polarity)
Figure 19. OrFET Turn- Off Time (Inverse Polarity)
CURRENT
VOUT
SOURCE
GATE
V = VOUT +10V
6
VDD
FD
PULSEOK
19
FG
LOADOK
PENOK
REVERSEOK
OrFET OK
RESET
VOLTAGE
DETECTOR
POLARITY
VREF
04521-0-036
2
FS
Figure 21. OrFET Gate Drive Circuit
Rev. A | Page 29 of 64
DRAIN
ADM1041
OSCILLATOR AND TIMING GENERATORS
An on-board oscillator is used to generate timing signals. Some
trimming of the oscillator is provided to adjust for variations in
processing.
All timing generated from the oscillator is expected to meet the
same tolerances as the oscillator. Since individual delay counters
are generally two to three bits, the worst error is one clock period
into these counters, which is 25% of the nominal delay period.
None of these tolerances are extremely critical.
MON1
This is the alternative analog comparator function for the
Pulse/ACSENSE1 pin (Pin 9). The threshold is 1.25 V. When
MON1 is selected, ACSENSE1 defaults to true.
MON2
This is the alternative analog comparator function for the
ACSENSE2 pin (Pin 10). The threshold is 1.25 V. When MON2 is
selected, ACSENSE2 defaults to true.
PEN
LOGIC I/O AND MONITOR PINS
Apart from pins required for the various key analog functions, a
number of pins are used for logic level I/O signals. If the logic
I/O function is not required, the pins may be reconfigured as
general-purpose comparators for analog level monitoring (MON)
and may be additionally configured to have typical OVP and
UVP properties, either positive-going or negative-going,
depending on whether a positive supply output or a negative
supply output is being monitored. When monitoring negative
outputs, a positive bias must be applied via a resistor to VREF.
The status of all protection and monitoring comparators are
held in registers that can be read by a microprocessor via the
SMBus. Certain control bits may be written to via the SMBus.
This is the power enable pin that turns the PWM converter on
and can be configured as active high or low. This might drive an
opto-isolator back to the primary side or connect to the enable
pin of a secondary-side post regulator.
PSON
This pin is usually connected to the customer’s PSON signal
and, when asserted, causes the ADM1041 to turn on the power
output. It can be configured as active high or low. Alternatively,
a microprocessor can communicate the PSON function to the
ADM1041 using the SMBus. Or the PSONLINK signal may be
used. When the PSON pin is not used as such it can be
configured as an analog input, MON3.
CBD/ALERT
MON3
This pin can be used either as a crowbar driver or as an SMBus
alert signal to indicate that a fault has occurred. It is typically
configured to respond to a variety of status flags, as detailed in
Registers 1Ah and 1Bh. The primary function of this pin is as a
crowbar driver, and as such it should be configured to respond
to the OV fault status flag. It can be configured to respond to
any or all of a variety of fault status flags, including a microprocessor writable flag, and can be configured as latching or
nonlatching. It may also be configured as an open-drain
N-channel or P-channel MOSFET and as positive or negative
(inverted) logic. A pull-up or pull-down resistor is required.
This pin may be wire-ORed with the same pin on other
ADM1041 ASICs in the power supply.
This is the alternative analog comparator function for the PSON
pin (Pin 16). The threshold is 1.25 V. When MON3 is selected,
PS ON defaults to off.
The alternative function is an SMBus alert output that can be
used as an interrupt to a microprocessor. If a fault occurs, the
microprocessor can then query the ADM1041(s) about the fault
status. This is intended to avoid continuously polling the
ADM1041(s).
MON4
Generally, the microprocessor needs to routinely gather other
data from the ADM1041(s), which can include the fault status,
so the ALERT function may not be used. Also, the simplest
microprocessors may not have an interrupt function. This
allows the CBD/ALERT pin to be used for other functions.
DC_OK (PW-OK, PWR Good, Etc.)
This output is true when all dc output voltages are within tolerance and goes false to signify an imminent loss of power. Timing
is discussed later. It can be configured as an open-drain Nchannel or P-channel MOSFET and as positive or negative
(inverted) logic. A pull-up or pull-down resistor is required.
This pin may be wire-ORed with the same pin on other
ADM1041 ASICs in the power supply. When the DC_OK pin is
not used as such, it can be configured as an analog input,
MON4.
This is the alternative analog comparator function for the
DC_OK pin (Pin 17). The threshold is 1.25 V.
VREF
This pin normally provides a precision 2.5 V voltage reference.
Alternatively, it can be configured as the AC_OK output or as
an analog input, MON5. A load capacitance of 1 nF (typ) is
recommended on VREF.
Rev. A | Page 30 of 64
ADM1041
AC_OK
+5V
This output is true when either ACSENSE1 or ACSENSE2 is true
(configurable). It can be configured as an open-drain N-channel
or P-channel MOSFET and as positive or negative (inverted)
logic. A pull-up or pull-down resistor is required. This pin can
be wire-ORed with the same pin on other ADM1041 ASICs in
the power supply. When the AC_OK pin is not used as such, it
can be configured as an analog input, MON5, or as a voltage
reference.
1
VCC
MON2 10
MON3 16
THERMISTOR
7
MON5
This is the alternative analog comparator function for the
AC_OK/VREF pin (Pin 18). The threshold is 2.5 V, and it has a
100 µA current source that allows hysteresis to be controlled by
adjusting the external source resistance. It is ideal for an OTP
sensing circuit using a thermistor as part of a voltage divider.
The OTP condition can be configured to latch off the power
supply (similar to OVP) or to allow an auto-restart (soft OTP).
See Figure 22.
04521-0-016
–12V
MON5 18
Figure 22. Example of MON Pin Configuration
In the preceding example, MON2 and MON3 are configured to
monitor a negative 12 V rail. MON2 is configured as negative
going OVP, and MON3 is configured as positive going UVP.
The 5 V power rail is used for bias voltage.
OCP
2.5V
2.5V
OCP
18
OTP/
MON5
9
MON1
MON5
1.25V
1.5V
MON1
OVP
OVP
10 MON2
MON2
UVP
UVP
16 MON3
GENERAL
LOGIC
17 MON4
ACOK
ORFETOK
ORFETOK
SHAREOK
SHAREOK
RESET
RESET
VDDOK
VDDOK
VDDOV
VDDOV
PENOK
PENOK
MON4
16 PSON
PSON
CLOCK
VREF
AC_OK
DC_OK
CBD
CONTROL
REGISTERS
PEN
18 VREF
18 AC_OK
17 DC_OK
11 CBD/ALERT
12 PEN
CONFIGURE
I/Os
CONFIGURE
STATUS
(WRITE
(READ
REGISTERS) REGISTERS)
PWRON
SDA/
CONTROL
SERIAL
LINES
INTERFACE
PEN
14 PS LINK
ON
SCL
13 SCL/
CS
Figure 23. Block Diagram of Protection and General Logic
Rev. A | Page 31 of 64
AC_OKLink
15 ADD0
04521-0-014
ACOK
MON3
CONFIG
Figure 24. General Logic
Rev. A | Page 32 of 64
OCP
curr_lim_dis
0.5V
04521-0-015
COMP
(4)
FROM OUTPUT
OF CURRENT
ERROR AMP
rsm
PSON3/
MON3
(12)
CONFIG
mn3s
ACSENSE2/
MON2
(10)
mn2s
CONFIG
mn1s
ACSENSE1/
MON1
(9)
OCPF
up_pson_m
mov5
80ms
UV BLANK
450µs
UV DEBOUNCE
ovfault
selcbd1<7>
selcbd2<6>
selcbd1<6>
vddov
local ov
selcbd2<7>
vddok
mfg1
selcbd2<5>
mfg2
selcbd2<4>
mfg3
selcbd2<3>
mfg4
uvfault
ocpto
selcbd1<4>
acsns
selcbd1<3>
ocpf
m_cbd_w
selcbd2<2>
opt(mov5)
selcbd1<2>
mfg5
selcbd2<1>
orfetok
selcbd1<1>
NOT USED
selcbd2<0>
FAULT
FAULTB
SDA/
PSONLINK
(14)
SCL/
AC_OKLink
(13)
SOFT
START
RAMP
m_cbd_cir
DC_OK ON DELAY
m_shr_clmp
VREF
1.5V
VOLTAGE
ERROR AMP
m_dcok_r
por
D
R
S
Q
cbdlm
DRIVER
VCMP
(5)
DRIVER
polcbd
DC_OK/
MON4
(17)
PEN
(12)
SCMP
(22)
error_amp
inv input
GM
DRIVER
polpen
clamp
poldcok, mn4s0
m_penok_r
75%/88%
SOFT
START VOUT
DAC
scmp_in
300µs, 10ms, 20ms, 40ms
ssr1s1, ssrs0
set_cshare_clamp
200, 400, 800, 1600ms
POKTS1, POKTS0
gatepen
R
S Q
shareok
R Q
S Q
vddok
gateramp
sda_out
sda_in
scl_in
selcbd1<0>
acsok
selcbd1<5>
ovfault
ocfault
uvfault
uvbm
i2cmb
mov4
penon
uvok
psonlink
m_psonok_r
acsns
mov3
mov2
mov1
OCP RIDETHROUGH
128, 256, 384, 512µs,
OR 1, 2, 3, 4SEC
softotp
OCP
DISABLE
localuv
muv5
muv4
muv3
muv2
muv1
R
ocpts2, ocpts1, ocpts0
dcokoff_delay
Q S
psonts1.psonts0
m_acsns_w
0, 40, 80, 160ms
DC_OK OFF DELAY
0, 1, 2, 4ms
1 SECOND
softotp
mov5
m_pson_r
m_pson_w
DEBOUNCE
1ms
restartb
ACSENSE
acsns_hyst
acsns_thresh
acss
CBD/
ALERT
(11)
ADM1041
ADM1041
SMBus SERIAL PORT
MICROPROCESSOR SUPPORT
The programming and microprocessor interface for the
ADM1041 is a standard SMBus serial port, which consists of a
clock line and a data line. The more rigorous requirements of
the SMBus standard are specified in order to give the greatest
noise immunity. The ADM1041 operates in slave mode only. If a
microprocessor is not used, these pins can be configured to
perform the PSONLINK and AC_OKLink functions. Note that
this port is not intended to be connected to the customer’s
SMBus (or I2C bus). Continuous SMBus activity or an external
bus fault interferes with the inter-ASIC communication, possibly
preventing proper operation and proper fault reporting. If the
customer needs status and control functions via the SMBus, it is
recommended that a microprocessor with a hardware SMBus
(I2C) port be used for this interface. The microprocessor should
access the ASICs via a second SMBus port, which may be emulated in software (subset of the full protocol).
The ADM1041 has many features that allow it to operate with
the aid of a microprocessor. There are several reasons why a
microprocessor might be used:
•
To provide unusual logic and/or timing requirements,
particularly for fault conditions.
•
To drive one or more LEDs, including flashing, according
to the status of the power supply.
•
To replace other discrete circuits such as multiple OTP,
extra output monitoring, fan speed control, and failure
detection, and combine the status of these circuits with the
status of the ADM1041s.
•
To free up some pins on the ADM1041s. This could reduce
the number of ASICs and therefore the cost.
•
To interface to an external SMBus (or I2C) for more
detailed status reporting. The SMBus port in the ADM1041
is not intended for this purpose.
•
To allow EEPROM space in ADM1041(s) or in the
microprocessor to be used for FRU (VPD) data. A simple
or complex microprocessor can be used according to the
amount of additional functionality required. Note that the
microprocessor is not intended to access or modify the
EEPROM address space that is used for the configuration
of the ADM1041(s).
SDA/PSONLINK
The SDA pin normally carries data in and out of the ASIC
during programming/configuration or while reading/writing by
a microprocessor. If a microprocessor is not used, this pin can
be configured as PSONLINK and can be connected to the same
pin on other ADM1041s in the power supply. If a fault is
detected in any ADM1041, causing it to shut down, it uses this
pin to signal the other ADM1041s to also shut down. If an autorestart has been configured, it also causes all ADM1041s to turn
on together.
Interfacing
SCL/AC_OKLink
The SCL pin normally provides a clock signal into the ASIC
during programming/configuration or while reading/writing by
a microprocessor. If a microprocessor is not used, this pin can
be configured as AC_OKLink, and can be connected to the
same pin on other ADM1041s in the power supply. This allows
a single ADM1041 to be used for ac sensing and helps to
synchronize the start-up of multiple ADM1041s.
ADD0
This pin configures two bits of the chip address for the SMBus.
