Keysight E7515A UXM Wireless Test Set Data Sheet 02 | Keysight | E7515A UXM Wireless Test Set - Data Sheet Make a Clear Call The team looks to you: will a new chipset or UE pass the crucial tests? Clarity comes from accumulated insights – insights enabled by the Keysight Technologies’s UXM wireless test set. The UXM is a highly integrated signaling test set created for functional and RF design validation in the 4G era and beyond. It provides the capabilities you need to test the newest designs, delivering LTE-Advanced data rates up to 1 Gbps now and handling more complex requirements later. When the team counts on you, count on the UXM to help you assess design readiness with greater confidence and make a clear call. Definitions and Conditions The specifications in this document apply to single TRX instruments with serial number MY5520xxxx/TH5520xxxx and dual TRX instruments with serial number MY5521xxxx/ TH5521xxxx. The test set will meet its specifications when –– The test set is within its calibration cycle –– The test set has been stored at an ambient temperature within the allowed operating range for at least two hours before being turned on; if it had previously been stored at a temperature range inside the allowed storage range, but outside the allowed operating range –– The test set has been turned on for at least 30 minutes Specification Specifications describe the performance parameters covered by the product warranty and are valid from 20 to 35 °C unless otherwise noted. Typical Typical describes additional product performance information that is not covered by the product warranty. It is performance beyond specifications that 95 percent of the units exhibit with a 95 percent confidence level. This data, shown in italics, does not include measurement uncertainty, and is valid only at room temperature (23 °C). Nominal Nominal values indicate expected performance, or describe product performance that is useful in the application of the product, but are not covered by the product warranty. 03 | Keysight | E7515A UXM Wireless Test Set - Data Sheet Vector Signal Analyzer Performance Frequency and time specification Operating frequency range E7515A-504 E7515A-506 300 MHz to 3.8 GHz 300 MHz to 6.0 GHz Frequency setting resolution 100 kHz Frequency accuracy See Timebase specifications VSWR all RF inputs 300 MHz to 2.0 GHz >2.0 to 5.0 GHz >5.0 to 6.0 GHz 1.4 nominal 1.5 nominal 1.8 nominal Amplitude and range specifications CW level accuracy –60 to +30 dBm for Rx1, Rx2; –53 to +30 dBm for TxRx1, TxRx2 300 MHz to 3.5 GHz >3.5 to 6.0 GHz –53 to +3.5 dBm 300 MHz to 3.5 GHz >3.5 to 6 GHz ±0.45 dB typical ±0.45 dB typical ±1.0 dB ±1.1 dB Level flatness ±0.3 dB typical over 100 MHz bandwidth Noise floor For combined Tx and Rx For separate Tx and Rx <140 dBm/Hz nominal <150 dBm/Hz nominal Maximum CW input level at connectors TxRx1 and TxRx2 +33 dBm 04 | Keysight | E7515A UXM Wireless Test Set - Data Sheet Vector Signal Generator Performance Frequency and time specification Operating frequency range E7515A-504 E7515A-506 300 MHz to 3.8 GHz 300 MHz to 6.0 GHz Frequency setting resolution 100 kHz Frequency accuracy See Timebase specifications VSWR all RF inputs 300 MHz to 2.0 GHz >2.0 to 5.0 GHz >5.0 to 6.0 GHz 1.4 nominal 1.5 nominal 1.8 nominal Amplitude and range specifications CW output power range TxRx1, TxRx2 Tx1, Tx2 –110 to –7 dBm nominal (–110 to –10 dBm for typical and warranted) –110 to +5 dBm nominal (–110 to 0 dBm for typical and warranted) CW output level accuracy TxRx1, TxRx2 and Tx1, Tx2 300 MHz to 3.5 GHz > 3.5 to 6.0 GHz ±1.0 dB, ±0.45 dB typical ±1.0 dB, ±0.45 dB typical Output level setting resolution 0.1 dB Output level settling