It is three-level and can be pulled high to VDD, pulled low to
ground, or left floating (internally biased to 2.5 V). An additional
bit may be set during configuration, which allows up to six
ADM1041s to be used in a single power supply. The state of
ADD0 is continuously sampled after VDD power-up. After the
first time the ADM1041 is successfully addressed, the internal
bias is released and ADD0 becomes high impedance.
The microprocessor must access the ADM1041(s) via their
on-board SMBus (I2C) port. Since this port is also used for
configuration of the ADM1041(s), the software must include a
routine that avoids SMBus activity during the configuration
process. The simplest interface is for the microprocessor to have
an SMBus (I2C) port implemented in hardware, but this may be
more expensive. An alternative is to emulate the bus in software
and to use two general-purpose logic I/O pins. Only a simple
subset of the SMBus protocol need be emulated because the
ADM1041 always operates as a slave device.
Configuring for a Microprocessor
Except during initial configuration, all ADM1041 registers that
need to be accessed are high speed CMOS devices that do not
involve EEPROM. The Microprocessor Support table (Table 43)
details the various registers, bits, and flags that can be read and
written to, including explanations.
Note that for the microprocessor to gain control of the PSON
and ACSENSE functions, the normal signal path in the ADM1041
must be configured to be broken. A separate configuration bit is
allocated to each signal. The microprocessor can then write to
the signal after the break as though the signal originated within
the ADM1041 itself. The original signals can still be read prior
to the break.
Rev. A | Page 33 of 64
ADM1041
The peripheral whose address corresponds to the transmitted address responds by pulling the data line low during
the low period before the ninth clock pulse, known as the
Acknowledge bit, and holding it low during the high period
of this clock pulse. All other devices on the bus now remain
idle while the selected device waits for data to be read from
or written to it. If the R/W bit is a 0, then the master writes
to the slave device. If the R/W bit is a 1, the master reads
from the slave device.
BROADCASTING
In a power supply with multiple outputs, it is recommended that
all outputs rise together. Because the SMBus is relatively slow,
simply writing sequentially to the PSON signal in each ADM1041,
for instance, causes a significant delay in the output rise of the
last chip to be written. The ADM1041 avoids this problem by
allocating a common broadcast address that all chips can respond
to. To avoid data collisions, this feature should be used only for
commands that do not initiate a reply.
2.
SMBus SERIAL INTERFACE
Control of the ADM1041 is carried out via the SMBus. The
ADM1041 is connected to this bus as a slave device under the
control of a master device.
The ADM1041 has a 7-bit serial bus slave address. When the
device is powered up, it does so with a default serial bus address.
The default power-on SMBus address for the device is 1010XXX
binary, the three lowest address bits (A2 to A0) being defined by
the state of the address pin, ADD0, and Bit 1 of Configuration
Register 4 (ADD1). Because ADD0 has three possible states
(tied to VDD, tied to GND, or floating) and Config4 < 1 > can be
high or low, there are a total of six possible addresses, as shown
in Table 6.
If the operation is a write operation, the first data byte after
the slave address is a command byte. This tells the slave
device what to expect next. It may be an instruction such as
telling the slave device to expect a block write, or it may
simply be a register address that tells the slave where subsequent data is to be written.
GENERAL SMBus TIMING
Because data can flow in only one direction as defined by
the R/W bit, it is not possible to send a command to a slave
device during a read operation. Before doing a read operation, it might be necessary to first do a write operation to
tell the slave what sort of read operation to expect and/or
the address from which data is to be read.
The SMBus specification defines specific conditions for different
types of read and write operation. General SMBus read and
write operations are shown in the timing diagrams of Figure 25,
Figure 26, and Figure 27, and described in the following sections.
The general SMBus protocol operates as follows:
1.
The master initiates data transfer by establishing a start
condition, defined as a high-to-low transition on the serial
data line SDA while the serial clock line SCL remains high.
This indicates that a data stream will follow. All slave
peripherals connected to the serial bus respond to the start
condition and shift in the next 8 bits, consisting of a 7-bit
slave address (MSB first), plus a R/W bit, which determines
the direction of the data transfer, that is, whether data is
written to or read from the slave device (0 = write, 1 = read).
Data is sent over the serial bus in sequences of nine clock
pulses, eight bits of data, followed by an Acknowledge bit
from the slave device. Data transitions on the data line
must occur during the low period of the clock signal and
remain stable during the high period, because a low-tohigh transition when the clock is high may be interpreted
as a stop signal.
3.
When all data bytes have been read or written, stop
conditions are established. In write mode, the master pulls
the data line high during the tenth clock pulse to assert a
stop condition. In read mode, the master device releases
the SDA line during the low period before the ninth clock
pulse, but the slave device does not pull it low. This is
known as No Acknowledge. The master then takes the data
line low during the low period before the tenth clock pulse,
then high during the tenth clock pulse to assert a stop
condition.
Note: If it is required to perform several read or write
operations in succession, the master can send a repeat start
condition instead of a stop condition to begin a new operation.
Rev. A | Page 34 of 64
ADM1041
19
9
1
9
SCLK
A6
SDATA
A5
A4
A3
A2
A1
A0
R/W
START BY
MASTER
D6
D7
D5
D4
D3
D2
D1
D0
ACK. BY
ADM1041
ACK. BY
ADM1041
FRAME 2
ADDRESS POINTER REGISTER BYTE
FRAME 1
SERIAL BUS ADDRESS BYTE
1
9
SCLK (CONTINUED)
D7
D6
D5
D4
D2
D3
D1
D0
STOP BY
MASTER
ACK. BY
ADM1041
FRAME 3
DATA BYTE
04521-0-045
SDATA (CONTINUED)
Figure 25. Writing a Register Address to the Address Pointer Register, then Writing Data to the Selected Register
1
9
1
9
SCLK
A6
A5
A4
A3
A2
A1
A0
R/W
D7
D6
D5
D4
D3
D2
D1
D0
ACK. BY
ADM1041
START BY
MASTER
ACK. BY
ADM1041
FRAME 1
SERIAL BUS ADDRESS BYTE
STOP BY
MASTER
FRAME 2
ADDRESS POINTER REGISTER BYTE
04521-0-046
SDATA
Figure 26. Writing to the Address Pointer Register Only
1
9
1
9
SCLK
A6
A5
A4
A3
A2
A1
A0
R/W
D7
D6
D5
D4
D3
D2
D1
ACK. BY
ADM1041
START BY
MASTER
D0
ACK. BY
ADM1041
FRAME 1
SERIAL BUS ADDRESS BYTE
FRAME 2
DATA BYTE FROM ADM1041
STOP BY
MASTER
04521-0-047
SDATA
Figure 27. Reading Data from a Previously Selected Register
Table 6. Device SMBus Addresses
ADD1
0
0
0
1
1
1
ADD0
GND
VDD
NC
GND
VDD
NC
A2
0
0
1
0
0
1
A1
0
0
0
1
1
0
A0
0
1
0
0
1
1
Target Device
0
1
4
2
3
5
Note: ADD1 is low by default. To access the additional three addresses it is necessary to set Config 4 < 1 > high and then perform a power cycle to allow the new
address to be latched after the EEPROM download. Refer to the section on Extended SMBUS Addressing for more details.
Rev. A | Page 35 of 64
ADM1041
The ADM1041 contains volatile registers (RAM) and nonvolatile EEPROM. RAM occupies the address locations from 00h to
7Fh, while EEPROM occupies the address locations from 8000h
to 813Fh.
The SMBus specification defines several protocols for different
types of read and write operations. The ones used in the
ADM1041 are discussed in the next sections. The following
abbreviations are used in the diagrams:
S—START
P—STOP
The EEPROM page address consists of the EEPROM address
high Byte 80h for FRU or 81h for register default and the three
MSBs of the low byte. The lower five bits of the EEPROM
address of the low byte are ignored during an erase operation.
1
2
3
4
5
6
7
8
9
10
11 12
EEPROM
EEPROM
ADDRESS
ADDRESS
COMMAND A2h
ARBITRARY
SLAVE
W A
A
A
A
A P
S
HIGH BYTE
LOW BYTE
(PAGE ERASE)
DATA
ADDRESS
(80h OR 81h)
(00h TO FFh)
Figure 28. EEPROM Page Erase Operation
Page erasure takes approximately 20 ms. If the EEPROM is
accessed before erasure is complete, the SMBus responds with
No Acknowledge.
Figure 29 shows the peak IDD supply current during an EEPORM
page erase operation. Decoupling capacitors of 10 µF and 100
nF are recommended on VDD.
R—READ
W—WRITE
A—ACKNOWLEDGE
A—NO ACKNOWLEDGE
The ADM1041 uses the following SMBus write protocols.
SMBus Erase EEPROM Page Operations
04521-0-020
EEPROM memory can be written to only if it is effectively
unprogrammed. Before writing to one or more locations that
are already programmed, the page containing those locations
must be erased. EEPROM ERASE is performed by sending a
page erase command byte (A2h) followed by the page location
of what you want to erase. (There is no need to set an erase bit
in an EEPROM control/status register.)
The EEPROM consists of 16 pages of 32 bytes each; the register
default EEPROM consists of 1 page of 32 bytes starting at 8100h.
Table 7. EEPROM Page Layout
Page No.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
EEPROM Location
8000h to 801Fh
8020h to 803Fh
8040h to 8050h
8060h to 8070h
8080h to 8090h
80A0h to 80BFh
80C0h to 80DFh
80E0h to 80FFh
8100h to 811Fh
8120h to 813Fh
8140h to 815Fh
8160h to 817Fh
8180h to 819Fh
81A0h to 81BFh
81C0h to 81DFh
81E0h to 81FFh
Figure 29. EEPROM Page Erase Peak IDD Current
SMBus Write Operations
Description
Available FRU
Available FRU
Available FRU
Available FRU
Available FRU
Available FRU
Available FRU
Available FRU
Configuration Boot Registers
ADI Registers
Available FRU
Available FRU
Available FRU
Available FRU
Available FRU
ADI Registers
Send Byte
In this operation, the master device sends a single command
byte to a slave device, as follows:
1.
The master device asserts a start condition on SDA.
2.
The master sends the 7-bit slave address followed by the
write bit (low).
3.
The addressed slave device asserts ACK on SDA.
4.
The master sends a command code.
5.
The slave asserts ACK on SDA.
6.
The master asserts a stop condition on SDA and the
transaction ends.
Rev. A | Page 36 of 64
04521-0-019
SMBus PROTOCOLS FOR RAM AND EEPROM
ADM1041
In the ADM1041, the send byte protocol is used to write a
register address to RAM for a subsequent single-byte read from
the same address or block read or write starting at that address.
This is illustrated in Figure 30.
3
4
5 6
RAM
SLAVE
S
W A ADDRESS A P
ADDRESS
(00h TO 7Fh)
1
2
3
4
5
6
7 8
EEPROM
EEPROM
ADDRESS
ADDRESS
SLAVE
S
W A
A
A P
HIGH BYTE
LOW BYTE
ADDRESS
(80h OR 81h)
(00h TO FFh)
Figure 30. Setting a RAM Address for Subsequent Read
04521-0-023
2
Set up a 2-byte EEPROM address for a subsequent read or
block read. In this case, the command byte is the high byte
of the EEPROM address (80h). The (only) data byte is the
low byte of the EEPROM address. This is illustrated in
Figure 32.
04521-0-021
1
•
Figure 32. Setting an EEPROM Address
If it is required to read data from the RAM immediately after
setting up the address, the master can assert a repeat start
condition immediately after the final ACK and carry out a
single-byte read, block read, or block write operation without
asserting an intermediate stop condition.
If it is required to read data from the EEPROM immediately after setting up the address, the master can assert a
repeat start condition immediately after the final ACK and
carry out a single-byte read or a block read without
asserting an intermediate stop condition.
Write Byte/Word
1.
The master device asserts a start condition on SDA.
2.
The master sends the 7-bit slave address followed by the
write bit (low).
3.
The addressed slave device asserts ACK on SDA.
4.
The master sends a command code.
5.
The slave asserts ACK on SDA.
6.
The master sends a data byte.
7.
The slave asserts ACK on SDA.
8.
The master sends a data byte (or may assert stop at this
point).
9.
The slave asserts ACK on SDA.
•
Write a single byte of data to EEPROM. In this case, the
command byte is the high byte of the EEPROM address,
80h or 81h. The first data byte is the low byte of the
EEPROM address and the second data byte is the actual
data. Bit 1 of EEPROM Register 3 must be set. This is
illustrated in Figure 33.