time ±1.0 dB within 25 µs nominal Output flatness ±0.3 dB typical over 100 MHz bandwidth Harmonics Attenuation of 2nd harmonic TxRx1, TxRx2 300 MHz to 4.0 GHz, power <–10 dBm >4.0 to 6.0 GHz, power <–10 dBm >30 dB nominal >45 dB nominal Attenuation of 2nd harmonic Tx1, Tx2 300 MHz to 4.0 GHz, power <0 dBm >4.0 to 6.0 GHz, power <0 dBm >30 dB nominal >45 dB nominal Attenuation of 3rd harmonic TxRx1, TxRx2 300 MHz to 3.0 GHz, power <–10 dBm >3.0 to 6.0 GHz, power <–10 dBm >40 dB nominal >55 dB nominal Attenuation of 3rd harmonic Tx1, Tx2 300 MHz to 3.0 GHz, power <0 dBm >3.0 to 6.0 GHz, power <0 dBm >40 dB nominal >55 dB nominal Attenuation of non-harmonics TxRx1, TxRx2 300 MHz to 6.0 GHz, –10 dBm, power >–40 dBm >40 dB nominal Attenuation of non-harmonics Tx1, Tx2 300 MHz to 6.0 GHz, –10 dBm, power >–40 dBm >40 dB nominal Phase noise –90 dB at 10 kHz offset nominal Maximum reverse power TxRx1, TxRx2 Tx1, Tx2 <±33 dBm <±30 dBm 05 | Keysight | E7515A UXM Wireless Test Set - Data Sheet Instrument Specifications Input power requirements Voltage and frequency 100/120/220/240 VAC, 50/60 Hz, nominal Power consumption (instrument with 2 TRXs) 1100 W max Additional specifications Dimensions (H x W x L) Without feet and handles With feet and handles 305 mm x 435 mm x 445 mm 321 mm x 435 mm x 504 mm Weight One TRX Two TRXs 33 kg 36 kg Operating temperature 5 to 45 °C, 30 g/m³ absolute humidity, 5 to 85% non-condensing relative humidity Storage temperature –40 to +65 °C, 50 g/m³ absolute humidity, 5 to 85% non-condensing relative humidity Altitude Up to 2000 m Radiated leakage due to RF generator < 2.5 µV induced in a resonant dipole antenna one inch from any surface except the underside and rear panel set at RF generator output frequency and output level of –40 dBm typical EMC Complies with European EMC Directive 2004/108/EC –– IEC/EN 61326-1 –– CISPR Pub 11 Group 1, class A –– AS/NZS CISPR 11 –– ICES/NMB-001 –– This ISM device complies with Canadian ICES-001. Cet appareil ISM est conforme a la norme NMB-001 du Canada. –– South Korean Class A EMC declaration: This equipment is Class A suitable for professional use and is for use in electromagnetic environments outside of the home. A급 기기 (업무용 방송통신기 자재) 이기기는 업무용(A급) 전자파 적합기기로서 판매자 또 는 사용자는 이 점을 주의하시기 바라며, 가정외의 지역에서 사용하는 것을 목적으로 합니다. Mechanical resistance EN60068-2-6, EN60068-2-27, EN60068-2-64 Safety Complies with European Low Voltage Directive 2006/95/EC –– IEC/EN 61010-1, 3rd edition –– Canada: CAN/CSA C22.2 No. 61010-1012 –– USA: UL std no. 61010-1, 3rd Edition –– Acoustic statement (European Machinery Directive 2002/42/EC, 1.7.4.2u) Acoustic noise emission, LpA <70 dB, Operator position, Normal operation mode, Per ISO 7779 RF connections Tx1, Tx2 N-type female, 50 Ω nominal TxRx1, TxRx2 N-type female, 50 Ω nominal Other connectors and interfaces Display/Manual user interface USB ports Front panel Rear LAN (local area network) ports 15.4 in (391 mm) active matrix, color, 1280 x 800 pixel resolution TFT-LCD flat panel display with touch panel controls; single-touch capacitive touch-screen; HDMI port 2 USB 2.0 ports 2 USB 2.0 ports One external, 1 Gbps, LAN port rear panel One external, 1 Gbps, LAN port front panel 06 | Keysight | E7515A UXM Wireless Test Set - Data Sheet Instrument Specifications (continued) Digital data acquisition General memory budgets and considerations RCB available memory Memory allocation for digital acquisition 512 MB 256 MB Basic acquisitions IQ data acquisition channels Sample rates Maximum sample storage 2 (one per BS Rx antenna) 30.72 MSa/s, 122.88 MSa/s 32 MSa per BS Rx antenna Fixed size buffers per channel and allocation Single or dual channel (RF Carrier) Single or