1
2
3
4
5
6
7
EEPROM
EEPROM
ADDRESS
ADDRESS
SLAVE
S
W A
A
A
HIGH BYTE
LOW BYTE
ADDRESS
(80h OR 81h)
(00h TO FFh)
8
9 10
DATA
A P
04521-0-024
In this operation, the master device sends a command byte and
one or two data bytes to the slave device, as follows:
Figure 33. Single-Byte Write to EEPROM
If it is required to read data from the ASIC immediately after
setting up the address, the master can assert a repeat start
condition immediately after the final ACK and carry out a
single-byte read, block read, or block write operation without
asserting an intermediate stop condition.
Block Write
In the ADM1041, the write byte/word protocol is used for the
following three purposes. The ADM1041 knows how to respond
by the value of the command byte.
In this operation, the master device writes a block of data to a
slave device. Programming an EEPROM byte takes approximately
300 µs, which limits the SMBus clock for repeated or block write
operations. The start address for a block write must have been
set previously. In the case of the ADM1041, this is done by a
send byte operation to set a RAM address or by a write byte/
word operation to set an EEPROM address.
•
1.
The master device asserts a start condition on SDA.
2.
The master sends the 7-bit slave address followed by the
write bit (low).
10. The master asserts a stop condition on SDA to end the
transaction.
Write a single byte of data to RAM. In this case, the
command byte is the RAM address from 00h to 7Fh and
the (only) data byte is the actual data. This is illustrated in
Figure 31.
S
2
3
SLAVE
W A
ADDRESS
4
5
RAM
ADDRESS A
(00h TO 7Fh)
6
7 8
3.
The addressed slave device asserts ACK on SDA.
DATA
A P
4.
The master sends a command code that tells the slave
device to expect a block write. The ADM1041 command
code for a block read is A0h (10100000).
5.
The slave asserts ACK on SDA.
04521-0-022
1
Figure 31. Single-Byte Write to RAM
Rev. A | Page 37 of 64
ADM1041
6.
The master sends a data byte that tells the slave device how
many data bytes will be sent. The SMBus specification
allows a maximum of 32 data bytes to be sent in a block
write.
7.
The slave asserts ACK on SDA.
8.
The master sends N data bytes.
9.
The slave asserts ACK on SDA after each data byte.
Block Read
In this operation, the master device reads a block of data from a
slave device. The start address for a block read must previously
have been set. In the case of the ADM1041, this is done by a
send byte operation to set a RAM address or by a write byte/word
operation to set an EEPROM address. The block read operation
itself consists of a send byte operation that sends a block read
command to the slave, immediately followed by a repeat start,
and a read operation that reads out multiple data bytes, as follows:
1
2
3
4
5
7
6
8
9
10
BYTE
COMMAND A0h
SLAVE
S
W A
A
A DATA 1 A DATA 2 A DATA N A P
COUNT
(BLOCK WRITE)
ADDRESS
Figure 34. Block Write to EEPROM or RAM
When performing a block write to EEPROM, the page that
contains the location to be written should not be writeprotected (Register 03h) prior to sending the above SMBus
packet. Block writes are limited to within a 32-byte page
boundary and cannot cross into the next page.
SMBus READ OPERATIONS
The ADM1041 uses the following SMBus read protocols.
04521-0-025
10. The master asserts a stop condition on SDA to end the
transaction.
1.
The master device asserts a start condition on SDA.
2.
The master sends the 7-bit slave address followed by the
write bit (low).
3.
The addressed slave device asserts ACK on SDA.
4.
The master sends a command code that tells the slave
device to expect a block read. The ADM1041 command
code for a block read is A1h (10100001).
5.
The slave asserts ACK on SDA.
6.
The master asserts a repeat start condition on SDA.
7.
The master sends the 7-bit slave address followed by the
read bit (high).
8.
The slave asserts ACK on SDA.
9.
The master receives a byte count data byte that tells it how
many data bytes will be received. The SMBus specification
allows a maximum of 32 data bytes to be received in a
block read.
Receive Byte
In this operation, the master device receives a single byte from a
slave device, as follows:
1.
The master device asserts a start condition on SDA.
2.
The master sends the 7-bit slave address followed by the
read bit (high).
3.
The addressed slave device asserts ACK on SDA.
4.
The master receives a data byte.
5.
The master asserts NO ACK on SDA.
6.
The master asserts a stop condition on SDA and the
transaction ends.
10. The master asserts ACK on SDA.
11. The master receives N data bytes.
12. The master asserts ACK on SDA after each data byte.
13. The slave does not acknowledge after the Nth data byte.
14. The master asserts a stop condition on SDA to end the
transaction.
1
2
3
SLAVE
R A
S
ADDRESS
4
5 6
DATA
A P
04521-0-026
In the ADM1041, the receive byte protocol is used to read a
single byte of data from a RAM or EEPROM location whose
address has been set previously by a send byte or write byte/
word operation. This is illustrated in Figure 35.
1
S
2
3
4
5 6
7
8
9
10
11
12
13 14
COMMAND A1h
BYTE
SLAVE
SLAVE
R A
A DATA 1 A DATA N A P
A S
W A
(BLOCK READ)
COUNT
ADDRESS
ADDRESS
Figure 36. Block Read from EEPROM or RAM
Rev. A | Page 38 of 64
04521-0-027
Figure 35. Single-Byte Read from EEPROM or RAM
ADM1041
When using the SMBus interface, a write always consists of the
ADM1041 SMBus interface address byte, followed by the
internal address register byte, and then the data byte. There are
two cases for a read:
If more than one device is asserting an alert, all alerting devices
try to respond with their slave addresses, but an arbitration
process ensures that only the lowest slave address is received by
the master. If the slave device has its alert configured as latching,
it sends a command via the SMBus to clear the latch. The master
should then check if the alert line is still asserted, and, if so,
repeat the ARA call to service the next alert. Note that an alerting
slave does not respond to an ARA call unless it is configured in
SMBus mode (not AC_OKLink/PSONLINK) and up_pson_m is
set. The ADM1041 supports the SMBus (ARA) function.
•
SUPPORT FOR SMBus 1.1
Notes on SMBus Read Operations
The SMBus interface of the ASIC cannot load the SMBUS if no
power is applied to the ASIC. This requirement allows a power
supply to be disconnected from the ac supply while still installed
in a power subsystem.
If the internal address register is known to be at the desired
address, simply read the ASIC with the SMBus interface
address byte, followed by the data byte read from the ASIC.
The internal address pointer increments if a block mode
operation is in progress; data values of 0 are returned if the
register address limit of 7Fh is exceeded, or if unused
registers in the address range 00h to 7Fh are accessed. If
the address register is pointing at EEPROM memory, that
is 8000h, and the address reaches its limit of 80FFh, it does
not roll over to Address 8100h on the next access.
Additional accesses do not increment the address pointer,
all reads return 00h, and all writes complete normally but
do not change any internal register or EEPROM location. If
the address register is pointing at EEPROM memory, that
is 81xxh, and the address reaches its limit of 813Fh, it does
not roll over to Address 8140h on the next access.
Additional accesses do not increment the address pointer,
all reads return 00h, and all writes complete normally but
not change any internal register or EEPROM location. Note
that for byte reads, the internal address does not auto
increment.
LAYOUT CONSIDERATIONS
Noise coupling into the digital lines (greater than 150 mV),
overshoot greater than VCC and undershoot less than GND may
prevent successful SMBus communication with the ADM1041.
SMBus No Acknowledge is the most common symptom,
causing unnecessary traffic on the bus. Although the SMBus
maximum frequency of communication is rather low (400 kHz
max), care still needs to be taken to ensure proper termination
within a system with multiple parts on the bus and long printed
circuit board traces. A 5.1 kΩ resistor can be added in series
with the SDA and SCL lines to help filter noise and ringing.
Minimize noise coupling by keeping digital traces out of
switching power supply areas and ensure that digital lines
containing high speed data communications cross at right
angles to the SDA and SCL lines.
POWER-UP AUTO-CONFIGURATION
If the internal address register value is unknown, write to
the ADM1041 with the SMBus interface address byte,
followed by the internal address register byte. Then restart
the serial communication with a read consisting of the
SMBus interface address byte, followed by the data byte
read from the ADM1041.
SMBus ALERT RESPONSE ADDRESS (ARA)
The ADM1041’s CBD/ALERT pin can be configured to respond
to a variety of fault signals and can be used as an interrupt to a
microprocessor. The pins from several ADM1041s may be wireORed. When the SMBus master (microprocessor) detects an
alert request, it normally needs to read the alert status of each
device to identify the source of the alert.
After power-up or reset, the ADM1041 automatically reads the
content of a 32-byte block of EEPROM memory that starts at
8100h and transfers the contents into the appropriate trim-level
and control registers (00h to 1Bh). In this way, the ADM1041
can be preconfigured with the desired operating characteristics
without the host system having to download the data over the
SMBus. This does not preclude the possibility of modifying the
configuration during normal operation.
Figure 37 shows a block diagram of the EEPROM download at
power-up or power-on reset.
The SMBus ARA provides an easier method to locate the source
of a such an alert. When the master receives an alert, it can send
a general call address (0001100) over the bus. The device asserting the alert responds by returning its own slave address to the
master.
Rev. A | Page 39 of 64
RAM
CONFIGURATION
REGISTERS
EEPROM
POWER UP
Figure 37. EEPROM Download
DIGITAL
TRIM
POTS
DIGITAL
TIMING
CONTROL
04521-0-028
•
SMBus 1.1 optionally adds a CRC8 frame check sequence to
check if transmissions are received correctly. This is particularly
useful for long block read/write EEPROM operations, when the
SMBus is heavily loaded or in a noisy environment. The CRC8
frame can be used to guarantee reliability of the EEPROM.
ADM1041
VDD
EXTENDED SMBus ADDRESSING
A potential problem exists when using more than three
ADM1041s in a single power supply. The first time the device is
powered up, Bit 1 of Configuration Register 1 (ADD1) is 0. This
means that only three device addresses are initially available
defined by ADD0; if there are more than three devices in a
system, two or more of them will have duplicate addresses. See
Figure 38.
N/C 15 ADD0
ICT 8
AC_OKLink
SCL 13
PSONLink
SDA 14
DEVICE 5
To overcome this problem, the ICT pin has additional functionality. Taking ICT below GND temporarily disables the SMBus
function of the device. Thus, if the ICT pin of all devices in
which ADD1 is to remain 0 are taken negative, the ADD1 bits of
all other devices can be set to 1 via the SMBus. Each device then
has a unique address. Internal diodes clamp the negative voltage
to about 0.6 V, and care should be taken to limit the current to
less than approximately 5 mA on each ICT input to prevent the
possibility of damage or latch-up. The suggested current is
3 mA. One example of a suitable circuit is given in Figure 38. The
ADM1041s can then be configured and trimmed. If required,
AC_OKLink and PSONLINK must be configured last. If ICT is
used for its intended purpose as a current transformer input,
care must be taken with the circuit design to allow the extended
SMBus addressing to work.
ICT 8
ADD1 = 1
SCL 13
VDD
15 ADD0
SDA 14
DEVICE 4
ICT 8
SCL 13
15 ADD0
SDA 14
DEVICE 3
4kΩ
ICT 8
SCL 13
N/C 15 ADD0
BACKDOOR ACCESS
SDA 14
2.4mA
After SCL and SDA have been configured as AC_OKLink and
PSONLINK, it may be desired to recover the SMBus access to the
ADM1041. Changes may be necessary to the internal configuration or trim bits. This is achieved by holding the SCL and SDA
pins at 0 V (ground) while cycling VDD. SCL and SDA then
revert to SMBus operation. See Figure 38.
DEVICE 2
EXTENDED
SMBus
ADDRESSING
4kΩ
ICT 8
ADD1 = 0
–12V
SCL 13
VDD
15 ADD0
SDA 14
DEVICE 1
4kΩ
ICT 8
SCL 13
15 ADD0
SDA 14
BACKDOOR
Figure 38. Extended SMBus Addressing and Backdoor Access
Rev. A | Page 40 of 64
04521-0-029
DEVICE 0
ADM1041
REGISTER LISTING
Table 8.
Register Address
00h/2Ah
Name
Status1/Status1 Mirror Latched
01h/2Bh
Status2/Status2 Mirror Latched
02h/2Ch
Status3/Status3 Mirror Latched
03h
04h
05h
06h
07h
08h
09h
0Ah
0Bh
0Ch
0Dh
0Eh
0Fh
10h
11h
12h
13h
14h
15h
16h
17h
18h
19h
1Ah
1Bh
1Ch
1Dh
20h–29h
2Ah
Calibration Bits
Current Sense CC
Current Share Offset
Current Share Slope
EEPROM_lock
Load OV Fine
Local UVP Trim
Local OVP Trim
OTP Trim
ACSNS Trim
Config1
Config2
Config3
Config4
Config5
Config6
Config7
Current Sense Divider Error Trim
Current Sense Amplifer Offset
Trim
Current Sense Config 1
Current Sense Config 2
UV Clamp Trim
Diff Sense Trim
Sel CBD/SMBAlert1
Sel CBD/SMBAlert2
Manufacturer’s ID
Revision Register
Reserved for Manufacturer
Status1 Mirror Latched
2Bh
Status2 Mirror Latched
2Ch
Status3 Mirror Latched
2Dh–2Eh
8000h–81FFh
Reserved for Manufacturer
EEPROM
Power-On Value
XXh—Depends on status of
ADM1041 at power-up.
XXh—Depends on status of
ADM1041 at power-up.
XXh—Depends on status of
ADM1041 at power-up.
From EEPROM Register 8103h
From EEPROM Register 8104h
From EEPROM Register 8105h
From EEPROM Register 8106h
From EEPROM Register 8107h
From EEPROM Register 8108h
From EEPROM Register 8109h
From EEPROM Register 810Ah
From EEPROM Register 810Bh
From EEPROM Register 810Ch
From EEPROM Register 810Dh
From EEPROM Register 810Eh
From EEPROM Register 810Fh
From EEPROM Register 8110h
From EEPROM Register 8111h
From EEPROM Register 8112h
From EEPROM Register 8113h
From EEPROM Register 8114h
From EEPROM Register 8115h
From EEPROM Register 8116h
From EEPROM Register 8117h
From EEPROM Register 8118h
From EEPROM Register 8119h
From EEPROM Register 811Ah
From EEPROM Register 811Bh
41h—Hardwired by manufacturer
Xh—Hardwired by Manufacturer
XXh—Depends on status of
ADM1041 at power-up.
XXh—Depends on status of
ADM1041 at power-up.
XXh—Depends on status of
ADM1041 at power-up.
Rev. A | Page 41 of 64
Factory EEPROM Value
00h
00h
00h
FEh
20h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
XXh – Factory Cal Values
XXh – Factory Cal Values
XXh – Factory Cal Values
XXh – Factory Cal Values
00h
00h
00h
00h
ADM1041
DETAILED REGISTER DESCRIPTIONS
Table 9. Register 00h, Status1. Power-On Default XXh (Refer to the logic schematic—Figure 24.)
Bit No.
7
6
5
4
3
2
1
0
Name
ovfault
uvfault
ocpto
mfg1
mfg2
mfg3
mfg4
mfg5
R/W
R
R
R
R
R
R
R
R
Description
Overvoltage fault has occurred.
Undervoltage fault has occurred.
Overcurrent has occured and timed out (ocpf is in Status3).
MON1 flag.
MON2 flag.
MON3 flag.
MON4 flag.
MON5 flag.
Table 10. Register 01h, Status2. Power-On Default XXh (Refer to the logic schematic—Figure 24.)
Bit No.
7
6
5
4
3
2
1
0
Name
Share_OK
OrFET_OK
REVERSE_OK
VDD_OK
GND_OK
intrefok
extrefok
vddov
R/W
R
R
R
R
R
R
R
R
Description
Current share is within limits.
ORing MOSFET is on.
reverseok—No reverse voltage has occured across the ORing MOSFET.
VDD is within limits .
Connection of GND pin is good.
Internal voltage reference is within limits.
External voltage reference is within limits.
VDD is above its OV threshold.
Table 11. Register 02h, Status3. Power-On Default XXh (Refer to the logic schematic—Figure 24.)
Bit No.
7
6
5
4
3
2
1
0
Name
m_acsns_r
m_pson_r
m_penok_r
m_psonok_r
m_DC_OK_r
ocpf
PULSE_OK
fault
R/W
R
R
R
R
R
R
R
R
Description
Reflects the status on ACSENSE1/ACSENSE2.
Reflects the status of PSON.
Reflects the status of PEN.
Status of PSONLINK.
Status of DC_OK.
An overcurrent has occured, direct from comparator
Pulses are present at the PULSE pin.
Fault latch.
Table 12. Register 03h, Calibration Bits. Power-On Default from EEPROM Register 8103h during Power-Up.
Bit No.
7–6
Name
rev_volt_off
R/W
R/W
5–4
rev_volt_on
R/W
3
2
gatepen
gateramp
R/W
R/W
Description
Reverse Voltage Detector Turn Off Threshold:
b7
b6
Function
0
0
100 mV
0
1
150 mV
1
0
200 mV
1
1
250 mV
Reverse Voltage Detector Turn On Threshold:
b5
b4
Function
0
0
20 mV
0
1
30 mV
1
0
40 mV
1
1
50 mV
Gatepen Option. When set, PEN is gated by acsok.
Gateramp Option. When set, soft-start is gated by acsok.
Rev. A | Page 42 of 64
ADM1041
Bit No.
1–0
Name
loadov_recover
R/W
R/W
Description
b1
0
0
1
1
b0
0
1
0
1
Function
Add 100 µs delay
Add 200 µs delay
Add 300 µs delay
Add 400 µs delay
Table 13. Register 04h, Current Sense CC. Power-On Default from EEPROM Register 8104h during Power-Up.
Bit No.
7–3
2
1–0
Name
curr_limit
Share_OK_Window
Share_OK_thresh
R/W
R/W
R/W
Description
This register contains current sense trim level setting at which current limiting starts
Share_OK Window Comparator Thresholds
b1
b0
Function
0
0
±100 mV
0
1
±200 mV
1
0
±300 mV
1
1
±400 mV
Table 14. Register 05h, Current Share Offset. Power-On Default from EEPROM Register 8105h during Power-Up.
Bit No.
7–0
Name
ISHARE_offset
R/W
R/W
Description
This register contains current share offset trim level. Writing 00h corresponds to the min
offset. FFh corresponds to maximum offset. See the Current Limit Error Amplifier section in
the Specifications for more information.
Table 15. Register 06h , Current Share Slope. Power-On Default from EEPROM Register 8106h during Power-Up.
Bit No.
7–1
0
Name
ISHARE_slope
Reserved
R/W
R/W
X
Description
This register contains current share slope trim level.
Don’t Care
Table 16. Register 07h, EEPROM_lock. Power-On Default from EEPROM Register 8107h during Power-Up.
Bit No.
7
6
5
4
3
2
1
0
Name
Reserved
lock6
lock5
lock4
lock3
lock2
lock1
lock0
R/W
X
R/W
R/W
R/W
R/W
R/W
R/W
R/W
Description
Don’t Care
Locks 8140h–817Fh
Locks 8120h–813Fh
Locks 8100h–811Fh
Locks 80C0h–80FFh
Locks 8080h–80BFh
Locks 8040h–807Fh
Locks 8000h–803Fh
Available FRU.
ADI cal registers, Locked by manufacturer.
ADM1041 Config Boot registers.
Available FRU.
Available FRU.
Available FRU.
Available FRU.
Table 17. Register 08h, Load OV Trim. Power-On Default from EEPROM Register 8108h during Power-Up.
Bit No.
7–0
Name
load_ov
R/W
R/W
Description
Load OV trim
Table 18. Register 09h, Local UVP Trim. Power-On Default from EEPROM Register 8109h during Power-Up.
Bit No.
7–0
Name
local_uvp
R/W
R/W
Description
Local UVP trim
Rev. A | Page 43 of 64
ADM1041
Table 19. Register 0Ah, Local OVP Trim. Power-On Default from EEPROM Register 810Ah during Power-Up.
Bit No.
7–0
Name
local_ovp
R/W
R/W
Description
Local OVP Trim
Table 20. Register 0Bh, OTP Trim. Power-On Default from EEPROM Register 810Bh during Power-Up.
Bit No.
7–4
3–1
0
Name
otp_trim
reserved
softotp
R/W
R/W
X
R/W
Description
OTP Threshold
Don’t Care
Configure Soft OTP Option
0 = mon5 +ve ov = ov
1 = mon5 +ve ov = softotp
Table 21. Register 0Ch, ACSENSE Trim. Power-On Default from EEPROM Register 810Ch during Power-Up.
Bit No.
7–3
2–0
Name
acsns_thresh
acsns_hyst
R/W
R/W
R/W
Description
ACSENSE Threshold Trim Settings
ACSENSE Hysteresis Trim Settings
Table 22. Register 0Dh, Config1. Power-On Default from EEPROM Register 810Dh during Power-Up.
Bit No.
7
Name
up_pson_m
R/W
R/W
6
5
4
reserved
reserved
uvbm
X
3–1
mn1s2, mn1s1,
mn1s0
X
R/W
R/W
Description
0 = internal PSON.
1 = support via SMBus. Selects PSON from config6 < 1 > = m_pson_w.
Don’t Care.
Don’t Care.
Undervoltage Blanking Mode.
uvbm = 1: blanking-hold period starts from recovery of AC_OK.
uvbm = 0: blanking-hold period starts following SCL = 0 while i2cm = 1.
b3
b2
b1
option
mfg1
ov
0
0
0
0
i2cmb
R/W
0
0
1
0
1
0
iopin = ACSNS1
iopin = ACSNS1
+ve ov
iopin < 1.15 V
iopin > 1.25 V
0
1
1
+ve uv
iopin < 1.25 V
iopin > 1.35 V
1
0
0
–ve ov
iopin < 1.25 V
iopin > 1.35 V
1
0
1
–ve uv
iopin < 1.15 V
iopin > 1.25 V
1
1
0
flag
iopin < 1.15 V
iopin > 1.25 V
1
1
1
flag
iopin < 1.15 V
iopin > 1.25 V
0 = pins are configured as SDA/SCL (default).
1 = SCL pin is configured as AC_OKLink output.
SDA pin is configured as PSONLINK output.
Rev. A | Page 44 of 64
uv
(true = high)
(true = high)
0
1
0
1
0
1
0
1
0
1
1
0
0
1
0
0
1
0
0
0
0
0
0
0
0
0
1
0
0
0
0
1
0
0
0
0
ADM1041
Table 23. Register 0Eh, Config2. Power-On Default from EEPROM Register 810Eh during Power-Up.
Bit No.
7–5
4–2
1–0
Name
mn2s2, mn2s1,
mn2s0
mn3s2, mn3s1,
mn3s0
pokts1, pokts0
R/W
Description
W
b7
0
0
0
b6
0
0
1
b5
0
1
0
0
1
1
1
0
0
1
0
1
1
1
0
1
1
1
b4
b3
0
0
0
R/W
R/W
Ov
uv
option
iopin = ACSENSE2
iopin = ACSENSE2
+ve ov
iopin < 1.15 V
iopin > 1.25 V
+ve uv
iopin < 1.25 V
iopin > 1.35 V
−ve ov
iopin < 1.25 V
iopin > 1.35 V
−ve uv
iopin < 1.15 V
iopin > 1.25 V
flag
iopin < 1.15 V
iopin > 1.25 V
flag
iopin > 1.25 V
iopin > 1.25 V
mfg2
0
1
0
1
0
1
0
1
0
1
1
0
0
1
0
0
1
0
0
0
0
0
0
0
0
0
1
0
0
0
0
1
0
0
0
0
b2
option
mfg3
ov
uv
0
0
1
0
1
0
0
1
1
1
0
0
1
0
1
1
1
0
1
1
1
iopin = PSON
iopin = PSON
+ve ov
iopin < 1.15 V
iopin > 1.25 V
+ve uv
iopin < 1.25 V
iopin > 1.35 V
−ve ov
iopin < 1.25 V
iopin > 1.35 V
−ve uv
iopin < 1.15 V
iopin > 1.25 V
flag
iopin < 1.15 V
iopin > 1.25 V
flag
iopin < 1.15 V
iopin > 1.25 V
DC_OKon_delay
b1
0
0
1
1
b0
0
1
0
1
option
400 ms
200 ms
800 ms
1600 ms
Rev. A | Page 45 of 64
(true = high)
(true = high)
(true = low)
(true = high)
0
1
0
1
0
1
0
1
0
1
1
0
0
1
0
0
1
0
0
0
0
0
0
0
0
0
1
0
0
0
0
1
0
0
0
0
ADM1041
Table 24. Register 0Fh, Config3. Power-On Default from EEPROM Register 810Fh during Power-Up.
Bit No.