dual channel (RF Input) 30.72 MHz: 1092 ms 122.88 MHz: 273 ms Maximum digitalized data size 128 MB per channel Trigger control Immediate, event-based Ethernet Source selection RF Input (1 & 2) RF Carrier (1 & 2) 100 MHz bandwidth (122.88 MSa/s) 20 MHz bandwidth (30.72 MSa/s) Channel emulation Antenna configuration 1x1, 1x2, 2x2, 4x2 3GPP LTE Rel 8 for RF fading profiles Bypass EPA 5, custom Max Doppler frequency EVA 5, 70, 200, custom Max Doppler frequency ETU 70, 200, 300, custom Max Doppler frequency HST CQI 3GPP TD-SCDMA/HSPA RF fading profiles Bypass Multi-path case 1 to 3 PA3 PB3 VA 30, 120 HST Moving Birth death 3GPP W-CDMA/HSPA+ RF fading profiles Bypass Multi-path case 1 to 3 PA3 PB3 VA 30, 120 HST Moving Birth death 07 | Keysight | E7515A UXM Wireless Test Set - Data Sheet Instrument Specifications (continued) PA3 PB3 2 VA 30, 120 No channel Channel 1 Channel 2 Channel 1 and 2 HST –189 to –81 dBm/Hz –179 to –71 dBm/Hz Moving –49.6 to 49.6 MHz Birth Death 1.08, 2.7, 4.5, 9.0, 13.5, 18.0 MHz Continuous wave generation Independent channels 2 Antenna output No channel Channel 1 Channel 2 Channel 1 and 2 Digital frequency offset –50 to 50 MHz Time base Standard frequency reference Maximum frequency drift Short term stability Warm-up time ±0.7 ppm/year ±0.005 ppm 1 minute to be ±0.1 ppm at 25 ºC External clock time reference Connector type SMA connector SYNC IN, rear panel Frequency Sine wave Square wave (greater than 40% ON duty cycle) Input voltage range Impedance 10 MHz 10 MHz 0.4 to 2 Vpp 50 Ω nominal Format alignment trigger External connector SMA Channel 0 Trigger duration configurable according format LTE Where sample resolution = (1/30.72) x 10-6 0 to 30719 samples Trigger offset delay In terms of 1/6 of the period of the sample Trigger period configurable according format LTE 1 to 10240 packets Generic trigger External connector SMA Channel 1, 2, 3 (Input, Output) Arm channel for receiving trigger Only input channels External trigger generation Only output channels Warranty and calibration Standard warranty Three years Recommended calibration cycle One year 08 | Keysight | E7515A UXM Wireless Test Set - Data Sheet LTE Measurements Modulation and channels Signal structure FDD and TDD (with appropriate licenses) Signal bandwidth 1.4, 3, 5, 10, 15, 20 MHz LTE signal generation Error vector magnitude (EVM) 20 MHz LTE PDSCH signal with full allocation (100 RBs) modulation = 64QAM; power = –20 dBm 300 MHz to 3.5 GHz >3.5 to 6 GHz <2% RMS nominal <2.25% RMS nominal LTE power measurements Level range (BW 20 MHz, OFDM, 64QAM) –45 to +30 dBm, RMS LTE channel power accuracy ±0.65 dB nominal LTE adjacent channel power Dynamic range E-UTRA UTRA >45 dB nominal >45 dB nominal Residual EVM (5, 10, 15, 20 MHz bandwidths) <2% RMS typical at –20 dBm input power GSM/GPRS/EGPRS Measurements Modulation, bands, and frequency Modulation types GMSK and 8PSK Bands GSM450, GSM480, GSM750, PGSM, EGSM, RGSM, TGSM810, GSM850, DCS, PCS Frequency range 0.45 to 2 GHz (within bands) GSM/GPRS/EGPRS signal generation Modulated output power range TxRx1, TxRx2 –110 to –10 dBm Tx1, Tx2 –110 to 0 dBm Output level accuracy with GMSK or 8PSK ±0.55 dB, typical GSM/GPRS/EGPRS measurements Level range –25 to +30 dBm Transmit power accuracy ±0.5 dB, typical TD-SCDMA/HSPA Measurements Modulation, bands, and frequency Modulation types QPSK and 16QAM Bands a, b, c, d, e, f, 41 Frequency range 1.8 to 2.7 GHz (within bands) TD-SCDMA/HSPA signal generation Modulated output power range TxRx1, TxRx2 –110 to –13 dBm/1.28 MHz Tx1, Tx2 –110 to –5 dBm/1.28 MHz Output level accuracy with QPSK or 16QAM ±0.5 dB, typical TD-SCDMA/HSPA measurements Level range –65 to +30 dBm/1.28 MHz Channel