7–5
4–2
1–0
Name
mn4s2, mn4s1,
mn4s0
mn5s2, mn5s1,
mn5s0
psonts1, psonts0
R/W
R/W
R/W
R/W
Description
b7
b6
b5
option
0
0
0
iopin = DC_OK
0
0
0
1
1
0
0
1
1
1
0
0
1
0
1
1
1
0
1
1
1
b4
b3
b2
iopin = DC_OK
+ve ov
iopin < 1.15 V
iopin > 1.25 V
+ve uv
iopin < 1.25 V
iopin > 1.35 V
−ve ov
iopin < 1.25 V
iopin > 1.35 V
−ve uv
iopin < 1.15 V
iopin > 1.25 V
flag
iopin < 1.15 V
iopin > 1.25 V
flag
iopin < 1.15 V
iopin > 1.25 V
option
0
0
0
0
0
1
0
1
0
mfg4
iopin = AC_OK
iopin = AC_OK
+ve ov
iopin < vdac
iopin > vdac
0
1
1
+ve uv
iopin < vdac
iopin > vdac
1
0
0
−ve ov
iopin < vdac
iopin > vdac
1
0
1
−ve uv
iopin < vdac
iopin > vdac
1
1
0
flag
iopin < vdac
iopin > vdac
1
1
1
vref out (e.g., 2.5 V VREF
PSON debounce time:
b1
b0
option
0
0
80 ms
1
0
0 ms (no debounce)
1
0
40 ms
1
1
160 ms
ov
Refer to the
Configuration table
(Table 45)
0
1
0
1
0
1
0
1
0
1
0
0
mfg5
0
1
0
0
1
0
0
0
0
0
0
0
ov
0
0
1
0
0
0
0
1
0
0
0
0
uv
0
1
0
1
0
0
1
0
0
1
0
0
1
0
0
1
0
0
0
1
0
1
0
0
0
0
0
1
0
0
Table 25. Register 10h, Config4. Power-On Default from EEPROM Register 8110h during Power-Up.
Bit No.
7–6
Name
DC_OKoff_delay
R/W
R/W
5–4
ISHARE_capture
R/W
Description
DC_OKoff delay (Power-Off Warn Delay)
b7
b6
option
0
0
2 ms
0
1
0 ms
1
0
1 ms
1
1
4 ms
b5
b4
option
0
0
1%
Rev. A | Page 46 of 64
uv
Refer to the
Configuration table
(Table 45)
ADM1041
Bit No.
Name
R/W
3–2
ssrs1, ssrs0
R/W
1
0
add1
trim_lock
R/W
R/W
Description
0
1
2%
1
0
3%
1
1
4%
Soft-Start Step
b3
b2
Rise Time
0
0
300 µs
0
1
10 ms
1
0
20 ms
1
1
40 ms
EEPROM programmable second address bit.
When this bit is set, the trim registers including this register are not writable via SMBus. To
make registers writable again, the trim-lock bit in the EEPROM must first be erased and the
value downloaded using either power-up or test download.
Table 26. Register 11h, Config5. Power-On Default from EEPROM Register 8111h 8110h during Power-Up.
Bit No.
7
6
5
4–3
2
Name
curr_lim_dis
polpen0
polcbd0
Reserved
ocpts2
R/W
R/W
R/W
R/W
X
R/W
1
0
gndok_dis
cbdlm
R/W
R/W
Description
Mask effect of OCP to general logic (status flag still gets asserted) when curr_lim_dis = 1.
Sets polarity of PEN output. Refer to the Configuration table (Table 45).
Sets polarity of CBD output. Refer to the Configuration table (Table 45).
Don’t Care.
Set this bit to 1 when 0 OCP ridethrough is required. A small delay still exists. Refer to Reg 12h
and the Configuration table (Table 45).
Disable gndok input to power management debounce logic.
Select CBD latch mode. 0 = nonlatching; 1 = latching.
Table 27. Register 12h, Config6. Power-On Default from EEPROM Register 8112h 8110h during Power-Up.
Bit No.
7
Name
rsm
R/W
R/W
6
up_AC_OK_m
R/W
5
4–3
m_acsns_w
ocpts1, ocpts0
(W)
R/W
2
acss
(W)
1
0
m_pson_w
ISHARE_clamp
(W)
R/W
Description
Restart Mode. When rsm = 1, the circuit attempts to restart the supply after an undervoltage or
overcurrent at about 1 second intervals.
Latch Mode. When rsm = 0, UV and OC faults latch the output off. Cycling PSON or removing the
supply to the IC is then required to reset the latch and permit a restart.
Configure microprocessor to control/gate signal from acinok to acsok.
0 = standalone.
1 = microprocessor support mode.
Microcessor control of acsok (ACSENSE).
OCP Ridethrough (Reg 11h[2] = 0)
OCP Ridethrough (Reg11h[2] = 1)
b4
b3
Period
b4
b3
Period
0
0
1 second
0
0
128 µs
0
1
2 seconds
0
1
256 µs
1
0
3 seconds
1
0
384 µs
1
1
4 seconds
1
1
512 µs
AC Sense Mode. 0 means AC_OK is derived from ACSENSE1, whereas 1 means AC_OK is derived from
ACSENSE2.
Microprocessor control of pson.
0 = 75%. Set current share clamp release threshold.
1 = 88%.
Table 28. Register 13h, Config7. Power-On Default from EEPROM Register 8113h during Power-Up.
Bit No.
Name
R/W
Description
Rev. A | Page 47 of 64
ADM1041
Bit No.
7
6
5
4
3
2
Name
polpen1
polcbd1
polDC_OK1
polAC_OK1
polfg
m_shr_clmp
R/W
R/W
R/W
R/W
R/W
R/W
(W)
1
m_cbd_w
R/W
0
m_cbd_clr
R/W
Description
Sets polarity of PEN output. Refer to the Configuration table (Table 45).
Sets polarity of CBD output. Refer to the Configuration table (Table 45).
Sets polarity of DC_OK output. Refer to the Configuration table (Table 45).
Sets polarity of AC_OK output. Refer to the Configuration table (Table 45).
Sets polarity of OrFET gate control: 0 = inverted (low = on).
Allow the microprocessor to directly control the share clamp 0 = normal share clamp
operation, i.e., not clamped 1 = assert share clamp, i.e., clamped.
Allow the microprocessor to write directly to CBD as a possible way of adding an additional
port. This might be a blinking led or a fail signal to the system.
Microprocessor clear of CBD latch (if configured as latching) folowing an SMBAlert.
Table 29. Register 14h, Current Sense Divider Error Trim 1. Power-On Default from EEPROM Register 8114h during Power-Up.
Bit No.
7–0
Name
os_div
R/W
R/W
Description
Trim-out offset due to external resistor divider tolerances (for common-mode correction).
Table 30. Register 15h, Current Sense Amp Offset Trim 2. Power-On Default from EEPROM Register 8115h during Power-Up.
Bit No.
7–0
Name
os_dc
R/W
R/W
Description
Trim-out current sense amplifier offset (dc offset correction).
Table 31. Register 16h, Current Sense Options 1. Power-On Default from EEPROM Register 8116h during Power-Up.
Bit No.
7–6
5–3
Name
isense3
os_div_range
R/W
R/W
R/W
2–0
isense_range
R/W
Description
Unused.
External Divider Tolerance Trim Range (Common-Mode Trim Range).
b5
b4
b3
Range
External Resistor Tolerance
0
0
0
−5 mV
−0.25%
0
0
1
−10 mV
−0.50%
0
1
0
−20 mV
−1.00%
1
0
0
+5 mV
+0.25%
1
0
1
+10 mV
+0.50%
1
1
0
+20 mV
+1.00%
Gain Selector
b2
b1
b0
Gain
Range
0
0
0
65x
34.0 mV to 44.5 mV
0
0
1
85x
26.0 mV to 34.0 mV
0
1
0
110x
20.0 mV to 26.0 mV
1
0
0
135x
16.0 mV to 20.0 mV
1
0
1
175x
12.0 mV to 16.0 mV
1
1
0
230x
9.5 mV to 12.0 mV
Rev. A | Page 48 of 64
ADM1041
Table 32. Register 17h, Current Sense Option 2. Power-On Default from EEPROM Register 8117h during Power-Up.
Bit No.
7
Name
csense_mode
R/W
R/W
6
chopper
R/W
5
ct_range
R/W
4
select_gnd_offset
R/W
3
2–0
Reserved
os_dc_range
X
R/W
Description
0 = DIFFSENSE (current sense with external resistor).
1 = CTSENSE (current transformer).
When chopper = 1, current sense amplifier is configured as a chopper.
Otherwise, current sense amplifier is continuous time.
Gain
Range
0 = 4.5
0.45 V–0.68 V
1 = 2.57
0.79 V–1.20 V
0: ground offset = 100 mV; ISHARE error amp, offset = 50 mV.
1: ground offset = 0; ISHARE error amp offset = 0.
Don’t Care.
Internal Sense Amp Offset Trim Range for Differential Current Sense
b2
b1
b0
Range
0
0
0
−8 mV
0
0
1
−15 mV
0
1
0
−30 mV
1
0
0
+8 mV
1
0
1
+15 mV
1
1
0
+30 mV
Gain
−1
−2
−4
+1
+2
+4
Table 33. Register 18h, UV Clamp Trim. Power-On Default from EEPROM Register 8118h during Power-Up.
Bit No.
Name
R/W
Description
7–0
uv_clamp
R/W
This register contains the false UV clamp settings.
Table 34. Register 19h, Load Voltage Trim. Power-On Default from EEPROM Register 8119h during Power-Up.
Bit No.
7–0
Name
load_v
R/W
R/W
Description
This register contains the set load voltage trim settings.
Table 35. Register 1Ah, Sel CBD/SMBAlert1. Power-On Default From EEPROM Register 811Ah during Power-Up.
Bit No.
7
6
5
4
3
2
1
0
Name
selcbd1 <7>
selcbd1 <6>
selcbd1 <5>
selcbd1 <4>
selcbd1 <3>
selcbd1 <2>
selcbd1 <1>
Selcbd1 <0>
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
Description
ovfault
uvfault
ocpto (ridethrough timed out, ocpf flag)
acsnsb (inverted)
ocpf
otp (MON5 OV)
orfetokb (inverted)
Share_OKb (inverted)
Rev. A | Page 49 of 64
ADM1041
Table 36. Register 1Bh, Sel CBD/SMBAlert2. Power-On Default from EEPROM Register 811Bh during Power-Up.
Bit No.
7
6
5
4
3
2
1
0
Name
selcbd2 <7>
selcbd2 <6>
selcbd2 <5>
selcbd2 <4>
selcbd2 <3>
selcbd2 <2>
selcbd2 <1>
selcbd2 <0>
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
Description
VDDOK b (inverted)
mfg1
mfg2
mfg3
mfg4
m_cbd_w Microprocessor Control of CBD
mfg5
Not used.
Table 37. Register 1Ch, Manufacturer’s ID. Power-On Default 41h.
Bit No.
7–0
Name
Manufacturer’s ID
Code
R/W
R
Description
This register contains the manufacturer’s ID code for the device. It is used by the manufacturer
for test purposes and should not be read from or written to in normal operation.
Table 38. Register 1Dh, Revision Register. Power-On Default 01h.
Bit No.
7–4
3–0
Name
Major Revision Code
Minor Revision Code
R/W
R
R
Description
These 4 bits denote the generation of the device.
These 4 bits contain the manufacturer’s code for minor revisions to the device. Rev 0 = 0h, Rev
1 = 1h, and so on.
This register is used by the manufacturer for test purposes. It should not be read from or
written to in normal operation.
Table 39. Register 2Ah, Status1 Mirror. Power-On Default 00h.
These flags are cleared by a register read, provided the fault no longer persists.
Bit No.
7
6
5
4
3
2
1
0
Name
ovfault_L
uvfault_L
ocpto_L
mfg1_L
mfg2_L
mfg3_L
mfg4_L
mfg5_L
R/W
R
R
R
R
R
R
R
R
Description
Overvoltage fault has occurred.
Undervoltage fault has occurred.
Overcurrent has occured and timed out (ocpf is in Status3).
MON1 flag.
MON2 flag.
MON3 flag.
MON4 flag.
MON5 flag.
Note that latched bits are clocked on a low-to-high transmission only. Also note that these
register bits are cleared when read via the SMBus, except if the fault is still present. It is
recommended to read the register again after the faults disappear to ensure reset.
Rev. A | Page 50 of 64
ADM1041
Table 40. Register 2Bh, Status2 Mirror. Power-On Default 00h.
These flags are cleared by a register read, provided the fault no longer persists.
Bit No.
7
6
5
4
3
2
1
0
Name
Share_OKb_L
orfetokb_L
reverseokb_L
VDDOK b_L
gndokb_L
intrefokb_L
extrefokb_L
vddov_L
R/W
R
R
R
R
R
R
R
R
Description
share fault
ORFET fault
reverse fault
vdd fault
gnd fault
intref fault
extref fault
vddov
Note that latched bits are clocked on a low-to-high transmission only. Also note that these
register bits are cleared when read via the SMBus, except if the fault is still present. It is
recommended to read the register again after faults disappear to ensure reset.
Table 41. Register 2Ch, Status3 Mirror. Power-On Default 00h
These flags are cleared by a register read, provided the fault no longer persists.
Bit No.
7
6
5
4
3
2
1
0
Name
m_acsns_rb_L
m_pson_rb_L
m_penok_rb_L
m_psonok_rb_L
m_DC_OK_rb_L
ocpf
PULSE_OKb_L
fault
R/W
R
R
R
R
R
R
R
R
Description
AC_OK fault
PSON fault
PEN fault
PSONLINK fault
DC_OK fault
ocpf fault
pulse fault
fault latch
Note that latched bits are clocked on a low-to-high transmission only. Also note that these
register bits are cleared when read via the SMBus, except if the fault is still present. It is
recommended to read the register again after the faults disappear to ensure reset.
MANUFACTURING DATA
Table 42.
Register 81F0h
Register 81F1h
Register 81F2h
Register 81F3h
Register 81F4h
Register 81F5h
Register 81F6h
Register 81F7h
Register 81F8h
Register 81F9h
Register 81FAh
Register 81FBh
Register 81FCh
Register 81FDh
Register 81FEh
Register 81FFh
PROBE1_BIN
PROBE2_BIN
FT_BIN
PROBE1_CHKSUM
PROBE2_CHKSUM
FT_CHKSUM
QUAL_PART_ID
Probe 1 cell current data (integer)
Probe 1 cell current data (two decimal places)
Probe 2 cell current data (integer)
Probe 2 cell current data (two decimal places)
Final test cell current data (integer)
Final test cell current data (two decimal places)
Probe X coordinate
Probe Y coordinate
Wafer number
Rev. A | Page 51 of 64
ADM1041
MICROPROCESSOR SUPPORT
Table 43.
Mnemonic
m_pson_r
m_pson_w
m_acsns_r
m_acsns_w
m_shr_clmp
m_cbd_w
m_cbd_clr
mfg5
mfg4
mfg3
mfg2
mfg1
ocpto
uvfault
ovfault
vddov
extrefok
intrefok
gndok
VDDOK
reverseok
orfetok
Share_OK
fault
PULSE_OK
Description
Allows the microprocessor to read the state of PSON. This allows only one
ADM1041 to be configured as the PSON interface to the host system.
Allow the microprocessor to write to control the PSON function of each ASIC.
When in microprocessor support mode, the principle configuration for controlling
power-on/power-off will be as follows: One ADM1041 would be configured to be
the interface to the host system through the standard PSON pin. This pin would be
configured not to write through to the PSON debounce block. The microprocessor
would poll the status of this ADM1041 by reading m_pson_r. Debouncing would
be done by the microprocessor. If m_pson_r changed state, the microprocessor
would write the new state to m_pson_w in all ADM1041s on the SMBus. If a fault
were to occur on any output, the SMBAlert interrupt would request microprocessor
attention. If this means turning all ADM1041s off, this would be done by writing a
zero to the m_pson_w bit.
Allows the microprocessor to read the state of ACSENSE1/ACSENSE2. This allows one
ADM1041 to be configured as the interface to the host power supply.
Allow the microprocessor to write to control the ACSOK function of each ADM1041.
When in microprocessor support mode the principle configuration for controlling
AC_OK, undervoltage blanking, PEN gating, and RAMP/SS gating will be as follows:
One ADM1041 will be configured to be the interface with the host power supply
AC monitoring circuitry. This ADM1041 might be configured so that the acsns
signal would be written through or would not be written through. Regardless, the
microprocessor would monitor m_acsns_r and write to m_acsns_w as appropriate.
Since it is possible to sense but not to write through, it is possible to configure a
second ADM1041 to monitor a second ac or bulk voltage.
Allow the µP to write directly to m_shr_clmp to control when the ISHARE clamp is
released. During a hot-swap insertion, there may be a need to delay the release of
the ISHARE clamp. This allows the designer an option over the default release at
75% or 88% of the reference ramp (soft-start).
Allow the microprocessor to write directly to CBD as a possible way of adding an
additional output port. This might be for blinking LEDs or as a FAIL signal to the
system.
Allows the microprocessor to clear the CBD latch following an SMBalert. If CBD is
configured to be latching, there may be circumstances that lead to CBD/SMBAlert
being set by, for example, one of the MON flags but does not lead to PSON being
cycled and CBD being reset. In this case, the microprocessor needs to write directly
to CBD to reset the latch.
This flag indicates the status of the MON5 pin.
This flag indicates the status of the MON4 pin.
This flag indicates the status of the MON3 pin.
This flag indicates the status of the MON2 pin.
This flag indicates the status of the MON1 pin.
If this flag is high, an overcurrent has occurred and timed out.
If this flag is high, an undervoltage has been sensed
If this flag is high, an overvoltage has been sensed.
If this flag is high, a VDD overvoltage has been sensed.
If this flag is low, the externally available reference on Pin 18 is overloaded.
If this flag is low, the internal reference has no integrity.
If this flag is low, the ASIC ground, Pin 7, is open either pin to PCB or bond wires.
If this flag is low, VDD is below its UVL or the power mangement block has a
problem, a reference voltage, ground fault, or VDD overvoltage fault.
If this flag is low, the OrFET has an excessive reverse voltage.
If this flag is low, either PULSE_OK, penok, loadvok, or reverseok is false.
If this flag is low, the current share accuracy is out of limits.
Fault latch. If this flag is high, either an ovfault, uvfault, or ocp has occured.
Pulses are present at ACSENSE 1.
Rev. A | Page 52 of 64
Register
02h
Bit
6
Read/Write
Read-only
12h
1
Write-only
02h
7
Read-only
12h
5
Write-only
13h
2
Write-only
1Bh
1
Write-only
13h
0
Write-only
00h
00h
00h
00h
00h
00h
00h
00h
01h
01h
01h
01h
01h
0
1
2
3
4
5
6
7
0
1
2
3
4
Read-only
Read-only
Read-only
Read-only
Read-only
Read-only
Read-only
Read-only
read only
Read-only
Read-only
Read-only
Read-only
01h
01h
01h
02h
02h
5
6
7
0
1
Read-only
Read-only
Read-only
Read-only
Read-only
ADM1041
Mnemonic
ocpf
m_DC_OK_r
m_psonok_r
m_penok_r
m_pson_r
m_acsns_r
mfg5_L
mfg4_L
mfg3_L
mfg2_L
mfgl_L
ocpto_L
uvfault_L
ovfault_L
vddov_L
extrefokb_L
intrefokb_L
gndokb_L
VDDOK b_L
reverseokb_L
orfetokb_L
Share_OKb_L
fault_L
PULSE_OKb_L
ocpf_L
m_DC_OK_rb_L
m_psonok_rb_L
m_penok_rb_L
m_pson_rb_L
m_acsns_rb_L
Description
If this flag is high, an overcurrent has been sensed and the ocp timer has started.
This flag indicates the status of the DC_OK pin.
This flag indicates the status of the PSONLINK pin.
This flag indicates the status of the PEN pin.
This flag indicates the status of the PSON pin.
This flag indicates the status of the ACSENSE1/ACSENSE2 pin.
Latched status of MON5 flag.
Latched status of MON4 flag.
Latched status of MON3 flag.
Latched status of MON2 flag.
Latched status of MON1 flag.
Latched ocpto.
Latched uvfault.
Latched ovfault.
Latched vddov fault.
Latched extref fault.
Latched intref fault.
Latched gnd fault.
Latched VDD fault.
Latched reverse voltage fault.
Latched orfet fault.
Latched share fault.
Latched fault.
Latched pulse fault.
Latched ocpf fault.
Latched DC_OK fault.
Latched PSONLINKfault.
Latched PEN fault.
Latched PSON fault.
Latched ACSENSE fault.
Register
02h
02h
02h
02h
02h
2Ah
2Ah
2Ah
2Ah
2Ah
2Ah
2Ah
2Ah
2Bh
2Bh
2Bh
2Bh
2Bh
2Bh
2Bh
2Bh
2Ch
2Ch
2Ch
2Ch
2Ch
2Ch
2Ch
2Ch
Bit
2
3
4
5
6
7
0
1
2
3
4
5
6
7
0
1
2
3
4
5
6
7
0
1
2
3
4
5
6
7
Read/Write
Read-only
Read-only
Read-only
Read-only
Read-only
Read-only
Read-only
Read-only
Read-only
Read-only
Read-only
Read-only
Read-only
Read-only
Read-only
Read-only
Read-only
Read-only
Read-only
Read-only
Read-only
Read-only
Read-only
Read-only
Read-only
Read-only
Read-only
Read-only
Read-only
Read-only
Notes to Microprocessor (µP) support.
1.
2.
Possible ways to turn the ADM1041 on or off in response to a system request or a fault include:
•
Daisy chaining other ADM1041 PSON pins to the PEN pin, which is controlled by PSON on one ADM1041.
•
The microprocessor looks after the PSON—system interface and any shutdowns due to faults.
•
Connect all AC_OKLink pins together and connect all PSONLINK pins together. These pins must be configured appropriately.
Flags appended with _L are latched (Registers 2Ah/2Bh/2Ch). The latch is reset when the flag is read, except when the fault is still
present. It is advisable to continue reading the flag(s) until the fault(s) have cleared.
Rev. A | Page 53 of 64
ADM1041
TRIM TABLE
This table shows all of the trims that can be set in the ADM1041.
Table 44.
Description
Name
Range
Steps
Step Size
Reg
Bit No.
Set Load Voltage. Trim output from
differential amplifier to set voltage at load.
load_v
1.7 V–2.3 V
(at input pins)
255
1.74 mV–3.18 mV
19h
7–0
Set Load OV. Trim calibrated output from
remote sense amplifier to set load OV
threshold.
load_ov
105%–120%
Offset input
255
1.6 mV
08h
7–0
Set False UV Clamp Threshold. Fine trim
output to set voltage before OR-FET in case
of load OV (at input pins).
uv_clamp
1.3 V–2.1 V
255
1.94 mV–5.07 mV
18h
7–0
Set Local UVP Threshold. Fine trim output
from local sense buffer to set UVP
threshold (at input pins).
local_uvp
1.3 V–2.1V
255
1.94 mV–5.07 mV
09h
7–0
Set Local OVP Threshold. Fine trim output
from sense buffer to set OVP threshold (at
input pins).
local_ovp
1.9 V–2.85 V
255
2.48 mV–5.59 mV
0Ah
7–0
External Divider Offset Trim Range.
os_
div_range
±5 mV
±10 mV
±20 mV
20 µV
39 µV
78 µV
16h
5-3
External Divider Offset Trim. Trim out offset
due to resistor divider tolerances.
os_div
14h
7–0
DC Offset Trim Range.
os_dc_range
17h
3–0
Current Sense DC Offset Trim. Trim out
amplifier dc offset.
os_dc
15h
7–0
Calibrate Current Sense Range. Differential
sense input, six ranges configurable.
ISENSE_range
9.5 to 12.0 mV
12.0 to 16.0 mV
16.0 to 20.0 mV
20.0 to 26.0 mV
26.0 to 34.0 mV
34.0 to 44.5 mV
16h
2–0
Current Transformer Gain Range.
ct_range
0.45 to 0.68 V
0.79 to 1.2 V
17h
5
Calibrate Current Sense. ISHARE = 2.0 V.
ISHARE_slope
Current Share Offset. Trim offset to be
added to ISHARE output.
ISHARE_offset
Current Limit Trim. Current sense level
where current limiting will start.
255
30 µV
60 µV
120 µV
±8 mV
±15 mV
±30 mV
255
127
8 mV (at SHRO)
06h
7–1
0 to 1.25 V (at SHRO)
255
5.5 mV
05h
7–0
curr_limit
105%–130% (SHRO
2.1 V–2.6 V)
31
26 mV (at SHRO)
04h
7–3
OTP Sense Threshold.
otp_trim (at
input pins)
2.1 V–2.5 V
15
27 mV
0Bh
7–4
Set AC Sense Threshold.
acsns_thresh
1.10 V–1.45 V
31
14 mV
0Ch
7–3
Set AC Sense Hysteresis.
acsns_hyst
200 mV–550 mV
7
50 mV
0Ch
2–0
Rev. A | Page 54 of 64
ADM1041
APPENDIX A—CONFIGURATION TABLE
This table is included for users to program the part by function, rather than by register.