power accuracy ±0.5 dB, typical 09 | Keysight | E7515A UXM Wireless Test Set - Data Sheet W-CDMA/HSPA+ Measurements Modulation, bands, and frequency Modulation types Downlink QPSK, 16QAM, 64QAM Uplink QPSK, 16QAM Bands 1 to 14, 19 to 21, 25, 26 Frequency range 0.7 to 2.7 GHz (within bands) W-CDMA/HSPA+ signal generation Modulated output power range TxRx1, TxRx2 –110 to –13 dBm/3.84 MHz Tx1, Tx2 –110 to –5 dBm/3.84 MHz Output level accuracy with QPSK or 16QAM ±0.7 dB, typical W-CDMA/HSPA+ measurements Level ranges Channel power, frequency error –61 to +28 dBm/3.84 MHz ACLR, OBW, SEM +5 to +28 dBm/3.84 MHz EVM –25 to +28 dBm/3.84 MHz Channel power accuracy ±0.7 dB, typical Adjacent channel leakage ratio (ACLR) accuracy ±0.7 dB, nominal Spectrum emissions mask (SEM) accuracy ±1.5 dB, nominal Occupied bandwidth (OBW) accuracy <100 kHz, nominal Error vector magnitude (EVM) accuracy <2.5% RMS, nominal Frequency error accuracy <10 Hz, nominal 10 | Keysight | E7515A UXM Wireless Test Set - Data Sheet From Hewlett-Packard through Agilent to Keysight For more than 75 years, we‘ve been helping you unlock measurement insights. Our unique combination of hardware, software and people can help you reach your next breakthrough. Unlocking measurement insights since 1939. 1939 THE FUTURE myKeysight www.keysight.com/find/mykeysight A personalized view into the information most relevant to you. Three-Year Warranty www.keysight.com/find/ThreeYearWarranty Keysight’s committed to superior product quality and lower total cost of ownership. Keysight is the only test and measurement company with three-year warranty standard on all instruments, worldwide. And, we provide a one-year warranty on many accessories, calibration devices, systems and custom products. Keysight Assurance Plans www.keysight.com/find/AssurancePlans Up to ten years of protection and no budgetary surprises to ensure your instruments are operating to specification, so you can rely on accurate measurements. Keysight Infoline www.keysight.com/find/service Keysight’s insight to best in class information management. Free access to your Keysight equipment company reports and e-library. Keysight Channel Partners www.keysight.com/find/channelpartners Get the best of both worlds: Keysight’s measurement expertise and product breadth, combined with channel partner convenience. www.keysight.com/find/uxm www.keysight.com/find/e7515a For more information on Keysight Technologies’ products, applications or services, please contact your local Keysight office. The complete list is available at: www.keysight.com/find/contactus Americas Canada Brazil Mexico United States (877) 894 4414 55 11 3351 7010 001 800 254 2440 (800) 829 4444 Asia Pacific Australia China Hong Kong India Japan Korea Malaysia Singapore Taiwan Other AP Countries 1 800 629 485 800 810 0189 800 938 693 1 800 11 2626 0120 (421) 345 080 769 0800 1 800 888 848 1 800 375 8100 0800 047 866 (65) 6375 8100 Europe & Middle East Austria Belgium Finland France Germany Ireland Israel Italy Luxembourg Netherlands Russia Spain Sweden Switzerland United Kingdom 0800 001122 0800 58580 0800 523252 0805 980333 0800 6270999 1800 832700 1 809 343051 800 599100 +32 800 58580 0800 0233200 8800 5009286 800 000154 0200 882255 0800 805353 Opt. 1 (DE) Opt. 2 (FR) Opt. 3 (IT) 0800 0260637 For other unlisted countries: www.keysight.com/find/contactus (BP-02-10-16) DEKRA Certified ISO9001 Quality Management System www.keysight.com/go/quality Keysight Technologies, Inc. DEKRA Certified ISO 9001:2015 Quality Management System This information is subject to change without notice. © Keysight Technologies, 2014 - 2016 Published in USA, July 18, 2016 5991-4634EN www.keysight.com