Table 45.
Description
Chip address is 1010xxx.
Second address bit
(EEPROM programmable).
Bit No.
Name
1
add1
First address bit:
ADD0 = L, pin to ground.
ADD0 = H, pin to VDD.
ADD0 = Z, pin open.
Broadcast address.
Config AC_OKLink and
PSONLink.
Bit
Bit
Bit
Option
b1
0
0
0
ADD0
L
H
Z
xxx
000
001
100
Target
device
0
1
4
1
1
1
L
H
Z
010
011
101
2
3
5
X
X
111
ALL
0
i2cmb
b0
0
1
Configure ACSENSE to be
hardware derived or from
an SMBus command.
6
up_AC_OK_m
Configure PSON to be
hardware derived or from
an SMBus command.
7
up_pson_m
b6
0
1
b7
0
1
Configure UV blanking to
be internally derived or
from AC_OKLink. (Set
opposite to i2cmb).
Build FAULT or SMBAIert
signal. Allows a composite
interrupt to be constructed
by ORing up to 15 different
signals.
4
uvbm
b4
0
1
Mode
Normal SMBus, microprocessor
SCL = AC_OK Link
SDA = PSON Link
Mode
Hardware ACSENSE
Microprocessor support via SMBus
Mode
Hardware PS_ON
Micorporcessor support
via SMBus
Mode
UVB follows AC_OKLink
UVB follows ACSENSE
7–0
selcbd1
bn
7
6
5
4
3
2
1
0
signal
ovfault
uvfault
ocpt0 (ridethough timed out)
acsnsb
ocpf
otp (mov5)
orfetokb
Share_OKb
7–1
selcbd2
7
6
5
4
3
2
1
0
VDDOK b
mfgl
mfg2
mfg3
mfg4
m_cbd_w
mfg5
Not used
This uses the CBD pin.
m_cbd_w is a µP writable
bit.
Rev. A | Page 55 of 64
ADM1041
Description
Trim registers, locking bit.
Bit No.
0
Name
trim_lock
Current Sense Mode.
7
csense_mode
Chopper Mode.
6
chopper
Bit
Bit
Bit
b0
0
1
b7
0
1
b6
0
1
Current sense dc offset
adjustment (with respect to
the input).
2–0
os_dc_range
Compensates for the
amplifier input offset
voltage.
Current sense external
divider error correction
range (with respect to the
input).
5–3
os_div_range
Compensates for the
mismatch error of the
external resistor dividers at
Pins 2 and 3.
Option
Mode
Trimming mode
All trim registers locked out
Mode
Differential sense
CT Sense
Mode
Differential current sense amplifier is
continuous (recomended)
Differential sense amplifier is chopper
Trim
b5
0
0
0
b4
0
0
1
b3
0
1
0
−8 mV
−15 V
−30 V
1
1
0
0
0
1
+8 mV
+15 mV
1
1
0
+30 mV
b5
0
0
0
1
1
b4
0
0
1
0
0
b3
0
1
0
0
1
Trim
−5 mV
−10 mV
−20 mV
+5 mV
+10 mV
1
1
0
+20 mV
b2
0
0
0
1
1
1
b1
0
0
1
0
0
1
b0
0
1
0
0
1
0
Gain
65
85
110
135
175
230
Range
34.0 mV–44.5 mV
26.0 mV–34.0 mV
20.0 mV–26 mV
16.0 mV–20.0 mV
12.0 mV–16.0 mV
9.8 mV–12.0 mV
Range
0.45 V–0.68 V
0.79 V–1.20 V
Set differential current
sense gain.
2–0
diff_gain
Set current transformer
input gain.
5
ct_range
b5
0
1
Gain
4.5
2.57
OCP mode. Disables OCP
shutdown.
7
curr_lim_dis
b7
0
1
Mode
OCP timer starts when CCMP > 0.5 V
No OCP shutdown
4–3
ocpts1 Reg12h
ocpts0 Reg12h
2
ocpts2
b3
0
1
0
1
X
Period
1s
2s
3s
4s
100 ms
OCP Ride Through. Sets the
OCP timer duration before
OCP shutdown occurs.
b4
0
0
1
1
X
Rev. A | Page 56 of 64
ADM1041
Description
Option:
Pulse/ACSENSE1/MON1.
Bit No.
Name
Bit
Bit
Bit
3–1
mn1s2
mn1s1
mnls0
b3
0
0
0
b2
0
0
1
b1
0
1
0
0
1
1
1
0
0
1
0
1
1
1
0
1
1
1
b7
0
0
0
b6
0
0
1
b5
0
1
0
0
1
1
1
0
0
1
0
1
1
1
0
1
1
1
b4
0
0
0
b3
0
0
1
b2
0
1
0
0
1
1
1
0
0
1
0
1
1
1
0
1
1
1
b7
0
0
b6
0
0
b5
0
1
Option
iopin = ACSENSE1
iopin = ACSENSE1
+ve ov iopin < 1.15 V
+ve ov iopin > 1.25 V
+ve uv iopin < 1.25 V
+ve uv iopin > 1.35 V
−ve ov iopin < 1.25 V
−ve ov iopin > 1.35 V
−ve uv iopin < 1.15 V
−ve uv iopin > 1.25 V
flag iopin < 1.15 V
flag iopin > 1.25 V
flag iopin < 1.15 V
flag iopin > 1.25 V
flag
ov
uv
0
1
0
0
1
0
0
0
1
0
1
0
1
0
1
1
1
0
0
0
0
0
0
0
0
0
1
0
0
0
flag
ov
uv
0
1
0
1
0
1
0
1
0
1
1
0
flag
0
1
0
0
1
0
0
0
0
0
0
0
ov
0
0
1
0
0
0
0
1
0
0
0
0
uv
0
1
0
1
0
1
0
1
0
1
1
0
0
1
0
0
1
0
0
0
0
0
0
0
0
0
1
0
0
0
0
1
0
0
0
0
flag
ov
uv
Option: ACSENSE2/MON
7–5
Option: PSON/MON3
4–2
mn2s2
mn2s1
mn2s0
mn3s2
mn3s1
mn3s0
iopin = ACSENSE2
iopin = ACSENSE2
+ve ov iopin < 1.15 V
+ve ov iopin > 1.25 V
+ve uv iopin < 1.25 V
+ve uv iopin > 1.35 V
−ve ov iopin < 1.25 V
−ve ov iopin > 1.35 V
−ve uv iopin < 1.15 V
−ve uv iopin > 1.25 V
flag iopin < 1.15 V
flag iopin > 1.25V
flag iopin < 1.15V
flag iopin > 1.25 V
iopin = PSON on = low
iopin = PSON on = high
+ve ov iopin < 1.15 V
+ve ov iopin > 1.25 V
+ve uv iopin < 1.25 V
+ve uv iopin > 1.35 V
−ve ov iopin < 1.25 V
−ve ov iopin > 1.35 V
−ve uv iopin < 1.15 V
–ve uv iopin > 1.25 V
flag iopin < 1.15 V
flag iopin > 1.25 V
flag iopin < 1.15 V
flag iopin > 1.25 V
Option: DC_OK/MON4
7–5
mn4s2
mn4s1
mn4s0
Rev. A | Page 57 of 64
iopin = DC_OK
iopin = DC_OK
ADM1041
Description
To set DC_OK polarity,
see polDC_OK.
Option: VREF/AC_OK/MON5.
Bit No.
4–2
Name
mn5s2
mn5s1
mn5s0
Bit
Bit
Bit
Option
0
1
0
0
1
1
1
0
0
1
0
1
1
1
0
1
1
1
+ve ov iopin < 1.15 V
+ve ov iopin > 1.25 V
+ve uv iopin < 1.25 V
+ve uv iopin > 1.35 V
−ve ov iopin < 1.25 V
−ve ov iopin > 1.35 V
−ve uv iopin < 1.15 V
−ve uv iopin > 1.25 V
flag iopin < 1.15 V
flag iopin > 1.25 V
flag iopin < 1.15 V
flag iopin > 1.25 V
b4
0
0
0
b3
0
0
1
b2
0
1
0
0
1
0
0
1
1
1
0
0
1
0
1
1
1
0
1
1
1
b2
0
1
b2
0
1
0
1
b0
0
1
0
1
b6
0
1
0
1
0
1
0
1
0
1
0
1
0
1
1
0
flag
0
1
0
0
1
0
0
0
0
0
0
0
ov
0
0
1
0
0
0
0
1
0
0
0
0
uv
0
1
0
1
0
0
1
0
0
1
0
1
0
0
0
0
0
0
1
0
0
0
0
iopin = AC_OK
iopin = AC_OK
iopin = AC_OK
0
To set AC_OK polarity,
see polDC_OK.
AC sense source.
2
acss
PSON delay/debounce time.
1–0
psonts1
psonts0
DC_OK on delay.
Delay time from dc outputs
being enabled to DC_OK
being asserted.
1–0
pokts1
pokts0
DC_OK off delay.
Delay time from PSON
forcingDC_OK to be
deasserted to PEN being
deasserted.
7–6
pots1
pots0
b1
0
0
1
1
b1
0
0
1
1
b7
0
0
1
1
Rev. A | Page 58 of 64
+ve ov iopin < vdac
+ve ov iopin > vdac
+ve uv iopin < vdac
+ve uv iopin > vdac
−ve ov iopin < vdac
−ve ov iopin > vdac
−ve uv iopin < vdac
−ve uv iopin > vdac
flag iopin < vdac
flag iopin > vdac
2.5 V ref out
Source
AC_OK from ACSENSE1
AC_OK from ACSENSE2
Period
80 ms
0 ms
40 ms
160 ms
Period
400 ms
200 ms
800 ms
1600 ms
period
2 ms
0 ms
1 ms
4 ms
ADM1041
Description
Current share capture
range.
Maximum output voltage
control range due to the
current share action.
Bit No.
Name
Bit
5–4
ISHARE_capture
b5
Bit
Bit
Option
b4
0
1
0
1
b2
0
1
b2
Range
1%
2%
3%
4%
Mode
Soft-start gated by pen only
Soft-start gated by acsnsok and pen
Rise time
0
1
0
1
b3
0
1
b0
0
1
0
1
b6
0
1
0
1
b4
0
1
0
1
b0
300 µs
10 ms
20 ms
40 ms
Mode
PEN not gated
PEN gated by acsnsok
Period
100 µs
200 µs
300 µs
400 µs
Threshold
100 mV
150 mV
200 mV
250 mV
Threshold
20 mV
30 mV
40 mV
50 mV
Threshold voltage
0
0
1
1
0
1
0
1
b7
0
1
±5%
±100 mV
±10%
±200 mV
±15%
±300 mV
±20%
±400 mV
Mode
OV, UV, OC faults latch
Auto-restarts after OCP or undervoltage
b7
b6
0
0
1
1
0
1
0
1
0
0
1
1
Soft-start mode provides
option for soft-startramp to
be gated by acsnsok
2
gateramp
Soft-start step rise time
(output rise time)
3–2
ssrsl
b3
ssrs0
0
0
1
1
PEN start-up mode
Provides option for PEN to
be gated by acsnsok.
3
gatepen
Load overvoltage
debounce
1–0
loadov_recover
OrFET Reverse Voltage
Threshold.
7–6
rev_volt_off
5–4
rev_volt_on
1–0
Share_OK_thresh
Reverse voltage at which
the ORFET turns off.
OrFET Forward Voltage
Threshold
Reverse voltage at which
the OrFET turns on
Share_OK Window
Threshold
Restart Mode
Provides an option to autorestart after approximately
1 sec.
This applies only to UVP
and OCP faults not to OVP
faults.
Set PEN Output Polarity.
Also selects open-drain
N-channel or P-channel.
7
rsm
6
7
polpen0
polpen1
b1
0
0
1
1
b7
0
0
1
1
b5
0
0
1
1
b1
Rev. A | Page 59 of 64
FET option
N
P
P
N
Polarity
−
+
−
+
ADM1041
Description
Set CBD Output Polarity
Bit No.
5
6
Name
polcbd0
polcbd1
Set OrFET Gate Drive
Polarity
This is an open-drain N-FET
3
polfg
Set DC_OK Output Polarity.
Also selects open-drain
N-channel or P-channel.
5
5
mn4s0
polDC_OK
Set ISHARE Clamp Release
threshold. Percent of
nominal output voltage.
0
ISHARE_clamp
Configure Soft OTP Option
0
softotp
Select CBD Latch Mode
0
cbdlm
Set AC_OK Output Polarity
Also selects open-drain
N-channel or P-channel
2
4
mn5s0
polAC_OK
Bit
Bit
b6
0
0
1
1
b5
0
0
1
1
b4
0
0
1
1
Lock EEPROM Contents
Eliminate offset correction.
Shorts 2 × 50 mV sources in
current share circuit.
Disable groundOK monitor.
An open circuit GND pin
does not affect VDDOK.
7–0
4
1
eeprom_locks
lock7
lock6
lock5
lock4
lock3
lock2
lock1
lock0
selects_gnd_
offset
gndok_dis
Bit
b5
0
1
0
1
b3
Option
FET option
N
P
P
N
Polarity
0
1
b5
0
1
0
1
b0
0
1
b0
0
1
True = low (N-FET on)
True = high (N-FET off)
FET option
Polarity
N
+
P
−
P
−
N
+
Soft-start threshold %
75
88
Mode
MON5 OV causes shutdown.
MON5 OV turns off and then restarts when
temperature falls.
Mode
cbdlm = nonlatching
cbdlm = latching
b0
0
1
b2
0
1
0
1
bn
7
6
5
4
3
2
1
0
FET Option
N
P
P
N
Locks EEPROM range:
Polarity
−
+
−
+
Polarity
+
−
−
+
b4
8140h–817Fh
8120h–813Fh
8100h–811Fh
80C0h–80FFh
8080h–80BFh
8040h–807Fh
8000h–803Fh
gnd_offset
ISHARE_amp_offset
0
1
100 mV
0 mV
50 mV
0 mV
b1
0
1
Rev. A | Page 60 of 64
GND monitoring enabled.
GND monitoring disabled, that is, always OK.
ADM1041
APPENDIX B—TEST NAME TABLE
This table is included for ADI’s internal reference use This is a cross reference for the ADI test program.
Table 46.
Specification
Supplies
VDD
IDD, Current Consumption
Peak IDD, during EEPROM Erase Cycle
UNDERVOLTAGE LOCKOUT, VDD
Start-Up Threshold
Stop Threshold
Hysteresis
2.5 V Ref Out
Output Voltage
Line Regulation
Load Regulation
Temperature Stability
Long-Term Stability
Current Limit
Output Resistance
Load Capacitance
Ripple Due to Autozero
POWER BLOCK PROTECTION
VDD Overvoltage
VDD Overvoltage Debounce
VREF Overvoltage
VREFOUT Undervoltage
Open Ground
Debounce
POWER-ON RESET
DC Level
DIFFERENTIAL LOAD VOLTAGE SENSE
INPUT, (VS−, VS+)
VS− Input Voltage
VS+ Input Voltage
VS− Input Resistance
VS+ Input Resistance
VNOM Adjustment Range
Set Load Voltage Trim Step
Minimum Set Load Overvoltage Trim
Range
Set Load Overvoltage Trim Step
Recover from Load OV False to
FG True
Operate Time from Load OV to
FG False
LOCAL VOLTAGE SENSE, VLS,
AND FALSE UV CLAMP
Input Voltage Range
Stage Gain
False UV Clamp, VLS Input Voltage
Nominal, and Trim Range
Clamp Trim Step
Test Name
VDD
IDD
VDD (ON)
VDD (OFF)
VDDHYS
VREF
VREF
VLINE
VLOAD
TCREF
VREF_STAB
IMAX
RO
CL
VREF_RIPPLE
VOVP
TDFILTER
VRMOVP
VROUVP
VGND
TDEBOUNCE
VPOR
VDVCM
VDVIN_MAX
VDVINRN
VDVINRP
VDVADJ
VDVTRIM
VDVLOV
VLOVTRIM
TLOADOV_FALSE
TLOADOV_TRUE
VLS_RANGE
ACLAMP
VCLMPTRIM
Specification
Local Overvoltage
Nominal and Trim Range
OV Trim Step,
OV Trim Step,
Noise Filter, for OVP Function Only
Local Undervoltage
Nominal and Trim Range
UV Trim Step
UV Trim Step
Noise Filter, for UVP Function Only
VOLTAGE ERROR AMPLIFIER
Reference Voltage
Temperature Coefficient
Long-Term Voltage Stability
Soft-start Period Range
Set Soft-start Period
Unity Gain Bandwidth
Transconductance
Source Current
Sink Current
DIFFERENTIAL CURRENT SENSE INPUT,
CS− CS+
Common-Mode Range,
External Divider Tolerance Trim
Range (with respect to input)
External Divider Tolerance Trim Step
Size (with respect to input)
DC Offset Trim Range (os_dc_range)
(with respect to input)
DC Offset Trim Step Size (with
respect to input)
Total Offset Temperature Drift
Gain Range (Isense_range)
Gain Setting 1 (16h, B2–0 = 000)
Gain Setting 2 (16h, B2–0 = 001)
Gain Setting 3 (16h, B2–0 = 010)
Gain Setting 4 (16h, B2–0 = 100)
Gain Setting 5 (16h, B2–0 = 101)
Gain Setting 6 (16h, B2–0 = 110)
CURRENT SENSE CALIBRATION
Full Scale (No Offset),
Attenuation Range
Current Share Trim Step (At SHRO),
Current Sense Accuracy, (40 mV)
Cal. Accuracy, 20 mV at CS+, CS−
Cal. Accuracy, 40 mV at CS+, CS–
Cal. Accuracy, 40 mV at CS+, CS−
VCLMPSTEP
Rev. A | Page 61 of 64
Test Name
VLSOV
VLSOVSTEP
VLSOVSTEP
TNFOVP
VLSUV
VLSUVSTEP
VLSUVSTEP
TNFUVP
VCMP
VREF_VCMP
TCV
VSTAB
TSSRANGE
TSS
GBW
G mVCMP
ISOURCE_VCMP
ISINK_VCMP
VCM_RANGE
VOS_DIV_RANGE
VOS_DIV_STEP
VOS_DC_RANGE
VOS_DC_STEP
TDRIFT
Isense_range
G65X
G85X
G110X
G135X
G175X
G230X
VSHR
VSHRSTEP
TolCSHR
TolCSHR
TolCSHR
ADM1041
Specification
SHARE BUS OFFSET
Current Share Offset Range
Zero Current Offset Trim Step
CURRENT TRANSFORMER SENSE INPUT
Gain Setting 0
Gain Setting 1
CT Input Sensitivity (Gain Set 0)
CT Input Sensitivity (Gain Set 1)
Input Impedance
Source Current
Source Current Step Size
Reverse Current for Extended
SMBus Addressing
CURRENT LIMIT ERROR AMPLIFIER
Current Limit Trim Range
Current Limit Trim Step
Current Limit Trim Step
Transconductance
Output Source Current
Output Sink Current
CURRENT SHARE DRIVER
Output Voltage
Short-Circuit Source Current
Source Current
Sink Current
CURRENT SHARE DIFFERENTIAL
SENSE AMPLIFIER
VS– Input Voltage
VSHRS Input Voltage
Input Impedance
Gain
CURRENT SHARE ERROR AMPLIFIER
Transconductance, SHRS to SCM
Output Source Current
Output Sink Current
Input Offset Voltage
Share OK Window Comparator
Threshold (Share Drive Error)
CURRENT LIMIT
Current Limit Control Lower
Threshold
Current Limit Control Upper
Threshold
CURRENT SHARE CAPTURE
Current Share Capture Range
Capture Threshold
FET OR GATE DRIVE
Output Low Level (On)
Output Leakage Current
Polarity Select, Vgateon
Test Name
VZO
VZOSTEP
ICT
GCT_X4
GCT_X2
VCT_X4
VCT_X2
RIN_CT
ISOURCE_CT
ISTEP_CT
IREV
CLIM
CLIMSTEP
CLIMSTEP
GmCCMP
ISOURCE_CCMP
ISINK_CCMP
VSHRO_1K
ISHRO_SHORT
ISHRO_SOURCE
ISHRO_SINK
RIN_SHR_DIFF
GSHR_DIFF
GmSCMP
ISOURCE_SCMP
ISINK_SCMP
VIN_SHR_OFF
VSHR_THRES
VCLIM_THRES_MIN
VCLIM_THRES_MAX
SHRCAPT_RANGE
VSHR_CAPT_THRES
VLO_FET
IOL_FET
Specification
REVERSE VOLTAGE COMPARATOR,
FS, FD
Common-Mode Range
Input Impedance
Reverse Voltage Detector Turn-Off
Threshold
Reverse Voltage Detector Turn-On
Threshold
ACSENSE1/ACSENSE2 COMPARATOR
(AC or Bulk Sense)
Threshold Voltage
Threshold Adjust Range
Threshold Trim Step
Hysteresis Voltage
Hysteresis Adjust Range
Hysteresis Trim Step
Noise Filter
PULSE-IN
Threshold Voltage
Pulseok on delay
Pulseok off delay
OSCILLATOR AND TIMING
General Tolerance on Time Delays
OCP
OCP Threshold Voltage
OCP Shutdown Delay Time
(Continuous Period in Current
Limit)
OCP Fast Shutdown Delay Time
MON1, MON2, MON3, MON4
Sense Voltage
Hysteresis
OVP Noise Filter
UVP Noise Filter
OTP (MON5)
Sense Voltage Range
OTP Trim Step
Hysteresis
OVP Noise Filter
UVP Noise Filter
PSON
Input Low Level
Input High Level
Debounce
PEN, DC_OK, CBD, AC_OK
Open-Drain N-Channel Option
Output Low Level = On
Open-Drain P-Channel
Output High Level = On
Leakage Current
Rev. A | Page 62 of 64
Test Name
RFS, RFD
VRVD_THRES_OFF
VRVD_THRES_ON
VSNSADJ_THRES
VSNSADJ_RANGE
VSNSADJ_STEP
VSNSHST
VSNSHYS_RANGE
VSNSHYS_STEP
TNFSNS
VPULSEMIN
TPULSEON
TPULSEOFF
VOCP_THRES
TOCP_SLOW
TOCP_FAST
VMON1
VMON1_HST
TNFOVP_MON1
TNFUVP_MON1
VOTP_RANGE
VOTP_STEP
IOTP_HST
TNFOVP_OTP
TNFUVP_OTP
VIL_PSON
VIH_PSON
TNF_PSON
VOL_PEN
VOH_PEN
IOH_PEN
ADM1041
Specification
DC_OK
DC_OK, On Delay
(Power-On and OK Delay)
DC_OK, Off Delay
(Power-Off Early Warning)
SMBus, SDL/SCL
Input Voltage Low
Input Voltage High
Output Voltage Low
Pull-Up Current
Leakage Current
ADD0, HARDWIRED ADDRESS BIT
ADD0 Low Level
ADD0 Floating
ADD0 High
Test Name
TDCOK_ON
TDCOK_OFF
VIL
VIH
VOL
IPULLUP
ILEAK
Specification
SERIAL BUS TIMING
Clock Frequency
Glitch Immunity
Bus Free Time
Start Setup Time
Start Hold Time
SCL Low Time
SCL High Time
SCL, SDA Rise Time
SCL, SDA Fall Time
Data Setup Time
Data Hold Time
EEPROM RELIABILITY
Endurance
Data Retention
Rev. A | Page 63 of 64
Test Name
fSCLK
tSW
tBUF
tSU;STA
tHD;STA
tLOW
tHIGH
tr
tf
tSU;DAT
tHD;DAT
ADM1041
OUTLINE DIMENSIONS
0.341
BSC
24
13
0.154
BSC
1
0.236
BSC
12
PIN 1
0.069
0.053
0.065
0.049
0.010
0.004
0.025
BSC
0.012
0.008
COPLANARITY
0.004
SEATING
PLANE
0.010
0.006
8°
0°
0.050
0.016
COMPLIANT TO JEDEC STANDARDS MO-137AE
Figure 39. 24-Lead QSOP (RQ-24)
Dimensions shown in millimeters
ORDERING GUIDE
Model
ADM1041ARQ
ADM1041ARQ-REEL
ADM1041ARQ-REEL7
Temperature Range
−40°C to +85°C
−40°C to +85°C
−40°C to +85°C
Package Description
24-Lead QSOP
24-Lead QSOP
24-Lead QSOP
Package Option
RQ-24
RQ-24
RQ-24
Purchase of licensed I2C components of Analog Devices or one of its sublicensed Associated Companies conveys a license for the purchaser under the Philips I2C Patent
Rights to use these components in an I2C system, provided that the system conforms to the I2C Standard Specification as defined by Philips.
© 2004 Analog Devices, Inc. All rights reserved. Trademarks and
registered trademarks are the property of their respective owners.
D04521-0-5/04(A)
Rev. A | Page 64 of 64
Similar pages